• Title/Summary/Keyword: MFS

Search Result 167, Processing Time 0.021 seconds

Development of Fall Assessment Scale in Adult Inpatients (한국형 성인 환자 낙상위험 사정도구 개발)

  • Choi, Eun Hee;Ko, Mi Suk;Hong, Sang Hee;Kim, In Sook
    • Journal of Korean Clinical Nursing Research
    • /
    • v.25 no.2
    • /
    • pp.179-188
    • /
    • 2019
  • Purpose: The purpose of this study was to develop a valid Adult Fall Assessment Scale Korean version (FAS-K) for inpatients in general hospitals in Korea. Methods: This a 14 item FAS-K was developed based on a review of national and international research and expert opinions in related field. Interrater reliability of FAS-K was analyzed using the ICC (Intraclass Correlation Coefficients). To examine the validity of FAS-K, a CVI (Content Validity Index), the Pearson correlation coefficients between FAS-K and two widely used scales, the Morse Fall Scale (MFS) and the Johns Hopkins Hospital Fall Risk Assessment Tool (JHFRAT), and the Mann-Whitney test were used. Results: The ICC was .958. The CVI ranged from .70 to 1.00. The FAS-K was significantly associated with the MFS (r=.74, p<.001) and with the JHFRAT (r=.87, p<.001), verifying the concurrent validity of FAS-K. As for the construct validity of FAS-K, significant differences between the fall and non-fall groups were found not only in the MFS (Z=-3.23, p=.001) but also in the FAS-K (Z=-3.10, p=.002). Conclusion: The findings indicate that the FAS-K is a reliable fall risk assessment tool with high validity.

Characterization and Fermentation Characteristics of Lactic Acid Bacteria Isolated from Soybean Curd Residue (Biji) (비지에서 분리된 젖산균의 동정 및 발효특성)

  • Baek, Joseph;Lee, In-Seon;Lee, Sam-Pin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.4
    • /
    • pp.583-588
    • /
    • 2002
  • Two microorganisms isolated from soybean curd residue (biji) were identified as Enterococcus faecium (51% homology) and Lactobacillus rhamnosus (99.5% homology) by using gram positive identification (GPI) card and API 50 CHL kit, respectively. Ent. faecium grew well in micronized full-fat soyflour (MFS) milk, indicating pH 4.9, 0.38% acidity and 1.8$\times$10$^{9}$ CFU/$m\ell$ of viable cell counts after fermentation for 20 hr. L. rhamnosus LL showed pH 6.5 and 4.6$\times$10$^{8}$ CFU/$m\ell$ viable cell counts, but enhanced acid production in MFS milk mixture fortified with skim milk or by the addition of 1% of glucose and lactose. On the other hand, Ent. faecium LL did not show increased acid production in MFS/skim milk and MFS milk fortified with sugar. The MFS/skim milk fermented by L. rhmnosus LS and Ent. faecium LL showed 600 mg% and 350 mg% lactic acid, respectively.

Conceptual Design of Multi-Functional Structure using Rectangular Grid-Stiffened Structure for Satellite (위성용 사각형 격자강화 구조의 다기능 구조체 개념설계)

  • Seo, Hyun-Suk;Jang, Tae-Seong;Rhee, Ju-Hun;Kim, Won-Seock;Hyun, Bum-Seok;Lim, Jae-Hyuk;Hwang, Do-Soon;Lee, Sang-Kon;Cho, Hee-Keun;Han, Eun-Soo;Kim, Im-Soo;Sim, Eun-Sup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.6
    • /
    • pp.526-534
    • /
    • 2011
  • The MFS (Mlti-Functional Structure) concept, which integrates the electronics, thermal control and structure into a single packaging system, has been developed and applied to reduce the volume and weight of the satellite. Therefore, this MFS can eliminate the bulky chassis/frames, cables and connectors of the electronic equipment. The main point of this traditional MFS is the replacement of the electrical chassis/frames with MCMs (Multi-Chip Modules) that require much costs and efforts for developing. This paper shows the new MFS concept that effectively saves the volume and weight. The structure including the thermal control and radiation shielding elements will be designed and manufactured as the rectangular grid-stiffened structure. The rectangular grid-stiffened structure is the modification of the iso-grid structure, and provides the enough spaces for putting the general PCBs without the chassis/frames.

The Relationship of VDT Work Condition and Fatigue Severity in the Financial Office Workers (일부 금융직 근로자의 VDT 작업 실태와 피로도와의 관련성)

  • Choi, Soon-Young;Lee, Byung-Su
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.2
    • /
    • pp.15-24
    • /
    • 2008
  • This study was to investigate the relationship of VDT(visual display terminal) work condition and fatigue severity in the financial office workers. Questionnaires were completed by 662 persons in VDT workers of Post Office from January to May 2006. Multidimensional Fatigue Scale(MFS) that was developed in Korea Occupational Safety &Health Agency to estimate the degree of fatigue was used for study. In results, 149 persons(22.5%) in VDT workers were felt low fatigue severity, 351 workers(53.0%) were middle, and 162 workers (24.5%) were high. So it was appeared that one in four VDT workers felt the high fatigue severity. And woman VDT workers felt more fatigue severity than man. Also, fatigue severity was increased with increasing work time. Our findings suggest that VDT workers in financial office need proper health program to prevent occupational fatigue and disease.

