• Title/Summary/Keyword: M-way below

Search Result 69, Processing Time 0.025 seconds

Impact of Seawater Inflow by the Operation of Sluice Gates on the D.O and pH in the Lake Shihwa, Korea (시화호 배수갑문 운용에 따른 용존산소와 pH 변화)

  • Choi, Jung-Hoon;Kim, Mi-Ock
    • Journal of the Korean earth science society
    • /
    • v.22 no.3
    • /
    • pp.195-207
    • /
    • 2001
  • The variations of D.O and pH due to the inflow of seawater by sluice gates operation were observed in the Lake Shihwa, Korea. The distributions of D.O and pH were investigated at 11 stations during Feburary 1997 to July 1998. The concentration of D.O before gate operation was 10 mg/l or more all over the watershed, yet 5 mg/l or less in the water layers of 11 m or below from March to June 1997. Anoxic layer appeared in June 1997 and expanded during rainy season. The anoxic layer in the lake depleted the oxygen in seawater as seawater was inflowed. It may be interpreted that the phenomenon comes from the contact of seawater to lower fresh water. The contact of seawater in pH 7.8 to 8.2 to lower water less than pH 7.4 enhanced to oxidize. After January 1998, D.O of the lake increased over 10 mg/l and the stratification was weakened. As a result, it may be concluded that the best way to improve the water qualities is to increase the amount of seawater inflow and outflow so as not to be generated pycnocline in summer.

  • PDF

Evaluation of Water Quality Characteristics of Floor Fountains in Gwangju (광주지역 바닥분수의 수질특성 평가)

  • Kim, Jong-Min;Kim, Ha-Ram;Jang, Seo-Eun;Choi, Yeong-Seop;Kang, Yu-Mi;Jung, Sook-Kyoung;Cho, Young-Gwan;Kim, Eun-Sun
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.2
    • /
    • pp.143-156
    • /
    • 2017
  • The purpose of this study was to investigate water quality through a field survey at six floor fountain sites. The floor fountain facilities were designed and operated in such a way that tap water was stored in a water tank and recycled repeatedly. The water tank was cleaned once or twice per week in the summer. The number of facility users was low during the day due to sweltering heat, but up to 40 people, mainly children, were using them around 8 pm. Since the operation time was as short as 30 minutes, it is considered necessary to extend it for at least one hour for the number of users. As a result of the water quality test of the reservoir tank prior to operation after cleaning, it was measured to be within drinking water quality standards at the six facilities. As a result of the water quality test after use, ammonia nitrogen was measured to be 1.45 mg/L at Site IV. This exceeded the drinking water quality standard of 0.5 mg/L. In the case of turbidity, two cases exceed at 7.38 and 4.52 NTU when applying 4 NTU as the water quality standard for waterscape facilities. Twenty-eight cases exceed the standard of drinking water quality. The result of microbiological tests, at five sites excepting Site I, where disinfectant was injected, was that the maximum total colony count was 180,000 CFU/mL, total coliforms was 2,100,000 CFU/100 mL, fecal coliforms was 4,600 CFU/100 mL, Escherichia coli was 170 MPN/100 mL and Enterococcus was 100 CFU/100 mL. This exceeded the water quality standards of drinking water. Children are very likely to inhale because the water spews from below and falls from above, so it is necessary to apply water quality standards for ammonia nitrogen, turbidity and microbes. Current floor fountain facilities are highly susceptible to disease caused by microbial contamination because of water cycling and reuse, so it is necessary to change the water every day, clean the water tank, and perform chlorination. Therefore, it is necessary to inject calcium hypochlorite according to the free chlorine water quality standard of swimming pools with a different water tank capacity. In addition, facilities should be improved to prevent the reuse of water by installing the water tank at a separate location.

