Cost Management System for Mechanical, Electrical, and Plumbing(MEP) Coordination Using Building Information Modeling(BIM) - A Case Study (BIM 기반 MEP 설계 조율 프로세스 분석을 통한 비용 관리 시스템 개발 사례 연구)

  • Won, Jongsung;Ham, Sungil;Jang, Sejun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.2
    • /
    • pp.195-205
    • /
    • 2022
  • This paper aims to propose a cost-based mechanical, electrical, and plumbing(MEP) coordination process using building information modeling(BIM). The proposed process can help project participants eliminate identified clashes between the MEP elements, analyze trends relating to MEP costs during the coordination process, and share their findings. MEP quantity-related information extracted through BIM was integrated with the cost database and schedule information. To check the applicability of the proposed process, it was applied to a construction project in South Korea. Through the application of the proposed process, MEP-related cost was reduced.

Study on 3D Reverse Engineering-based MEP Facility Management Improvement Method (3차원 역설계 기반 MEP 시설물 관리 작업 개선 방안 도출)

  • Kang, Tae-Wook;Kim, Ji-Eum;Jung, Taek-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.38-45
    • /
    • 2016
  • The objective of this research is to develop a method of improving MEP facility management based on 3D reverse engineering. Recently, 3D image scanning-based reverse engineering has been implemented in the fields of architecture, construction and (manufacturing). In the case where there are many objects and the MEP system is complicated, 3D reverse engineering is applied in semiconductor factories, because facility maintenance works cause the 2D drawing to be different from the original one. The 3D point cloud data obtained from 3D image scanning contains accurate data and can increase the efficiency of complicated MEP facility maintenance works. For this purpose, the present research studied the technology trends and analyzed the process of 3D reverse engineering. Based on the results, a method of improving MEP facility management is established and its effects described.

Identification of target subjects and their constraints for automated MEP routing in an AEC project

  • Park, SeongHun;Shin, MinSo;Kim, Tae wan
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.776-783
    • /
    • 2022
  • Since Mechanical, Electrical, and Plumbing(MEP) routing is a repetitive and experience-centered process that requires considerable time and human resources, if automated, design errors can be prevented and the previously required time and human resources can be reduced. Although research on automatic routing has been conducted in many industries, the MEP routing in AEC projects has yet to be identified due to the complexity of system configuration, distributed expertise, and various constraints. Therefore, the purpose of this study is to identify the target subjects for MEP routing automation and the constraints of each subject. The MEP design checklist provided by a CM company and existing literature review were conducted, and target subjects and constraints were identified through process observation and in-depth expert interviews for five days by visiting a MEP design company. The target subjects were largely divided into six categories: air conditioning plumbing, air conditioning duct, restroom sanitary plumbing, heating plumbing, and diagram. The findings from interviews show that work reduction and error reduction has the greatest effect on air conditioning plumbing while the level of difficulty is the highest in air conditioning duct and restroom sanitary plumbing. Major constraints for each subject include preventing cold drafts on air conditioning pipes, deviation in ventilation volume in air conditioning ducts, routing order on restroom sanitary plumbing, and separation distance from the wall on heating plumbing. In this way, subjects and constraints identified in this study can be used for MEP automatic routing.

  • PDF

Study on 3D Image Scan-based MEP Facility Management Technology (3차원 이미지 스캔 기반 MEP 시설물 관리 기술 연구)

  • Kang, Tae Wook
    • Journal of KIBIM
    • /
    • v.6 no.4
    • /
    • pp.18-26
    • /
    • 2016
  • Recently, for the purpose of maintenance of facilities and energy, there have been growing cases of the 3D image scan-based reverse design technology mostly in the manufacturing field. In the MEP field, because of differences between design and physical model, the reverse technology has been utilized in factory facilities such as a semiconductor factory. Because 3D point clouds from scanning include accurate 3D object information, the efficiency of management works related to the complex MEP facilities can be enhanced. In this study, the reverse technology was surveyed, and the MEP facility management based on 3D image scanning was analyzed. Based on the results, a method of 3D image scan-based MEP facility management was proposed.

