Abstract
Purpose: To identify the inter-fractional shift pattern and to assess an adequate treatment margin in the radiotherapy of a liver tumor using mega-voltage computed tomography (MVCT) of a tomotherapy unit. Materials and Methods: Twenty-six patients were treated for liver tumors by tomotherapy from April 2006 to August 2007. The MVCT images of each patient were analyzed from the $1^{st}$ to the $10^{th}$ fraction for the assessment of the daily liver shift by four groups based on Couinard's proposal. Daily setup errors were corrected by bony landmarks as a prerequisite. Subsequently, the anterior-, posterior-, right-, and left shifts of the liver edges were measured by maximum linear discrepancies between the kilo-voltage computed tomography (KVCT) image and MVCT image. All data were set in the 2-dimensional right angle coordinate system of the transverse section of each patient's body. Results: The liver boundary shift had different patterns for each group. In group II (segment 2, 3, and 4), the anterior mean shift was $2.80{\pm}1.73\;mm$ outwards, while the left mean shift was $2.23{\pm}1.37\;mm$ inwards. In group IV (segment 7 and 8), the anterior-, posterior-, right-, and left mean shifts were $0.15{\pm}3.93\;mm$ inwards, $3.15{\pm}6.58\;mm$ inwards, $0.60{\pm}3.58\;mm$ inwards, and $4.50{\pm}5.35\;mm$ inwards, respectively. The reduced volume in group II after MVCT reassessment might be a consequence of stomach toxicity. Conclusion: Inter-fractional liver shifts of each group based on Couinard's proposal were somewhat systematic despite certain variations observed in each patient. The geometrical deformation of the liver by respiratory movement can cause shrinkage in the left margins of liver. We recommend a more sophisticated approach in free-breathing mode when irradiating the left lobe of liver in order to avoid stomach toxicity.
Keywords
MVCT; Liver tumor; Tomotherapy;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Herfarth KK, Debus J, Lohr F, et al. Stereotactic singledose radiation therapy of liver tumors: results of a phase I/II trial. J Clin Oncol 2001;19:164-170   DOI
2 Baisden JM, Reish AG, Sheng K, Larner JM, Kavanagh BD, Read PW. Dose as a function of liver volume and planning target volume in helical tomotherapy, intensitymodulated radiation therapy-based stereotactic body radiation therapy for hepatic metastasis. Int J Radiat Oncol Biol Phys 2006;66:620-625   DOI   ScienceOn
3 Brock KM, Balter JM, Dawson LA, Kessler ML, Meyer CR. Automated generation of a four-dimensional model of the liver using warping and mutual information. Med Phys 2003;30:1128-1133   DOI
4 Brock KK, Sharpe MB, Dawson LA, Kim SM, Jaffray DA. Accuracy of finite element model-based multi-organ deformable image registration. Med Phys 2005;32:1647-1659   DOI   ScienceOn
5 Forrest LJ, Mackie TR, Ruchala K, et al. The utility of megavoltage computed tomography images from a helical tomotherapy system for setup verification purposes. Int J Radiat Oncol Biol Phys 2006;60:1639-1644
6 Wong JW, Sharpe MB, Jaffray DA, et al. The use of active breathing control (ABC) to reduce margin for breathing motion. Int J Radiat Oncol Biol Phys 1999;44:911-919   DOI   ScienceOn
7 Murphy MJ. Tracking moving organs in real time. Semin Radiat Oncol 2004;14:91-100   DOI   ScienceOn
8 Keall PJ, Kini VR, Vedam SS, et al. Motion adaptive x-ray therapy: a feasibility study. Phys Med Biol 2001;46:1-10   DOI   ScienceOn
9 Fuss M, Shi C, Papanikolaou N. Tomotherapeutic stereotactic body radiation therapy: techniques and comparison between modalities. Acta Oncologica 2006;45:953-960   DOI   ScienceOn