Fabrication and characterization of ZrxCe1-xO2 catalytic powder by a hydrothermal process (수열합성공정에 의한 ZrxCe1-xO2 촉매 분말의 제조 및 특성)

  • Choi, Yeon-Bin;Son, Jeong-hun;Sohn, Jeong Ho;Bae, Dong-Sik
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.6
    • /
    • pp.309-312
    • /
    • 2017
  • The ceria powder is excellent in oxygen storage capacity (OSC) through the oxidation and reduction reaction of Ce ions and is used as a typical material for a three-way catalyst of an automobile which purifies the exhaust gas. However, since ceria generally has poor thermal stability at high temperatures, it is doped with metal ions to improve thermal stability. Therefore, in this study, Zr ions were doped into ceria powder, and their characteristics were further improved due to the increase of specific surface area with decreasing particle size due to doping. In this study, the synthesis of zirconium doped ceria nanopowder was synthesized by hydrothermal process. In order to synthesis Zr ion doped ceria nanopowder, the precursor reaction at was $200^{\circ}C$ for 6 hours. The average particle size of synthesized Zr doped $CeO_2$ nanopowder was below 20 nm. The specific surface area of synthesized Zr ion doped ceria nanopowder increased from $52.03m^2/g$ to $132.27m^2/g$ with Zr increased 30 %.

Setting Guidelines for ATP Bioluminescence Hygiene Monitoring of Distribution Trays in Used Children's Foodservices (어린이 급식소의 배식용기 표면에 대한 ATP(Adenosine Triphosphate) 위생 모니터링 가이드라인 설정)

  • Moon, Hye-Kyung
    • Journal of the Korean Dietetic Association
    • /
    • v.26 no.4
    • /
    • pp.243-253
    • /
    • 2020
  • The purpose of this study was to set new guidelines for adenosine triphosphate (ATP) bioluminescence hygiene monitoring of distribution trays at children's foodservices. Five dietitians visited 223 foodservices (95 institutional, 128 small) to examine whether they adhered to the norms of 'Keeping distribution tray sanitary by washing/sanitizing' and 'Performing food distribution in a clean and appropriate way'. In this visit, dietitians swabbed 100 ㎠ area of the distribution trays twice, once for obtaining ATP measurements and the second time for Aerobic Plate Counts (APC) using 3M Petrifilm Plates. Chi-square test and ANOVA were applied using SPSS 23.0 software. SPSS 23.0 was used to conduct graphical and statistical analysis of the raw data of ATP measurements, which were further transformed by a Box-Cox transformation. The mean of APC from all the subjects inspected was 3.8×102±2,102.0 CFU/100 ㎠. A total of 208 (93.3%) trays were observed within the acceptable limits of APC (Pass<5.0×102 CFU/100 ㎠). APCs taken at institutional foodservices showed significantly lower levels (1.4×102±600.0 CFU/100 ㎠, P<0.01) compared to the small foodservices (5.5×102±2,718.7 CFU/100 ㎠). No significant differences were observed between the two groups in ATP measurements and in the performance rate of 2 checklist items. As against the 93.3% APC adequacy from the total subjected inspection, total ATP adequacy (Pass≤300 RLU/100 ㎠) was only 71.7%. Therefore, more practical guidelines should be prepared for the assessment of the hygiene of distribution trays. In the graphical and statistical analysis, levels below 250 RLU/100 ㎠ was considered 'Pass', while equal to or greater than 350 RLU/100 ㎠ was considered 'Fail' for distribution trays.

Study on Critical Impact Point for a SB2 Class Flexible Barrier (SB2등급 연성베리어의 충돌지점(CIP)에 대한 연구)

  • Heo, Yeon Hee;Kim, Yong Guk;Ko, Man Gi;Kim, Kee Dong
    • International Journal of Highway Engineering
    • /
    • v.15 no.4
    • /
    • pp.127-133
    • /
    • 2013
  • PURPOSES : The impact performance of flexible barrier system such as structural response, vehicular motion and occupant safety vary depending on the impact point. Thus, to properly evaluate the performance of a flexible barrier system, impact should be made to a point which will lead to the worst possible results. This point is called the Critical Impact Point (CIP). This paper presents the way to determine the CIP for a SB2 class flexible barrier system which is consisted of Thrie-Beam rail and circular hollow tube post of 2m span. METHODS: Barrier VII simulations were made for impact points; Case 1 at a post, Case 2 at 1/3 span downstream from a post, Case 3 at middle of the span, Case 4 at 2/3 span downstream from a post. For the structural performance (deflections), impact simulation of 8000kg-65km/h-15degree was used, and for vehicle motion and occupant safety, simulation of 1300kg-80km/h-20degree impact was made and analysed. RESULTS: Case 1 gave the largest dynamic deflection of 75.72cm and also gave the largest snag value of 44.3cm. Occupant safety and exit angle of the vehicle after the impact were not sensitive to the impact point and were all below the allowable limit. CONCLUSIONS : For the SB2 class flexible barrier system's CIP can be regarded as a post which is sufficiently away from the end of Length of Need in order to avoid the end-effect of the barrier system. It can be more economic in the long run because the normal concrete pavement material is likely to cost more due to higher probability of maintenance and repair and higher social cost due to traffic accident, etc.

