• Title/Summary/Keyword: M3 Rotary

Search Result 168, Processing Time 0.032 seconds

Forward and backward whirling of a spinning nanotube nano-rotor assuming gyroscopic effects

  • Ouakad, Hassen M.;Sedighi, Hamid M.;Al-Qahtani, Hussain M.
    • Advances in nano research
    • /
    • v.8 no.3
    • /
    • pp.245-254
    • /
    • 2020
  • This work examines the fundamental vibrational characteristics of a spinning CNT-based nano-rotor assuming a nonlocal elasticity Euler-Bernoulli beam theory. The rotary inertia, gyroscopic, and rotor mass unbalance effects are all taken into consideration in the beam model. Assuming a nonlocal theory, two coupled 6th-order partial differential equations governing the vibration of the rotating SWCNT are first derived. In order to acquire the natural frequencies and dynamic response of the nano-rotor system, the nonlinear equations of motion are numerically solved. The nano-rotor system frequency spectrum is shown to exhibit two distinct frequencies: one positive and one negative. The positive frequency is known as to represent the forward whirling mode, whereas the negative characterizes the backward mode. First, the results obtained within the framework of this numerical study are compared with few existing data (i.e., molecular dynamics) and showed an overall acceptable agreement. Then, a thorough and detailed parametric study is carried out to study the effect of several parameters on the nano-rotor frequencies such as: the nanotube radius, the input angular velocity and the small scale parameters. It is shown that the vibration characteristics of a spinning SWCNT are significantly influenced when these parameters are changed.

High-Speed Monitoring Device to Inspect Inkjet Droplets with a Rotating Mirror and Its Measuring Method for Display Applications (잉크젯을 이용한 디스플레이 생산을 위한 회전 미러 방식의 잉크젯 액적 모니터링 장비 및 측정법 연구)

  • Shin, Dong-Youn
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.6
    • /
    • pp.525-532
    • /
    • 2017
  • The development of an inkjet-based manufacturing machine for the production of next-generation displays using organic and quantum-dot light emitting diodes at a low cost has been conducted. To employ inkjet printing in production lines of displays, the development of a high-speed inkjet-monitoring device to verify the reliable droplet jetting status from multiple nozzles is required. In this study, an inkjet monitoring device using a rotatable mirror with rotary and linear ultrasonic motors is developed in place of a conventional, linear reciprocating, motion-based inkjet monitoring device. Its performance is also demonstrated. The measurements of circular patterns with diameters of $10{\mu}m$, $30{\mu}m$, and $50{\mu}m$ are performed with the accuracies of $0.5{\pm}1.0{\mu}m$, $-1.2{\pm}0.3{\mu}m$, and $0.2{\pm}0.5{\mu}m$, respectively, within 17 sec. By optimizing the control program, the takt time can be reduced to as short as 8.6 sec.

Dentinal defects induced by 6 different endodontic files when used for oval root canals: an in vitro comparative study

  • Pawar, Ajinkya M;Thakur, Bhagyashree;Kfir, Anda;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.31.1-31.9
    • /
    • 2019
  • Objectives: To compare the formation of dentinal defects using stainless-steel hand K-files (HFs), rotary files, reciprocating files, and Self-Adjusting File (SAF), when used for oval root canals. Materials and Methods: One hundred and forty extracted human mandibular premolar with single root and oval canal were selected for this study. Oval canals were confirmed by exposing to mesio-distal and bucco-lingual radiographs. Teeth with open apices or anatomic irregularities were excluded. All selected teeth were de-coronated perpendicular to the long axis of the tooth, leaving roots segments approximately of 16 mm in length. Twenty teeth were left unprepared (control), and the remaining 120 teeth were divided into 6 groups (n = 20) and instrumented using HF (size 40/0.02), Revo-S (RS; size 40/0.06), ProTaper NEXT (PTN; size 40/0.06), WaveOne (WO; size 40/0.09), RECIPROC (RC; size 40/0.06), and the SAF (2 mm). Roots were then sectioned 3, 6, and 9 mm from the apex, and observed under stereomicroscope, for presence of dentinal defects. "No defect" was defined as root dentin that presented with no visible microcracks or fractures. "Defect" was defined by microcracks or fractures in the root dentin. Results: The control, HF, and SAF did not exhibit any dentinal defects. In roots instrumented by RS, PTN, WO, and RC files exhibited microcracks (incomplete or complete) in 40%, 30%, 55%, and 50%, respectively. Conclusions: The motor-driven root canal instrumentation with rotary and reciprocating files may create microcracks in radicular dentine, whereas the stainless-steel hand file instrumentation, and the SAF produce minimal or less cracks.

Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic files

  • Charlotte Gouedard;Laurent Pino;Reza Arbab-Chirani;Shabnam Arbab-Chirani;Valerie Chevalier
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.2
    • /
    • pp.16.1-16.9
    • /
    • 2022
  • Objectives: This study compared the cyclic fatigue resistance of One Curve (C wire) and F6 Skytaper (conventional austenite nickel-titanium [NiTi]), and 2 instruments with thermos-mechanically treated NiTi: Protaper Next X2 (M wire) and Hyflex CM (CM wire). Materials and Methods: Ten new instruments of each group (size: 0.25 mm, 6% taper in the 3 mm tip region) were tested using a rotary bending machine with a 60° curvature angle and a 5 mm curvature radius, at room temperature. The number of cycles until fracture was recorded. The length of the fractured instruments was measured. The fracture surface of each fragment was examined with a scanning electron microscope (SEM). The data were analyzed using one-way analysis of variance and the post hoc Tukey test. The significance level was set at 0.05. Results: At 60°, One Curve, F6 Skytaper and Hyflex CM had significantly longer fatigue lives than Protaper Next X2 (p < 0.05). No statistically significant differences were found in the cyclic fatigue lives of One Curve, F6 Skytaper, and Hyflex CM (p > 0.05). SEM images of the fracture surfaces of the different instruments showed typical features of fatigue failure. Conclusions: Within the conditions of this study, at 60° and with a 5 mm curvature radius, the cyclic fatigue life of One Curve was not significantly different from those of F6 Skytaper and Hyflex CM. The cyclic fatigue lives of these 3 instruments were statistically significantly longer than that of Protaper Next.

A study on the precision measurement of spatially coordination of the industrial manipulator using the R-LAT Sensor (R-LAT Sensor를 이용한 산업용 매니퓰레이터 공간좌표 정밀계측에 관한 연구)

  • Kim, Tae-Hwa;Moon, Sung-Ho;Hong, Jeng-Pyo;Won, Tae-Hyun;Kwon, Soon-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1782-1783
    • /
    • 2011
  • 실내공간상에서 3차원 실시간 위치를 결정하는 다양한 측지기법들이 존재하지만 $100{\mu}m$ 이하 계측기 수준의 정밀도를 측정하는 방법은 여전히 Laser Theodolite 신호를 사용할 수밖에 없다. Rotary-Laser Automatic Theodolite(R-LAT)는 Fan Laser Beam을 주사하면서 회전시킨 후 주어진 공간의 수직과 수평을 계측하는 Laser Transmitter의 한 종류이다. 본 논문에서는 R-LAT에서 발생되는 Fan Laser Beam 신호를 취득할 수 있는 센서와 증폭회로의 개발을 통하여 3차원 공간좌표에 대한 회전변환행렬로 이루어진 알고리즘을 제안하고 실험을 통하여 기존 Laser Tracker에서 구해지는 공간좌표와 상호 비교하였다.

  • PDF

A spectrally formulated finite element method for vibration of a tubular structure

  • Horr, A.M.;Schmidt, L.C.
    • Structural Engineering and Mechanics
    • /
    • v.4 no.3
    • /
    • pp.209-226
    • /
    • 1996
  • One of the major divisions in the mathematical modelling of a tubular structure is to include the effect of the transverse shear stress and rotary inertia in vibration of members. During the past three decades, problems of vibration of tubular structures have been considered by some authors, and special attention has been devoted to the Timoshenko theory. There have been considerable efforts, also, to apply the method of spectral analysis to vibration of a structure with rectangular section beams. The purpose of this paper is to compare the results of the spectrally formulated finite element analyses for the Timoshenko theory with those derived from the conventional finite element method for a tubular structure. The spectrally formulated finite element starts at the same starting point as the conventional finite element formulation. However, it works in the frequency domain. Using a computer program, the proposed formulation has been extended to derive the dynamic response of a tubular structure under an impact load.

Advanced New Process Development of Two-Stage Swirl Calciner

  • Suh, Hyung-Suhk;Park, Choon-Keun;Ryu, Jae-Sang;Kwak, Hong-Bae
    • The Korean Journal of Ceramics
    • /
    • v.5 no.3
    • /
    • pp.296-302
    • /
    • 1999
  • The state of the art of the 2-stage swirl calciner is to make 2-stage counter gas flow in a calciner with cooler hot air. Gas flow in the calciner increases retention time of raw mix particles. Simple structure of the 2-stage swirl calciner operated optimally the rotary cement kiln. In this study, in order to decide the entrance type of the cooler air of the optimal calciner model, an entrance cooler air velocity, the input points of raw mix were analyzed in many aspects with cold model experiment and computational fluidized dynamic simulation. It was found that the entrance type of cooler air fully splite 2-stage for the optimal condition of the cold model calciner. The operation conditions were that the input feeding, the cooler air velocity and the air velocity of throat were 0.33kg/$\textrm m$3$, 15m/s and 20m/s respectively. The performance of 150 t/d the pilot plant connected with the kiln rising duct was that volume capacity of the calciner is over 430 kg/$\textrm m$3$-h, decarbonation rate of raw mix apparently 90%, heat consumption 950 kcal/kg-cli and retention time of raw mix 2.4 sec. Its the best operating condition is cooler air velocity 18m/s, the gas velocity of throat 25m/s, feeding rate of raw mix 10t/h. The operating experience of the pilot plant confirmed the success of scale up for over 3000 t-cli/d.

