• 제목/요약/키워드: MASS

검색결과 36,092건 처리시간 0.049초

Preprocessing and mass evolution of dark halos in the hydrodynamic zoom-in simulation

  • 한산;;최호승;;;;이석영
    • 천문학회보
    • /
    • 제43권2호
    • /
    • pp.38.2-38.2
    • /
    • 2018
  • To understand the assembly of the galaxy population in clusters today, it is important to first understand preprocessing, the impact of environments prior to cluster infall. We use 15 cluster samples from YZiCS, a hydrodynamic cluster zoom-in simulation to determine the significance of preprocessing, and focus on the tidal mass loss of dark matter halos. We find ~48% of the cluster member halos were once satellites of another host. The preprocessed fraction depends on each cluster's recent mass growth history. Also, we find that the total mass loss is a clear function of the time spent in a host. However, two factors can increase the mass loss rate considerably. First, if the satellite mass is approaching the mass of its host. Second, when the halo suffers tidal mass loss at a higher redshift. Being in hosts before cluster infall enables halos to experience tidal mass loss for an extended period of time.

  • PDF

우주환경하에서의 진동자의 주파수 변화 측정에 의한 질량 측정 시스템 및 방법

  • 김연규;김종우;김광식;최기혁
    • 항공우주기술
    • /
    • 제4권2호
    • /
    • pp.216-219
    • /
    • 2005
  • 이 논문은 무중력환경에서 작은 질량을 측정하기 위한 시스템의 설계와 테스트 결과 분석을 보여준다. 무중력환경에서는 지상에서와 같이 중력에 이용하여 무게를 측정하는 것은 어렵다. 그래서 여기서 제안된 방법은 측정하고자 하는 샘플의 무게에 대한 함수인 공진주파수를 측정하는 것이다. 우리가 무게에 대한 공진주파수를 안다면 샘플의 공진주파수를 측정하여 그 질량을 알 수 있다. 그래서 피에조 세라믹이라는 물질을 이용하여 시스템을 만든 후 실제로 측정하였다. 이 시스템은 여러 문제가 있었지만, 우리는 미지의 물체의 질량을 측정할 수 있었다.

  • PDF

Semi-active control of seismic response of a building using MR fluid-based tuned mass damper

  • Esteki, Kambiz;Bagchi, Ashutosh;Sedaghati, Ramin
    • Smart Structures and Systems
    • /
    • 제16권5호
    • /
    • pp.807-833
    • /
    • 2015
  • While tuned mass dampers are found to be effective in suppressing vibration in a tall building, integrating it with a semi-active control system enables it to perform more efficiently. In this paper a forty-story tall steel-frame building designed according to the Canadian standard, has been studied with and without semi-active and passive tuned mass dampers. The building is assumed to be located in the Vancouver, Canada. A magneto-rheological fluid based semi-active tuned mass damper has been optimally designed to suppress the vibration of the structure against seismic excitation, and an appropriate control procedure has been implemented to optimize the building's semi-active tuned mass system to reduce the seismic response. Furthermore, the control system parameters have been adjusted to yield the maximum reduction in the structural displacements at different floor levels. The response of the structure has been studied with a variety of ground motions with low, medium and high frequency contents to investigate the performance of the semi-active tuned mass damper in comparison to that of a passive tuned mass damper. It has been shown that the semi-active control system modifies structural response more effectively than the classic passive tuned mass damper in both mitigation of maximum displacement and reduction of the settling time of the building.

Comparison Study of Sensitivity Factors of Elements in Glow Discharge- & Inductively Coupled Plasma- Mass Spectrometry

  • Kim, Young-Sang;Plotnikov, M.;Hoffmann, Volker
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권12호
    • /
    • pp.1991-1995
    • /
    • 2005
  • Sensitivity factors of elements by a glow discharge mass spectrometry (GD-MS) were intensively investigated and compared with a laser ablation inductively coupled plasma-mass spectrometry (ICP-MS). In case of copper matrix, the sensitivity factor by GD-MS generally decreases with the increase of the mass number of element. The details are a little different between each data measured by Faraday and multiplier detectors. The factor by a multiplier detector drastically decreases with the mass increase in the region of low mass as in Faraday detector’s case, but slowly in the high mass region. On the contrast, the sensitivity factor of solution standard by a conventional ICP-MS slowly increases with the increase of elemental mass number even though there are some exceptions such as gold and also the sensitivity factor by a laser ablation ICP MS generally increases with mass number of element in the specimen of glass type. In case of steel matrix, any definite trends could not be shown in the relationship between the GD-MS’s sensitivity factor and elemental mass.

