• 제목/요약/키워드: MEPS

검색결과 48건 처리시간 0.025초

치과용 금-은-팔라디움 합금에 대한 프라이머 처리가 금속-레진 접착에 미치는 영향 (EFFECT OF METAL PRIMER TREATMENT OF THE Au-Ag-PD ALLOY SURFACE ON THE METAL-RESIN BONDING)

  • 이강;이청희;조광헌
    • 대한치과보철학회지
    • /
    • 제39권4호
    • /
    • pp.417-432
    • /
    • 2001
  • The pcf metal primers on the bond strength and durability of 4-META/MMA-TBB resins adhered to an Au-Ag-Pd alloy. For this study, the specimens were divided into 8 groups as follows: Thermocyle 0 : (1) control group : sandblast, (2) Group I : sandblast + Cesead Opaque Primer; (3) Group II : sandblast + Metal Primer; (4) Group III : sandblast + V-Primer; Thermocyle 10,000 (5) control sandblast: (6) Group I : sandblast + Cesead Opaque Primer: (7) Group II : sandblast + Metal Primer; (8) Group III sandblast + V-Primer. The shear bond strength was determined using an Instron were observed with the use of scanning electron microscope. Finally, the strengths of bonded joints were evaluated with regard to their adherence energy using a wedge test. The results obtained were as follows ; (1) The shear bond strength of 4-META/MMA-TBB resin to the Au-Ag-Pd alloy was significantly improved in all the groups treated with the primers (p<0.05). (2) Regardless of the adhesive primers used, a significant difference was observed in the bond strength of the thermocycle 0 groups and 10,000 groups (p<0.05). (3) Both before and after thermocycling, the strongest bond strength between the resin an the alloy was obtained after treatment with a metal primer containing MEPS (p<0.05). (4) In the wedge test, the adherence energies of the control group and Group III decreased more rapidly than those of Group I and II during the 2nd day of storage in water.

  • PDF

장 노년층에서의 운동 연상 및 관찰에 따른 피질척수로 변화에 대한 근신경 역학적 연구 (A Neuromuscular Biomechanic Study of the Modulation of Corticospinal Excitability by Observation and/or Imagery of Action in Older Adults)

  • 최은희
    • 한국운동역학회지
    • /
    • 제19권4호
    • /
    • pp.681-688
    • /
    • 2009
  • 본 연구는 22명의 오른손 잡이로 신경학적 이상이 없는 장노년층을 대상으로 경두개 자기자극 후 우측 단무지 외전근에서 운동 유발 전위를 측정함으로써 빠르고 느린 동작에 대한 수동적 혹은 능동적 운동 관찰과 연상을 시행할 때 피질척수로의 흥분도에 있어 변화가 일어나는지 알아보고자 시행되었다. 대상자에게 빠르고 느린 무지의 외전 운동을 수동적으로 관찰하거나(수동관찰), 연상하거나(운동 연상), 능동적으로 따라하려는 마음으로 관찰하도록한 상태(능동 관찰)에서 각각 운동 유발 전위의 진폭과 잠시를 측정하였고 안정 시에 측정된 값과 비교하였다. 수동관찰, 운동연상, 능동 관찰법에 따른 운동 유발 전위의 차이와 느리고 빠른 운동 속도에 따른 운동 유발 전위의 차이를 비교 분석하였다. 분석 결과 안정 시 보다 수동 관찰, 운동 연상 혹은 능동 관찰 모두에서 운동 유발 전위의 촉발이 일어나며, 능동적 관찰은 수동적 관찰에 비해 유의하게 높은 운동유발전위를 촉발이 일어나나, 빠르고 느린 동작에 있어 유의한 차이를 보이지 않음을 알 수 있었다.

