• Title/Summary/Keyword: MM system

Search Result 6,416, Processing Time 0.03 seconds

Study on Solid Rocket Propellants for 120mm Mortar (120미리 박격포용 고체 로켓추진제 연구)

  • Cho, Joon-Hyun;Kwon, Tae-Soo;Jeong, Deok-Jin;Yim, Yoo-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.173-176
    • /
    • 2009
  • The mortar system is useful for infantry because of effectiveness to position operation and to attack at opposite slope that can not reached by direct-firing guns and howitzers. The Army continuously has researched on 120mm mortar system, and insist needs for 120mm mortar system with advanced accuracy, mobility and range. In this study, we had designed the formulation of solid rocket propellants applied on 120mm rocket assisted projectile, and fabricated a prototype, and investigated feasibility of rocket assisted projectile for 120mm mortar results from static firing and flight test.

  • PDF

A study on manufacturing of laser welded tube from 60kgf/$mm^2$Grade Steel Sheet for one-body forming (60kgf/$mm^2$급 일체화 성형용 레이저 용접 튜브 제조에 관한 연구)

  • Seo, Jung;Lee, Je-Hoon;Kim, Jung-Oh;Kang, Hee-Sin;Lee, Mun-Yong;Jung, Byung-Hoon
    • Proceedings of the KWS Conference
    • /
    • 2003.11a
    • /
    • pp.18-20
    • /
    • 2003
  • Optimal processing and system to produce the laser welded tube for one body formed bumper beam are studied. The calculated size of tube is a thickness of 1.4mm, diameter of 105.4mm and length of 2000mm. The tube is shaped from cool rolled high strength steel sheet(tensile strength: 60kgf/$\textrm{mm}^2$ grade). Two roll bending method is the optimal tube shaping process compared to UO-bending, bending on press brake, multi-step continuous roll forming and 3 roll bending methods. Weld quality monitoring and seam tracking along the butt-joint lengthwise to the tube axis are also studied. The longitudinal butt-joint is welded by the $CO_2$ laser welding system equipped with a seam tracker and plasma sensor. The constructed $CO_2$ laser tube welding system can be used for the precision seam tracking and the real-time monitoring of weld quality. Finally, the obtained laser welded tube can be used for one-body formed automobile bumper beam.

  • PDF

Intercomparison of Wind and Air Temperature Fields of Meteorological Model for Forecasting Air Quality in Seoul Metropolitan Area (수도권지역 대기질 예측을 위한 기상장 모델의 바람장과 온도장 비교 연구)

  • Jeong, Ju-Hee;Kim, Yoo-Keun;Moon, Yun-Seob;Hwang, Mi-Kyoung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.6
    • /
    • pp.640-652
    • /
    • 2007
  • The MM5, RAMS and WRF, meteorological models have provided the dynamical parameters as inputs to air quality model. A major content of this study is that significant characteristics of three models for high-ozone occurrence analyze for surface wind and air temperature fields and compare with observation data in Seoul metropolitan area. An analysis of air temperature field revealed that location of core in high temperature of MM5 and WRF differed from that of RAMS. MM5 and WRF indicated high temperature in Seoul but RAMS represented it on the outskirts of Seoul. MM5 and WRF were underestimated maximum temperature during daytime but RAMS simulated similar value with observation data. Surface wind field with three models, it was shown many differences at horizontal distribution of wind direction. RAMS indicated weak wind speed in land and strong sea breeze at coastal areas than MM5 and WRF. However wind speed simulated by three model were overestimated during both daytime and nighttime.

A study on the bycatches by mesh size of spring-net-pot in Geo-je & Tong-young waters of Korea (거제·통영해역 스프링그물통발의 망목별 혼획 연구)

  • Cha, Bong-Jin;Cho, Sam-Kwang;Lee, Gun-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.3
    • /
    • pp.204-213
    • /
    • 2010
  • Test fishing was carried out using six kinds of different mesh sizes (20, 22, 24, 28, 35, 40mm) for springnet-pot to study bycatches according to the mesh size and catches survey was done for another one (mesh size : 22mm, entrance round : 350mm) in Geo-je & Tong-young waters of Korea. On the first sea experiment, it was thought that suitable mesh size of spring-net-pot catching conger-eel over 35cm with decreasing the catches of conger-eel (Conger myriaster) below 35cm was 24mm. On the second sea experiment, commercial catches were crabs (Charybdis bimaculata), octopus minor (Octopus variabilis) and others including conger-eel, and catches proportion was 60% of total catches weights. There was no big difference for the monthly catches. Self-consumption catches were 9 species including conger-eel below 35cm holding 50% of catches in the side of weights. There were 40% of bycatches for the catches weights and 63% for catches numbers in the 22mm mesh size of spring-net-pot having entrance round over 140mm. It showed that 50% of catches weights were discarded.