초기 변위를 가지고 연속 이동하는 스프링-질량계가 등분포종동력을 받는 단순지지보의 동특성에 미치는 영향 (Influence of Two Successively-moving Spring-mass Systems with Initial Displacement on Dynamic Behavior of a Simply-supported Beam Subjected to Uniformly Distributed Follower Forces)

  • 윤한익;강혁준;유진석
    • 한국소음진동공학회논문집
    • /
    • 제13권3호
    • /
    • pp.202-209
    • /
    • 2003
  • A simply supported beam subjected to a uniformly distributed tangential follower force and the two successively moving spring-mass systems upon it constitute this vibration system. The influences of the velocities of the moving spring-mass system, the distance between two successively moving spring-mass systems and the uniformly distributed tangential follower force have been studied on the dynamic behavior of a simply supported beam by numerical method. The uniformly distributed tangential follower force is considered within its critical value of a simply supported beam without two successively moving spring-mass systems, and three kinds of constant velocities and constant initial displacement of two successively moving spring-mass systems are also chosen. Their coupling effects on the transverse vibration of the simply supported beam are inspected too. In this study the simply supported beam is deflected with small vibration proportional to natural frequency of the moving spring-mass systems. According to the increasing of initial displacement of the moving spring-mass systems the amplitude of the small vibration of the simply supported beam is increased due to the spring force. The velocity of the moving spring-mass system more affect on the transverse deflection of simply supported beam than other factors of the system and the effect is dominant at high velocity of the moving spring-mass systems.

이중에너지 방사선 흡수계측법(DEXA)을 이용한 성인들의 체구성과 골밀도 분석 (The analysis of body composition and bone mineral density in adult by using dual energy X-ray absorptiometry)

  • 이중철;한상완
    • The Journal of Korean Physical Therapy
    • /
    • 제15권4호
    • /
    • pp.466-478
    • /
    • 2003
  • This study was to evaluate the body composition and bone mineral density according to aging in adult and investigated the relationship between various parameters such as body mass index(BMI), bone mineral density(BMD), bone mineral content(BMC), lean body mass(LBM), fat mass(FM) and the value obtained from dual energy X-ray absorptiometry(DEXA). The subjects were composed of healthy adult male and female who were $20^{\sim}73$ years old and they were divided three group according to age (A group : 20-39 yrs., B group : 40-59 yrs., C group : more than 60 yrs.). The conclusion derived from statistical analysis was as follows : 1. Bone mineral content and density were significantly affected by lean body mass(relatively, R=0.85 - 0.63). 2. There was significant difference among age groups in total bone mineral density. 3. There was significant difference among age groups in bone mineral content of male and female. 4. Lean body mass is diminished according to age, but there was not significant difference among age groups. 5. Fat mass of A group in male had the highest mass and followed by C group and B group. In female groups, fat mass of A group had the highest mass and followed by B group and C group. Abdominal fat mass is increased according to age. This result suggest that aging was closely relation with loss of muscle mass, bone mineral density and bone mineral content.

