Abstract
The Monte Carlo based dose calculation program for stereotactic body radiotherapy was developed in this study. The Geant4 toolkit widely used in the radiotherapy was used for this study. The photon energy spectrum of the medical linac studied in the previous research was applied for the patient dose calculations. The geometry of the radiation fields defined by multi-leaf collimators were taken into account in the PrimaryGeneratorAction class of the Geant4 code. The total of 8 fields were demonstrated in the patient dose calculations, where rotation matrix as a function of gantry angle was used for the determination of the source positions. The DicomHandler class converted the binary file format of the DICOM data containing the matrix number, pixel size, endian type, HU number, bit size, padding value and high bits order to the ASCII file format. The patient phantom was constructed using the converted ASCII file. The EGSnrc code was used to compare the calculation efficiency of the material data.
Keywords
Monte Carlo; dicom; SBRT; Geant4;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Leksell L: Stereotactic radiosurgery. J Neuosurg Psychiatr 46: 797-803 (1983)   DOI
2 Kang JK, Lee DJ: Development of Monte Carlo Code for the Dose Calculation of the Stereotactic Radiosurgery. Progress in Medical Physics 23(4):303-308 (2012)
3 Rogers DWO: BEAM: A Monte Carlo code to simulate radiotherapy treatment units. Med Phys 22(5):503 (1995)   DOI
4 Fippel M, Laub W, Huber B, Nusslin F: Experimental investigation of a fast Monte Carlo photon beam dose calculation algorithm. Phys Med Biol 44(12):3039-3054 (1999)   DOI
5 Fippel M, Kawrakow I, Friedrich K: Electron beam dose calculations with the VMC algorithm and the verification data of the NCI working group. Phys Med Biol 42(3):501-520 (1997)   DOI
6 Fippel M, Haryanto F, Dohm O, Nusslin F, Kriesen S: A virtual photon energy fluence model for Monte Carlo dose calculation. Med Phys 30(3):301 (2003)   DOI
7 Fippel M: Efficient particle transport simulation through beam modulating devices for Monte Carlo treatment planning. Med Phys 31(5):1235 (2004)   DOI
8 Kawrakow I, Fippel M: Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMC. Phys Med Biol 45(8):2163-2183 (2000)   DOI
9 Schneider W, Bortfeld T, Schlegel W: Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions. Phys Med Biol 45(2):459-478 (2000)   DOI
10 Kim HD, Kim BY, Kim EC, Yun SM, Kang JK, Kim SK: Comparison of dose distributions for Hounsfield number conversion methods in GEANT4. J Korean Phys Soc 64(12):1912-1918 (2014)   DOI
11 ICRU Report 46: Photon, Electron, Proton and Neutron Interaction Data for Body Tissues, Bethesda, MD (1992)