• Title/Summary/Keyword: M2M Model

Search Result 7,888, Processing Time 0.036 seconds

Behavior of tunnel under the influence of pre-loading on braced wall during the adjacent ground excavation (근접굴착 시 벽체에 선행하중 재하에 따른 터널의 거동)

  • Kim, Il;Lee, Sang-Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.4
    • /
    • pp.331-341
    • /
    • 2007
  • Pre-loads could be imposed on the braced wall to prevent the horizontal displacements during the ground excavation adjacent to the existing tunnel. For this purpose, new pre-loading system through which large pre-loads could be applied to the braced wall was used in the model tests. Large scale model tests were performed in the real scale test pit which was 2.0 m in width and 6.0 m in hight and 4.0 m in length. Test ground was constructed by sand. Model tunnel in 1.2 m diameter was constructed before test ground excavation. Test ground was excavated adjacent to existing tunnel and was braced. To investigate the effect of pre-loading, tests without pre-load were also performed. During the ground excavation were the behavior of braced wall, test tunnel, and ground measured. Model tests were also numerically analysed and their results were compared to that of the real scale tests. As a result, it was found that the stability of the existing tunnel was greatly enhanced when the horizontal displacements of braced wall was reduced by applying pre-load larger than the design load.

  • PDF

A Performance Analysis Model of PC-based Software Router Supporting IPv6-IPv4 Translation for Residential Gateway

  • Seo, Ssang-Hee;Kong, In-Yeup
    • Journal of Information Processing Systems
    • /
    • v.1 no.1 s.1
    • /
    • pp.62-69
    • /
    • 2005
  • This paper presents a queuing analysis model of a PC-based software router supporting IPv6-IPv4 translation for residential gateway. The proposed models are M/G/1/K or MMPP-2/G/1/K by arrival process of the software PC router. M/G/1/K is a model of normal traffic and MMPP-2/G/1/K is a model of burst traffic. In M/G/1/K, the arriving process is assumed to be a Poisson process, which is independent and identically distributed. In MMPP-2/G/1/K, the arriving process is assumed to be two-state Markov Modulated Poisson Process (MMPP) which is changed from one state to another state with intensity. The service time distribution is general distribution and the service discipline of the server is processor sharing. Also, the total number of packets that can be processed at one time is limited to K. We obtain performance metrics of PC-based software router for residential gateway such as system sojourn time blocking probability and throughput based on the proposed model. Compared to other models, our model is simpler and it is easier to estimate model parameters. Validation results show that the model estimates the performance of the target system.

Analysis of electrical characteristics for p-type silicon germanium metal-oxide semiconductor field-effect transistors (SiGe pMOSFET의 전기적 특성 분석)

  • Ko Suk-woong;Jung Hak-kee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.2
    • /
    • pp.303-307
    • /
    • 2006
  • In this paper, we have designed the p-type metal-oxide semiconductor field-effect transistor(pMOSFET) for SiGe devices with gate lengths of $0.9{\mu}m$ and $0.1{\mu}m$using the TCAD simulators. The electrical characteristics of devices have been investigated over the temperatures of 300 and 77K. We have used the two carrier transfer models(hydrodynamic model and drift-diffusion model). We how that the drain current is higher in the hydrodynamic model than the drift-diffusion model. When the gate length is $0.9{\mu}m$, the threshold voltage shows -0.97V and -1.15V for 300K and 77K, respectively. The threshold voltage is, however, nearly same at $0.1{\mu}m$ for 300K and 77K.

A Study on Pseudo-Range Correction Modeling in order to Improve DGNSS Accuracy (DGNSS 위치정확도 향상을 위한 PRC 보정정보 모델링에 관한 연구)

  • Sohn, Dong Hyo;Park, Kwan Dong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.4
    • /
    • pp.43-48
    • /
    • 2015
  • We studied on pseudo-range correction(PRC) modeling in order to improve differential GNSS(DGNSS) accuracy. The PRC is the range correction information that provides improved location accuracy using DGNSS technique. The digital correction signal is typically broadcast over ground-based transmitters. Sometimes the degradation of the positioning accuracy caused by the loss of PRC signals, radio interference, etc. To prevent the degradation, in this paper, we have designed a PRC model through polynomial curve fitting and evaluated this model. We compared two quantities, estimations of PRC using model parameters and observations from the reference station. In the case of GPS, the average is 0.1m and RMSE is 1.3m. Most of GPS satellites have a bias error of less than ${\pm}1.0m$ and a RMSE within 3.0m. In the case of GLONASS, the average and the RMSE are 0.2m and 2.6m, respectively. Most of satellites have less than ${\pm}2.0m$ for a bias error and less than 3.0m for RMSE. These results show that the estimated value calculated by the model can be used effectively to maintain the accuracy of the user's location. However;it is needed for further work relating to the big difference between the two values at low elevation.

