Linking LOD and MEP Items towards an Automated LOD Elaboration of MEP Design

  • Shin, Minso;Park, SeongHun;Kim, Tae wan
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.768-775
    • /
    • 2022
  • Current MEP designs are mostly applied by 2D-based design methods and tend to focus on simple modeling or geometry information expression such as converting 2D-written drawings into 3D modeling without taking advantage of the strength of BIM application. To increase the demand for BIM-based MEP design, geometric information, and property information of each member of the 3D model must be conveniently linked from the phase of the Design Development (DD) to the phase of Construction Document (CD). To conveniently implement a detailed model at each phase, the detailed level of each member of the 3D model must be specific, and an automatic generation of objects at each phase and automatic detailing module for each LOD are required. However, South Korea's guidelines have comprehensive standards for the degree of MEP modeling details for each design phase, and the application of each design phase is ambiguous. Furthermore, in practice, detailed levels of each phase are input manually. Therefore, this paper summarized the detailed standards of MEP modeling for each design phase through interviews with MEP design companies and related literature research. In addition, items that enable auto-detailing with DYNAMO were selected using the checklist for each design phase, and the types of detailed methods were presented. Auto-detailing items considering the detailed level of each phase were classified by members. If a DYNAMO algorithm is produced that automates selected auto-detailing items in this paper, the time and costs required for modeling construction will be reduced, and the demand for MEP design will increase.

  • PDF

효과적인 포인트 클라우드 기반 건축 MEP 파이프 객체 역설계 처리를 위한 시스템 아키텍처 (System Architecture for Effective Point Cloud-based Reverse Engineering of Architectural MEP Pipe Object)

  • 강태욱
    • 한국산학기술학회논문지
    • /
    • 제15권9호
    • /
    • pp.5870-5876
    • /
    • 2014
  • 본 연구의 목적은 효과적인 건축 MEP(Mechanic, Electric and Plumbing) 파이프 객체 역설계 자동화를 위한 시스템 아키텍처를 제안하고, 프로토타입 개발을 통해 역설계 기술에서 향후 개선할 점을 도출하는 것이다. 이를 위해 역설계 작업에 필요한 요구사항, 유스케이스, 기능 및 클래스를 도출하였다. 도출된 기능을 바탕으로 건축 MEP파이프 객체 역설계를 위한 아키텍처를 설계하였으며, 시스템의 정적 구조, 알고리즘을 설계하였다. 제안된 시스템 아키텍처를 기반으로 한 프로토타입 개발 연구를 통해 향후 개선할 점을 도출하였으며, 일반적인 파이프 유형은 RANSAC(RANdom SAmple Consensus)등 일반적인 역설계 방법으로 처리가 가능하지만, 이형 파이프와 대용량 데이터 처리를 위한 공간 인덱싱 기반 LOD(Level Of Detail)기법이 별도로 고려될 필요가 있다는 것을 확인하였다.

An Osteolytic Meningioma en Plaque of the Sphenoid Ridge

  • Baek, Jin-Uk;Cho, Young-Dae;Yoo, Jae-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • 제43권1호
    • /
    • pp.34-36
    • /
    • 2008
  • Meningioma en plaque (MEP) is a rare tumor characterized more by its clinical and biological behavior than its histological appearance. Hyperostosis of the skull is one of the characteristic signs of MEP. This bony change can produce clinical symptoms and signs in MEP by pressing against adjacent structures. The authors report a rare case of an osteolytic MEP extending from the sphenoid wing into the orbital wall, middle fossa, and temporalis muscle.

허혈성 뇌졸중 환자에서 Magnetic Stimulation에 의한 운동유발전위 반응 (Motor Evoked Potential Study with Magnetic Stimulation in Ischemic Stroke Patients)

  • 김성민;서상덕;이준;하정상
    • Journal of Yeungnam Medical Science
    • /
    • 제11권2호
    • /
    • pp.248-261
    • /
    • 1994
  • 허혈성 뇌졸중 환자에서 운동장애의 판단 및 예후 판정에 운동유발전위 (motor evoked potential : MEP)의 유용성을 알아보기 위해 정상대조군 24례와 허혈성 뇌졸중 환자 24례를 대상으로 대뇌피질 및 척추부위에 자기자극을 가하며 단모지외전근 및 무지외전근에서 MEP를 기록하였고 각각의 근육에서 대뇌피질을 자극하여 기록된 MEP의 잠복기에서 척추부위를 자극하여 기록된 MEP의 잠복기를 감한 차이로 CMCT를 산출하였다. 대조군은 24례 모두에게 MEP를 유발할 수 있었고 환자군에서는 24폐 중 무반응을 나타낸 경우가 각 근육에서 11례였다. 정상대조군과 MEP를 유발할 수 있었던 뇌졸중 환자에서 단모지외전근에서의 평균 CMCT는 각각 $8.6{\pm}1.4$msec, $9.4{\pm}2.3$msec로 통계적 유의성은 없었고, 무지외전근에서는 $15.1{\pm}2.1$msec, $18.8{\pm}3.9$msec로 유의한 차이를 보였다(p<0.01). 허혈성 뇌졸중 환자에서 추체로 또는 중심피질 병변일 때 혹은 급성기의 운동장애가 심할 때 대뇌피질 자기자극에 무반응을 보인 경우가 많았고, 추체로를 제외한 피질하 병변일 때 혹은 경한 운동장애를 보일 때 CMCT가 정상인 경우가 많았다. 운동장애를 보였던 환자중 급성기의 CMCT가 정상인 경우는 1~2개월 후 상당한 운동회복을 보였고 대뇌피질 자기자극에 반응이 없을 때 운동회복은 미약하였다. 이로 미루어 MEP는 안전하고 간편한 중추성 운동신경계 전달경로의 전기생리학적 검사로써 뇌졸중환자의 운동장애를 판단하는 데 도움을 주고 급성기 운동장애의 예후를 예측하는 데 하나의 지표가 될 수 있을 것이라 사료된다.

