• Title/Summary/Keyword: M2M platform

Search Result 432, Processing Time 0.034 seconds

Extending the OPRCB Seismic isolation system's governing equations of motion to 3D state and its application in multi-story buildings

  • M. Hosseini;S. Azhari;R. Shafie Panah
    • Earthquakes and Structures
    • /
    • v.24 no.3
    • /
    • pp.217-235
    • /
    • 2023
  • Orthogonal pairs of rollers on concave beds (OPRCB) are a low-cost, low-tech rolling-based isolating system, whose high efficiency has been shown in a previous study. However, seismic performance of OPRCB isolators has only been studied in the two-dimensional (2D) state so far. This is while their performance in the three-dimensional (3D) state differs from that of the 2D state, mainly since the vertical accelerations due to rollers' motion in their beds, simultaneously in two orthogonal horizontal directions, are added up and resulting in bigger vertical inertia forces and higher rolling resistance. In this study, first, Lagrange equations were used to derive the governing equations of motion of the OPRCB-isolated buildings in 3D. Then, some regular shear-type OPRCB-isolated buildings were considered subjected to three-component excitations of far- and near-source earthquakes, and their responses were compared to those of their fixed-base counterparts. Finally, the effects of more realistic modeling and analysis were examined by comparing the responses of isolated buildings in 2D and 3D states. Response histories were obtained by the fourth-order Runge-Kutta-Nystrom method, considering the geometrical nonlinearity of isolators. Results reveal that utilizing the OPRCB isolators effectively reduces the acceleration response, however, depending on the system specifications and earthquake characteristics, the maximum responses of isolated buildings in the 3D state can be up to 40% higher than those in the 2D state.

Estimation of spatiotemporal soil moisture distribution for Yongdam-dam watershed using Sentinel-1 C-band Synthetic Aperture Radar images (Sentinel-1 C-band SAR 영상을 이용한 용담댐 유역의 시공간 토양수분 산정)

  • Chung, Jeehun;Lee, Yonggwan;Jang, Wonjin;Kim, Seongjoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.162-162
    • /
    • 2020
  • 토양수분은 TDR(Time Domain Reflectometry)이나 Tensiometer 등의 장비를 이용하여 측정을 시행하고 있으나, 이를 위해서는 많은 인력과 경제적 자원이 소비될 뿐만 아니라 시공간적으로 측정할 수 있는 범위에 한계가 있다. 지상 관측의 대안으로 MIRAS(Microwave Imaging Radiometer with Aperture Synthesis)나 SMAP(Soil Moisture Active Passive), AMSR2(Advanced Microwave Scanning Radiometer 2) 등의 수동 마이크로파 위성 센서를 이용한 공간 토양수분 관측이 수행되었으나, 낮은 공간 해상도(9~36km)는 지역 규모의 토양수분 분포를 나타내기 충분하지 않고, 높은 불확실성을 내포하고 있다. 본 연구에서는 금강 상류의 용담댐 유역(930.0㎢)을 대상으로 Sentinel-1 C-band SAR(Synthetic Aperture Radar) 영상을 이용한 토지 피복 및 토양 속성을 고려한 10m 해상도의 토양수분 산출을 수행하였다. 용담댐 유역은 산림 79.7%, 논 9.0%, 밭 5.4%, 주거지 2.9%의 토지 피복 비율을 가지며 토양은 사양토(66.6%)와 양토(20.9%)가 우세하다. Sentinel-1 C-band SAR 영상은 SeNtinel Application Platform(SNAP)을 이용하여 전처리 후, 후방산란계수로 변환하였다. 토양수분 알고리즘은 TU-Wien change detection algorithm과 Regression model을 활용하였고, 검증을 위한 실측 토양수분 자료는 한국수자원공사(K-water)에서 제공하는 5년(2014~2018)간의 토양수분 관측자료를 이용하였다. 산출된 토양수분은 결정계수(Coefficient of determination, R2) 및 평균제곱근오차(Root Mean Square Error, RMSE)를 이용하여 실측 토양수분과 비교하였다. Sentinel-1 C-band SAR 영상을 이용한 고해상도의 토양수분 산출은 토지 피복 및 토양 속성을 고려한 지역 규모의 공간 토양수분 분포 및 시간적 변화를 표현 가능할 것으로 판단된다.