A study on the Plan Modular Establishment for the Development of Wooden Dwelling Model - Focused on the Post & Beam Structure - (목조주택 모형개발을 위한 평면모듈 설정에 대한 연구 - 기둥-보 방식 구조를 중심으로 -)

  • Kang, Man-Ho;Joo, Seok-Joong;Kim, Jae-Deok
    • Journal of the Korean housing association
    • /
    • v.18 no.1
    • /
    • pp.141-148
    • /
    • 2007
  • In this research, to develope wooden house model with post & beam structure which is commensurate with domestic environment, we analyzed the size and module of a unit space and space organization of existing habitation, then, based on the result, we tried to suggest general wood house modules. For this, we investigated 98 floor plans for 30 pyeong apartment in Seoul, Gyounggi-do, Gwangju, and Jeolla-do. The results are showed as follows. 1) It has shown that 7 posts distances are available in 2 bay floor plan type - 3.0 m, 3.3 m, 3.6 m, 3.9 m, 4.2 m, 4.5 m, and 4.8 m. 2) It has shown that 8 posts distances are available in 3 bay floor plan type - 3.0 m, 3.3 m, 3.6 m, 3.9 m, 4.2 m, 4.5 m, 4.8 m, and 5.1 m. It was concluded as follows, applying the standard of regulations of horizontal modular coordination design, from $\ulcorner$the standard of modular coordination design in architecture(KSF 1525)$\lrcorner$. 1) The available widths are 3.0 m, 3.3 m, 3.6 m, 4.2 m, and 4.8 m, and the available depths are 3.0 m, 3.3 m, 3.6 m, and 4.2 m. 2) To guarantee a space through post module of a room combination, we can use a module of 3.6 m, 4.2 m, 4.8 m except 3.0 m, 3.3 m among available modules. The module investigated in post & beam structure wooden house is applied in basic 6 floor plans as follows. 1) When organize the room on the basis of tile module of 3.6 m, 4.2 m, it was possible to organize the floor plan. 2) After arranging main room, making practical application of variableness which is advantage of post & beam structure, putting to practical use of extra space that becomes the combination of atypical room such as kitchen, dining room, and bathroom, it was possible to organize the floor plan of the residence. 3) It is possible to organize whole rooms through the plan module from 3.6 m to 4.2 m, that decides the floor plan of a wooden house.

Adaption and Assessment of ETSI M2M Standard in Smart Home Environments (ETSI M2M 표준의 스마트 홈 적용 및 적합성 평가)

  • Park, Yunjung;Wu, Hyuk;Paek, Hyung-Goo;Min, Dugki
    • Journal of Information Technology Services
    • /
    • v.11 no.3
    • /
    • pp.241-255
    • /
    • 2012
  • Recently, smart home environments which provide complex services through smart appliances are becoming realized, due to the advances in connected devices and network technologies. Current smart home environments are mostly restricted, because of difficultly of integration of heterogeneous smart appliances. Therefore radical service integration is impracticable. In this paper, we analyze and implement Machine-to-Machine (M2M) standards which are established by European Telecommunications Standards Institute (ETSI) for integrating heterogeneous devices and services. Smart Home is one of the areas covered by ETSI M2M standards, however these standards are just standardized, so adaption and assessment in smart home are not proved yet. Therefore, this paper analyze ETSI M2M standards by focusing the data transport model and evaluate by selecting the most commonly used smart home scenarios and by implementing ETSI M2M standards compatible smart metering system. In some points ETSI M2M standards are not efficient because of its complexity of structure, however ETSI M2M provides sophisticated features for integrating M2M which are appropriate to adopt diverse smart home environments.

Effect of Nonlinear Terms on the Generation of $M_2$ Tide Residual Elevation and $M_4$ Tide in the Yellow Sea and the East China Sea (황해ㆍ동중국해의 $M_2$ 조석 잔차위 및 $M_4$ 조석 생성에 대한 비선형항의 영향)

  • 이종찬;정경태;최병호
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.8 no.2
    • /
    • pp.137-145
    • /
    • 1996
  • Effects of nonlinear terms on the generation of M$_2$ tide residual elevation and M$_4$ tide in the Yellow Sea and the East China Sea are investigated using a depth-integrated two-dimensional nonlinear M$_2$tidal model. The model domain (117$^{\circ}$E-130$^{\circ}$E, 24$^{\circ}$N-41$^{\circ}$N) covers the whole region of the Yellow Sea and the East China Sea with grid resolution of 1/6$^{\circ}$ in longitude and 1/8$^{\circ}$in latitude. A radiational boundary condition is used along the open boundaries. Calculations show that advection terms yield negative residual elevation, while shallow-water terms in continuity equation yield positive residual elevation. The contribution of both advection terms and shallow-water terms to tile generation of the M$_4$ constituent is more than 90 percents, but that of quadratic bottom friction terms to the M$_4$ constituent is comparatively small.

