• Title/Summary/Keyword: MMI

Search Result 252, Processing Time 0.038 seconds

Determination of 2-Mercapto-1-methyl-imidazole in Antithyroid Drug by Differential Pulse Polarography (항갑상선 의약물 중 2-mercapto-1-methyl-imidazole의 펄스차이 폴라로그래피에 의한 분석)

  • Kim, Il Kwang;Chun, Hyun Ja;Lim, Soon Hwa
    • Analytical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.17-23
    • /
    • 1995
  • The determination method of 2-mercapto-1-methyl-imidazole(MMI) in $5.0{\times}10^{-2}M$ lithium perchlorate solution has been investigated by the differential pulse polarography. The optimum conditions for the determination of MMI were as fellows; -0.9 volt(vs. Ag/AgCl) initial potential, 80mV pulse height, 2mV/sec scan rate, and medium mercury drop size. The calibration curve showed a good linearlity in the range of $1.0{\times}10^{-7}M$ to $8.0{\times}10^{-5}M$ and the detection limit was $2.2{\times}10^{-9}M$. This method was applicable to the determination of MMI in thyroid drugs without interference from the additives.

  • PDF

A Study on the Development of the SCADA System using the Internet (인터넷을 이용한 SCADA 시스템 구축에 관한 연구)

  • Park, I.K.;Yoon, K.K.;Kim, Y.S.;Lee, S.G.;Ahn, B.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2373-2376
    • /
    • 1998
  • This paper describes the development of the SCADA(Supervisory Control and Data Acquisition) system which can be controlled via the Internet. In this paper, the SCADA system is composed of a number of microprocessor-based RTU(Remote Terminal Unit)s, a MMI(Man Machine Interface) host, a SCADA server, and SCADA clients. There are two protocols used in the system. Each RTU and the MMI host are connected by a RS-485 line and CSMA/CD(Carrier Sense Multiple Access / Collision Detection) protocol is used to communicate with each other. TCP/IP(Transmission Control Protocol/Internet Protocol) is used among the MMI host, the SCADA server, and SCADA clients. The equipments installed in the field are controlled by a number of RTUs. The function of the MMI host is to acquire real-time data from RTUs and control them. The SCADA server supports data transfer between the networked MMI host and the SCADA client on the web-server through TCP/lP. Data transfer is possible regardless of the type of network only if there are TCP/lP Winsock-compatible stack driver. The SCADA client is implemented as the shape of web-page by means of JAVA language. Therefore, it runs on a web-browser such as Netscape and Explorer, and allows a number of users to access this SCADA system.

  • PDF

Fault Diagnosis System for Industrial Motor Drives (산업용 전동기 구동장치의 고장진단 시스템)

  • Song, S.H.;Cho, W.J.;Park, I.Y.;Park, K.W.;Lee, C.W.;Kim, K.H.;Choi, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.488-490
    • /
    • 1994
  • To meet the requirements of high performance and reliability as a industrial motor drive, we developed an integrated oil-line fault diagnosis and monitoring system which consists of DSP-based controller and PC-based MMI (Man-machine interface) program. The dedicated controller performs real-lime fault detections and protections. The MMI program monitors the on-line fault status of the drive system and offers full explanations of the fault name(WHAT?), deducible causes of the fault operation(WHY?), and chock points (HOW?) based upon the experiences of the expert. Also the TRACE data which was stored just before and after the accident can be scrutinized using MMI tools.

  • PDF

Technical report : Developement of MMI and embedded CDMA controller for waterworks management system (농촌 간이 상수도 통합관리를 위한 임베디드 CDMA 컨트롤러 개발 및 원격 모니터링 시스템 개발 사례)

  • Ahn, Pi-Us;Jeon, S.K.;Kim, M.H.;Lee, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1903-1904
    • /
    • 2006
  • This technical report provide practical waterwork management system by using CDMA telecommunication method. Local water supply unit and tude-well unit which is placed in the mountainous area could be controlled remotely by MMI monitoring system. Developed method of waterwork managing system is a newly application area of CDMA technology which include web-based control units.

