• 제목/요약/키워드: MIS 4

Search Result 425, Processing Time 0.03 seconds

Characteristics of Marine Terrace Sediments Formed during the Marine Isotope Stage 5e in the West South Coast of the Korean Peninsula (한반도 서남해안 MIS 5e 해안단구의 퇴적층 특성 연구)

  • Yang, Dong-Yoon;Han, Min;Kim, Jin Cheul;Lim, Jaesoo;Yi, Sangheon;Kim, Ju-Yong
    • Economic and Environmental Geology
    • /
    • v.49 no.6
    • /
    • pp.417-432
    • /
    • 2016
  • It was firstly revealed in this research that the marine terrace of the Ijin-ri (Bukpyung-myeon, Haenam-gun) was formed during the last interglacial (Marine Isotope Stage 5e; MIS 5e). The marine terrace totally ranging from 4.8 m (asl) to 8.8 m (asl) is subdivided into 4 units; Unit I ranges 4.8-5.3 m, unit II ranges 5.3-6.9 m, unit III ranges 6.9-8.3 m, and unit IV ranges 8.3-8.8 m. Strong evidences that units II and III were formed during MIS5e were obtained based on OSL dating, the physical characterizations such as particle size distribution, magnetic susceptibility and water content, principal element and trace element analyses, and quantitative clay mineral analysis for samples at the 30 cm intervals. The rounded gravels on the marine terrace are regarded to be originated from the clastic materials transported directly from the surrounding mountains toward the marine and abraded in the coastal area, without any fluvial processes. During the warmest period (125k, unit II), the increase in rainfall, along with the rapid rise in sea level, was likely caused the high amount of clastic materials transported to the upper part of the beach. As a result of comparing clay mineral ratios of study site with those derived from sediments of either tidal flats, or the Yellow Sea, it is interpreted that the sediments of study site were influenced from the marine. The results will be used to investigate the hydrological activity and sedimentary environment during the high sea level in the past.

Electrical Characteristic of AI/AIN/GaAs MIS capacitor Fabricated by Reactive Sputtering Method for the (NH4)2S Treatment (반응성 스퍼터링법으로 AI/AIN/GaAs 커패시터 제조시 (NH4)2S 처리에 따른 전기적 특성)

  • Chu, Soon-Nam;Kwon, Jung-Youl;Park, Jung-Cheul;Lee, Heon-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.1
    • /
    • pp.8-13
    • /
    • 2007
  • In MIS capacitor structure, we have studied the electrical properties in Ammonium Sulfide solution treatment while AIN thin film as a insulator is being formed by reactive sputtering method. The deposition process conditions of AIN thin film we temperature $250^{\circ}C$, DC Power 150 W, pressure 5 mTorr and 8 sccm(Ar : 4 sccm, $N_{2}$ : 4 sccm). The surface of GaAs was treated with Ammonium Sulfide solution, it was shown the leakage current was less than $10^{-8}\;A/cm^{2}$. The deep depletion phenomena of inverse area with treating Ammonium Sulfide solution in C-V analysis was improved as compared the condition of without Ammonium Sulfide solution and hysteresis property as well.

The Geomorphological Development of Coastal Terraces at Jigyeong-Ri, the Areal Boundary between Gyeongju- and Ulsan Cities on the Southeast Coast of Korea

  • Hwang, Sang-Ill;Yoon, Soon-Ock;Park, Han-San
    • The Korean Journal of Quaternary Research
    • /
    • v.17 no.2
    • /
    • pp.169-170
    • /
    • 2003
  • The existence of coastal terraces, HH(High higher) surfaces found at Gampo of southeast coast and at Jeongdongjin of the central east coast were confirmed at Jigyeong-Ri, the areal border between Gyeongju- and Ulsan city on the southeast coast of Korea Peninsula. Especially this study reports HH JK-surface located on the 155m a.s.l., which is the highest altitude among the ancient shorelines of the coastal terraces in Korea. The HH surfaces on the study area are classified into HH JK at 155m, HH-I at 140m and HH-II at 115m, and each formation stage is related to MIS 17(720∼690ka BP), MIS 15(630∼560ka BP) and MIS 13(510∼480ka BP) respectively. The HH-surfaces remain to be larger than those of H- and L-surfaces. The reason is caused by the unique factors of the coastal geology and morphology on the study area during the formation stage. And also the areal difference by the magnitude of upheaval doesn't exist from north to south because the altitude system of ancient shoreline on each coastal terrace is same along the east coast. The upheaval rate of the eastern coastal areas was measured in the relation to the ancient shoreline and formation stage among the coastal terraces such as HH JK-, HH-I, HH-II, H-III and H-IY surface, and was almost same as 0.23mm/y.