COMPARATIVE STUDY OF SHEAR BOND STRENGTH BETWEEN CP-TI/CO-CR ALLOY AND COMPOSITE RESINS

  • Yoon, Se-Hee;Pae, Ahran;Lee, Seok-Hyung;Lee, Ho-Rim
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.805-814
    • /
    • 2007
  • Statement of problem. Composite resin-veneered metal restorations can be used as an alternative to porcelain-fused-metal restorations. But, because of the relatively low bond strength of veneering composite to metal framework, various surface treatment methods have been introduced to improve the bond strength. Purpose. The object of this study was to compare the shear bond strength of different combinations of each of the two bonding systems and each of the two composite veneering resins to cp-Ti/Co-Cr alloy. Material and methods. Two resin bonding systems (metal conditioner containing MEPS monomer, tribochemical silicoating system) and two composite resins (Gradia, Sinfony) were tested on cp-Ti and Co-Cr alloy. Then, according to manufacturers' instructions, resin bonding systems and composite resins were applied. All test specimens were divided into four groups for each alloy; I) sandblast + Metal Primer II + Gradia (MG), II) sandblast + Metal Primer II + Sinfony (MS), III) Rocatec + Gradia (RG), IV) Rocatec + Sinfony (RS). The shear bond strength was determined using a universal testing machine and all data were statistically analyzed with Mann-Whitney test and Kruskal-Wallis test at the significance level of 0.05. Results. The mean (standard deviations) of shear bond strength according to the combinations of two bonding systems and two composite resins to cp-Ti arranged from 16.44 MPa to 17.07 MPa and the shear bond strength to Co-Cr alloy ranged from 16.26 MPa to 17.70 MPa. The result shows that the difference were not statistically significant. Conclusion. The shear bond strengths of composite resins to both cast cp-Ti and Co-Cr alloy were not significantly different between the metal conditioner and the tribochemical silicoating system. And no differences in bond strength were found between cp-Ti and Co-Cr alloy.

An Electrode Configuration for Recording Muscle Motor Evoked Potentials in the Upper Extremities during Intraoperative Neurophysiological Monitoring

  • Choi, Young-Doo;Jin, Seung-Hyun;Kim, Chi-Heon;Kwak, Gil Ho;Kim, Bo Eun;Chung, Chun Kee
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권4호
    • /
    • pp.475-480
    • /
    • 2017
  • Objective : The main aim of the present study is to examine the electrode configurations used to record the muscle motor evoked potential (mMEP) in the upper extremities during surgery with the goal of producing a high and stable mMEP signal, in particular among the abductor pollicis brevis (APB), abductor digiti minimi (ADM), and across the APB-ADM muscles, which have been widely used for the mMEP in the upper extremities. Methods : Thirty right-handed patients were recruited in this prospective study. No patients showed any adverse events in their mMEP signals of the upper extremities during surgery. The mMEPs were recorded independently from the signals for the APB and ADM and for those across the APB-ADM. Results : The mMEP amplitude from across the APB-ADM was statistically higher than those recorded from the APB and ADM muscles. Moreover, the coefficient of variation of the mMEP amplitude from across the APB-ADM was smaller than those of mMEP amplitude recorded from the APB and ADM muscles. Conclusion : The mMEP from across the APB-ADM muscles showed a high yield with high stability compared to those in each case from the APB and ADM muscles. The configuration across the APB-ADM muscles would be best for mMEP recordings from the upper extremities for intraoperative neurophysiological monitoring purposes.

Successful Motor Evoked Potential Monitoring in Cervical Myelopathy : Related Factors and the Effect of Increased Stimulation Intensity

