• Title/Summary/Keyword: M83

Search Result 3,457, Processing Time 0.046 seconds

Effect of Stocking Density on Chicken Meat Grades and PSE Incidence in Broiler House with or without Window (유창 및 무창계사의 사육 밀도에 따른 닭고기 등급 및 PSE육 출현에 미치는 영향)

  • Chae, H.S.;Kang, H.S.;Yoo, Y.M.;Jang, A.;Jeong, S.G.;Ham, J.S.;Ahn, C.N.
    • Korean Journal of Poultry Science
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • This study was performed to evaluate the effect of the level of stocking density of housing with or without window on chicken meat quality. The incidence of $1^+$ grade of whole chicken housed with window significantly influenced by stocking density. The incidence of $1^+$ grade chicken at high stocking density ($0.050\;m^2$/head), standard stocking density ($0.066\;m^2$/head), and low stocking density ($0.083\;m^2$/head) was 26, 52, and 66%, respectively. Breast muscle of chicken housed with window and with low stocking density showed higher incidence of $1^+$ grade than high stocking density. Also minor and severe PSE (pale, soft, extractive) incidence of chicken meat were showed 4% each, while the $1^+$ grade chicken was not appeared at low density. In chicken thigh, the incidence rate was not affected by stocking density. In chicken housed without window, the incidence of $1^+$ grade chicken in high, standard, and low stocking density was 18, 8, and 46%, respectively. Also, the incidence of $1^+$ grade chicken breast was 2.6 times higher than the chicken in low stocking density. However, incidence of $1^+$ grade thigh was not affected by the stocking density. These results suggest that high stocking density significantly reduced the incidence of $1^+$ grade chicken meat regardless of housing with or without window.

Comparison of characteristics of silver-grid transparent conductive electrodes for display devices according to fabrication method (제조공법에 따른 디스플레이 소자용 silver-grid 투명전극층의 특성 비교)

  • Choi, Byoung Su;Choi, Seok Hwan;Ryu, Jeong Ho;Cho, Hyun
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.2
    • /
    • pp.75-79
    • /
    • 2017
  • Honeycomb-shaped Ag-grid transparent conductive electrodes (TCEs) were fabricated using two different processes, high density plasma etching and lift-off, and the optical and electrical properties were compared according to the fabrication method. For the fabrication of the Ag-grid TCEs by plasma etching, etch characteristics of the Ag thin film in $10CF_4/5Ar$ inductively coupled plasma (ICP) discharges were studied. The Ag etch rate increased as the power increased at relatively low ICP source power or rf chuck power conditions, and then decreased at higher powers due to either decrease in $Ar^+$ ion energy or $Ar^+$ ion-assisted removal of the reactive F radicals. The Ag-grid TCEs fabricated by the $10CF_4/5Ar$ ICP etching process showed better grid pattern transfer efficiency without any distortion or breakage in the grid pattern and higher optical transmittance values of average 83.3 % (pixel size $30{\mu}m/line$ width $5{\mu}m$) and 71 % (pixel size $26{\mu}m/line$ width $8{\mu}m$) in the visible range of spectrum, respectively. On the other hand, the Ag-grid TCEs fabricated by the lift-off process showed lower sheet resistance values of $2.163{\Omega}/{\square}$ (pixel size $26{\mu}m/line$ width $18{\mu}m$) and $4.932{\Omega}/{\square}$ (pixel size $30{\mu}m/line$ width $5{\mu}m$), respectively.

Studies on Offspring Production by Transfer of Biopsied Embryo in Mice (생쥐에 있어서 단일해구(單一害球)가 분리(分離)된 수정란(受精卵)의 이식(移植)에 의한 새끼생산(生産)에 관한 연구)

  • Jeon, Ik Soo;Park, Soo Bong;Shin, Myung Jae;Choi, You Lim;Kim, Seun Eui;Choi, Kwang Soo
    • Current Research on Agriculture and Life Sciences
    • /
    • v.9
    • /
    • pp.29-36
    • /
    • 1991
  • The study was carried out to investigate the viability and the offspring production rate of single blastomeres and biopsied 4-cell mouse embryos and, also to examine the efficiency of biopsy. The results obtained are summerised as follows: 1. The separated blastomeres from 4-cell embryos and intact 4-cell embryos which were cultured in Medium 2 were developed to trophoblastic vesicle and blastocyst embryo by 82.6% and 89.5%. respectively. 2. The biopsied embryos from 4-cell embryos and intact 4-cell embryos which were cultured in Medium 2 were developed to blastocyst embryo by 83.3% and 90.4%, respectively. 3. The biospied blastomeres and the separated blastomeres from 4-cell embryos which were cultured in Medium 2 were developed to trophoblastic vesicle by 80.8% and 83.3%, respectively. 4. The biopsied embryos from 4-cell embryos and intact 4-cell embryos were transferred to recipients, and the offspring rate was 36% and 48.6%, respectively.