  • PDF

Study on free and bond glycerines in Biodiesel from PKO(Palm Kernel Oil) and coconut oil (PKO 및 코코넛유래 바이오디젤 중 글리세린함량 분석 방법 개선 연구)

  • Lee, Don-Min;Park, Chun-Kyu;Ha, Jong-Han;Lee, Bong-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.348-361
    • /
    • 2015
  • To reduce the effects of greenhouse gas (GHG) emissions, the government has announced the special platform of technologies as parts of an effort to minimize global climate change, and the government distributed biodiesel since 2006 as the further efforts. Although there are some debates about some quality specifications and unbalanced of source (44% from palm oil), more than 400kton/year of biodiesel was produced in 2013. Moreover the amounts will be increased when the RFS is activated. To solve the unbalanced situation and to achieve the diversity of feeds, it is essential that many researches should be considered. Especially, free and bond glycerines are one of the important properties seriously affected to the combustion system in vehicle & cold properties. Previous method (KS M 2412) couldn't cover the biodiesel derived from lauric oil($C_{12:0}$) such as PKO (Palm Kernel Oil), Coconut oil because those compositions are lighter than other conventional biodiesel sources. In this study, we review the existed method and figure out the factors should improve to analysis the glycerine from PKO and Coconut oil biodiesel. Modifying the analysis conditions to enhance the resolution and change the internal standards to avoid the overlapped- peaks between Capric acid ME ($C_{10:0}$) and standard#1(1,2,4-butantriol). From this revised method, we could solve the restrictions of previous methods. And check the possibility of new method to analyze the glycerine in biodiesel regardless of sources.

Full mouth prosthodontic reconstruction on patient with occlusion collapse & decreased vertical dimension (교합 붕괴 환자의 수직고경거상을 동반한 완전 구강회복 증례)

  • Yoo, H.J.;Choi, M.H.;Kim, C.H.;Park, Y.R.;Kang, D.W.
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.115-124
    • /
    • 2003
  • One of the important things in the full mouth reconstruction is the determination of therapeutic position. Centric jaw relation is used as a therapeutic position for the full mouth reconstruction. There are several techniques associated with recording this position. Five clinically acceptable techniques are as follows: 1) Swallowing or free closure, 2) Chin point guidance, 3) Bimanual method 4) Myo-monitor technique, 5) Anterior deprogrammer. Centric relation obtained utilizing the anterior acrylic resin platform in this case. Another important thing in full mouth reconstruction is provisional restoration. Provisional restorations are an excellent diagnostic instrument, especially in full remain esthetics, phonetics, function, parafunction, and dysfunction after evaluation and acceptance through clinical trial with the provisional restorations should be accurately transferred to the final restorations to ensure the same clinical success. Especially, anterior guidance should be accurately transferred to the final restorations. An accurate anterior guidance is critical for optimal esthetics, phonetics, comfort, function, stress minimization, and longevity of teeth and restorations. To record optimum anterior guidance, customized anterior guide table is used in this case. Considering previously mentioned points, we did successive treatment. And it resulted in a better situation esthetically and functionally. Followings are what we cared in treating a patient in this case. 1) Accurate centric relation recording 2) Accurate transference of anterior guidance to the final restorations.

Nano SPR Biosensor for Detecting Lung Cancer-Specific Biomarker (폐암 바이오마커 검출용 나노SPR 바이오센서)

  • Jang, Eun-Yoon;Yeom, Se-Hyuk;Eum, Nyeon-Sik;Han, Jung-Hyun;Kim, Hyung-Kyung;Shin, Yong-Beom;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.144-149
    • /
    • 2013
  • In this research, we developed a biosensor to detect lung cancer-specific biomarker using Anodic Aluminum Oxide (AAO) chip based on interference and nano surface plasmon resonance (nanoSPR). The nano-porous AAO chip was fabricated $2{\mu}m$ of pore-depth by two-step anodizing method for surface uniformity. NanoSPR has sensitivity to the refractive index (RI) of the surrounding medium and also provides simple and label-free detection when specific antibodies are immobilized to the Au-deposited surface of nano-porous AAO chip. To detect the lung cancer-specific biomarker, antibodies were immobilized on the surface of the chip by Self Assembled Monolayer (SAM) method. Since then lung cancer-specific biomarker was applied atop the antibodies immobilized layer. The specific reaction of the antigen-antibody contributed to the change in the refractive index that cause shift of resonance spectrum in the interference pattern. The Limit of Detection (LOD) was 1 fg/ml by using our nano-porous AAO biosensor chip.

