• Title/Summary/Keyword: MF(Median Frequency)

Search Result 27, Processing Time 0.018 seconds

The Analysis of the Muscle Fatigue for the Lower Limbs Muscle during the Level and Downhill Running (평지와 내리막 달리기 시 하지 근육의 근 피로에 관한 연구)

  • Moon, Gon-Sung;Lee, Eui-Lin
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.181-190
    • /
    • 2007
  • The purpose of this study was to analyze the muscle fatigue for lower limbs during the level and downhill running. The subjects were 6 males of twenties who have no experience to get the injury in the lower limbs and required to run on the level and downhill which was -7% grade treadmill at 8.3km/h. EMG signal was gained by ME3000P8 Measurement Unit and computed the Median Frequency(MF) with the power spectrum analysis in the Megawin software. Rectus femoris(RF), Vastus lateralis(VL), Gluteus medius(GLU), Biceps Femoris(BF), gastrocnemius medial head(GM), gastrocnemius lateral head(GL), Tibialis anterior(TA) were selected. The result of this study were as follows: The MF of RF decreased in the downhill running than level running in length of time but, the MF of VL was opposite. The MF of BF decreased in the level and downhill running, but, the MF of BF decreased much in the level than downhill running. The MF of GLU decreased much in the downhill running but, almost no change in the level running. The MF of TA decreased in the level running than downhill running. The MF of GL decreased in the level running but, the MF of GM decreased in the downhill running in length of time. This study analyzed the muscle fatigue of the lower limbs with the median frequency on the basis of an assumption that the impact force for the flexion and extension of the joint and the body mass may be much in the eccentric contraction such as the downhill running than level running. RF and GM showed the muscle fatigue in the downhill running than level running. BF and GL showed the muscle fatigue in the level running than downhill running.

Implementation of EEG Artifact Removal Process Based on Bispectrum Analysis (바이스펙트럼 분석 기반의 뇌파 Artifact 제거 프로세스 구현)

  • Park, Junmo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.2
    • /
    • pp.63-69
    • /
    • 2019
  • In this study, bispectrum analysis method introduced to reduce variability of SEF(spectral edge frequency) and MF(median frequency), which are the anesthetic depth indexes extracted by EEG spectral analysis. Bispectrum analysis is an analytical method that can confirm the nonlinearity of EEG. Signal measurement and analysis in the surgical environment should take into consideration various external artifact factors. Bispectrum analysis can confirm the presence of externally introduced artifacts, thereby effectively eliminating artifacts that affect the EEG signal. By applying bispectrum parameters, real-time variability of the anesthetic depth parameters SEF, MF could be reduced. Elimination of variability makes it possible to use SEF, MF as a real-time index during surgery.

Effect of Neck Position on Muscle Fatigue during Shaker Exercise

  • Park, Eun-Jung;Koo, Jung-Wan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.6
    • /
    • pp.541-547
    • /
    • 2013
  • Objective: The aim of this study is to find the influence on muscle fatigue by changing an angle of neck while Shaker exercise. Background: Shaker exercise is commonly applied to dysphagia patients for strengthen suprahyoid muscle(SHM) and relaxing upper esophageal sphincter. Method: Experiments were conducted by measuring muscle fatigue with surface electromyography(SEMG) in case of neck $15^{\circ}$ and $50^{\circ}$ flexion, in addition to original method. For the study 30 undergraduate students were participated as subjects. Muscle fatigue was measured with variations of median frequency(MF) and median frequency slope(MFS) by attaching SEMG to 3 muscles. At the same time, perceived exertion was measured by using Borg's rating of perceived exertion(RPE). Results: A MF was increased when low angle in SHM, both male and female. It means that muscle fatigue was significantly decreased(p<.05). RPE was significantly increased when low angle(p<.01). Perceived exertion explained 15.2% of the variation of MF in SHM. And regression equation was, MF in SHM = 59.918 + (4,910 * RPE). Conclusion: The outcome shows that it is possible to use the efficient method which makes muscle fatigue decrease by reducing the angle of neck flexion. Application: The results might contribute to develop the effective Shaker exercise method.

