• Title/Summary/Keyword: M2M Model

Search Result 7,888, Processing Time 0.039 seconds

우리나라 인공호의 부영양화 평가 및 예측에 관한 연구

  • 김재윤
    • Journal of Environmental Science International
    • /
    • v.7 no.4
    • /
    • pp.441-450
    • /
    • 1998
  • The purpose of this study is to evaluate and to predict of eutrophication in lakes by using VollenweiderGECD model and total phosphorus concentration and inflow rate which were measurded in 1993-1996. The results of study was as follows. The annual total phosphorus loading from the watershed was calculated to be 181-195tP /yr at lake Soyang, 591-680tP/yr at lake Chungju, 420-466tP/yr at lake Taechong, 229-278tP/yr at lake Andong, 103-106tP/yr at lake Hapchon, 57-59tP/yr at lake Imha, 194-244tP/yr at lake Namgang, 8386tP /yr at lake Chuam, 99-109tP /yr at lake Somjin. These are discharged, for the most parts, from population and ftshfarm facility. TP loading on the surface area at lake Soyang was 3.0lgP/$m^2$/yr, 2.82gP/$m^2$/yr, 2.84gP/$m^2$/yr, 3. 03gP/$m^2$/yr, at lake Chungju 7.91gP/$m^2$/yr, 6.87gP/$m^2$/yr, 7.38gP/$m^2$/yr, 7.l8gP/$m^2$/yr, at lake Taechong 6.7lgP/$m^2$/yr, 7.25gP/$m^2$/yr, 7.24gP/$m^2$/yr, 6.53gP/$m^2$/yr and TP loading on the surface area of Nakdong river basin, that is, lake Andong, Imha, Hapchon and Namgang were 5.39gP/$m^2$/yr, 4.47gP/$m^2$/yr, 4. 56gP/$m^2$/yr, 4.45gP/$m^2$/yr and 2.20gP/$m^2$/yr, 2.23gP/$m^2$/yr, 2.24gP/$m^2$/yr, 2.l7gP/$m^2$/yr and 4.50gP/$m^2$/ yr, 4.50gP/$m^2$/yr, 4.54gP/$m^2$/yr, 4.43gP/$m^2$/yr and 8.25gP/$m^2$/yr, 8.48gP/$m^2$/yr, 8.48gP/$m^2$/yr, 10. 39gP/$m^2$/yr respectively. Also those of lake Chuam was 2.51gP/$m^2$/yr, 2.61gP/$m^2$/yr, 2.52gP/$m^2$/yr, 2. 54gP/$m^2$/yr and TP loading on the surface area at lake Somjin was analysed 4.09gP/$m^2$/yr, 4.l0gP/$m^2$/yr, 3.98gP/$m^2$/yr,3.73gP/$m^2$/yr. The tropic states of nine lakes can be assessed as eutrophy because phosphorus loading exceeds the critical phosphorus loading by Vollenwelder-GECD model.

  • PDF

Moving Distance of Laborer in the Kitchen for Systematic of the Korean Foods (한식(韓食)의 편의식화(便宜食化)를 위한 주방동선(?房動線)에 관한 연구)

  • Park, Hyung-Woo;Koh, Ha-Young;Kang, Tong-Sam
    • Journal of the Korean Society of Food Culture
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 1987
  • In order to develop a convenient Korean food service system in commercial kitchen, processing procedure and recipe of 10 kinds of Korean food to be served as a convenient foods were decided. Moving distance and required energy of laborer in the commercial and model restaurants which have the area of $62.8m^2$ and $32.4m^2$, respectively, were measured by arranging these machinery. The results obtained were summarized as follows. In case of restaurant with the area of $62.8m^2$, moving distance, working hours and required energy of laborers were 1,922m, 2,986min and 4,704kcal in C-store, 2,134m, 3,173min and 5,001.7kcal in T-store, and 1,704m, 2,808min and 4,414.5kcal in model restaurant, respectively. Therefore energy requirements of the model restaurant were less 289.5kcal (4.5%) and 587.2kcal (10.1%) than those of C and T store. In case of restaurant with the area of $32.4m^2$, moving distance, working hours and required energy of laborer in S store were 1,277m, 2,926min and 4,588kcal, 1,425m, 3,108min and 4,873.8kcal in H restaurant and 1,167m, 2,798min and 4,381.4kcal in model restaurant, respectively. Therefore energy requirements of the model restaurant were less 206.6kcal (4.7%) and 492.4kcal (11.2%) than those of S store and H restaurant. When 6 kinds of convenient foods and 4 kinds of direct cooking foods were produced, moving distance, working hours and required energy of laborer in S store were 554.7m, 972min and 1,586.0kcal, 684.7m, 991min and 1,579.2kcal in H restaurant, 523.1m, 938min and 1,479.5kcal in model restaurant. Therefore energy requirements of the model restaurant were less 99.7kcal(6.7%) and 106.5kcal(7.2%) than those of S store and H restaurant. In case of the energy saving system kitchen, moving distance and required energy were saved less by 42% and by 20.4% than those of model kitchen, respectively.

