• Title/Summary/Keyword: MFCS

Search Result 74, Processing Time 0.026 seconds

The Overall Performance Improvement of Microbial Fuel Cells Connected in Series with Dairy Wastewater Treatment

  • Choudhury, Payel;Bhunia, Biswanath;Bandyopadhyay, Tarun Kanti;Ray, Rup Narayan
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.101-111
    • /
    • 2021
  • To improve the potential of single chamber microbial fuel cells (SCMFCs) as an applicable technology, the main challenge is a practical application for larger scales bioenergy production from potent exoelectrogenic microorganism with real dairy wastewater. To increase power generation, three individual MFCs were together operated in series best under the fed batch condition for 15 days. The volume of MFC 1 and MFC 2 is "300 mL" and MFC 3 is "500 mL" respectively. The individual MFCs 1, MFC 2 and MFC 3 gives an open circuit voltage of 0.60 V, 0.66 V and 0.55 V and result in total working voltage when connected in series of 1.745V, which lead an LED to glow. The maximum power densities obtained from MFC 1, MFC 2 and MFC 3 are 62 mW/㎡, 50 mW/㎡ and 45 mW/㎡ (normalized to the surface area of the anodic electrode, which was 50 ㎠ for all three MFCs), and corresponding to current densities of 141 mA/㎡, 155 mA/㎡ and 123 mA/㎡, respectively. Therefore this work suggests the cheapest way to connect microbial fuel cells in series to gain power with the lowest operating cost and chemical oxygen demand (COD) removal.

An Analysis on the Efficiency and Productivity for Major Mutual Financing Cooperatives in Korea (우리나라 상호금융조합의 효율성 및 생산성 분석)

  • Bae, Se-Young;Kim, Hee-Chang
    • Journal of Digital Convergence
    • /
    • v.18 no.2
    • /
    • pp.235-247
    • /
    • 2020
  • The Mutual Financial Cooperatives(MFCs) in Korea need to make efforts to increase efficiency and productivity in order to secure stable and sustainable growth and competitiveness. Therefore, this study analyzes the efficiency and productivity of MFCs from 2012 to 2018 and suggests some implications. The methodology employed is a Dynamic-Network Slacks-Based Measure(DNSBM) Model. The findings from an empirical study include that first, on average efficiency scores of the institutions, NH(0.225) showed the highest overall efficiency, and followed by SH(0.128) and MG(0.126). After 2015, most of the MFCs' efficiency scores had risen until to 2018. Second, in divisional analysis, the inefficiency in creating the high profitability-stage had been greater than establishing-funds-stage. Third, in projection analysis of Division 2, the inefficiency of the output factors such as interest income and operating income was severe. Fourth, the results from the Malmquist Productivity Index analysis of Division 1 of the fist-stage illustrate that all three MFCs showed minus catch-up effects. Also, a soundness from reducing bad loans and expansion of loans in combination with generating various ways of creating profits besides the interest income is urgently needed for Korean MFCs.

Characterization of Polyester Cloth as an Alternative Separator to Nafion Membrane in Microbial Fuel Cells for Bioelectricity Generation Using Swine Wastewater

  • Kim, Taeyoung;Kang, Sukwon;Sung, Je Hoon;Kang, Youn Koo;Kim, Young Hwa;Jang, Jae Kyung
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.12
    • /
    • pp.2171-2178
    • /
    • 2016
  • Polyester cloth (PC) was selected as a prospective inexpensive substitute separator material for microbial fuel cells (MFCs). PC was compared with a traditional Nafion proton exchange membrane (PEM) as an MFC separator by analyzing its physical and electrochemical properties. A single layer of PC showed higher mass transfer (e.g., for $O_2/H^+/ions$) than the Nafion PEM; in the case of oxygen mass transfer coefficient ($k_o$), a rate of $50.0{\times}10^{-5} cm{\cdot}s^{-1}$ was observed compared with a rate of $20.8{\times}10^{-5}cm/s$ in the Nafion PEM. Increased numbers of PC layers were found to reduce the oxygen mass transfer coefficient. In addition, the diffusion coefficient of oxygen ($D_O$) for PC ($2.0-3.3{\times}10^{-6}cm^2/s$) was lower than that of the Nafion PEM ($3.8{\times}10^{-6}cm^2/s$). The PC was found to have a low ohmic resistance ($0.29-0.38{\Omega}$) in the MFC, which was similar to that of Nafion PEM ($0.31{\Omega}$); this resulted in comparable maximum power density and maximum current density in MFCs with PC and those with Nafion PEMs. Moreover, a higher average current generation was observed in MFCs with PC ($104.3{\pm}15.3A/m^3$) compared with MFCs with Nafion PEM ($100.4{\pm}17.7A/m^3$), as well as showing insignificant degradation of the PC surface, during 177 days of use in swine wastewater. These results suggest that PC separators could serve as a low-cost alternative to Nafion PEMs for construction of cost-effective MFCs.