The Study on effect of the Muscle Activities for Dietshoes (Backless) (다이어트신발(Barkless)이 근육 활성도에 미치는 영향에 관한 연구)

  • Lee, Chang-Min;Oh, Yeon-Ju;Lee, Kyung-Deuk;Park, Seung-Bum;Lee, Hoon-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.117-124
    • /
    • 2006
  • The modern convenient life formed by industrial development becomes lack of exercise and takes an interest in diet. Specially, professional walking shoes is developed as people take an interest in jogging, Those shoes, professional walking shoes or Dietshoes, increase exercise effects by change of heel types. Therefore, this study investigated motility effects by EMG experiment in order to measure Muscle Activities (MA) while wearing diet shoes (backless). Experiment was conducted by EMG measurement, from calf (gastrocnemius muscle), thigh (vastus muscle) and waist (erector spinae muscle), of 12 high school students. Exercise effects between the two shoes were analyzed by EMG (MF; Median Frequency, MPF; Mean Power Frequency, ZCR; Zero Crossing Rate). Results showed that the Dietshoes(MF: 48.21Hz, MPF: 65.0Hz, ZCR: 100.6Hz) had larger EMG value than that of Normal shoes(MF: 40.47Hz, MPF: 58.04Hz, ZCR: 82.09Hz). Also, in MA, the highest activities are showed in the calf, the second one is in waist, and last one is in thigh during gate. ANOVA between shoes in measurement parts showed significant effects in MF (gastrocnemius: p-value=.022, vastus laterals: p-value=.037, erector spinae: p-value=.082), MPF (gastrocnemius: p-value=.032, vastus laterals: p-value=.046, erector spinae: p-value=.090), and ZCR (gastrocnemius: p-value=.000, vastus laterals: p-value=.004, erector spinae: p-value=.134). And MA of Dietshoes is higher than that of Normal shoes, and decreasing rate of MA in Dietshoes is less than that of Normal shoes. Thus, this study validates exercise effects of Dietshoes.

Quantification of Degree of Fatigue in Back Muscle and Its Influence on Back Injury Using Electromyography Measurement (근전도를 통한 척추 근육의 피로도의 정량화 및 척추손상에 미치는 영향 연구)

  • 한정수;곽현석
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.219-224
    • /
    • 2000
  • 본 연구는 몸통의 반복적인 flexion/extension 동작 수행시 근전도신호를 측정하고 이들 신호에서 나타난 EMG parameters(median frequency, median power, RMS) 와 피실험자의 주관적 불편도의 변화양상간의 정량적인 관계를 알아보고자 수행되었다. 피실험자별로 3-5회 정해진 업무를 수행하였고 주관적불편도와 근전도 신호를 측정하였다. 실험결과 반복횟수가 증가할수록 주관적 불편도는 증가하였으며 각 task 별로 EMG parameter와 불편도의 증감율 간의 회귀분석과 상관분석을 수행한 결과 실험과 EMG parameter에 따른 변이는 존재했지만 대체로 RMS에 비해 MF와 MP의 증감율이 불편도 증감율과 상관관계가 높은 것으로 나타났다.

  • PDF

Distance Weighted Filter based on Standard Deviation Distribution for AWGN Removal (AWGN 제거를 위한 표준편차 기반의 거리가중치 필터)

  • Park, Hwa-Jung;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.118-120
    • /
    • 2021
  • In modern society, with the development of IoT technology, various digital equipment is being distributed in a wide range of fields such as CCTV and exploration robots. Accordingly, the importance of data processing is increasing, and various studies are being conducted to remove noise generated in the process of receiving data in the imaging field. Representative noise includes additive white Gaussian noise (AWGN), and existing filters for removing noise include an average filter (AF), an alpha trimmed average filter (A-TAF), and a median filter (MF). However, existing filters have a disadvantage in that they show somewhat insufficient performance in noise removal characteristics in high frequency areas. Therefore, in this paper, in order to effectively remove AWGN existing in the high frequency region, a weight filter according to a distance based on the standard deviation is proposed.

  • PDF

A study on upper extremity muscle fatigue changes of train driver (기관사 상지 근육의 피로도 변화에 대한 연구)

  • Jang, Hye-Yoen;Lee, Yung-Gi;Jang, Jae-Ho;Kim, Tae-Sik;Hong, Sung-Jun;Han, Chang-Soo;Han, Jung-Soo;Ahn, Jae-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.576-581
    • /
    • 2007
  • The purpose of this study is to investigate changes in the forearm-muscle fatigue of a train driver operating the MasCon by using EMG (electromyogram) measurement technique. Train drivers usually use their forearm 4hours/day for normal operation. Accordingly, few different EMG signals of deltoid, biceps brachii, brachioradialis, flexor carpi ulnaris muscle of upper extremity have been measured and analyzed. The raw EMG Signals have been converted into median frequency using spectrum analysis. As the result, 80% of 10 subjects (real train drivers) showed that median frequency value of all four muscles has been reduced after 30 minutes of train operation. This results demonstrated that operating MasCon for 30 minutes could induce muscle fatigue.