  • PDF

Intraoperative Monitoring of Motor-Evoked Potentials for Supratentorial Tumor Surgery

  • Lee, Jung Jae;Kim, Young Il;Hong, Jae Taek;Sung, Jae Hoon;Lee, Sang Won;Yang, Seung Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권2호
    • /
    • pp.98-102
    • /
    • 2014
  • Objective : The purpose of this study was to assess the feasibility and clinical efficacy of motor evoked potential (MEP) monitoring for supratentorial tumor surgery. Methods : Between 2010 and 2012, to prevent postoperative motor deterioration, MEP recording after transcranial stimulation was performed in 84 patients with supratentorial brain tumors (45 males, 39 females; age range, 24-80 years; median age, 58 years). MEP monitoring results were correlated with postoperative motor outcome compared to preoperative motor status. Results : MEP recordings were stable in amplitude (<50% reduction in amplitude) during surgery in 77 patients (91.7%). No postoperative motor deficit was found in 66 out of 77 patients with stable MEP amplitudes. However, postoperative paresis developed in 11 patients. False negative findings were associated with edema in peri-resectional regions and postoperative bleeding in the tumor bed. MEP decrease in amplitude (>50%) occurred in seven patients (8.3%). However, no deficit occurred postoperatively in four patients following preventive management during the operation. Three patients had permanent paresis, which could have been associated with vascular injury during tumor resection. Conclusions : MEP monitoring during supratentorial tumor surgery is feasible and safe. However, false negative MEP results associated with postoperative events may occur in some patients. To achieve successful monitoring, collaboration between surgeon, anesthesiologist and an experienced technician is mandatory.

BIM기반 MEP공사 시공용 도면 작성 자동화 프로세스 제안 (An Automated Process to Produce Shop Drawings for MEP Works in BIM Environment)

  • 최창현;권대용;조상호;김주형
    • 한국BIM학회 논문집
    • /
    • 제10권4호
    • /
    • pp.22-31
    • /
    • 2020
  • Shop drawing tasks conducted after finishing coordinated or engineering design have great influences on the quality and cost of a project. However, despite the development of commercial BIM applications, shop drawings have mainly produced manually in certain engineering fields. Incorrect shop drawings with human errors have occurred various problems such as cost overrun, time delay and reworks. An automated shop drawing publishing from BIM is expected to resolve these problems. Despite attempts for automate shop drawing production, the field of mechanical, electrical and plumbing (MEP) is yet regarded challenging due to complexity of components and connection. In this research, we develop a process for automated producing 3D MEP shop drawings in BIM environment as following steps: to analyze conventional MEP shop drawing process, to identify detailed process that can be automated, to classify existing MEP objects and assign codes usable in BIM, and to develop an application. The validation of automated process is conducted against 10 clean room projects in which MEP is more complex and its cost is higher than other projects in terms of productivity and workers' satisfaction. Results show that the number of manpower for shop drawing is reduced by 30%, and the working time is shortened by 31%. Personal opinions of involved practitioners is interpreted as positive as the average rate of agrement on practicability, easy-to-use and necessary retouch tasks is around 66%.

한의 진단을 위한 체표에너지 측정 시스템의 개발 및 평가 (Development and Evaluation of Body Surface Electric Energy Measurement System for Oriental Medical Diagnosis)

  • 김수병;권선민;강희정;임윤경;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제26권1호
    • /
    • pp.51-60
    • /
    • 2009
  • Objectives : It is considered not easy to diagnose the condition of acupoints or meridians. Oriental Medical instruments have rarely complied with Oriental Medical diagnostic/therapeutic theories. The aim of this study was to develop a system which measures meridian electric potential(MEP) in proportion to bio-electric charge for the purpose of Oriental Medical diagnosis. Method : To evaluate a meridian energy measurement system(MEMS), we carried out a performance test. For significance test, we conducted a clinical trial which measured the MEP of ST36(Chok-samni) on Stomach Meridian(ST). Results & Conclusions : We could evaluate the balance or the imbalance of the MEPs on the left/right ST36. Also, through the comparison of MEPs before and after meals, we could identify the correlation between the MEP and the condition of internal organs. Namely, MEP reflects the condition of acupoints/meridians and internal organs, therefore, we propose this new method for measuring and analyzing the condition of meridians and acupoints for Oriental Medical diagnosis.