Development of Outdoor Geological Field Course for Elementary School Using Local Geology - Centers on the Odongdo- (지역 지질을 활용한 초등학교 야외지질학습장의 개발 - 오동도를 중심으로 -)

  • Kim, Hai-Gyoung
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.8 no.2
    • /
    • pp.128-138
    • /
    • 2015
  • The purpose of this study is to examine potential as a geological field course of Odongdo located to the east of Yeosu city, Korea. The total area and the height from the sea level of Odongdo is about 0.13km2 and 42m, respectively. Odongdo area belongs to the Hallyeohaesang National Marine Park, and is famous for rock scenery in the rocky coast and living of rare plants. For this study, diversity of geomorphology and geology was investigated at the sites called as dragon cave, windy area, seal rocks, sunrise viewing platform, second seashore rocks and first seashore rocks along the coast of Odongdo. The results of this study are as follows: A lot of geomorphological and geological resources like sea cliff, sea cave, strata, various sedimentary rocks(conglomerate, sandstone, mudstone), andesite, fault and examples of rock weathering were found in the rocky coast of the study area. These field resources are pertinent to the field work materials for the teaching and learning of geology units in elementary school science. Odongdo is to be recommended as a site of outdoor geological field course for the elementary school students inhabited in Yeosu city and neighborhood area because each site of the rocky coast in this study area has various field work materials and the wide space for observe activities, and is equipped with the facilities as a trail for rock observation.

Volumetric analysis of mucous retention cysts in the maxillary sinus: A retrospective study using cone-beam computed tomography

  • Hung, Kuofeng;Hui, Liuling;Yeung, Andy Wai Kan;Wu, Yiqun;Hsung, Richard Tai-Chiu;Bornstein, Michael M.
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.117-127
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate the volumetric characteristics of mucous retention cysts(MRCs) in the maxillary sinus and to analyze potential associations of MRCs with dentoalveolar pathologies. Materials and Methods: Cone-beam computed tomography (CBCT) scans exhibiting bilateral maxillary sinuses that were acquired from January 2016 to February 2019 were initially screened. A total of 227 scans(454 sinuses) that fulfilled the inclusion criteria were included. The presence, location, and volumetric characteristics of the diagnosed MRCs were evaluated on CBCT images using the 3D-Slicer software platform. The presence of MRCs was correlated with potential influencing factors including age, sex, and dentoalveolar pathology. For MRCs located on the sinus floor, factors with a potential impact on the volume, surface, and diameter were analyzed. Results: An MRC was present in 130 (28.6%) of the 454 sinuses. Most MRCs were located on the sinus walls and floor. The mean MRC volume, surface, and diameter were 551.21±1368.04 mm3, 228.09±437.56 mm2, and 9.63±5.40 mm, respectively. Significantly more sinuses with associated endodontically treated teeth/periapical lesions were diagnosed with an MRC located on the sinus floor. For MRCs located on the sinus floor, endodontic status exhibited a significant association with increased volume, surface, and diameter. Conclusion: Periapical lesions might be a contributing factor associated with the presence and volume of MRCs located on the sinus floor. The 3D-Slicer software platform was found to be a useful tool for clinicians to analyze the size of MRCs before surgical interventions such as sinus floor elevation procedures.

A Study on Gathering Behaviour of Fish in the Artificial Sea-floor Area (인공해저에 대한 어류의 위집기구에 관한 연구)