Body Composition Factor Comparisons of the Intracellular Fluid(ICW), Extracellular Fluid(ECW) and Cell Membrane at Acupuncture Points and Non-Acupuncture Points by Inducing Multiple Ionic Changes (생체이온 변화 유발 후 경혈과 비경혈에서의 생체 구조 성분 분석 및 비교를 통한 경혈 특이성 고찰)

  • Kim, Soo-Byeong;Chung, Kyung-Yul;Jeon, Mi-Seon;Shin, Tae-Min;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.31 no.2
    • /
    • pp.66-78
    • /
    • 2014
  • Objectives : The specificity of acupuncture point has been a highly controversial subject. Existing researches said that ion-distribution differences are observed on the acupuncture point. This study was conducted under the assumption that multiple ionic changes induced by muscle fatigue would be different between the acupuncture point with non-acupuncture point. Methods : To induce the identical fatigue, twenty subjects performed the knee extension/flexion exercise using the Biodex System 3. ST32 and ST33 as well as adjacent non-acupuncture points were selected. We measured blood lactate and analyzed the median frequency(MF) and peak torque. To obtain the information on the extracellular fluid(ECW), intracellular fluid(ICW) and cell membrane indirectly, we used the multi-frequency bioelectrical impedance analysis(MF-BIA) method. Results : MF, peak torque and blood lactate level of all measurement sites were gradually returned to normal. Re resistance of ST32 had a stronger response, but a non-acupuncture point adjacent to ST33 had a larger response up to 20 minutes post exercise. Ri resistances were similar for both acupoints and non-acupoints. The $C_m$ capacitance of ST32 had a stronger response after inducing fatigue, but ST33 had a smaller response than a non-acupuncture point adjacent to it. Conclusions : In comparison with before and after inducing fatigue, the specificity of acupuncture points was not clearly observed. Hence, we concluded that the body composition factors extraction method had the limitation as a method of finding the specificity of acupuncture points by inducing fatigue.

Implementation and Evaluation of the LUTS Diagnosis System Using FPGA (FPGA를 이용한 LUTS 진단 시스템 구현 및 평가)

  • Jeong, Do-Un;Chung, Wan-Young;Jeon, Gye-Rock
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.1
    • /
    • pp.6-14
    • /
    • 2007
  • The purpose of urodynamic investigation is to determine information on the function of the urinary system. One of the most frequently used measurement procedures in urodynamics is filling and voiding cystometry using invasive method. But in this method transurethral catheter is use and it makes patients uncomfortable. The aim of this study was to implement the system that could evaluate the function of urinary tract with noninvasive and comfortable method. Therefor in this study, a sensor and measuring system were implemented to measure uroflow, urophonography and noninvasive bladder pressure signal during urination for diagnosing the LUTS(lower urinary tract symptoms) using noninvasive method. The implemented system compose of the sensor parts, signal conditioning parts, system control parts using FPGA and PC monitoring program. For the evaluation of the implemented system, the simulation of system's control part was performed and the model system for the lower urinary system was designed. From the evaluation of the model system, the mean error rate of the uroflow measurement part was 1.08% and coefficient of variation was 1,48. And the mean error rate of the noninvasive bladder pressure measurement part was 2.41% and coefficient of variation was 2.81. urophongraphy signal analysis was accomplished in a time domain and frequency domain. Average RMS power was used in a time domain analysis, and MF was used in a frequency domain analysis. From the evaluation of the model system average RMS power and MF was dependent on the occlusion degree significantly and median frequency range of $60{\sim}160Hz$ was correlated with the occlusion.

  • PDF

A Prediction of Coronary Perfusion Pressure Using the Extracted Parameter From Ventricular Fibrillation ECG Wave (심실세동 심전도 파형 추출 파라미터를 이용한 관상동맥 관류압 예측)

  • Jang Seung-Jin;Hwang Sung-Oh;Yoon Young-Ro;Lee Hyun-Sook
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.4
    • /
    • pp.274-283
    • /
    • 2005
  • Coronary Perfusion Pressure(CPP) is known for the most important parameter related to the Return of Spontaneous Circulation (ROSC), however, clinically measuring CPP is difficult either invasive or non-invaisive method. En this paper, we analyze the correlation between the extracted parameter from VF ECG wave and the CPP with the statistical method, and predict CPP value using the extracted parameters within significance level. the extracted parameters are median frequency(MF), peak frequency(PF), average segment amplitude(ASA), MSA(maximum segment amplitude), Two parameters, MF, and ASA are selected in order to predict CPP value with general regression neural network, and then we evaluated the agreement statistics between the simulated CPP and the measured CPP. In conclusion, the mean and variance of the difference between the simulated CPP and the measured CPP are 8.9716±1.3526 mmHg, and standard deviation 6.4815 mmHg with one hundred-times training and test results. the simulated CPP and the measured CPP are agreed with the overall accuracy $90.68\%$ and kappa coefficient $81.14\%$ as a discriminant parameter of ROSC.