• Title/Summary/Keyword: MLC

Search Result 320, Processing Time 0.021 seconds

A Monitor Unit Verification Calculation in IMRT as a Dosimetry QA

  • Kung, J.H.;Chen, G.T.Y.;Kuchnir, F.T.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.68-73
    • /
    • 2002
  • In standard teletherapy, a treatment plan is generated with the aid of a treatment planning system, but it is common to perform an independent monitor unit verification calculation (MUVC). In exact analogy, we propose and demonstrate that a simple and accurate MUVC in Intensity Modulated Radiotherapy (IMRT) is possible. We introduce a concept of Modified Clarkson Integration (MCI). In MCI, we exploit the rotational symmetry of scattering to simplify the dose calculation. For dose calculation along a central axis (CAX), we first replace the incident IMRT fluence by an azimuthally averaged fluence. Second, the Clarkson Integration is carried over annular sectors instead of over pie sectors. We wrote a computer code, implementing the MCI technique, in order to perform a MUVC for IMRT purposes. We applied the code to IMRT plans generated by CORVUS. The input to the code consists of CORVUS plan data (e.g., DMLC files, jaw settings, MU for each IMRT field, depth to isocenter for each IMRT field), and the output is dose contribution by individual IMRT field to the isocenter. The code uses measured beam data for Sc, Sp, TPR, (D/Mu)$\_$ref/ and includes effects from MLC transmission, and radiation field offset. On a 266 MHZ desktop computer, the code takes less than 15 sec to calculate a dose. The doses calculated with MCI algorithm agreed within +/- 3% with the doses calculated by CORVUS, which uses a 1cm x 1cm pencil beam in dose calculation. In the present version of MCI, skin contour variations and inhomogeneities were neglected.

  • PDF

The Design of 2.4 GHz Band LTCC Bandpass Filter using $\lambda$/4 Hairpin Resonators ($\lambda$/4 Hairpin 공진기를 이용한 2.4 GHz 대역 LTCC 대역통과 필터의 설계)

  • Sung Gyu-Je
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.4 s.33
    • /
    • pp.7-11
    • /
    • 2004
  • In this paper, a $\lambda$/4 hairpin resonator is applied to reduce the size of planar resonators for a 2.4 GHz Band LTCC MLC bandpass filter. The $\lambda$/4 hairpin resonator operates as stepped impedance resonator (SIR) without changing the width of the planar resonator. It is composed of two sections those are parallel coupled line and transmission line. The characteristic impedance of two sections is different each other. The design formulas of the bandpass filter using the coupling element at the arbitrary position are derived from even and odd-mode analysis. The formulas can take account of the arbitrary coupling of lumped and/or distributed resonators. The advantage of this filter is its abilities to change freely the coupling structure between two resonators. Experimental bandpass filters for 2.4 GHz Band are implemented and their performances are shown.

  • PDF

Calculation of Dose Distribution for SBRT Patient Using Geant4 Simulation Code (Geant4 전산모사 코드를 이용한 SBRT 환자의 선량분포 계산)

  • Kang, Jeongku;Lee, Jeongok;Lee, Dong Joon
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.36-41
    • /
    • 2015
  • The Monte Carlo based dose calculation program for stereotactic body radiotherapy was developed in this study. The Geant4 toolkit widely used in the radiotherapy was used for this study. The photon energy spectrum of the medical linac studied in the previous research was applied for the patient dose calculations. The geometry of the radiation fields defined by multi-leaf collimators were taken into account in the PrimaryGeneratorAction class of the Geant4 code. The total of 8 fields were demonstrated in the patient dose calculations, where rotation matrix as a function of gantry angle was used for the determination of the source positions. The DicomHandler class converted the binary file format of the DICOM data containing the matrix number, pixel size, endian type, HU number, bit size, padding value and high bits order to the ASCII file format. The patient phantom was constructed using the converted ASCII file. The EGSnrc code was used to compare the calculation efficiency of the material data.