  • 홍성완
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.2
    • /
    • pp.96-104
    • /
    • 2000
  • By using the offshore type submersible platform, Artificial sea floor anchored at a depth of forty meters several experimental studies have been conducted successfully during 1996. The facility consists of an artificial sea floor that floats at 7 meters below the surface, a machinery hut that projects above the surface at the center of the structure and a balance weight beneath the structure. The facility can be surfaced easily by using a water discharging pump in the water tank which is located at the center of it. To find out the behavioral character and the gathering factor of fishes around the artificial sea floor, investigations were carried out during the daytime and nighttime by direct observation and by echo-sounder. Around the testing reefs and artificial sea floor, six kinds of fishes were found by diving observation and the dominants were Scomber japonicus, Sebastes thompsoni and Oplegnathus fascitus. As Scomber japonicus was distributed around the artificial sea floor in dense small school, they were not seen elsewhere in the survey area. The artificial sea floor was concluded to act as a schooling ground far Scomber japonicus, Sebastes thompsoni and Oplegnathus fascitus. were close to the testing reefs(within 10m) in the daytime, and were thought to settle on the testing reefs at nighttime, To examine the distribution of 7shes around the artificial sea floor, an acoustic survey over a 1$\times$1km area, 0-50m in depth during the all day. Around the artificial sea floor many thin scattering fish echo(TS-54.5~ -51.5dB) and dense fish echo(TS-41~-38dB) were mainly distributed. Many scattering fish echoes, which were thought to be a mixture of small squid, pelegic crustacea and ethers, were distributed over the whole survey area. A dense fish school stayed beneath the artificial sea floor for a short duration. These phenomena were concluded to show an attraction and detention function of the artificial sea floor.

  • PDF

Three-dimensional finite element analysis according to the insertion depth of an immediately loaded implant in the anterior maxilla (상악 전치부 즉시하중 임플란트의 식립 깊이에 따른 삼차원 유한요소 분석)

  • Park, Cheol-Woo;Kim, Sung-Hun;Yeo, In-Sung;Yoon, Hyung-In;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.105-113
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effects of the insertion depth of an immediately loaded implant on the stress distribution of the surrounding bone and the micromovement of the implant using the three-dimensional finite element analysis. Materials and methods: A total of five bone models were constructed such that the implant platform was positioned at the levels of 0.00 mm, 0.25 mm, 0.50 mm, 0.75 mm, and 1.00 mm depth from the crest of the cortical bone. A frictional coefficient of 0.3 and the insertion torque of 35 Ncm were simulated on the interface between the implant and surrounding bone. A static load of 178 N was applied to the provisional prosthesis with a vertical load in the axial direction and an oblique load at $30^{\circ}$ with respect to the central axis of the implant, then a finite element analysis was performed. Results: The implant insertion depth significantly affected the stress distribution on the surrounding bone. The largest micromovement value of the implant was $39.34{\mu}m$. The oblique load contributed significantly to the stress distribution and micromovement in comparison to the vertical load. Conclusion: Increasing the implant insertion depth was advantageous in dispersing the concentrated stress in the cortical bone and did not significantly affect the micromovement associated with early osseointegration failure.

Analysis of a CubeSat Magnetic Cleanliness for the Space Science Mission (우주과학임무를 위한 큐브위성 자기장 청결도 분석)

  • Jo, Hye Jeong;Jin, Ho;Park, Hyeonhu;Kim, Khan-Hyuk;Jang, Yunho;Jo, Woohyun
    • Journal of Space Technology and Applications
    • /
    • v.2 no.1
    • /
    • pp.41-51
    • /
    • 2022
  • CubeSat is a satellite platform that is widely used not only for earth observation but also for space exploration. CubeSat is also used in magnetic field investigation missions to observe space physics phenomena with various shape configurations of magnetometer instrument unit. In case of magnetic field measurement, the magnetometer instrument should be far away from the satellite body to minimize the magnetic disturbances from satellites. But the accommodation setting of the magnetometer instrument is limited due to the volume constraint of small satellites like a CubeSat. In this paper, we investigated that the magnetic field interference generated by the cube satellite was analyzed how much it can affect the reliability of magnetic field measurement. For this analysis, we used a reaction wheel and Torque rods which have relatively high-power consumption as major noise sources. The magnetic dipole moment of these parts was derived by the data sheet of the manufacturer. We have been confirmed that the effect of the residual moment of the magnetic torque located in the middle of the 3U cube satellite can reach 36,000 nT from the outermost end of the body of the CubeSat in a space without an external magnetic field. In the case of accurate magnetic field measurements of less than 1 nT, we found that the magnetometer should be at least 0.6 m away from the CubeSat body. We expect that this analysis method will be an important role of a magnetic cleanliness analysis when designing a CubeSat to carry out a magnetic field measurement.