  • PDF

Analysis of Permeation Efficiency in Soil for OPC and Non-Pollution MIS Grouts by Laboratory Model Test (실내모형시험을 통한 OPC와 친환경 MIS 그라우트의 지반 침투성능 분석)

  • Ahn, Jung-Ho;Lim, Heui-Dae;Choi, Dong-Nam;Song, Young-Su
    • Economic and Environmental Geology
    • /
    • v.45 no.3
    • /
    • pp.307-315
    • /
    • 2012
  • In this paper, a laboratory model test was conducted to evaluate grouting efficiency of ordinary portland cement(OPC) and micro cement used in MIS(Micro-Injection Process System). For this research, a injection equipment was developed for pressure permeation which can evenly simulate various grouting tests in a laboratory and suggested a standard for the production of the test specimen. Using the injection device, the laboratory injection tests of grouts were prepared with water/cement ratio of 1:1, 2:1, 3:1, 4:1, and 5:1. The analysis of injection test for pressure permeation showed that the efficiency of injection increases linearly as the water/cement ratio increases. Comparison of efficiency of the injection indicates that MIS with a relatively smaller average diameter shows more efficient injection than the OPC. In the low ratio of water/cement as 2:1~1:1, the injection efficiency of OPC was especially poor. Also, a nonlinear grout volume-injection time is represented by a hyperbolic model and grout volume predicted by hyperbolic model was compared with the value measured. From the comparison, it shows that the hyperbolic model has the potential of evaluating the efficiency of grouting.

Full-Endoscopic versus Minimally Invasive Lumbar Interbody Fusion for Lumbar Degenerative Diseases : A Systematic Review and Meta-Analysis

  • Son, Seong;Yoo, Byung Rhae;Lee, Sang Gu;Kim, Woo Kyung;Jung, Jong Myung
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.4
    • /
    • pp.539-548
    • /
    • 2022
  • Objective : Although full-endoscopic lumbar interbody fusion (Endo-LIF) has been tried as the latest alternative technique to minimally invasive transforaminal lumbar interobody fusion (MIS-TLIF) since mid-2010, the evidence is still lacking. We compared the clinical outcome and safety of Endo-LIF to MIS-TLIF for lumbar degenerative disease. Methods : We systematically searched electronic databases, including PubMed, EMBASE, and Cochrane Library to find literature comparing Endo-LIF to MIS-TLIF. The results retrieved were last updated on December 11, 2020. The perioperative outcome included the operation time, blood loss, complication, and hospital stay. The clinical outcomes included Visual analog scale (VAS) of low back pain and leg pain and Oswestry disability index (ODI), and the radiological outcome included pseudoarthosis rate with 12-month minimum follow-up. Results : Four retrospective observational studies and one prospective observational study comprising 423 patients (183 Endo-LIF and 241 MIS-TLIF) were included, and the pooled data analysis revealed low heterogeneity between studies in our review. Baseline characteristics including age and sex were not different between the two groups. Operation time was significantly longer in Endo-LIF (mean difference [MD], 23.220 minutes; 95% confidence interval [CI], 10.669-35.771; p=0.001). However, Endo-LIF resulted in less perioperative blood loss (MD, -144.710 mL; 95% CI, 247.941-41.478; p=0.023). Although VAS back pain at final (MD, -0.120; p=0.586), leg pain within 2 weeks (MD, 0.005; p=0.293), VAS leg pain at final (MD, 0.099; p=0.099), ODI at final (MD, 0.141; p=0.093) were not different, VAS back pain within 2 weeks was more favorable in the Endo-LIF (MD, -1.538; 95% CI, -2.044 to -1.032; p<0.001). On the other hand, no statistically significant group difference in complication rate (relative risk [RR], 0.709; p=0.774), hospital stay (MD, -2.399; p=0.151), and pseudoarthrosis rate (RR, 1.284; p=0.736) were found. Conclusion : Relative to MIS-TLIF, immediate outcomes were favorable in Endo-LIF in terms of blood loss and immediate VAS back pain, although complication rate, mid-term clinical outcomes, and fusion rate were not different. However, the challenges for Endo-LIF include longer operation time which means a difficult learning curve and limited surgical indication which means patient selection bias. Larger-scale, well-designed study with long-term follow-up and randomized controlled trials are needed to confirm and update the results of this systematic review.

Electrical Conduction Mechanism of AIN Insulator thin Film Fabricated by Reactive Sputtering Method for the Application of MIS Device (반응성 스퍼터링으로 제조한 MIS 소자용 AIN 절연박막의 전기전도 메커니즘)

  • Park, Jung-Cheul;Kwon, Jung-Youl;Lee, Heon-Yong;Chu, Soon-Nam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.751-755
    • /
    • 2007
  • We have studied the variable conditions of reactive sputtering to prepare AM thin film. The leakage current showed below $10^{-9}A/cm^2$ at the deposition temperature of $250^{\circ}C\;and\;300^{\circ}C$ in the field of 0.1 MV/cm, and it was gradually increased and to be saturated in 0.2 MV/cm. The C-V characteristics of the above mentioned deposition temperature conditions showed a deep depletion phenomenon at inversion region. The C-V characteristics showed similarly under the DC power conditions of 100 and 150 W but were degraded at 200W. When the DC power was 100, 200, and 300 W the dielectric breakdown phenomenon was shown in 2.8, 3.2 and 5.2 MV/cm, respectively. It was found that AIN film was dominated by Poole-Frenkel conduction mechanism.

