• Title/Summary/Keyword: ML 검출

Search Result 521, Processing Time 0.039 seconds

Separation of Lentil Lectin Using Free-Flow Electrophoresis (자유유동 전기이동을 이용한 Lentil Lectin의 분리)

  • 류화원;이동일장호남
    • KSBB Journal
    • /
    • v.9 no.2
    • /
    • pp.115-121
    • /
    • 1994
  • A Purification device with 30-channel free-flow electrophoresis was assembled to treat samples of 240m1 volume for purification of lentil lectin (LcH) from lentil seeds with no impurities in a silverstained PAGIEF gel. HEPES(50mM)-Ttis(50mM), Cycloserine(50mM)-urea(3M), Histidine(50mM)-urea(3M) were used as ampholytea among which Histidine(50mM)-urea(3M) (pI 7.65) was found best in resolution. LcH is known to be present in the form of LcH-A, LcH-B and the complex of the two. The complex, however, disappeared when urea was added in the ampholytes, which suggested that the complete purification of two isolectins is possible using the present multistep purificaton device.

  • PDF

Occurrence of Meloidogyne hapla in Peony Fields (작약 재배지에서 당근뿌리혹선충 발생양상)

  • 박소득;김기재;김정혜;유오종;류정기
    • Korean journal of applied entomology
    • /
    • v.37 no.2
    • /
    • pp.123-125
    • /
    • 1998
  • In peony fields located in Uisong and Yeongcheon distribution of Meloidogyne hapla was examined. Of 131 fields examined, M. hapla was isolated from 102 fields. In 57.8% of the infested fields, M. hapla density was higher 31 larvae1300 ml soil, the larval density isolated from upland fields were higher than those from paddy fields. Sandy loam soil harbored higher number of larvae than clay soil. Physio-chemical properties of soil might affect nematode population: High larval density was detected from those fields with low contents of OM, K+ and low pH. Fields infested with high larval densities required more lime than those with low or non infested fields.

  • PDF

Development of Measurement System for Industrial Transportable Gamma Ray CT (이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

Fabrication of Fiber Gas Sensor and Analysis of NOx Gas Detection Characteristics (화이버 가스 센서 제작 및 NOx 가스 검출 특성 분석)

  • Son, Ju Hyeong;Kim, Hyun Soo;Yoon, Young Ki;Jang, Kyung Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.5
    • /
    • pp.432-436
    • /
    • 2019
  • In this study, we produced a light, flexible, wearable gas sensor by depositing MWCNTs (Multi-walled Carbon Nanotubes) into nylon. MWCNTs are widely used as a gas sensor material due to their excellent mechanical, electrical and physical characteristics. We produced a gas sensor to detect NOx gases by depositing nylon yarn in a MWCNT solution. The MWCNT solution was made by mixing 3 mg MWCNT in 5 ml of ethanol. Nylon yarn was placed in the manufactured solution and ultrasonic waves were applied using an ultrasonicator for 3 h, resulting in MCWNT deposition. The MWCNT-deposited nylon yarn was dried at room temperature for 24 h. The MWCNT-thin-film-coated nylon yarn was masked 1 mm apart, and gold was then deposited on the masked nylon yarn to create the gas sensor. The sensor then was installed in a chamber with a controlled atmospheric environment and exposed to NOx gas. The changing signal from the sensor was amplified to analyze its gas detection characteristics.

Microfluidic Immuno-Sensor Chip using Electrical Detection System (전기 검출 시스템을 이용한 Microfluidic Immuno-Sensor Chip)

  • Maeng, Joon-Ho;Lee, Byung-Chul;Cho, Chul-Ho;Ko, Yong-Jun;Ahn, Yoo-Min;Cho, Nahm-Gyoo;Lee, Seoung-Hwan;Hwang, Seung-Yong
    • KSBB Journal
    • /
    • v.21 no.5
    • /
    • pp.325-330
    • /
    • 2006
  • This study presents the characterization of an integrated portable microfluidic electrical detection system for fast and low volume immunoassay using polystyrene microbead, which are used as immobilization surfaces. In our chip, a filtration method using the microbead was adopted for sample immobilization and immunogold silver staining(IGSS) was used to increase the electrical signal. The chip is composed of an inexpensive and biocompatible Polydimethylsiloxane(PDMS) layer and Pyrex glass substrate. Platinum microelectrodes for electric signal detection were fabricated on the substrate and microchannel and pillar-type microfilters were formed in the PDMS layer. With a fabricated chip, we reacted antigen and antibody according to the procedures. Then, silver enhancer was injected to increase the size of nanogold particles tagged with the second antibody. As a result, microbeads were connected to each other and formed an electrical bridge between microelectrodes. Resistance measured through the electrodes showed a difference of two orders of magnitude between specific and nonspecific immuno-reactions. The detection limit was 10 ng/ml. The developed immunoassay chip reduced the total analysis time from 3 hours to 50 min. Fast and low-volume biochemical analysis has been successfully achieved with the developed microfilter and immuno-sensor chip, which is integrated to the microfluidic system.