Preparation and Properties of in situ Polymerized Poly(ethylene terephthalate)/Fumed Silica Nanocomposites

  • Hahm, Wan-Gyu;Myung, Hee-Soo;Im, Seung-Soon
    • Macromolecular Research
    • /
    • v.12 no.1
    • /
    • pp.85-93
    • /
    • 2004
  • We have prepared poly(ethylene terephthalate) (PET) nanocomposites filled with two different types of fumed silicas, hydrophilic (FS) and hydrophobic (MFS) silicas of 7-nm diameter, by in situ polymerization. We then investigated the morphological changes, rheological properties, crystallization behavior, and mechanical properties of the PET nanocomposites. Transmission electron microscopy (TEM) images indicate that the dispersibility of the fumed silica was improved effectively by in situ polymerization; in particular, MFS had better dispersibility than FS on the non-polar PET polymer. The crystallization behavior of the nanocomposites revealed a peculiar tendency: all the fillers acted as retarding agents for the crystallization of the PET nanocomposites. The incorporation of fumed silicas increased the intrinsic viscosities (IV) of the PET matrix, and the strong particleparticle interactions of the filler led to an increased melt viscosity. Additionally, the mechanical properties, toughness, and modules of the nano-composites all increased, even at low filler content.

Properties of MFS capacitors using $YMnO_3$ film ($YMnO_3$를 이용한 MFS 커패시터의 특성)

  • 김채규;김진규;정순원;김용성;이남열;김광호;유병곤;이원재;유인규
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.425-428
    • /
    • 1999
  • In this paper, the electrical properties of Pt/YMnO$_3$/Si(100) structures with difference rapid thermal annealing (RTA) treatment were investigated. YMnO$_3$films were obtained without buffer layers, introducing oxygen. A typical value of the dielectric constant was about 20 derived from 1MHz capacitance-voltage (C-V) measurement and the resistivity of the film at the field of 150kV/cm was about 1.34$\times$10$^{12}$ $\Omega$ . cm. The minimum interface state density around midgap was estimated to be about 5$\times$10$^{11}$ cm$^2$. eV.

  • PDF

Electrical Properties of Metal-Ferroelectric-Semiconductor Structures Based on Ferroelectric P(VDF-TrFE) Copolymer Film

  • Lee, Gwang-Geun;Park, Hyeong-Jin;Han, Hui-Seong;Park, Byung-Eun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.85-86
    • /
    • 2007
  • A poly(vinylidene fluoride-trifluoroethyene) (P(VDF-TrFE)) copolymer thin film having ${\beta}$ phase was prepared by sol-gel method. The electrical properties of the film were studied to evaluate the possibility for appling to a ferroelectric random access memory. In order to characterize its electrical properties, we produced a MFS (metal-ferroelectric-semiconductor) structure by evaporation of Au electrodes. The C-V (capacitance-voltage) measurement revealed that the Au/P(VDF-TrFE)/Si structure with a 4 wt% film had a memory window width of about 0.5V for a bias voltage sweep of 1V.

  • PDF

Acute unilateral isolated abducens nerve palsy associated with anti-GM1 immunoglobulin M antibody

  • Son, Hyoshin;Kim, Ahwon;Hong, Sang Bin;Koo, Dae Lim
    • Annals of Clinical Neurophysiology
    • /
    • v.21 no.2
    • /
    • pp.105-107
    • /
    • 2019
  • Acute ophthalmoparesis that includes the oculomotor, trochlear, or abducens nerve may occur as an initial presentation of Miller Fisher syndrome (MFS). The symptoms of MFS or variant forms of Guillain-Barre syndrome are pathogenically related to anti-GQ1b antibodies. We report a case of a 36-year-old man with unilateral isolated abducens nerve palsy associated with anti-GM1 antibody. To the best of our knowledge, this is the first report of unilateral isolated abducens nerve palsy with positivity for anti-GM1 immunoglobulin M antibody.

Structural Safety in Installation System for Monopile Basic Construction of Offshore Wind Power Generators (해상풍력발전기 모노파일 기초공사용 설치시스템 구조 안전성)

  • Cha, Tae-Hyeong;Chung, Won-Jee;Lee, Hyun-Jun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.2
    • /
    • pp.31-38
    • /
    • 2022
  • Recently, the development of offshore wind farms based on past technical experiences from onshore wind turbine installations has become a worldwide issue. This study investigated the technical issues related to offshore wind farms and large-diameter monopiles from an economic perspective. In particular, the monopile foundation system (MFS), which is the most important part of the proposed fast construction system, is applied for the first time in Korea, and structural verification is essential because it supports large-diameter monopiles and is in charge of excavation. Therefore, in this study, a rapid construction system for large offshore wind power generators was introduced, and stability verification was performed through the structural analysis of the MFS.

Preliminary Analysis on the Effects of Tropospheric Delay Models on Geosynchronous and Inclined Geosynchronous Orbit Satellites

  • Lee, Jinah;Park, Chandeok;Joo, Jung-Min
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.10 no.4
    • /
    • pp.371-377
    • /
    • 2021
  • This research proposes the best combination of tropospheric delay models for Korean Positioning System (KPS). The overall results are based on real observation data of Japanese Quasi-Zenith satellite system (QZSS), whose constellation is similar to the proposed constellation of KPS. The tropospheric delay models are constructed as the combinations of three types of zenith path delay (ZPD) models and four types of mapping functions (MFs). Two sets of International GNSS Service (IGS) stations with the same receiver are considered. Comparison of observation residuals reveals that the ZPD models are more influential to the measurement model rather than MFs, and that the best tropospheric delay model is the combination of GPT3 with 5 degrees grid and Vienna Mapping Function 1 (VMF1). While the bias of observation residual depends on the receivers, it still remains to be further analyzed.