Clinical Applications of the Tubular Retractor on Spinal Disorders

  • Kim, Young-Baeg;Hyun, Seung-Jae
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.245-250
    • /
    • 2007
  • Tubular retractor system as a minimally invasive surgery (MIS) technique has many advantages over other conventional MIS techniques. It offers direct visualization of the operative field, anatomical familiarity to spine surgeons, and minimizing tissue trauma. With technical advancement, many spinal pathologies are being treated using this system. Namely, herniated discs, lumbar and cervical stenosis, synovial cysts, lumbar instability, trauma, and even some intraspinal tumors have all been treated through tubular retractor system. Flexible arm and easy change of the tube direction are particularly useful in contralateral spinal decompression from an ipsilateral approach. Careful attention to surgical technique through narrow space will ensure that complications are minimized and will provide improved outcomes. However, understanding detailed anatomies and keeping precise surgical orientation are essential for this technique. Authors present the technical feasibility and initial results of use a tubular retractor system as a minimally invasive technique for variaties of spinal disorders with a review of literature.

Investigating the Relationship between Enterprise Architecture Effort and IT Capability (아키텍팅 노력과 IT 역량 간의 관계)

  • Kim, Sung-Kun
    • Journal of Information Technology Applications and Management
    • /
    • v.17 no.4
    • /
    • pp.107-126
    • /
    • 2010
  • IT capability is one of the main research topics in MIS area. Given the finding that IT investment does not necessarily contribute to better organizational performance, the concept of IT capability was selected as an alternative antecedent variable for IT's effect on performance. A number of existing MIS papers have shown that firms with the high level of IT capability lead to a better performance. However, very little research has been done concerning the issue of how the IT capability could be enhanced. Recently, enterprise architecture effort has been emerged as an avenue to better IT management. This study aims to empirically examine the relationship between EA effort and IT capability.

  • PDF

NNO memory device's characteristics (NNO 메모리 소자의 특성)

  • Lee, Joon-Nyung;Son, Hyuk-Joo;Yi, Jun-Sin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.133-134
    • /
    • 2008
  • 이 논문에서는 $SiN_x$의 band gap 차이를 이용하여 MIS 구조의 메모리 소자를 제작하고 이를 분석하였다. $SiN_x$ 박막은 증착 가스비에 따라 다양한 band gap을 가지게 된다. 본 실험에서는 n-type 단결정 실리콘 기판위에 $SiH_4/NH_3$ 가스를 혼합하여 $SiN_x$ 박막을 증착하고, UV-Vis Spectrophotometer 장비를 이용하여 band gap을 구하였다. 큰 band gap을 갖는$SiN_x$ 박막을 블로킹 층에, 작은 band gap을 작는 $SiN_x$ 박막을 전하 저장 층에 사용하였다. 제작된 NNO 구조일 소자는 7.6 V의 hysteresis roof 폭과 1000초 후에 88.6 %의 retention 값을 갖는 우수한 메모리 특성을 보였다.

  • PDF

Effect of Characteristic of the Organic Memory Devices by the Number of CdSe/ZnS Nanoparicles Per Unit Area Changes

  • Kim, Jin-U;Lee, Tae-Ho;No, Yong-Han
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.388-388
    • /
    • 2013
  • 현대 사회에서 고집적 및 고성능의 전자소자의 필요성은 지속적으로 요구되고 있으며, 투명하거나 플렉서블한 특성의 필요성에 따라 이에 대한 기술개발이 이루어지고 있다. 특히, 이러한 특성을 만족하면서 대면적화 및 저온 공정의 특성을 지니는 유기물 반도체가 주목받고 있고, 이를 이용하여 OLED (Organic Light Emitting Diode), OTFT (Organic Thin Film Transistor)와 같은 다양한 유기물 반도체 소자가 개발되고 있다. 대표적인 예로는이 있다. 유기물 반도체 소자의 특성을 이용한 메모리 소자 또한 연구 및 개발이 지속되고 있으며, 유연성과 낮은 공정가격 등의 특성을 가지는 나노 입자들이 기존 Floating Gate의 대체물로 각광받고 있다. 본 논문에서는 MIS (Metal/Insulator/Semiconductor) 구조를 제작하고, Insulator 내부에Core/Shell 구조를 가지는 CdSe/ZnS 나노 입자를 부착하여 메모리 소자의 특성 확인 및 단위 면적당 개수에 따른 특성 변화를 확인하고자 하였다. 합성된 PVP (Poly 4-Vinyl Phenol)를 Insulator 층으로 사용하였으며 단위 면적당 나노 입자의 개수를 조절하여 제작된 MIS 소자를 Capacitance versus Voltage (C-V) 측정을 통하여 변화특성을 확인하였다.

  • PDF