Environmental Microbial Assessment of Food Services at Elementary Schools in Western Gyeongnam Pyovince (서부 경남 지역 초등학교 급식소에서의 환경미생물 평가)

  • 박선자;하광수;심원보;박민경;정덕화
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.1
    • /
    • pp.14-24
    • /
    • 2003
  • Two aims of the present study were the evaluation of hygienic, microbial safety on food services of elementary schools in Western Gyeongnam province, and then, the construction of database for the SSOP (Sanitation Standard Operation Procedures) practice. A total of 98 samples were collected from drinking water, waterworks, kitchen utensils, kitchen equipments, employees and cooked foods. Total bacteria was counted and pathogenic bacteria such E. coli, salmonella, yersinia, vibrio parahaemolyticus and staphylococcus were identified based on the biochemical analysis. Following are the results: the number of bacteria showed from 1.0x10$^2$CFU/ mL to 1.0x10$^{6}$ CFU/mL in most samples, which the level exceeds normal range. Over 1.0x10$^{5}$ CFU/ml bacteria were observed from the kimchi in 4 places (B, C, D, E), because cooked food such as kimchi had not been heated. As a rule, the bacterium level in place B was higher than that in any of the other places. E-coli were isolated from kitchen knives (C, E) and Kimchi (E): staphylococci were isolated from drinking water (A), hands (D), refrigerator (E) and apron (E). But, salmonella, vibrio and yersinia were not detected in anywhere. In conclusion, the presence of bacteria and pathogenic agents in school food service was closely related to hygienic practice. For that reason, it is necessary to have more systematic and efficient management in order to enhance the food safety.

Detection of Mycobacterium Tuberculosis by In Situ Hybridization (조직내교잡법을 이용한 결핵균의 검출)

  • Park, Chang-Soo;Kim, Young-Chul;Lee, Jee-Shin;Jung, Jong-Jae;Kim, Doo-Hong;Kim, Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.699-708
    • /
    • 2000
  • Background : A presumptive histopathologic diagnosis of tuberculosis is commonly based on the finding of acid-fast bacilli upon microscopic examination of a diagnostic specimens. Although this traditional histochemical staining method is satisfactory, it is time-consuming and not species-specific. For more specific assessment, in situ hybridization assay with oligonucleotide probes is introduced. Methods : The human surgical specimens were obtained from tuberculosis patients, and experimental specimens were made by injecting cultured M. tuberculosis organisms into fresh rat liver. Oligonucleotide probes complementary to ribosomal RNA portion were synthesized and labeled with multiple biotin molecules. For a rapid detection, all procedures were carried out using manual capillary action technology on the Microprobe staining system. Results : The in situ hybridization assay produced a positive reaction in experimental specimens (80-90% sensitivity) after pepsin-HCl pre-treatment for a good permeabilization of probes, but reliable result was not obtained from human surgical specimens. Conclusion : It is, therefore, suggested that biotin-labeled oligonucleotide probes have considerable potential for identification and in situ detection of M. tuberculosis but, there are some barriers to overcome for the diagnostic use of this method.

  • PDF

Analysis of nutritional contents and physiological activities of Neolentinus lepideus (잣버섯의 영양 성분 및 생리 활성 분석)

  • Jung, Hyesun;Park, Yena;Yoo, Young-Bok;Jeon, Dae-Hoon;Park, Ki-Moon
    • Journal of Mushroom
    • /
    • v.11 no.4
    • /
    • pp.261-268
    • /
    • 2013
  • This study was conducted to investigate the physiological activities and nutrition contents of Gonji No.10 and Solhyang, the strains of Neolentinus lepideus. In nutritional contents of two strains of N. lepideus, the content of free sugars and sugar alcohols and total polyphenol were more in Gonji No.10 than Solhyang. The total contents of amino acids and ${\beta}$-glucan in Solhyang are more than those in Gonji No.10. Solhyang also showed higher DPPH radical scavenging activity than Gonji No.10. In particular, hot water extract of Solhyang has higher inhibitory activity of ${\alpha}$-amylase and ${\alpha}$-amyloglucosidase while Gonji No.10 has higher anti-inflammatiory effect than Solhyang. But, they have similar effects on nitrite scavenging activity.