10 Shim SJ, Seong J, Lee IJ, Han KH, Chon CY, Ahn SH. Radiation-induced hepatic toxicity after radiotherapy combined with chemotherapy for hepatocellular carcinoma. Hepatol Res 2007;37:906-913   DOI   ScienceOn
11 Brock KK, Hollister SJ, Dawson LA, Balter JM. Technical note. Creating a four-dimensional model of the liver using finite element analysis. Med Phys 2002;29:1403-1405   DOI   ScienceOn
12 International Congress on Radiological Units Report 62. 1999
13 Seong J, Park HC, Han KH, et al. Local radiotherapy for unresectable hepatocellular carcinoma patients who failed with transcatheter arterial chemoembolization. Int J Radiat Oncol Biol Phys 2000;47:1331-1335   DOI   ScienceOn
14 Seong J, Park HC, Han KH, et al. Clinical results of 3- dimensional conformal radiotherapy combined with transcatheter arterial chemoembolization for hepatocellular carcinoma in the cirrhotic patients. Hepatol Res 2003;27:30-35   DOI   ScienceOn
15 Song WY, Chiu B, Bauman GS, et al. Prostate contouring uncertainty in megavoltage computed tomography images acquired with a helical tomotherapy unit during image-guided radiation therapy. Int J Radiat Oncol Biol Phys 2006;65:595-607   DOI   ScienceOn
16 Ramsey CR, Langen KM, Kupeian PA, et al. A technique for adaptive image-guided helical tomotherapy for lung cancer. Int J Radiat Oncol Biol Phys 2006;64:1237-1244
17 Rosenzweig KE, Yorke E, Amols H, et al. Tumor motion control in the treatment of non-small cell lung cancer. Cancer Invest 2005;23:129-133   DOI
18 Wulf J, Hadinger U, Oppitz U, Thiele W, Flentie M. Stereotactic radiotherapy of targets in the lung and liver. Strahlenther Onkol 2001;177:645-655   DOI
19 Balter JM, Brock KK, Lam KL, et al. Evaluating the influence of setup uncertainties on treatment planning for focal liver tumors. Int J Radiat Oncol Biol Phys 2005;63:610-614   DOI   ScienceOn
20 Meeks SL, Harmon JF, Langen KM, Willoughby TR, Wagner TH, Kupelian PA. Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit. Med Phys 2005;32:2673-2681   DOI   ScienceOn
21 Mackie TR, Kapatoes J, Ruchala K, et al. Image guidance for precise conformal radiotherapy. Int J Radiat Oncol Biol Phys 2003;56:89-105   DOI   ScienceOn
22 Neicu T, Shirato H, Seppenwoolde Y, et al. Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients. Phys Med Biol 2003;48:587-598   DOI   ScienceOn
23 Brock KK, McShan DL, Haken RT, Hollister SJ, Dawson LA, Balter JM. Inclusion of organ deformation in dose calculations. Med Phys 2003;30:290-295   DOI   ScienceOn
24 Langet KM, Jones DT. Organ motion and its management. Int J Radiat Oncol Biol Phys 2001;50:265-278   DOI   ScienceOn
25 Seong J, Park HC, Han KH, Chon CY. Clinical results and prognostic factors in radiotherapy for unresectable hepatocellular carcinoma: a retrospective study of 158 patients. Int J Radiat Oncol Biol Phys 2002;55:329-336
26 Yan D, Lockman D, Brabbins D, Tyburski L, Martinez A. An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer. Int J Radiat Oncol Biol Phys 2000;48:289-302   DOI   ScienceOn
27 Hodge W, Tome W, Jaradat HA, et al. Feasibility report of image guided stereotactic body radiotherapy (IG-SBRT) with tomotherapy for early stage medically inoperable lung cancer using extreme hypofractionation. Acta Oncologica 2006;45:890-896   DOI   ScienceOn
28 Park HC, Seong J, Han KH, Chon CY, Moon YM, Suh CO. Dose-response relationship in local radiotherapy for hepatocellular carcinoma. Int J Radiat Oncol Biol Phys 2002;54:150-155