• 제목/요약/키워드: MIMS

Search Result 16, Processing Time 0.021 seconds

Dissolved Methane Measurements in Seawater and Sediment Porewater Using Membrane Inlet Mass Spectrometer (MIMS) System (Membrane Inlet Mass Spectrometer (MIMS) 시스템을 이용한 해수 및 퇴적물 공극수내 용존 메탄의 측정)

  • An, Soon-Mo;Kwon, Ji-Nam;Lim, Jea-Hyun;Park, Yun-Jung;Kang, Dong-Jin
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.3
    • /
    • pp.244-250
    • /
    • 2007
  • Membrane inlet mass spectrometer (MIMS) has been used to accurately quantify dissolved gases in liquid samples. In this study, the MIMS system was applied to measure dissolved methane in seawater and sediment porewater. To evaluate the accuracy of the measurement, liquid samples saturated with different methane partial pressure were prepared and the methane concentrations were quantified with the MIMS system. The measured values correspond well with the expected values calculated from solubility constants. The standard error of the measurements were $0.13{\sim}0.9%$ of the mean values. The distribution of dissolved methane concentration in seawater of the South Sea of Korea revealed that the physical parameters primarily control the methane concentration in sea water. The MIMS system was effective to resolve the small dissolved methane difference among water masses. The probe type inlet in MIMS system was proven to be effective to measure porewater methane concentration.

MIMS: Web-based Micro Machining Service (MIMS: 웹기반 마이크로 머시닝 서비스)

  • Chu W.-S.;Ahn S.-H.;Kim D.-S.;Jun C.-S.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.9 no.3
    • /
    • pp.246-252
    • /
    • 2004
  • Presented in this Paper is a Micro Machining Service .(MIMS) based on the World Wide Web technologies. In order to ensure easy access to the service, the web browsers are used as the user interface. The pan geometry as an STL file is uploaded with process parameter for 3-axis CNC milling. Depending on the predefined user level, novice or expert, the user interface requires different parameters for process planning. An STL-based CAM resides in the server and automatically provides NC codes upon user's request. Tool-paths for scanning and pencil-cut, which are interference-free and precise, are created by the curve-based polyhedral machining method. A couple of sample parts were fabricated by a micro endmill with 127 fm diameter. From the tests, the parts fabricated by scanning followed by pencil-cut resulted in less error(within 2%) than the parts machined only by scanning tool-path.

Effects of Organizational Use of KakaoTalk, a Mobile Instant Messaging (MIM) Service, on Employees' Attitudes toward Current Organization in Korea

  • Jaehee Cho
    • Asia pacific journal of information systems
    • /
    • v.30 no.1
    • /
    • pp.120-142
    • /
    • 2020
  • Present-day organizations have become largely dependent on mobile instant messaging services (MIMs) for various organizational purposes. Focusing on the increasing use of MIMs in today's organizations, this study aims to explain how different aspects of KakaoTalk, the most dominant MIM in Korea, influence employees' attitudes toward their current employers, and how these attitudes impact the employees' intentions to stay at their present workplaces. Overall, with the exception of one factor (satisfaction with KakaoTalk use), all other factors (perceived quality of information exchanged through KakaoTalk, belongingness through KakaoTalk, and KakaoTalk overload) significantly influenced employee's attractiveness toward their current employers. Specifically, while KakaoTalk overload's effect on perceived organizational attractiveness was negative, two other factors were positively associated with it. Perceived organizational attractiveness also strongly influenced employees' intention to stay at their present workplaces. These findings contribute to expanding practical and theoretical understandings regarding the critical roles of MIMs in the efficient management of organizations in this hyperconnected society.

Preparation and Adsorption Properties of PA6/PSMA-OA Molecularly Imprinted Composite Membranes in Supercritical CO2

  • Zhang, Qing;Zhang, Xingyuan;Zhang, Wencheng;Pan, Jian;Liu, Ling;Zhang, Haitao;Zhao, Dong;Li, Zhi
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.9
    • /
    • pp.3348-3354
    • /
    • 2011
  • Oleanolic acid (OA) as template molecule, polyamide-6 (PA6) as basement membrane and poly(styrene-comaleic acid) (PSMA) were used to prepare PA6/PSMA-OA molecularly imprinted composite membranes by phase inversion method in supercritical $CO_2$ ($ScCO_2$). The template molecule (OA), [poly(styrene-co-maleic anhydride) (PSMAH), PSMA, molecularly imprinted membranes (MIMs) imprinting OA and MIMs after elution were all characterized by Fourier transform infrared spectroscopy (FTIR). The conditions that were the mass ratio between PSMA and OA from 3:1 to 8:1, temperature of $ScCO_2$ from $35^{\circ}C$ to $50^{\circ}C$ and pressure of $ScCO_2$ 12 MPa to 17 MPa were studied. It was obtained the largest adsorption rate and purity of OA after adsorption of the resultant MIMs, 50.41% and 96.15% respectively. After using PA6 film and non-woven fabrics as basement membrane respectively, it was found that smaller aperture of PA6 was used as basement membrane, a higher adsorption rate and a higher purity of OA after adsorption of the MIMs were obtained, and so were the stability and reproducibility of the resultant MIMs. After template molecules being removed, the MIMs had effective selectivity hydrogen bonding to separately bind in the binary components to the template molecules-oleanolic acid.