A Model of a Mechanical Flight-Control System for Simulating Control Authority Switching of a Helicopter Technical Demonstrator (헬리콥터 기술시범기의 비행제어 조종권 전환 모의를 위한 기계식 조종장치 모델 설계 연구)

  • Yang, Chang Deok
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.2
    • /
    • pp.23-29
    • /
    • 2017
  • Since the flight-control system is critical for the safety of an aircraft, a fail-safe system is needed in a flight demonstrator used to test a new flight-control system. A backup control system is also needed to ensure safety in using a mechanical flight-control system. This paper presents a development of an MFCS (Mechanical Flight Control System) model for simulating control authority switching of a helicopter technical demonstrator, as well as the results of evaluating the developed MFCS model.

Modulated Finite Control Set - Model Predictive Control for Harmonic Reduction in a Grid-connected Inverter

  • Nguyen, Tien Hai;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.268-269
    • /
    • 2017
  • This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. Distorted grid condition is undesirable due to negative effects such as power losses and heating problem in electrical equipments. To enhance the power quality of distributed generation systems under such a condition, a modulated finite control set - model predictive control (MFCS-MPC) scheme will be proposed, in which the optimal switching signals of inverter are chosen by online basis using the principle of current error minimization. In addition, the moving average filter (MAF) is used to improve the phase-lock loop in order to obtain the harmonic-free reference currents on the stationary frame. The usefulness of the proposed MFCS-MPC method is proved by the comparative simulation results under different operating conditions.

  • PDF

Microwave-treated Expandable Graphite Granule for Enhancing the Bioelectricity Generation of Microbial Fuel Cells

  • Kim, Minsoo;Song, Young Eun;Li, Shuwei;Kim, Jung Rae
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.297-301
    • /
    • 2021
  • Microbial fuel cells (MFCs) convert chemical energy to electrical energy via electrochemically active microorganisms. The interactions between microbes and the surface of a carbon electrode play a vital role in capturing the respiratory electrons from bacteria. Therefore, improvements in the electrochemical and physicochemical properties of carbon materials are essential for increasing performance. In this study, a microwave and sulfuric acid treatment was used to modify the surface structure of graphite granules. The prepared expandable graphite granules (EGG) exhibited a 1.5 times higher power density than the unmodified graphite granules (1400 vs. 900 mW/m3). Scanning electron microscopy and Fourier transform infrared spectroscopy revealed improved physical and chemical characteristics of the EGG surface. These results suggest that physical and chemical surface modification using sulfuric acid and microwave heating improves the performance of electrode-based bioprocesses, such as MFCs.

Continuous electricity generation in microbial fuel cells with non-precious metal catalysts (비귀금속촉매 미생물연료전지의 연속운전을 통한 전기 생산)

  • Moon, Chungman;Kim, Dong-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.1
    • /
    • pp.45-51
    • /
    • 2015
  • In this study, continuous microbial fuel cells (MFCs) were operated using non-precious metal catalysts such as iron(II) phthalocyanine (FePc) and cobalt tetramethoxyphenylporphyrin (CoTMPP)) as alternative cathode catalysts for platinum. To evaluate MFCs performance, operational conditions of organic loading rate (OLR) (0.5~3 g COD/L/d) and hydraulic retention rate (HRT) (0.25~1 day) were changed. Power density of MFCs were determined by cathode electrode performance. The maximum power density was $3.3W/m^3$ with platinum at OLR 3 g COD/L/d. Given each HRTs at 1 g COD/L/d, FePc showed to be a better alternative for platinum than CoTMPP because the power density of MFC with FePc was similar to that of MFC with platinum. CoTMPP catalyst, however, showed the lowest power density due to increase of internal resistance during continuous operation.