  • PDF

A Sensitivity Test on the Minimum Depth of the Tide Model in the Northeast Asian Marginal Seas (동북아시아 조석 모델의 최소수심에 대한 민감도 분석)

  • Lee, Ho-Jin;Seo, Ok-Hee;Kang, Hyoun-Woo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.5
    • /
    • pp.457-466
    • /
    • 2007
  • The effect of depth correction in the coastal sea has been investigated through a series of tide simulations in the area of $115{\sim}150^{\circ}E,\;20{\sim}52^{\circ}N$ of northwestern Pacific with $1/12^{\circ}$ resolution. Comparison of the solutions varying the minimum depth from 10m to 35 m with the 5m interval shows that the amplitude accuracies of $M_2,\;S_2,\;K_1$ tide using the minimum depth of 25 m have been improved up to 42%, 32%, 26%, respectively, comparing to those using the minimum depth of 10m. The discrepancy between model results using different minimum depth is found to be up to 20 cm for $M_2$ tidal amplitude around Cheju Islands and the positions of amphidromes are dramatically changed in the Bohai Sea. The calculated ARE(Averaged Relative Error) values have been minimized when the bottom frictional coefficient and the minimum depth is 0.0015 and 25 m, respectively.

Effects of implant alignment and load direction on mandibular bone and implant: finite element analysis (임플란트 배열과 하중 방향이 임플란트와 치조골에 미치는 유한요소 응력분석)

  • Chung, Hyunju;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Yang, Hongso
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.3
    • /
    • pp.176-182
    • /
    • 2020
  • Purpose: To evaluate the effects of load direction, number of implants, and alignment of implant position on stress distribution in implant, prosthesis, and bone tissue. Materials and Methods: Four 3D models were made to simulate posterior mandible bone block: two implants and 3-unit fixed dental prosthesis (FDP) with a pontic in the center (model M1), two implants and 3-unit FDP with a cantilever pontic at one end (model M2), FDP supported by three implants with straight line placement (model M3) and FDP supported by three implants with staggered implant configuration (model M4). The applied force was 120 N axially or 120 N obliquely. Results: Peak von Mises stresses caused by oblique occlusal force were 3.4 to 5.1 times higher in the implant and 3.5 to 8.3 times higher in the alveolar bone than those stresses caused by axial occlusal force. In model M2, the connector area of the distal cantilever in the prosthesis generated the highest von Mises stresses among all models. With the design of a large number of implants, low stresses were generated. When three implants were placed, there were no significant differences in the magnitude of stress between staggered arrangement and straight arrangement. Conclusion: The effect of staggering alignment on implant stress was negligible. However, the number of implants had a significant effect on stress magnitude.

A Study on the Sediment Deposition Height Computation at Gunsan Port Using EFDC (EFDC를 이용한 군산항의 유사 퇴적고 계산에 관한 연구)

  • Lee, Dong Joo;Park, Young Ki
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.5
    • /
    • pp.531-545
    • /
    • 2013
  • This paper was considered on the applicability of EFDC KUNSAN_SEDTRAN MODEL (2012) to calculate Gunsan Port sediment deposition height efficiently and to use for grasping its aspects quantitatively and providing its prevention measures reasonably based on well-known 3-dimensional EFDC sediment transport module. This model was calibrated and verified with various measured field data of A Report of Hydrological Variation on Kum River Estuary (2004). Due to the model calibration and relevant literature investigation for cohesive sediment parameters, settling velocity (WS), critical deposition stress (TD), reference surface erosion rate (RSE), critical erosion stress (TE) were identified as 2.2E-04m/s, 0.20 $N/m^2$, 0.003 $g/s{\cdot}m^2$, 0.40 $N/m^2$ respectivly on this model. In order to examine the applicability and precision of the model computation, the calculated model data of sediment deposition height at 13 stations for 71 days and suspended-sediment concentration at 2 stations, inner port and outer port for 15 days were compared and analyzed with the measured field data. As a result, the model applicability for sediment deposition height simulation was evaluated as NSE coefficient 0.86 and the precision for suspended-sediment concentration computation was evaluated as time averaged relative error (RE) 23%.