Dynamic smile reanimation in facial nerve palsy

  • Santha, Krishnakumar Krishnan;Joseph, Subin;Latheef, Sameer;Narayanan, Saju;Nair, Santhy Mohanachandran;Babu, Bibilash;Sivadasan, Anand;Shet, Srivatsa Manjunath;Pydi, Rajesh Vardhan;Pati, Ajit;Samantaray, Srikant Aruna
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.2
    • /
    • pp.143-149
    • /
    • 2020
  • Objectives: Long-term facial paralysis results in degeneration of the distal nerve segment and atrophy of the supplied muscles. Options for these patients include free muscle transfer, temporalis myoplasty, and botulinum toxin injections for smile reanimation. In this study we aimed to evaluate the subjective and objective outcomes of these procedures. Materials and Methods: In our study, we retrospectively analyzed smile symmetry in patients with facial palsy (n=8) who underwent facial reanimation procedures. Results: Subjective analysis showed high satisfaction in seven out of eight patients. Objective analysis showed statistically significant improvement postoperatively in both vertical and horizontal smile symmetry at rest and during maximum smile (P<0.001). Conclusion: Choosing the ideal procedure for the patients is the most critical aspect for facial reanimation. Though free muscle transfer is considered gold standard procedure, temporalis myoplasty also gives satisfactory results. Residual synkinesis which can lead to disturbing aesthetic deformity can be effectively treated with botulinum toxin.

14N Mines Pulsed-ENDOR of Proximal Histidine and Heme of Aquometmyoglobin and Fluormetmyoglobin

  • Lee, Hong-In
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.12
    • /
    • pp.1769-1772
    • /
    • 2002
  • Previous $^{19}F\;and\;^{1,2}H$ electron-nuclear double resonance (ENDOR) study of fluorometmyoglobin (MbF) in frozen-solution state provided sensitive tools sensing subtle structural changes of the heme that are not obtainable from X-ray. [Fann et al., J. Am. Chem. Soc. 1995, 117, 6019] Because of the intrinsic inhomogeneouse EPR line broadening effect of MbF in frozen-solution state, detection of the intrinsic inhomogeneouse EPR line broadening effect of MbF in frozen-solution state, detection of the electronic and geometrical changes of the heme ring itself and the proximal histidine by using $^{14}N$ CW ENDOR was interfered. In the present study, hyperfine-sensitive $^{14}N$ Mims ENDOR technique of pulsed-EPR was employed to probe the changes. With two different $\tau$ values of 128 and 196 ns, $^{14}N$ ENDOR signals of the heme and proximal histidine were completely resolved at $g'_{II}(=g_e=2)$. This study present that X-band $^{14}N$ Mims ENDOR sequence can sensitively detect the small changes of the spin densities and p orbital populations of the proximal and the heme nitrogens, caused by ligand and pH variation of the distal site.

A Sequential Indexing Method for Multidimensional Range Queries (다차원 범위 질의를 위한 순차 색인 기법)

  • Cha Guang-Ho
    • Journal of KIISE:Databases
    • /
    • v.32 no.3
    • /
    • pp.254-262
    • /
    • 2005
  • This paper presents a new sequential indexing method called segment-page indexing (SP-indexing) for multidimensional range queries. The design objectives of SP-indexing are twofold:(1) improving the range query performance of multidimensional indexing methods (MIMs) and (2) providing a compromise between optimal index clustering and the full index reorganization overhead. Although more than ten years of database research has resulted in a great variety of MIMs, most efforts have focused on data-level clustering and there has been less attempt to cluster indexes. As a result, most relevant index nodes are widely scattered on a disk and many random disk accesses are required during the search. SP-indexing avoids such scattering by storing the relevant nodes contiguously in a segment that contains a sequence of contiguous disk pages and improves performance by offering sequential access within a segment. Experimental results demonstrate that SP-indexing improves query performance up to several times compared with traditional MIMs using small disk pages with respect to total elapsed time and it reduces waste of disk bandwidth due to the use of simple large pages.

Membrane Introduction Mass Spectrometry (MIMS) for Online, Real Time Analysis of Organic Substances

  • 박현채
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1994.04a
    • /
    • pp.29-32
    • /
    • 1994
  • The increasing environmental risks exert strong demands for the knowledge of environmentally significant compounds and the reduction of such compounds on the earth. The risk reduction can, in principle, be most effectively achieved by minimizing the formation of environmental pollutants, by-products in many cases, during processes in factories, power plants and other sources. This can be done by on-line, real time monitoring the formation of pollutants at the moment when they are formed, and thereby through the feed-back control of the process.

  • PDF

Comparison of the efficacy of amoxicillin-clavulanic acid with metronidazole to azithromycin with metronidazole after surgical removal of impacted lower third molar to prevent infection

  • Sayd, Shermil;Vyloppilli, Suresh;Kumar, Krishna;Subash, Pramod;Kumar, Nithin;Raseel, Sarfras
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.44 no.3
    • /
    • pp.103-106
    • /
    • 2018
  • Objectives: The goal of the study was to investigate the clinical effects of amoxicillin-clavulanic acid (500+125 mg) with metronidazole 400 mg administered three times daily (Group I) versus azithromycin 500 mg administered once daily and with metronidazole 400 mg three times daily (Group II) for the prevention of postoperative infection following mandibular third molar surgical removal. Materials and Methods: The study design was a single-center prospective study. Patients who reported to the Department of Oral and Maxillofacial Surgery between February 2015 and January 2017 for removal of mandibular third molar were screened, and 108 patients were chosen. One surgeon carried out all procedures. Patients were prescribed antibiotics until the two groups contained a similar number of cases. Results: Our data showed that Group II had fewer incidences of surgical site infection, but with no statistical significance. Conclusion: Although both treatments are used routinely after removal of the mandibular third molar, neither is significantly better than the other.