Seismic interval velocity analysis on prestack depth domain for detecting the bottom simulating reflector of gas-hydrate (가스 하이드레이트 부존층의 하부 경계면을 규명하기 위한 심도영역 탄성파 구간속도 분석)

  • Ko Seung-Won;Chung Bu-Heung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.638-642
    • /
    • 2005
  • For gas hydrate exploration, long offset multichannel seismic data acquired using by the 4km streamer length in Ulleung basin of the East Sea. The dataset was processed to define the BSRs (Bottom Simulating Reflectors) and to estimate the amount of gas hydrates. Confirmation of the presence of Bottom Simulating reflectors (BSR) and investigation of its physical properties from seismic section are important for gas hydrate detection. Specially, faster interval velocity overlying slower interval velocity indicates the likely presences of gas hydrate above BSR and free gas underneath BSR. In consequence, estimation of correct interval velocities and analysis of their spatial variations are critical processes for gas hydrate detection using seismic reflection data. Using Dix's equation, Root Mean Square (RMS) velocities can be converted into interval velocities. However, it is not a proper way to investigate interval velocities above and below BSR considering the fact that RMS velocities have poor resolution and correctness and the assumption that interval velocities increase along the depth. Therefore, we incorporated Migration Velocity Analysis (MVA) software produced by Landmark CO. to estimate correct interval velocities in detail. MVA is a process to yield velocities of sediments between layers using Common Mid Point (CMP) gathered seismic data. The CMP gathered data for MVA should be produced after basic processing steps to enhance the signal to noise ratio of the first reflections. Prestack depth migrated section is produced using interval velocities and interval velocities are key parameters governing qualities of prestack depth migration section. Correctness of interval velocities can be examined by the presence of Residual Move Out (RMO) on CMP gathered data. If there is no RMO, peaks of primary reflection events are flat in horizontal direction for all offsets of Common Reflection Point (CRP) gathers and it proves that prestack depth migration is done with correct velocity field. Used method in this study, Tomographic inversion needs two initial input data. One is the dataset obtained from the results of preprocessing by removing multiples and noise and stacked partially. The other is the depth domain velocity model build by smoothing and editing the interval velocity converted from RMS velocity. After the three times iteration of tomography inversion, Optimum interval velocity field can be fixed. The conclusion of this study as follow, the final Interval velocity around the BSR decreased to 1400 m/s from 2500 m/s abruptly. BSR is showed about 200m depth under the seabottom

  • PDF

Digital Map Updates with UAV Photogrammetric Methods (무인항공사진측량 방법에 의한 수치지도 갱신)

  • Lim, Soo Bong;Seo, Choon Wook;Yun, Hee Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.5
    • /
    • pp.397-405
    • /
    • 2015
  • Currently, Korea's digital maps are being produced through traditional aerial photogrammetry methods. Aerial photogrammetry is the most economical way to produce a map of a wide area. However, timely survey is not allowed depends on weather condition and it is inefficient for small area surveying in economic point of view. Therefore, it costs too much and needs long time to produce a map for various small areas where are terrestrial changes for updating the map. In contrast, UAV photogrammetry is possible to work even in cloudy weather because of shooting at low altitude below the clouds. It also has excellent mobility and shoot quickly and well suited for small-scale mapping in several places by low cost. In this study, we produced an ortho-photo and digital map with the UAV photogrammetry method using SIFT and SfM algorithm and verified its accuracy to evaluate the applicability for future digital map updates. The accuracy was verified by comparing the results of the ground survey for check points selected on the digital map. Test results show small errors at ±2.6cm in X coordinates, ±2.8cm in Y coordinates and ±5.8cm in height and we could find a possibility that UAV photogrammetry would be fully applicable for digital map updating.