Effects of Base on Population Inversion in the DF Chemical Laser Cavity (불화중수소 화학레이저 공동 내에서의 분포역전에 대한 기저부의 영향)

  • 박준성;백승욱
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.83-86
    • /
    • 2003
  • The chemical laser system makes use of a diffusion type chemical reaction, so a fuel is separated from an oxidant by some gap, which is base in this system. In this study, the effects of base on the population inversion that is one of the most important things in the chemical laser system are numerically investigated. The results are discussed by comparison with three cases of base sizes; 0.4mm, 0.8mm and 1.6mm. Major results reveal that the range of population inversion also increases almost linearly in the transitions; DF$^{(2)}$ -DF$^{(1)}$ and DF$^{(3)}$ -DF$^{(2)}$ as the length of base becomes longer.

  • PDF

Production of Laser Welded Tube for Automobile Bumper Beam from 60kgf/$\textrm{mm}^2$Grade Steel Sheet (60kgf/$\textrm{mm}^2$급 자동차 범퍼빔용 레이저 용접 튜브 제조기술 및 장치연구)

  • Seo, Jung;Lee, Je-Hoon;Kim, Jong-Soo;Kim, Jung-O;Kang, Hee-Sin;Lee, Moon-Yong;Jung, Byung-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.7
    • /
    • pp.136-144
    • /
    • 2004
  • Optimal process and system to produce the laser welded tube for one body formed bumper beam are studied. The calculated size of tube is a thickness of 1.4mm, diameter of 105.4mm and length of 2000mm. The tube is shaped from a cold rolled high strength steel sheet(tensile strength: 60kgf/$\textrm{mm}^2$ grade). Two roll bending method is the optimal tube shaping process compared to UO-bending, bending on press brake, multi-step continuous roll forming and 3 roll bending methods. Weld quality monitoring and seam tracking along the butt-joint lengthwise to the tube axis are also studied. The longitudinal butt-joint is welded by the $CO_2$ laser welding system equipped with a seam tracker and plasma sensor. The constructed $CO_2$laser tube welding system can be used for the precision seam tracking and the real-time monitoring of weld quality. Finally, the obtained laser welded tube can be used for one-body formed automobile bumper beam.

Stress Analysis of Composite Double Lead Spiral in 20mm Universal Ammunition Loading System (20mm 범용탄약적재장비의 복합재 이중리드나선구조 설계)

  • Je, Hyun-Min;Kim, Wie-Dae
    • Composites Research
    • /
    • v.31 no.6
    • /
    • pp.340-346
    • /
    • 2018
  • This paper addresses the stress analysis and design of composite double lead spiral which is boarded in 20mm universal ammunition drum by finite element method. The spiral system is very important to transfer the ammunition in stable and reliable manners for aircraft. Some verifications are done to check the possibility of composite application in spiral system. The design variables, stacking sequence and fiber orientation angles, are investigated for reliable design for practical design. The Tsai-Wu failure theory is applied to see the safety of the spiral structure. The design result is suggested to manufacture the double lead spiral part.