  • Shim, Hyok Ki;Lee, Jae Meen;Kim, Dong Hwan;Nam, Kyoung Hyup;Choi, Byung Kwan;Han, In Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권1호
    • /
    • pp.78-87
    • /
    • 2021
  • Objective : Intraoperative neurophysiological monitoring (IONM) has been widely used during spine surgery to reduce or prevent neurologic deficits, however, its application to the surgical management for cervical myelopathy remains controversial. This study aimed to assess the success rate of IONM in patients with cervical myelopathy and to investigate the factors associated with successful baseline monitoring and the effect of increasing the stimulation intensity by focusing on motor evoked potentials (MEPs). Methods : The data of 88 patients who underwent surgery for cervical myelopathy with IONM between January 2016 and June 2018 were retrospectively reviewed. The success rate of baseline MEP monitoring at the initial stimulation of 400 V was investigated. In unmonitorable cases, the stimulation intensity was increased to 999 V, and the success rate final MEP monitoring was reinvestigated. In addition, factors related to the success rate of baseline MEP monitoring were investigated using independent t-test, Wilcoxon rank-sum test, chi-squared test, and Fisher's exact probability test for statistical analysis. The factors included age, sex, body mass index, diabetes mellitus, smoking history, symptom duration, Torg-Pavlov ratio, space available for the cord (SAC), cord compression ratio (CCR), intramedullary increased signal intensity (SI) on magnetic resonance imaging, SI length, SI ratio, the Medical Research Council (MRC) grade, the preoperative modified Nurick grade and Japanese Orthopedic Association (JOA) score. Results : The overall success rate for reliable MEP response was 52.3% after increasing the stimulation intensity. No complications were observed to be associated with increased intensity. The factors related to the success rate of final MEP monitoring were found to be SAC (p<0.001), CCR (p<0.001), MRC grade (p<0.001), preoperative modified Nurick grade (p<0.001), and JOA score (p<0.001). The cut-off score for successful MEP monitoring was 5.67 mm for SAC, 47.33% for the CCR, 3 points for MRC grade, 2 points for the modified Nurick grade, and 12 points for the JOA score. Conclusion : Increasing the stimulation intensity could significantly improve the success rate of baseline MEP monitoring for unmonitorable cases at the initial stimulation in cervical myelopathy. In particular, the SAC, CCR, MRC grade, preoperative Nurick grade and JOA score may be considered as the more important related factors associated with the success rate of MEP monitoring. Therefore, the degree of preoperative neurological functional deficits and the presence of spinal cord compression on imaging could be used as new detailed criteria for the application of IONM in patients with cervical myelopathy.

Evidence of Cortical Reorganization in a Monoparetic Patient with Cerebral Palsy Detected by Combined Functional MRI and TMS

  • ;장성호
    • Journal of Yeungnam Medical Science
    • /
    • 제22권1호
    • /
    • pp.96-103
    • /
    • 2005
  • 뇌성마비로 인해 오른 손에서 단부전마비를 호소하는 환자를 대상으로 기능적 자기공명영상 장치와 경두개 자기 자극기를 사용하여 운동신경의 회복기전을 연구하였다. 대상자는 21세 된 남자 환자로 오른손에 경미한 운동 기능의 손상을 보였고, 자기공명영상의 소견에서 좌반구의 precentral knob에서 병변을 보였다. 기능적 자기공명영상 촬영은 한 명의 대상자와 여덟 명의 정상인을 대상으로 표준화된 헤드코일을 사용하여 1.5 T의 장치에서 BOLD 기술을 적용하여 실시하였다. 대상자들의 운동 수행은 1 Hz 주기로 손가락의 굴곡과 신전을 반복하는 과제가 제시되었다. 경두개 자기 자극은 원형 코일을 사용하여 코일의 앞쪽 부분이 대상자의 두피에서 1 cm 정도 떨어진 정접 부위에 적용되었고 양측의 짧은엄지벌림근에서 발생된 운동 유발 전위가 동시에 측정되었다. 자기공명영상의 결과에서 환자의 비손상측(좌측) 손과 정상군의 좌측 손의 운동 수행 시 오른쪽의 일차운동감각영역(SM1)의 precentral knob에서 활성도가 나타났다, 그러나, 환자의 손상측(우측) 손의 운동 수행 시, 좌측 일차운동감각영역의 손상된 precentral knob 내측 부위에서 활성도를 보였다. 또한, 경두개 자기 자극의 결과에서 손상측 짧은엄지벌림근에서 발생된 운동 유발 전위에 해당하는 뇌 부위가 환자의 정상측과 비교하여 1 cm 내측에서 발견되었다. 그러므로 손상측 손의 운동 기능이 손상된 precentral knob의 내측 부분으로 전위되어 신경재구성이 이루어진 것으로 추정되는 결론을 얻었다.