  • PDF

오리피스 노즐 수직 2 상 유동의 물질전달 특성 (Mass Transfer Characteristics of Vertical Two-Phase Flows with Orifice Nozzle)

  • 김동준;양희천
    • 대한기계학회논문집B
    • /
    • 제39권10호
    • /
    • pp.817-824
    • /
    • 2015
  • 본 논문은 수직 오리피스 노즐의 유동 및 물질전달 특성에 대한 실험적 연구를 목적으로 한다. 구동유체 및 부유체의 유량, 용존산소 농도 그리고 소비 전력을 측정하였으며, 고속 카메라를 이용한 직접 촬영 기법으로 수직 혼합유동의 가시화 이미지를 획득하였다. 측정자료를 이용하여 질량비, 총괄 산소전달 계수 그리고 물질전달 성능계수를 도출하였다. 구동압력이 증가하면 질량비는 약간 감소하는 반면에, 산소전달 계수와 소비전력은 증가하였다. 구동압력이 증가하고 질량비가 작아지면, 기포의 미세화가 촉진되고 확산도가 증대되기 때문에 산소 전달율이 증가하였다.

다합금계 백주철의 탄화물 및 기지조직이 내마모성에 미치는 영향 (Effects of Carbide and Matrix Structures on Abrasion Wear Resistance of Multi-Component White Cast Iron)

  • 류성곤
    • 한국재료학회지
    • /
    • 제7권4호
    • /
    • pp.310-316
    • /
    • 1997
  • The effects of carbide and matrix structures on the abrasion wear resistance of multi-component white cast irons with 3.0 mass%C have been studied in this paper. Four different heats were poured in order to obtain the specimens with different combinations of the carbide structures: a basic iron(3.0 mass%C-5.0 mass%Cr-5.0 mass%V-5.0 mass% Mo-12.5mass%W)for M$_{6}$C and M$_{7}$C$_{3}$ carbides, and a Cr free iron(3.0 mass%C-5.0 mass%V-2.5mass%Mo-12.5 mass%W) for MC and M6C carbides. A conventional high Cr free free iron(3.0 mass%C-5.0 mass%V-2.5 mass%Mo-12.5 mass%W) for MC and M6C carbides. A conventional high Cr white cast iron was also poured to compare its wear resistance with those of the multi-component white cast irons. In the as-cast condition, the range of abrasive wear rate(Rw=mg/min) was from 4.15 to 5.98 . The lowest Rw, which means the highest wear resistance, was obtained in the basic iron with nodular MC, lamellar M$_{2}$C and cellular M$_{7}$C$_{3}$ carbides. On the other hand, the Rw of the high Cr white cast iron ranked between the basic iron and the Mo and W free iron. In each alloy, the Rw of air hardened or tempered specimen was lower than that of the as-cast one because of the change of matrix structures by the heat treatments. The Rw of the hear treated speci-mens increased in the order Mo and W free iron, basic iron, Cr free iron, high Cr iron, and V free iron.n.n.n.

  • PDF

의지 보행시 의지 무게 분포가 근골격계에 미치는 영향 (Effects of Prosthetic Mass Distribution on Musculoskeletal System during Amputee Gait)

  • 배태수;최환;김신기;문무성
    • 한국정밀공학회지
    • /
    • 제24권8호통권197호
    • /
    • pp.130-137
    • /
    • 2007
  • The optimized prosthetic mass distribution was a controversial problem in the previous studies because they are not supported by empirical evidence. The purpose of the present study was to evaluate the effect of prosthetic mass properties by modeling musculoskeletal system, based on the gait analysis data from two above-knee amputees. The joint torque at hip joint was calculated using inverse dynamic analysis as the mass was changed in knee and foot prosthetic components with the same joint kinematics. The results showed that the peak flexion and abduction torque at the hip joint were 5 Nm and 15 Nm when the mass of the knee component was increased, greater than the peak flexion and abduction torque of the control group at the hip joint, respectively. On the other hand, when the mass of the foot component was increased, the peak flexion and abduction torque at the hip joint were 20 Nm and 15 Nm, greater than the peak flexion and abduction torque of the control, respectively. The hip flexion torque was 4.71-fold greater and 7.92-fold greater than the hip abduction torque for the knee mass increase and the foot mass increase on the average, respectively. Therefore, we could conclude that the effect of foot mass increase was more sensitive than that of knee mass increase for the hip flexion torque. On the contrary, the mass properties of the knee and foot components were not sensitive for the hip abduction torque. In addition, optimized prosthetic mass and appropriate mass distributions were needed to promote efficiency of rehabilitation therapy with consideration of musculoskeletal systems of amputees.