  • PDF

A Large Sky Simulator : A Reproduction of CIE Sky Condition and Daylighting Evaluation using Scale Model

  • Yu, In-Hye;Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.1-10
    • /
    • 2007
  • KH University has developed a large sky simulator which is its scale suits international standard. To verify the reliability of the sky simulator, the luminance of 36 points on the inner sky surface was measured and compared with the CIE standard overcast sky model. It was found that the sky simulator can reproduce the CIE standard overcast sky condition with 1.8[%] of mean difference. To identify the differences of daylighting performance, scale model measurements were taken under a real sky and in a sky simulator. Under overcast sky conditions, two kinds of scale model experiments were conducted by using the photometric sensor Li-cor. Firstly, a 1/20 scale model of a side-lit office room 4.9[m] wide, 7.2[m] long, and 2.6[m] high was created. Five measurement points were set at 1.2[m], 2.4[m], 3.6[m], 4.8[m], and 6.0[m] from the window. The mean difference of the light factor between the sky simulator and real sky was 7.1[%]. Secondly, a 1/30 scale model of a top-lit atrium 15[m] wide, 15[m] long, and 15[m] high was created. The measurement point was set at center of the room and the well indexes of the model were set in 5 types. The mean difference of the light factor between the sky simulator and real sky was 1.7[%]. This proved that the sky simulator is fully accurate and usable for daylighting research.

Two- and Three-dimensional Analysis on the Bubble Flow Characteristics Using CPFD Simulation

  • Lim, Jong Hun;Lee, Dong Hyun
    • Korean Chemical Engineering Research
    • /
    • v.55 no.5
    • /
    • pp.698-703
    • /
    • 2017
  • Bubble flow characteristics in fluidized beds were analyzed by CPFD simulation. A fluidized bed, which had the size of $0.3m-ID{\times}2.4m-high$, was modeled by commercial CPFD $Barracuda^{(R)}$. Properties of bed material were $d_p=150{\mu}m$, ${\rho}_p=2,330kg/m^3$, and $U_{mf}=0.02m/s$. Gas was uniformly distributed and the range of superficial gas velocity was 0.07 to 0.16 m/s. Two other geometries were modeled. The first was a three-dimensional model, and the other was a two-dimensional model of $0.01m{\times}0.3m{\times}2.4m$. Bubble size and rising velocity were simulated by axial and radial position according to superficial gas velocity. In the case of three-dimensional model, simulated bubble rising velocity was different from correlations, because there was zigzag motion in bubble flow, and bubble detection was duplicated. To exclude zigzag motion of bubble flow, bubble rising velocity was simulated in the two-dimensional model and compared to the result from three-dimensional model.

Kinetics of Horseradish Peroxidase-Catalyzed Nitration of Phenol in a Biphasic System

  • Kong, Mingming;Zhang, Yang;Li, Qida;Dong, Runan;Gao, Haijun
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.2
    • /
    • pp.297-305
    • /
    • 2017
  • The use of peroxidase in the nitration of phenols is gaining interest as compared with traditional chemical reactions. We investigated the kinetic characteristics of phenol nitration catalyzed by horseradish peroxidase (HRP) in an aqueous-organic biphasic system using n-butanol as the organic solvent and ${NO_2}^-$ and $H_2O_2$ as substrates. The reaction rate was mainly controlled by the reaction kinetics in the aqueous phase when appropriate agitation was used to enhance mass transfer in the biphasic system. The initial velocity of the reaction increased with increasing HRP concentration. Additionally, an increase in the substrate concentrations of phenol (0-2 mM in organic phase) or $H_2O_2$ (0-0.1 mM in aqueous phase) enhanced the nitration efficiency catalyzed by HRP. In contrast, high concentrations of organic solvent decreased the kinetic parameter $V_{max}/K_m$. No inhibition of enzyme activity was observed when the concentrations of phenol and $H_2O_2$ were at or below 10 mM and 0.1 mM, respectively. On the basis of the peroxidase catalytic mechanism, a double-substrate ping-pong kinetic model was established. The kinetic parameters were ${K_m}^{H_2O_2}=1.09mM$, ${K_m}^{PhOH}=9.45mM$, and $V_{max}=0.196mM/min$. The proposed model was well fit to the data obtained from additional independent experiments under the suggested optimal synthesis conditions. The kinetic model developed in this paper lays a foundation for further comprehensive study of enzymatic nitration kinetics.