Deriving Critical Management Factors based on Case Studies of Multi-trade MEP Ceiling Rack Prefabrication (복합공종 MEP 천정 선조립 공법 사례조사를 통한 단계별 중점관리사항 도출)

  • Lee, Dongmin;Jang, Sejun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.76-77
    • /
    • 2015
  • In construction industry, management of construction factors such as cost, schedule, quality and safety is the most important key for delivering successful projects. According to the Smart Market Report, a magazine specialized in construction industry, recently said 'Off-site Prefabrication' is a significant trend related with construction productivity in global construction industry. It is a kind of practice shift from On-site to Off-site. A lot of general contractors in oversea have been using 'Multi-trade MEP Ceiling Rack Prefabrication' method for getting benefits such as decreased cost & schedule and increased labor productivity. Thus, in this paper, critical management factors at each phase from design to installation was derived by researching case studies. Forwardly, it can be a basic guideline for applying Multi-trade MEP Ceiling Rack Prefabrication in Korea construction industry.

  • PDF

Design and Verification of Mission Equipment Package System for Korean Utility Helicopter (한국형 기동헬기 임무탑재장비체계 설계 및 입증)

  • Kim, Sung-Woo;Lee, Byoung-Hwa;Yu, Yeon-Woon;Lee, Jong-Hoon;Yim, Jong-Bong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.388-396
    • /
    • 2011
  • Mission Equipment Package(MEP) system is a collection of avionic components that are integrated to perform the mission of the Korean Utility Helicopter(KUH). MEP system development is classified mission-critical embedded system but KUH MEP system developed including flight-critical data implementation. It is important to establish the good development and verification process for the successful system development. This paper describe the development and verification process in each phase for the KUH MEP system. MEP system design is verified through the qualification test, system failure test and compatibility test in System Integration Laboratory(SIL).

Comparative Analysis of 3D Laser Scanning and MEP Layout for Measurement of Horizontal Displacement of Structures (구조물 수평변위 계측을 위한 3D Laser scanning과 MEP layout의 비교 분석)

  • Shim, Hak-Bo;Seok, Won-Kyun;Park, Soon-Jeon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.183-183
    • /
    • 2020
  • MEP layout and 3D Laser scanning are widely used equipment for displacement measurement in construction site. In this study, MEP layout and 3D Laser scanning were used to measure the lateral displacement of the same structure, and then the advantages and disadvantages of each were compared and analyzed. In general, it has been shown that MEP layout can save a lot of time compared to 3D Laser scanning. And it was found that the lateral displacement measurement results measured at a distance of 15m were similar to each other.

  • PDF

Change of Magnetic Motor Evoked Potentials in Hemiparesis due to Cerebral Infarction (뇌경색에 의한 편측부전마비에서 자기운동유발전위의 변동)

  • Lee, Ju Ho;Park, Young Huk;Kim, Kwang Soo;Yoo, Kyung Moo
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.2
    • /
    • pp.99-105
    • /
    • 1999
  • Background and Objectives : The Motor evoked potentials (MEP) study may be useful in the evaluation of the degree of impairment in the motor nervous system and in the determination of the prognosis. The purpose of this study is to evaluate the status of central nervous system in acute and subacute state of cerebral ischemia by comparing the changes of MEP in the initial and follow-up study. Methods : Twenty patients with hemiparesis caused by ischemic stroke were recruited for this study. We tested MEP within 7 days and followed-up after 14 days after symptom onset. The cerebral motor cortex area, cervical area for upper extremity and lumbar area for lower extremity were stimulated by transmagnetic stimulator. The central motor conduction time(CMCT) was measured with the difference in MEP caused by stimulating the vertical area and spinal area. The CMCT of hemiparetic patients were classified into three groups-normal, delayed, and no evoked MEP groups. Results : The CMCT in hemiparetic side of acute ischemic stroke patients were singnificantly delayed (P < 0.05) compared with the control group. The CMCT of hemiparetic side in the follow-up study showed no sinificantly difference in comparison to the control group. The prognosis of motor improvement was better in the groups of delayed MEP than the groups of no evoked MEP. Conclusion : The CMCT of hemiparetic and contralateral sides were delayed in acute ischemic stroke, compared with control group and were returned to normal boundaries in subacute state. But in the most cases with no MEP response in the initial study, also showed no MEP response in the follow-up study. The recovery occurred in the subacute state in cases with mild hemiparesis, whereas recovery did not occur in the subacute stage in case with severe hemiparesis.