Determination of Volatile Organic Compounds emitted from Municipal Solid Waste Landfill Site by Thermal Desorption-Cryofocusing-GC/FID/FPD (열탈착-저온농축-GC/FID/FPD에 의한 도시 생활폐기물 매립장에서 방출되는 휘발성 유기화합물의 측정에 관한 연구)

  • Kim, Man-Goo;Jung, Young-Rim;Seo, Young-Min;Nam, Sung-Hyun;Kwon, Young-Jin
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.274-285
    • /
    • 2001
  • In this study, the thermal desorption-cryofocusing-gas chromatographic(TD-C-GC) method was developed for determination of volatile organic compounds(VOCs) in ambient air and was applied at the municipal solid waste landfill sites. On-column cryofocusing was possible only with a 100 ml dewars bottle in TD-C-GC method with a stainless steel column. However, high operating pressure was needed for purging VOCs from the absorbent trap, which was able to solve by pressure programming with a electric pressure controller. By using both pressure and temperature programming brought increasing of resolution power in on-column cryofocusing method, but the high pressure caused a leakage of sample tube with repeated use. A loop cryofocusing devise was also developed and compared with the direct on-column method. In loop cryofocusing method, VOCs were concentrated on a 0.8mm i.d. loop which is located between the injector and separation column by using liquid nitrogen. In order to purge VOCs from the absorbent trap, only 0.4 psi of pressure was need in the loop cryofocusing method. Dual detection system was applied for the analysis of VOCs; a FID was used for hydrocarbons and a FPD was used for sulfur-containing compounds. Qualitative analysis was done by on-column cryofocusing GC-MS system. Among the large number of VOCs, toluene was the most abundant. Hydrogen sulfide, dimethyl sulfide, carbon disulfide, dimethyl disulfide and methyl propyl disulfide were detected at landfill site by FPD.

  • PDF

Rapid Analytical Method of Volatile- and Semivolatile Organic Compounds in Water and their Monitoring in Water Treatment Plants (물 시료 중 휘발성 및 반휘발성 유기물질들의 빠른 분석법 및 정수처리 단계별 모니터링)

  • Shin, Ho-Sang;Ahn, Hye-Sil
    • Analytical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.240-250
    • /
    • 2004
  • A gas chromatography-mass spectrometric (GC-MS) assay method was developed for the rapid and sensitive determination of volatile- and semivolatile organic compounds in water. Two hundreds mL of water sample was extracted in a 250 mL separatory funnel with 1 ml of pentane at pH 6.5. Fluorobenzene and 1,2-dichlorobenzene-d4 as internal standards were added to water sample and the solution was mechanically shaken for 5 min and analyzed by GC-MS (selected ion monitoring) without more any concentration or purification steps. The peaks had good chromatographic properties and the extraction of these compounds from water also gave relatively high recoveries with small variations. The range of detection limits of the assay was 0.5-10 ng/L. Turnaround time for up to about 40 samples was one day. This method is simple, convenient, and can be learned easily by relatively inexperienced personnel. This method was used to analyze 15 volatile- and semivolatile organic compounds in water of a Lake, and raw and treated water from three Water Treatment Plants in Korea. As the analytical results, benzene, toluene, xylene, isopropylbenzene, 1,3,5-trimethylbenzene, 1,2,4-trimethylbenzene, naphthalene and 2,4,6-trichlorophenol were detected at concentrations of up to 0.4, 1.9, 1.3, 0.2, 1.8, 13.0, 1.7 and $1.1{\mu}g/L$, respectively. But chlorobenzene, trichloroethylene, tetrachloroethylene, ethylbenzene, n-butylbenzene and dibromochloropropane levels during that period were not significant. The removal effect of the compounds in three Water Treatment Plants was calculated. The compounds studied were generally removed during conventional water treatment, especially during the active carbon filtration.