Consequence Analysis of the Fire & Explosion on the Flammable Liquid Handling Facility and LPG Station (제 4류 위험물 취급소 및 LPG 충전소의 화재$\cdot$폭발 피해 영향분석)

  • Lee Su-Kyung;Lee Chang-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.2 s.7
    • /
    • pp.77-84
    • /
    • 1999
  • The XX company that is handling the class IV hazardous materials, located in Bu-Chon City and the LPG station in front of the XX company which is about 20 meters apart, was chosen as the standard model for this study In carrying out the consequence analysis, PHAST and Super-Chems were used for the study and utilizing the output of the simulation, we have evaluated the consequences throughout the probit analysis and explosion overpressure analysis. In case of Acetone, the effect distance of the damage on facilities-that is the result of radiation heat flux of $37.5kW/m^2$ by TNO model-is 68.51m by PHAST model and 40.93m by Super-Chem model. The risk assessment of the LPG station which is based on the explosion resulted as the analysis of the fire ball showed the diameter 125.2m, the height 206.2m and the duration 11.28sec and the effect distance for the radiant heat flux $37.5kW/m^2$ was 137.0m.

  • PDF

M2M Architecture: Can It Realize Ubiquitous Computing in Daily life?

  • Babamir, Seyed Morteza
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.2
    • /
    • pp.566-579
    • /
    • 2012
  • Ubiquitous computing called pervasive one is based on the thought of pervading ability of computation in daily life applications. In other words, it aims to include computation in devices such as electronic equipment and automobiles. This has led to disengagement of computers from desktop form. Accordingly, the notice in ubiquitous computing being taken of a world steeped in remote and wireless computer-based-services. Handheld and wearable programmed devices such as sense and control appliances are such devices. This advancement is rapidly moving domestic tasks and life from device-and-human communication to the device-and-device model. This model called Machine to Machine (M2M) has led to acceleration of developments in sciences such as nano-science, bio-science, and information science. As a result, M2M led to appearance of applications in various fields such as, environment monitoring, agricultural, health care, logistics, and business. Since it is envisaged that M2M communications will play a big role in the future in all wireless applications and will be emerged as a progressive linkage for next-generation communications, this paper aims to consider how much M2M architectures can realize ubiquitous computing in daily life applications. This is carried out after acquainting and initiating readers with M2M architectures and arguments for M2M. Some of the applications was not achievable before but are becoming viable owing to emergence of M2M communications.

Comparison of the accuracy of domestic dental intra-oral scanner(e-scanner) and model scanner (국산 치과용 구강스캐너(e-scanner)와 모델스캐너의 정확도 비교)

  • Kim, Busob;Kim, Jungho
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.53-61
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the discrepancy of scan process in dental intra oral scanner by comparing model scanner and anticipate possibility to introduce intra oral scan technique. Methods: 3D superimposition test was conducted to compare the scan discrepancy. The scanners used in this study are the e-oral scanner, the D750 model scanner, and the high precision CMM(3D Coordinate Measuring Machine). The standard of accuracy verification is ISO 5725-1; trueness and precision. Master model was manufactured by dental stone and scanned 5 times by intra oral, model scanner. Reference data was scanned 5 times by high accuracy CMM to evaluate the trueness. Results: Trueness of D750 scanner were $7.4{\mu}m$ $5.1{\mu}m$ $6.8{\mu}m$ at an abutment, an occluasal, a specific area. and trueness of e-scanner were $20.2{\mu}m$ $27.4{\mu}m$ $37.8{\mu}m$ at an abutment, an occluasal, a specific area. Precision of D750 scanner was $7.04{\mu}m$, e-scanner was $15.95{\mu}m$. Conclusion: When conducting in vitro test, The mean difference of trueness between e-scanner and D750 were $12.8{\mu}m$ at an abutment area, $22.3{\mu}m$ at an occlusal area, $31.0{\mu}m$ at a specific area and $8.91{\mu}m$ in precision. The scan discrepancies are within the range of clinical acceptance.

Development of Fishway Assessment Model based on the Fishway Structure, Hydrology and Biological Characteristics in Lotic Ecosystem

  • Choi, Ji-Woong;Park, Chan-Seo;An, Kwang-Guk
    • Journal of Ecology and Environment
    • /
    • v.39 no.1
    • /
    • pp.71-80
    • /
    • 2016
  • The main goal of this study is to develop a multi-metric fishway assessment model (Mm-FA) and evaluate the efficiency of fishway. The Mm-FA model has three major fishway components with nine metrics: structural characteristics, hydraulic/hydrologic features, and biological attributes. The model was developed for diagnosing and assessing fishway efficiency and tested to Juksan Weir at the Yeongsan River Watershed. Structural characteristics of fishway included slope of the fishway (M1), ratios of fishway width to stream width (M2), and the proportion of orifice clogging and orifice size (M3). Hydraulic/hydrologic characteristics included depth of fishway entrance head (M4), depth of exit tail (M5), and current velocity of inner fishway (M6). Biological characteristics included fish species ratio of inner fishway to upper-lower weir (M7), fish length distribution (M8), and the proportion of migratory fish species to the total number of species (M9). Overall, the assessment of fishway efficiency showed the total score of the Mm-FA model was 25 in the Juksan Weir, indicating "good condition" by the criteria of the five-level classification system. The Mm-FA model may be used as a key tool for the assessment of fishway efficiency, especially on the 16 weirs constructed for the "Four Rivers Restoration Project" after a partial calibration of Mm-FA model.