  • PDF

Distributions of Hyperfine Parameters in Amorphous $Fe_{83}B_9Nb_7Cu_1$ Alloys (비정질 $Fe_{83}B_9Nb_7Cu_1$의 M$\)

  • 윤성현;김성백;김철성
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.6
    • /
    • pp.271-277
    • /
    • 1999
  • Amorphous $Fe_{83}B_9Nb_7Cu_1$ alloy has been studied by M$\"{o}$ssbauer spectroscopy. Revised Vincze method was used and distributions of hyperfine field, isomer shift, and quadrupole line broadening of the sample at various temperatures have been evaluated and Curie temperature and $H_{hf}\;(0)$ were calculated to be 393 K and 231 kOe, respectively. Temperature variation of reduced average hyperfine field shows a flattered curvein comparison with the Brillouin curve for S=1. This behavior can be explained on the basis of Handrich molecular field model, in which the parameter Δ, which is a measure of fluctuation in exchange interactions, is assumed to have the temperature dependence ${Delta}=0.75-0.64{\tau}+0.47{\tau}^2$ where $\tau$ is $T/T_C$. At low temperature, the average hyperfine field can be fitted to $H_{hf}\;(T)=H_{hf}\;(0)\;[1-0.44\;(T/T_C)^{3/2}-0.28(T/T_C)^{5/2}-… ]$, which indicates the presence long wave length spin wave excitations. At temperature near TC, reduced average hyperfine field varies as $1.00\;[1-T/T_C]^{0.39}$. It is also found that half-width of the hyperfine field distribution was 102 kOe (3.29 mm/s) at 13 K and decreased monotonically as temperature increased. Above the Curie temperature, an average quadrupole splitting value of 0.43 mm/s was found. Average line broadening due to quadrupole splitting distribution was 0.31 mm/s at 13 K and decreases monotonically to 0.23 mm/s at 320 K, whereas that due to the isomer shift distribution is 0.1 mm/s at 13 K and 0.072 mm/s at 320 K, which is much smaller than that of both hyperfine field and quadrupole splitting. The temperature dependence of the isomer shift can be fitted within the harmonic approximation to a Deybe model with a Debye temperature ${Theta}_D=424{\pm}5K$.TEX>.

  • PDF

Comparison of Thallium-201 Scan and Tc-99m Sestamibi Scan in the Differential Diagnosis of Breast Mass (유방암 진단에 있어서 탈륨스캔과 Tc-99m MIBI 스캔의 비교)

  • Cho, Ihn-Ho;Won, Kyu-Jang;Lee, Hyung-Woo;Lee, Soo-Jung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.76-83
    • /
    • 1999
  • Purpose: We performed this study to compare T1-201 and Tc-99m MIBI scans for the differentiation of malignant from benign breast mass. Materials and Methods: Thirty-eight female patients underwent T1-201 breast scan and thirty-two of them also underwent Tc-99m MIBI scan of the breast. After intravenous injection of 74-111 MBq of T1-201, early (10 minutes) and delayed (3 hours) images were obtained. Then, 555-740 MBq of Tc-99m MIBI was injected and images after 30 minutes were obtained. We compared T1-201 and Tc-99m MIBI scans with pathologic results. Results: Twenty-three patients were confirmed to have infiltrating duct carcinoma and fifteen patients to have benign breast mass by excisonal biopsy. The sensitivity of early and delayed T1-201 scan and Tc-99m MIBI scan in the detection of malignant breast lesion were 100% (23/23), 82% (18/22), and 90% (18120), respectively. The sensitivity of early T1-201 scan was significantly higher than that of delayed T1-201 scan (p<0.05). The specificity of early and delayed T1-201 scan and Tc-99m MIBI scan were 73% (l1/15), 73% (l1/15) and 83% (10/12), respectively (p: not significant). Three patients out of nine with fibroadenoma and one patient with atypical duct hyperplasia were false positive in both early and delayed T1-201 scans. The size of fibroadenoma with false positive in early and delayed T1-201 scan (4 cases) was larger than that of 11 fibroadenoma with true negative scan (p<0.01). Metastatic axillary lymph node involvement was present in fifteen patients. The sensitivity to detect metastatic nodes was 38% (5/13) for early T1-201 images, 15% (2/13) for delayed T1-201 images, 58% (7/12) for Tc-99m MIBI planar images and 67% (4/6) for Tc-99m MIBI SPECT. The sensitivity of Tc-99m MIBI planar or SPECT was significantly higher than that of delayed T1-201 images (p<0.05). Conclusion: Early T1-201 and Tc-99m MIBI scan are useful noninvasive methods to differentiate malignant from benign mass of breast Tc-99m MIBI scan was sensitive in detecting axillary lymph node metastasis in patients with breast cancer.

  • PDF