  • PDF

국내 MEP 분야 BIM 활용 실태 조사 및 실무 적용 활성화 방안 제시 (A Study on Strategy and Utilization for Practical Application of BIM in MEP Area)

  • 김이제;김용인;김인채;진상윤
    • 한국BIM학회 논문집
    • /
    • 제10권4호
    • /
    • pp.70-80
    • /
    • 2020
  • In the MEP(Mechanical Electrical and Plumbing) field, the utilization of BIM-based drawings is lower than in the architectural and structural sectors, and the limited BIM collaboration problem caused by different levels of BIM utilization in each field is becoming a serious problem in adoption and utilizing BIM. Therefore, this study analyzed the current status of BIM application in the field of mechanical equipment in the construction industry and analyzed the practical problems and limitations of adoption and utilizing BIM from a corporate perspective based on Delphi analysis techniques. Based on the results of the analysis, the limitations of the current MEP BIM application were classified into economic, technical, institutional, and social factors to derive detailed items, and, accordingly, the improvement measures were classified as institutional, policy, and technical measures. As a result, the company intends to maximize the value of BIM utilization in the MEP field by presenting improvement plans to activate BIM in the field of mechanical equipment based on the opinions of the company, thereby laying the foundation for BIM in the construction industry by creating a collaborative BIM environment for each sector in the domestic construction industry.

자화침 시스템을 이용한 경락전위 유발효과 및 근피로 회복 평가 (Evaluation of Muscle Fatigue Recovery Effect and Meridian Potential Change using Magnetic Acupuncture System)

  • 김수병;박선우;안순재;이나라;이승욱;민세은;김영호;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제29권1호
    • /
    • pp.83-92
    • /
    • 2012
  • Objectives : The purpose of this research was to develop the magnetic acupuncture system which used solenoid coil for magnetizing acupuncture needle. The system could generate the meridian electric potential (MEP) similar to the potential by manual acupuncture. Thus, we tried to confirm the therapeutic effect that is caused by the MEP generation. Methods : To confirm the MEP, we stimulated the magnetic acupuncture with at 2Hz, $92.7{\pm}2mT$, PEMFs (Pulsed Electro-Magnetic Fields) at ST37 and measured the evoked potential between ST36 and ST41. Also, we conducted a fatigue recovery test using isokinetic exercise in order to identify the therapeutic effect on musculoskeletal disorders. We chose LR9 as a stimulation point. To observe the state of fatigue, we measured the EMG and analyzed median frequency and peak torque for 20minutes. Results : We observed that MEP which incurred from magnetic acupuncture was higher than he reported MEP induced by manual acupuncture. Moreover, its modes were divided into two types by the direction of magnetic flux. When generating magnetic flux in the direction of acupoint, the positive peak voltage of the MEP was generated. In contrast, negative peak voltage of the MEP was generated whenever meganetic flux generated in the outward direction. As a result of fatigue recovery, the median frequency (MF) of the magnetic acupuncture group were recovered faster than that of the non-stimulation group. However, the peak torques of both groups were not restored until after 20 minutes. Conclusions : We confirmed that the magnetic acupuncture system can lead to the MEP similar to manual acupuncture. Moreover, the MEP had a therapeutic effect on the musculoskeletal disorders.

근위축성 측상경화증 환자에서 등세모근의 신경생리학적 검사 (The Electrophysiological Studies of the Trapezius Muscle in Patients with Amyotrophic Lateral Sclerosis)

  • 조중양;전종은;이광우
    • Annals of Clinical Neurophysiology
    • /
    • 제6권2호
    • /
    • pp.85-91
    • /
    • 2004
  • Background: Needle electromyography (EMG) and motor evoked potential (MEP) of the genioglossus (tongue) are difficult to perform in evaluations of the craniobulbar region in amyotrophic lateral sclerosis (ALS). Therefore, we investigated the yields of needle EMG and MEP recorded from the upper trapezius, since it receives innervation from the lower medulla and upper cervical cord. Methods: Needle EMG and MEP of the upper trapezius were obtained in 17 consecutive ALS patients. The needle EMG parameters recorded included abnormal spontaneous activity and motor unit action potential (MUAP) morphology. An upper motor neuron (UMN) lesion was presumed when either response to cortical stimulation was absent, or the central conduction time was delayed (>mean+2SD). Results: Of the five patients with bulbar-onset ALS, four had abnormalities in the upper trapezius and four in the tongue by needle EMG. In contrast, of the 12 patients with limb-onset ALS, 11 had abnormalities in the upper trapezius, and only five in the tongue. When MEP was performed, it was found that three of the five patients with bulbar symptoms and three of the six patients with isolated limb involvement had abnormal MEP findings. Conclusions: Electrophysiological studies of the upper trapezius are more sensitive those of the tongue in patients without bulbar symptoms. Thus, needle EMG and MEP of the upper trapezius are alternative tools for assessing bulbar and rostral neuraxial involvement in the diagnosis of ALS.

  • PDF