  • PDF

Step by Step Analysis of Root Canal Instrumentation with ProTaper® (ProTaper를 이용한 근관 형성의 단계별 분석)

  • Kim, Mi-Hee;Huh, Bock;Kim, Hyeon-Cheol;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.50-57
    • /
    • 2006
  • The purpose of this study was to investigate influence of each file step of $ProTaper^{(R)}$ system on canal transportation. Twenty simulated canals were prepared with either engine-driven $ProTaper^{(R)}$ or manual $ProTaper^{(R)}$, Group R-resin blocks were instrumented with rotary $ProTaper^{(R)}$ and group M-resin blocks were instrumented with manual $ProTaper^{(R)}$. Pre-operative resin blocks and post-operative resin blocks after each file step preparation were scanned. Original canal image and the image after using each file step were superimposed for calculation of centering ratio The image after using each file step alld image after using previous file step were superimposed for calculation of the amount of deviation. Measurements were taken horizontally at five different levels (1 2, 3, 4 and 5 mm) from the level of apical foramen. In rotary $ProTaper^{(R)}$ instrumentation group, centering ratio and the amount of deviation of each step at all levels were not significantly different (p>0.05). In manual $ProTaper^{(R)}$ instrumentation group, centering ratio and the amount of deviation of each step at all levels except of 1 mm were not significantly different (p>0.05). At the level of 1 mn, F2 file step had significantly large centering ratio and the amount of deviation (p<0.05). Under the condition of this study, F2 file step of manual ProTaper tended to transport the apical part of the canals than that of rotary $ProTaper^{(R)}$.

HTS high gradient magnetic separator prototype

  • Diev, D.N.;Lepehin, V.M.;Makarenko, M.N.;Polyakov, A.V.;Shcherbakov, V.I.;Shutova, D.I.;Surin, M.I.;Tagunov, E. Ya.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.1-5
    • /
    • 2018
  • A high gradient magnetic (HGM) separator prototype with the $2^{nd}$ generation high temperature superconducting (2G HTS) magnetic system operated in sub-cooled nitrogen is presently under development at NRC "Kurchatov Institute" (Moscow, Russia). The main goal of the project is an attempt to shift away from the complicated liquid helium cryostats towards simple cryocooler-based nitrogen cryogenics as much more convenient for HGM separators industrial applications. Using of commercial HTS tapes allows to get a sufficient level of magnetic fields and extraction forces with low energy consumption. The expected operational parameters of the device are 1.2-1.5 T in the empty operational gap and up to 3 T on the ferromagnetic filters. In this paper we briefly describe the design of the HTS rotary separator prototype with the horizontally oriented rotor axis and propose different types of ferromagnetic filters intended for weakly magnetic ores enrichment.

Effects of Carthamus Tinctorius Extract on Adipogenic Differentiation of Mouse Bone Marrow-Derived Mesenchymal Stromal Stem Cells (홍화 추출물이 생쥐 골수 유래 중간엽 줄기세포의 지방분화에 미치는 영향)

  • Yu, Sung-ryul;Shin, Seon-mi
    • The Journal of Internal Korean Medicine
    • /
    • v.38 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • Objective: This study investigated the effect of purified Carthamus tinctorius (C. tinctorius) extracted with a hot water and ethanol method on adipogenic differentiation of mouse bone marrow-derived mesenchymal stromal stem cells (mBMSCs). Methods: The C. tinctorius was extracted using hot water and ethanol. The samples were concentrated by a rotary evaporator and were then dried using a freeze-dryer. The mBMSCs were cultured and maintained in a minimum essential medium eagle alpha (${\alpha}-MEM$) supplemented with 10% FBS and 1% antibiotic antimycotic solution. To induce adipogenic differentiation, the cells were treated with Dulbecco's modified eagle's medium-low glucose (DMEM-LG) containing 1 mg/mL insulin, 1 mM dexamethasone, and 0.5 mM 3-isobutyl-1-methylxanthine. To evaluate the adipogenic differentiation ability, oil-red O staining was performed after adipogenic differentiation for 21 days. The mRNA expression and protein level of adipogenic-related genes were quantified by quantitative real-time PCR and western blotting, respectively. Results: In the results of the MTT assay, no concentrations of C. tinctorius extracts showed toxicity on mBMSCs, so we fixed the treatment concentration of the extract at 100 ng/mL. In oil-red O staining, the water-C. tinctorius extract treatment significantly decreased adipogenic differentiation compared with the control and ethanol extract groups. The water-C. tinctorius extract group in particular showed reduced mRNA and protein expression of Peroxisome proliferator-activated receptor gamma ($Ppar{\gamma}$) and CCAAT/enhancer-binding protein alpha ($C/ebp{\alpha}$), which are adipogenic-related transcription factors. Conclusion: These data suggest that extract of C. tinctorius decreased the adipogenic differentiation of mBMSCs, while only water-C. tinctorius extract had an effect on different adipogenesis in mBMSCs. The C. tinctorius will be a useful therapeutic reagent for the prevention of obesity-related diseases such as diabetes, hyperlipidemia, coronary artery disease, and osteoporosis.