  • PDF

넙치 육성용 배합사료 개발을 위한 현장 사육 실험 (Development of Extruded Pellet for Growth of Flounder (Paralichthys olivaceus) in Commercial Scale Feeding Trials)

  • 서주영;최진;이종하;이상민
    • 한국양식학회지
    • /
    • 제20권2호
    • /
    • pp.114-120
    • /
    • 2007
  • 육성기 넙치 사육용으로 부상배합사료 및 생사료의 사육효과를 비교하기 위하여 2회에 걸친 사육실험을 실시하였다. 실험 1에서는 평균체중 115 g의 넙치를 5종류의 실험EP ($EP1{\sim}EP5$v와 생사료(MP)로 78일간 사육 실험하였으며, 실험 2는 양식현장에서 평균체중 137 g의 넙치를 실험 1에 사용한 5종류의 EP ($EP1{\sim}EP5$), 시판사료(EP6) 및 EP4와 EP6에 물과 각종 영양소를 흡착시킨 2종류 흡착-습사료(MEP4 및 MEP6)로 80일간 사육 실험하였다. 사육실험 결과, 실험 1에서 증중율은 모든 EP 실험구가 MP 실험구와 유의한 차이가 없었으며, EP4는 MP에 비하여 더 높은 값을 보였다. 사료효율은 EP4 실험구가 다른 실험구보다 유의적으로 높은 결과를 보였다(P<0.05). 등근육의 간과 수분함량 및 간의 지질함량은 실험구간에 유의한 차이를 보였다. 실험 2에서는 생존율은 $89{\sim}99%$의 범위로 양호한 결과를 보였다. 증중량은 EP4와 MEP4 실험구가 가장 높은 값을 보였으며, 그 다음으로 EP3과 MEP6 실험구가 양호한 결과를 보였다. 사료효율은 모든 실험구에서 108% 이상으로 양호하였으며, EP4, MEP4 및 MEP6에서 높은 값을 보였다. 이상의 결과들로부터, $114{\sim}350\;g$인 넙치에게 생사료를 기초로 제조된 MP를 공급하는 것 보다 영양소 균형이 잘 갖춰진 EP를 공급하여도 좋을 것으로 보이며, EP 공급시 물과 다른 영양소의 흡착과정은 불필요할 것으로 판단된다. 또한, MP와 상업용 EP 실험구에 비해 양호한 성장 결과를 보인 EP4는 MP 대체 실용사료로서 사용될 수 있을 것으로 기대된다.

니켈-크롬 합금에 대한 다용도 접착 시스템의 전단결합강도 (Shear bond strength of Universal bonding systems to Ni-Cr alloy)

  • 송소연;손병화;김종엽;신상완;이정열
    • 대한치과보철학회지
    • /
    • 제53권4호
    • /
    • pp.295-300
    • /
    • 2015
  • 목적: 레진과 니켈-크롬 합금의 결합력에 미치는 금속 프라이머 및 다용도 접착제의 영향에 대하여 비교 평가하고자 한다. 재료 및 방법: 실험을 위해 120개의 니켈-크롬 합금(Vera Bond 2V) 디스크를 제작하여 아크릴 레진 실린더에 포매하였다. 시편의 표면은 220 grit, 600 grit의 실리콘 카바이드지로 연마한 뒤 $50{\mu}m$의 알루미늄옥사이드 입자를 분사하여 처리하였다. 실험군은 메탈 프라이머의 적용(Metal primer II, Alloy primer, Metal & Zirconia primer, MKZ primer)과 다용도 접착 시스템(Single Bond Universal, All Bond Universal)에 따라 6개 군으로 나뉘었다. 각 시편의 중앙에 높이 2 mm, 직경 3 mm로 복합레진을 충전하였으며, 제작된 모든 시편은 $37^{\circ}C$ 증류수에서 24시간 보관하였다. 만능시험기에 시편을 위치시킨 후 1 mm/min cross head speed로 전단결합강도를 측정하였다. 통계분석은0.05의 유의수준으로 일원분산분석을 시행하였고 Tukey's multiple coMParison test로 사후검정을 하였다. 결과: Single Bond Universal, All Bond Universal, Metal Primer II 3개 군과 Alloy Primer, MKZ Primer, Metal & Zirconia Primer 3개 군 사이에 통계학적으로 유의한 차이를 보였다(P<.001). 결론: 니켈-크롬 합금에 대한 다용도 접착 시스템의 전단결합강도는 Metal Primer II를 제외한 기존의 금속 프라이머를 적용했을 때 보다 높게 나타났다. 본 실험에서 더 나아가 다용도 접착 시스템 내 실란(Silane) 포함 여부에 따른 효과를 평가할 수 있는 연구가 필요할 것이다.