Assessing the Extent and Rate of Deforestation in the Mountainous Tropical Forest

  • Pujiono, Eko;Lee, Woo-Kyun;Kwak, Doo-Ahn;Lee, Jong-Yeol
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.3
    • /
    • pp.315-328
    • /
    • 2011
  • Landsat data incorporated with additional bands-normalized difference vegetation index (NDVI) and band ratios were used to assess the extent and rate of deforestation in the Gunung Mutis Nature Reserve (GMNR), a mountainous tropical forest in Eastern of Indonesia. Hybrid classification was chosen as the classification approach. In this approach, the unsupervised classification-iterative self-organizing data analysis (ISODATA) was used to create signature files and training data set. A statistical separability measurement-transformed divergence (TD) was used to identify the combination of bands that showed the highest distinction between the land cover classes in training data set. Supervised classification-maximum likelihood classification (MLC) was performed using selected bands and the training data set. Post-classification smoothing and accuracy assessment were applied to classified image. Post-classification comparison was used to assess the extent of deforestation, of which the rate of deforestation was calculated by the formula suggested by Food Agriculture Organization (FAO). The results of two periods of deforestation assessment showed that the extent of deforestation during 1989-1999 was 720.72 ha, 0.80% of annual rate of deforestation, and its extent of deforestation during 1999-2009 was 1,059.12 ha, 1.31% of annual rate of deforestation. Such results are important for the GMNR authority to establish strategies, plans and actions for combating deforestation.

Improved Algorithm of Hybrid c-Means Clustering for Supervised Classification of Remote Sensing Images (원격탐사 영상의 감독분류를 위한 개선된 하이브리드 c-Means 군집화 알고리즘)

  • Jeon, Young-Joon;Kim, Jin-Il
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.185-191
    • /
    • 2007
  • Remote sensing images are multispectral image data collected from several band divided by wavelength ranges. The classification of remote sensing images is the method of classifying what has similar spectral characteristics together among each pixel composing an image as the important algorithm in this field. This paper presents a pattern classification method of remote sensing images by applying a possibilistic fuzzy c-means (PFCM) algorithm. The PFCM algorithm is a hybridization of a FCM algorithm, which adopts membership degree depending on the distance between data and the center of a certain cluster, combined with a PCM algorithm, which considers class typicality of the pattern sets. In this proposed method, we select the training data for each class and perform supervised classification using the PFCM algorithm with spectral signatures of the training data. The application of the PFCM algorithm is tested and verified by using Landsat TM and IKONOS remote sensing satellite images. As a result, the overall accuracy showed a better results than the FCM, PCM algorithm or conventional maximum likelihood classification(MLC) algorithm.

  • PDF

Assessment of the Optic-guided Patient Positioning for Spinal Stereotactic Radiosurgery Using Novalis ExacTrac System (노발리스 ExacTrac system을 이용한 척추 정위 방사선수술 방법 평가)

  • 이동준;손문준;최광영;이기택;최찬영;황금철;황충진
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.218-223
    • /
    • 2002
  • Stereotactic radiosurgery for intracranial lesion is well established since the Lars Leksell first introduced radiosurgery concept in 1951 Its use in the treatment of spinal lesion has been limited by the availability of effective immobilization devices. The first clinical experience of the spinal stereotactic radiosurgery technique was reported by Hamilton AJ. in 1995. Recently, Optic-guided patient positioning technique for extracranial stereotactic radiosurgery was developed and reported. This study is for assess the target positioning accuracy of the optic guided patient positioning system Exactrac (BrainLab., Inc, Germany). We have designed phantom for assess the accuracy of spinal stereotactic radiosurgery The infrared reflective body markers attached to the relatively immobile part of the body and a series of 2 mm CT images was taken. The image sets were transferred to the planning computer. During the radiosurgery treatment, we measure the real-time display showing the positioning values from Exactrac computer. And we compare the isocenter deviation from irradiated center point of the film which was mounted on the lesion site of the phantom and pin hole site of that film. The accuracy of the ExacTrac system in positioning a target point shows enough for the clinical applications.

  • PDF

A Study on the Preparation Method of Fruit Cropping Distribution Map using Satellite Images and GIS (위성영상과 GIS를 이용한 과수재배 분포도 작성 기법에 관한 연구)

  • Jo, Myung-Hee;Bu, Ki-Dong;Lee, Jung-Hyoup;Lee, Kwang-Jae
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.3 no.4
    • /
    • pp.73-86
    • /
    • 2000
  • This study focused on extracting an efficient method in the fruit cropping distribution mapping with various classification methods using multi-temporal satellite images and Geographic Information Systems(GIS). For this study, multi-temporal Landsat TM images, in observation data and existing fruit cropping area statistics were used to compare and analyze the properties of fruit cropping and seasonal distribution per classification method. As a result, this study concludes that Maximum Likelihood Method with earlier autumn satellite image was most efficient for the fruit cropping mapping using Landsat TM image. In addition, it was clarified that cropping area per administrative boundary was prepared and distribution pattern was identified efficiently using GIS spatial analysis.