  • PDF

Lower Motor Neuron Hyperexcitability in Amyotrophic Lateral sclerosis: Analysis Using Motor Evoked Potentials (근위축성 측삭 경화증의 하 운동 신경원 과흥분성: 운동유발전위를 이용한 분석)

  • Bae, Jong-Seok;Hong, Suk-Chan;Kim, Min-ky;Kim, Byoung-Joon
    • Annals of Clinical Neurophysiology
    • /
    • v.5 no.1
    • /
    • pp.21-26
    • /
    • 2003
  • Background & Objectives: Hyperexcitablity of motor system is a well-established characteristic pathophysiologic finding of amyotrophic lateral sclerosis (ALS). Whereas little is known about the source of excitability according to the progression of the disease. We evaluated the excitability and its source in advanced ALS patients using transcranial magnetic stimulation (TMS). Meterial & Methods: Motor evoked potentials (MEP) by TMS were recorded for abductor pollicis brevis muscles in 20 patients, 11 men and 9 women, with ALS. Mean age was $54.2{\pm}12.1years$, and mean disease duration was $13.9{\pm}13.4years$. Serial magnetic stimulations were applied to get the parameters; excitability threshold (ET), amplitude and latency of MEP. We also had a facilitated MEP (fMEP). Results: The parameters were analyzed according to the clinical settings. ET was higher in ALS(mean $63.5{\pm}18.1$) than normal control (mean $46.0{\pm}8.4$, p<0.01). Amplitudes of MEP were reduced in ALS ($2.6{\pm}3.6mV$; control $6.5{\pm}3.1mV$, p<0.01). Duration of the disease and ET showed significant inverse correlation (Spearson correlation coefficient = -0.57, p<0.01). Duration of the disease and fMEP/MEP ratio showed less but also significant inverse correlation (Spearson correlation coefficient, r = -0.52, p < 0.05). Conclusions: Lower ET in advanced ALS patients, in spite of decreased fMEP/MEP ratio, may indicate the hyperexcitability of lower motor neurons in these patients. This study suggests that lower motor neurons is hyperexcitable due to upper motor neuron dysfunction at advanced stage.

  • PDF

An Electrode Configuration for Recording Muscle Motor Evoked Potentials in the Upper Extremities during Intraoperative Neurophysiological Monitoring

  • Choi, Young-Doo;Jin, Seung-Hyun;Kim, Chi-Heon;Kwak, Gil Ho;Kim, Bo Eun;Chung, Chun Kee
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.475-480
    • /
    • 2017
  • Objective : The main aim of the present study is to examine the electrode configurations used to record the muscle motor evoked potential (mMEP) in the upper extremities during surgery with the goal of producing a high and stable mMEP signal, in particular among the abductor pollicis brevis (APB), abductor digiti minimi (ADM), and across the APB-ADM muscles, which have been widely used for the mMEP in the upper extremities. Methods : Thirty right-handed patients were recruited in this prospective study. No patients showed any adverse events in their mMEP signals of the upper extremities during surgery. The mMEPs were recorded independently from the signals for the APB and ADM and for those across the APB-ADM. Results : The mMEP amplitude from across the APB-ADM was statistically higher than those recorded from the APB and ADM muscles. Moreover, the coefficient of variation of the mMEP amplitude from across the APB-ADM was smaller than those of mMEP amplitude recorded from the APB and ADM muscles. Conclusion : The mMEP from across the APB-ADM muscles showed a high yield with high stability compared to those in each case from the APB and ADM muscles. The configuration across the APB-ADM muscles would be best for mMEP recordings from the upper extremities for intraoperative neurophysiological monitoring purposes.