Phonology and Minimum Temperature as Dual Determinants of Late Frost Risk at Vineyards (발아시기 정밀추정에 의한 포도 만상해 경보방법 개선)

  • Jung, Jea-Eun;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.8 no.1
    • /
    • pp.28-35
    • /
    • 2006
  • An accurate prediction of budburst in grapevines is indispensable for vineyard frost warning system operations in spring because cold tolerance depends heavily on phonology. However, existing frost warning systems utilize only daily minimum temperature forecasts since there is no way to estimate the site-specific phonology of grapevines. A budburst estimation model based on thermal time was used to project budburst dates of two grapevine cultivars (Kyoho and Campbell Early), and advisories were issued depending on phonology as well as temperature. A 'warning' is issued if two conditions are met: the forecasted daily minimum temperature falls below $-1.5^{\circ}C$ and the estimated phonology is within the budburst period. A 'watch' is issued for a temperature range of -1.5 to $+1.5^{\circ}C$ with the same phonology condition. Validation experiments were done at 8 vineyards in Anseong in spring 2005, and the results showed a good agreement with the observations. This method was applied to the climatological normal year (1971-2000) to determine sites with high frost risk at a 30 m grid cell resolution. Among 608,585 grid cells constituting Anseong, 1,059 cells were identified as high risk for growing Kyoho and 2,788 cells for Campbell Early.

Solid Flow Rate and Gas Bypassing with Operating Variables of J-valve in Multistage Annular Type Fluidized Beds (다단 환원형 유동층에서 J-valve의 운전변수에 따른 고체 흐름량 및 기체 우회)

  • Hong, Yoon-Seok;Kang, Gyung-Soo;Park, Joo-Sik;Lee, Dong-Hyun
    • Clean Technology
    • /
    • v.17 no.1
    • /
    • pp.62-68
    • /
    • 2011
  • Hydrodynamic characteristics in multistage annular type fluidized bed (riser: $0.01{\times}0.025{\times}2.8m^3$, J-valve: $0.009{\times}0.015m^2$)were investigated. Glass beads ($d_p=101{\mu}m$, ${\rho}_b=1,590kg/m^3$, $U_{mf}=1.25{\times}10^{-2}m/s$, Geldart classification B) was used as a bed material. Accumulated weight by the electronic balance was measured to determine the solid flow rate in batch-type. In circulation condition, we measured the accumulated weight of particle transported from riser. At the steady state condition, solid circulation rate was calculated from time interval of the heated bed material passing between two thermocouples. Solid flow rate increased with increasing inlet gas velocity ($1.2-2.6U_{mf}$) and the static bed height (z, 0.24-0.68 m) from 2.2 to 23.4 kg/s. However, mean residence time decreased with increasing inlet gas velocity ($1.2-2.6U_{mf}$) and the static bed height (z, 0.24-0.68 m) from 1,438 to 440 s. The solid holdup in the riser was determined by measuring pressure differences according to the riser height. These results showed a similar trend to that of simple exponential decay type except for the top section of the riser. To verify the gas bypassing from top bubbling beds to middle bubbling beds, $CO_2$ gas was injected by tracer gas in constant ratio, and then was measured $CO_2$ concentration in outlet gas by gas chromatography. Gas bypassing occurred below 2.6% which is negligible value.

Comparison of the DGPS Positioning Accuracies for Single and Multiple Reference Stations in the South Coast of Korea (한국 남해안에서 단일 및 복수 기준국에 의한 DGPS의 측위정도 비교)

  • Park, Noh-Seon;Shin, Hyeong-Il;Lee, Dae-Jae;Shin, Hyeon-Ok;Kim, Seok-Jae;Bae, Mun-Ki
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.3
    • /
    • pp.181-189
    • /
    • 2002
  • This paper describes the positioning accuracies for single and multiple reference stations at fixed stations in Yosu harbor and Pukyong National University in the south coast of Korea from Jan. to Oct. 2001. Also we observed the change of positioning accuracy during a day and the available range of the DGPS reference station. he results obtained are main summarized as follows; 1. With single DGPS reference station, 2drms and the average positioning .error were 5.6m, 7.3m respectively. Measurement positions indicated an incline toward one way away from the actual position. 2. With multiple DGPS reference stations, 2drms and the average position error were 5.5m, 3.2m for the arithmetic mean, respectively. They were 5.3m, 3.8m for the weighted average, respectively. As far as the separation between the user and the reference station, using multiple reference stations improved position accuracy more than using single reference station. 3. The average positioning error increased between 16: 00 and 22 : 00. The average number of observed satellite and HDOP were 7.1m, 0.49 respectively. 4. Coverage of DGPS reference stations in the south coast of Korea was estimated to be 110nm. Signal strength and signal to noise ratio was not available the DGPS signal below 19㏈, 8㏈ respectively.