  • PDF

A High Performance Co-design of 26 nm 64 Gb MLC NAND Flash Memory using the Dedicated NAND Flash Controller

  • You, Byoung-Sung;Park, Jin-Su;Lee, Sang-Don;Baek, Gwang-Ho;Lee, Jae-Ho;Kim, Min-Su;Kim, Jong-Woo;Chung, Hyun;Jang, Eun-Seong;Kim, Tae-Yoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.2
    • /
    • pp.121-129
    • /
    • 2011
  • It is progressing as new advents and remarkable developments of mobile device every year. On the upper line reason, NAND FLASH large density memory demands which can be stored into portable devices have been dramatically increasing. Therefore, the cell size of the NAND Flash memory has been scaled down by merely 50% and has been doubling density each per year. [1] However, side effects have arisen the cell distribution and reliability characteristics related to coupling interference, channel disturbance, floating gate electron retention, write-erase cycling owing to shrinking around 20nm technology. Also, FLASH controller to manage shrink effect leads to speed and current issues. In this paper, It will be introduced to solve cycling, retention and fail bit problems of sub-deep micron shrink such as Virtual negative read used in moving read, randomization. The characteristics of retention, cycling and program performance have 3 K per 1 year and 12.7 MB/s respectively. And device size is 179.32 $mm^2$ (16.79 mm ${\times}$ 10.68 mm) in 3 metal 26 nm CMOS.

A Study of Runoff Curve Number Estimation Using Land Cover Classified by Artificial Neural Networks (신경망기법으로 분류한 토지피복도의 CN값 산정 적용성 검토)

  • Kim, Hong-Tae;Shin, Hyun-Suk
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.4
    • /
    • pp.633-645
    • /
    • 2003
  • The techniques of GIS and remote sensing are being applied to hydrology, geomorphology and various field of studies are performed by many researcher, related those techniques. In this paper, curve number change detection is tested according to soil map and land cover in mountain area. Neural networks method is applied for land cover classification and GIS for curve number calculation. The first, sample area are selected and tested land cover classification, NN(84.1%) is superior to MLC(80.9%). So we selected NN with land cover classifier. The second, curve number from the land cover by neural network classifier(57) is compared with that(curve number) from the land cover by manual work(55). Two values are so similar. The third, curve number classified by NN in sample area was applied and tested to whole study area. As results of this study, it is shown that curve number is more exact and efficient by using NN and GIS technique than by (using) manual work.

Evaluation of Beam-Matching Accuracy for 8 MV Photon Beam between the Same Model Linear Accelerator (동일 기종 선형가속기간 8 MV 광자선에 대한 빔 매칭 정확도 평가)

  • Kim, Yon-Lae;Chung, Jin-Beom;Kang, Seong-Hee
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.105-114
    • /
    • 2020
  • This study aimed to assess of beam-matching accuracy for an 8 MV beam between the same model linear accelerators(Linac) commissioned over two years. Two models were got the customer acceptance procedure(CAP) criteria. For commissioning data for beam-matched linacs, the percentage depth doses(PDDs), beam profiles, output factors, multi-leaf collimator(MLC) leaf transmission factors, and the dosimetric leaf gap(DLG) were compared. In addition, the accuracy of beam matching was verified at phantom and patient levels. At phantom level, the point doses specified in TG-53 and TG-119 were compared to evaluate the accuracy of beam modelling. At patient level, the dose volume histogram(DVH) parameters and the delivery accuracy are evaluated on volumetric modulated arc therapy(VMAT) plan for 40 patients that included 20 lung and 20 brain cases. Ionization depth curve and dose profiles obtained in CAP showed a good level for beam matching between both Linacs. The variations in commissioning beam data, such as PDDs, beam profiles, output factors, TF, and DLG were all less than 1%. For the treatment plans of brain tumor and lung cancer, the average and maximum differences in evaluated DVH parameters for the planning target volume(PTV) and the organs at risk(OARs) were within 0.30% and 1.30%. Furthermore, all gamma passing rates for both beam-matched Linacs were higher than 98% for the 2%/2 mm criteria and 99% for the 2%/3 mm criteria. The overall variations in the beam data, as well as tests at phantom and patient levels remains all within the tolerance (1% difference) of clinical acceptability between beam-matched Linacs. Thus, we found an excellent dosimetric agreement to 8 MV beam characteristics for the same model Linacs.