  • PDF

DEVELOP AND USE OF STUD PENETRATE WELDING TECHNOLOGY IN COMPOSITE FLOOR OF STEEL STRUCTURE

  • Fu, Jifei;Zhang, Youquan;Ma, Dezhi
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.349-354
    • /
    • 2002
  • Stud penetrate welding is an important item of composite floor in modern steel structure, especially in high-rise buildings. But it is difficult to get satisfied welding quality due to all kinds of factors. In this paper, the author put forward a new welding procedure named method of energy control through analysis and comparison of the wave curves of stud welding based on large amount of experiments and tests in laboratory and construction areas. The use of this welding procedure in some large engineering in recent years proved that this method is effective and practicable

  • PDF

The Application of Boiler Digital Control System 3D MMI Using Virtual Real (보일러 분산제어 시스템 3차원 MMI 구현)

  • Oh, Young-Il;Kim, Eung-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.880-882
    • /
    • 1999
  • Virtual Reality is a set of computer technologies which, when combined, provide an interface to a computer-generated world, and in particular, provide such a convincing interface that the user believes he is actually in a three dimensional computer-generated world. This computer generated world may be a model of a real-world object, such as a house; it might be an world that does not exist in a real sense but is understood by humans, such as a chemical molecule or a representation of a set of data; or it might be in a completely imaginary science fiction world. this paper describes the application of boiler digital control system MMI for power plant using virtual reality

  • PDF

Dynamic Layout Design of Spinner MMI for 300mm Wafer (300mm 웨이퍼용 Spinner MMI를 위한 동적 레이아웃 설계)

  • Yoon, Young-Ho;Han, Kwang-Rok;Sohn, Seok-Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2000.10a
    • /
    • pp.703-706
    • /
    • 2000
  • 반도체 제조 공정의 효율적인 제어와 감시를 위한 모니터링 시스템을 구성하기 위해서는 장비가 가진 특성과 시스템 환경에서 요구되는 조건들과 동작 상태 둥을 사용자 인터페이스를 통하여 한 눈에 감시할 수 있는 화면 레이아웃이 요구된다. 본 논문에서는 차세대 반도체 장비인 300mm 웨이퍼 가공용 Spinner 의 MMI 개발을 목표로 하여 장비의 구성 요소들의 선택적 접속에 따라서 사용자 인터페이스용 레이아웃을 능동적으로 설계하는 방법에 대하여 기술하였다. 장비를 구성하는 기본 요소들간의 관계를 정의하고, 장비의 사양과 웨이퍼의 가공 목적에 따라 구성 요소들을 자동으로 유연성있게 배치하도록 하였다.

  • PDF

A Development of MMI using Open Interface (Open Interface를 적용한 MMI 개발)

  • Oh, S.M.;Min, B.U.;Lee, S.J.;Choi, M.S.;Yoon, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.253-255
    • /
    • 2002
  • The paper presets the improvements of MMI at the PROSET2000 correction program which is totally computerized system of the power system protection. The Base Form that is an open interface is developed to be able to compose the screen by reading the input screen from the database. It also is developed to be suitable for the environment of the Graphical User Interface instead of the DOS window when the users do the pannel settings. Program development in this paper is designed by Unified Modeling Language(UML) techniques.

  • PDF

Design, Implementation and Validation of the KOMPSAT Spacecraft Simulator

  • Choi, Wan Sik;Lee, Sanguk;Eun, Jong Won;Choi, Han Jun;Chae, Dong Suk
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.1 no.2
    • /
    • pp.50-67
    • /
    • 2000
  • The spacecraft simulator is used for command validation, operational check of the Satellite Operation Subsystem (SOS), spacecraft anomaly analysis support, satellite operator training etc. In this paper, S/W design features and modeling characteristics of the KOMPSAT Spacecraft Simulator Subsystem (SIM) are described. Validation procedures and simulation results are also provided. The SIM provides extensive simulation capabilities by including models for most of the spacecraft subsystems. The software structure of the SIM was designed and implemented so as to support operations not only in real-time but also in non real-time by utilizing the Hewlett Packard (HP) UNIX functions. The SIM incorporates as many user-friendly Man Machine Interface (MMI) windows as possible so that all the SIM normal operations can be executed through the MMI windows.

  • PDF

Optimization for Arrayed Waveguide Grating having MMI Coupler for Flattened Transfer Function

  • Jung, Jae-Hoon
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.4
    • /
    • pp.169-173
    • /
    • 2006
  • This paper describes an efficient optimal design method for an arrayed waveguide grating (AWG) having MMI coupler with flattened transfer function. The objective function is the norm of the difference between calculated and target spectra. To analyze the AWG transfer function, the Fresnel-Kirchhof diffraction formula was employed and the design variable was optical path difference of each array waveguide. The (1+1) Evolution Strategy was applied to an eight-channel coarse wavelength division multiplexing (CWDM) AWG as the optimization tool. For obtaining a broadened spectrum, we use a MMI coupler and the variation in optical path difference at each array waveguide changes the shape of the transfer function to obtain the optimal spectrum shape.