Genomic Barcode-Based Analysis of Exoelectrogens in Wastewater Biofilms Grown on Anode Surfaces

  • Dolch, Kerstin;Wuske, Jessica;Gescher, Johannes
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.3
    • /
    • pp.511-520
    • /
    • 2016
  • The most energy-demanding step of wastewater treatment is the aeration-dependent elimination of organic carbon. Microbial fuel cells (MFCs) offer an alternative strategy in which carbon elimination is conducted by anaerobic microorganisms that transport respiratory electrons originating from carbon oxidation to an anode. Hence, chemical energy is directly transformed into electrical energy. In this study, the use and stability of barcode-containing exoelectrogenic model biofilms under non-axenic wastewater treatment conditions are described. Genomic barcodes were integrated in Shewanella oneidensis, Geobacter sulfurreducens, and G. metallireducens. These barcodes are unique for each strain and allow distinction between those cells and naturally occurring wild types as well as quantification of the amount of cells in a biofilm via multiplex qPCR. MFCs were pre-incubated with these three strains, and after 6 days the anodes were transferred into MFCs containing synthetic wastewater with 1% wastewater sludge. Over time, the system stabilized and the coulomb efficiency was constant. Overall, the initial synthetic biofilm community represented half of the anodic population at the end of the experimental timeline. The part of the community that contained a barcode was dominated by G. sulfurreducens cells (61.5%), while S. oneidensis and G. metallireducens cells comprised 10.5% and 17.9%, respectively. To the best of our knowledge, this is the first study to describe the stability of a synthetic exoelectrogenic consortium under non-axenic conditions. The observed stability offers new possibilities for the application of synthetic biofilms and synthetically engineered organisms fed with non-sterile waste streams.

Two-stage Bioprocesses Combining Dark H2 Fermentation: Organic Waste Treatment and Bioenergy Production (혐기성 수소발효를 결합한 생물학적 2단공정의 유기성폐자원 처리 및 바이오에너지 생산)

  • LEE, CHAE-YOUNG;YOO, KYU-SEON;HAN, SUN-KEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.3
    • /
    • pp.247-259
    • /
    • 2015
  • This study was performed to investigate the application of dark $H_2$ fermentation to two-stage bioprocesses for organic waste treatment and energy production. We reviewed information about the two-stage bioprocesses combining dark $H_2$ fermentation with $CH_4$ fermentation, photo $H_2$ fermentation, microbial fuel cells (MFCs), or microbial electrolysis cells (MECs) by using academic information databases and university libraries. Dark fermentative bacteria use organic waste as the sole source of electrons and energy, converting it into $H_2$. The reactions related to dark $H_2$ fermentation are rapid and do not require sunlight, making them useful for treating organic waste. However, the degradation is not complete and organic acids remain. Thus, dark $H_2$ fermentation should be combined with a post-treatment process, such as $CH_4$ fermentation, photo $H_2$ fermentation, MFCs, or MECs. So far, dark $H_2$ fermentation followed by $CH_4$ fermentation is a promising two-stage bioprocess among them. However, if the problems of manufacturing expenses, operational cost, scale-up, and practical applications will be solved, the two-stage bioprocesses combining dark $H_2$ fermentation with photo $H_2$ fermentation, MFCs, or MECs have also infinite potential in organic waste treatment and energy production. This paper demonstrated the feasibility of two-stage bioprocesses combining dark $H_2$ fermentation as a novel system for organic waste treatment and energy production.

Optimal Metal Dose of Alternative Cathode Catalyst Considering Organic Substances in Single Chamber Microbial Fuel Cells

  • Nam, Joo-Youn;Moon, Chungman;Jeong, Emma;Lee, Won-Tae;Shin, Hang-Sik;Kim, Hyun-Woo
    • Environmental Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.145-150
    • /
    • 2013
  • Optimal preparation guidelines of a cathode catalyst layer by non-precious metal catalysts were evaluated based on electrochemical performance in single-chamber microbial fuel cells (MFCs). Experiments for catalyst loading rate revealed that iron(II) phthalocyanine (FePc) can be a promising alternative, comparable to platinum (Pt) and cobalt tetramethoxyphenylporphyrin (CoTMPP), including effects of substrate concentration. Results showed that using an optimal FePc loading of $1mg/cm^2$ was equivalent to a Pt loading of $0.35mg/cm^2$ on the basis of maximum power density. Given higher loading rates or substrate concentrations, FePc proved to be a better alternative for Pt than CoTMPP. Under the optimal loading rate, it was further revealed that 40 wt% of FePc to carbon support allowed for the best power generation. These results suggest that proper control of the non-precious metal catalyst layer and substrate concentration are highly interrelated, and reveal how those combinations promote the economic power generation of single-chamber MFCs.