Treatment Margin Assessment using Mega-Voltage Computed Tomography of a Tomotherapy Unit in the Radiotherapy of a Liver Tumor (간종양 방사선치료 시 토모테라피 메가볼트 CT를 이용한 치료 여백 평가)

  • You, Sei-Hwan;Seong, Jin-Sil;Lee, Ik-Jae;Koom, Woong-Sub;Jeon, Byeong-Chul
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.280-288
    • /
    • 2008
  • Purpose: To identify the inter-fractional shift pattern and to assess an adequate treatment margin in the radiotherapy of a liver tumor using mega-voltage computed tomography (MVCT) of a tomotherapy unit. Materials and Methods: Twenty-six patients were treated for liver tumors by tomotherapy from April 2006 to August 2007. The MVCT images of each patient were analyzed from the $1^{st}$ to the $10^{th}$ fraction for the assessment of the daily liver shift by four groups based on Couinard's proposal. Daily setup errors were corrected by bony landmarks as a prerequisite. Subsequently, the anterior-, posterior-, right-, and left shifts of the liver edges were measured by maximum linear discrepancies between the kilo-voltage computed tomography (KVCT) image and MVCT image. All data were set in the 2-dimensional right angle coordinate system of the transverse section of each patient's body. Results: The liver boundary shift had different patterns for each group. In group II (segment 2, 3, and 4), the anterior mean shift was $2.80{\pm}1.73\;mm$ outwards, while the left mean shift was $2.23{\pm}1.37\;mm$ inwards. In group IV (segment 7 and 8), the anterior-, posterior-, right-, and left mean shifts were $0.15{\pm}3.93\;mm$ inwards, $3.15{\pm}6.58\;mm$ inwards, $0.60{\pm}3.58\;mm$ inwards, and $4.50{\pm}5.35\;mm$ inwards, respectively. The reduced volume in group II after MVCT reassessment might be a consequence of stomach toxicity. Conclusion: Inter-fractional liver shifts of each group based on Couinard's proposal were somewhat systematic despite certain variations observed in each patient. The geometrical deformation of the liver by respiratory movement can cause shrinkage in the left margins of liver. We recommend a more sophisticated approach in free-breathing mode when irradiating the left lobe of liver in order to avoid stomach toxicity.

Design and Manufacture of LTE3G / WLAN/ LTE4G Tri-band Antenna System for Mobile Communication Applications

  • Bayarmaa., O;Hong, Yong Pyo;Kim, Kab Ki
    • International journal of advanced smart convergence
    • /
    • v.4 no.2
    • /
    • pp.29-33
    • /
    • 2015
  • In this paper, we propose the method to improve the performance of the antenna system that contains three bands, such as Lte3G, WLAN and Lte4G. This antenna has an advantage that can cover the three different frequency bands 2.1GHz, 2.4GHz and 2.6GHz through one antenna design. The design and simulations are done using CST Microwave Studio 2014 program. The antenna is designed by using the FR-4 (lossy) substrate with the dielectric constant of er=4.3 and dielectric loss tangent 0.025. The substrate dimensions are the following; Thickness[h] is 1.6mm, Length is 90mm, and Width is 40mm. The ground is designed by using the PEC material with h=0.035mm. The patch is designed by using the copper with h=0.035mm. In the near future, we will fabricate the antenna, which we have designed, and then apply this antenna to the mobile communication system. And we will test this mobile communication system for the diverse environments.

Development of Movable Detection System for Efficiency Measurement in 3-PM Liquid Scintillation Counting

  • Hwang, H-Y;Kwak, S.I;Cho, Y.H;Byun, J.I;Lee, H.Y;Seo, J.S;Kwak, J.Y;Lee, J.M;Lee, K.B;Park, T.S;Chung, K.H;Lee, C.W
    • Nuclear Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.165-170
    • /
    • 2003
  • We developed an improved 3-PM liquid scintillation counting (3-PM LSC) method in which three detectors can be displaced to back and forth directions, and a data acquisition system being able to provide the values for all parameters required for the method. The detectors are entirely located in a 20-mm lead chamber of an inner diameter of 500 mm. A saw-toothed gear ties up all detectors so as to move them uniformly, up to 50 mm with unit of 1 mm. The data acquisition system was designed in an integrated circuit to perform the necessary works such as fast amplification, discrimination, coincidence and logic analysis. It generates values of nine parameters among twelve's generated in the 3-PH LSC method. The dead time of each counting channel is of extending type, valving from 10 to 100 $mutextrm{s}$. We measured the TDCR values with an unquenched liquid scintillation source 1"C by displacing the detectors with a step of 2.5 mm away from counting vial. Their values were derived on the range from 0.9 to 0.6. The extent is three times wider than those regions observed by applying the defocalization technique.ique.