• Title/Summary/Keyword: M-W Test

Search Result 1,335, Processing Time 0.039 seconds

순환식 병류형 곡물건조기 개발(III) - 12톤 용량 건조기 성능평가 - (Development of a Rice Circulating Concurrent-flow Dryer(III) - Performance Evaluation of 12-ton Capacity Dryer -)

  • 한재웅
    • Journal of Biosystems Engineering
    • /
    • 제34권5호
    • /
    • pp.358-362
    • /
    • 2009
  • This study was conducted to evaluate the performance of a 12 tons capacity circulating concurrent flow rice dryer. An actual scale dryer with the capacity of 12 tons was developed to obtain a faster drying rate of 0.8~1.2%(w.b.)/h, while maintaining a lower drying energy consumption of 5,000 kJ/kg-water and achieving a drying quality that was comparable to a conventional cross-flow rice dryer. The Test-1 was conducted at $110^{\circ}C\;-\;20\;cmm/m^2$ and the Test-2 was conducted at $120-110-100-90^{\circ}C\;-\;20\;cmm/m^2$ under the same conditions as Test-1. In Test-1, the drying rate, drying energy consumption and crack ratio were 0.98 %(w.b.)/h, 4,573 kJ/kg-water and 3.2%, respectively. In Test-2, the drying rate, drying energy consumption and crack ratio were 0.74 %(w.b.)/h, 4,790 kJ/kg-water and 4.0%, respectively. The results of these tests demonstrated that this concurrent-flow dryer reached the desired drying rate, drying energy consumption and crack ratio.

지하수 부존지역에서의 토질 및 암석 시료와 현장 열응답시험의 열전도도 비교 (Thermal Conductivity from an in-situ Thermal Response Test Compared with Soil and Rock Specimens under Groundwater-bearing Conditions)

  • 김진성;송성호;정교철
    • 지질공학
    • /
    • 제23권4호
    • /
    • pp.389-398
    • /
    • 2013
  • 국내에서 열물성에 관한 연구는 지역별, 암종별 열물성 파악을 위주로 진행되었으나, 지열냉난방시스템 설계 시에 실시하는 TRT (thermal response test)의 열전도도와 차이가 크게 나타남에 따라 본 연구에서는 지하수 부존량이 풍부한 지역에서 시료를 통한 열전도도와 TRT를 통한 열전도도를 비교하였다. 토양 시료의 열전도도는 1.32 W/m-K, 암석 시료의 열전도도는 2.88 W/m-K로 나타났으며, TRT로 측정된 열전도도는 3.13 W/m-K로 나타나 암석 시료보다 약 10% 정도 높게 나타났다. 연구지역은 지하수가 풍부하고 0.01의 수리경사를 가지고 있어 이 차이는 지하수 흐름에 의한 영향이라고 판단된다. 라인소스(line source) 이론에 따르면 TRT는 지반의 순수한 열전도도를 산정하는 것이 목적이므로, 국내 SCW (standing column well)형의 TRT는 라인소스 이론에 적합하지 않으며 지열냉난방시스템 설계 시에는 시료를 통한 열전도도값을 사용하는 것이 타당하다고 판단된다.

기계화시공에 의한 보수재료의 현장품질관리확립을 위한 실험적 연구 (An Experimental Study for Establishment of On-Site Quality Control of Repair Material by the mechanized construction)

  • 조봉석;장재봉;김용로;강석표;홍성윤;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.160-163
    • /
    • 2004
  • In domestic, various repair materials and method systems to keep up with these reinforced concrete deteriorated due to salt damage, carbonation, chemical decay et. developed and applied. However, on-site quality control of various repair materials and method systems isn't achieved desirably because it is depend completely on a men of experience' opinions above all else regardless of various on-site environments. In this background, mock up test with due regard to real on-site environments was performed to secure fundamental data for establishment of desirable on-site quality control. Mock up test using repair mortar analyzed from angles of construction methods, mechanical spraying pressures, W/M. Construction methods were designed manpower method and spraying method, spraying pressures were designed 32, 42, 52 psi, W/M were designed 14.4, 15.4, $16.4\%$. And compressive strength, Chloride ion diffusion coefficient, bond strength, SEM. of mock up test specimens were evaluated. In conclusion, we confirmed excellency of mechanical spraying pressures, fined extremely excellency of condition of spraying pressure 42 ps, W/M $14.4\%$ within this study. therefore the results of this study will be useful to provide fundamental data for establishment of desirable on-site quality control.

  • PDF

현장 열응답 시험을 통한 에너지파일의 열교환파이프 배열 방식에 따른 성능 비교 (Performance-based comparison of energy pile of various heat exchange pipe arrangement by in-situ thermal response test)

  • 민선홍;고형선;유재현;정경식;이영진;최항석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.196.1-196.1
    • /
    • 2011
  • In this study, a test bed was constructed in order to evaluate thermal efficiency of the energy pile which carries out combined roles of a structural foundation and of a heat exchanger. The energy pile in this study is designed as a large-diameter drilled shaft equipped with the heat exchange pipes which configures a W-shape and an S-shape. The drilled shaft reached to the depth of 60 m whilst the heat exchange pipes were installed to about 30 m deep from the ground surface. The W-shaped and S-shaped heat exchange pipes were installed in the opposite sections of the same drilled shaft. In-situ thermal response tests were performed for both the shapes of heat exchange pipes. To avoid underestimating the thermal performance due to hydration heat of concrete inside the drilled shaft, the in-situ thermal response tests for the energy pile were performed after four weeks since the installation of the energy pile.

  • PDF

CONFLICT AMONG THE SHRINKAGE ESTIMATORS INDUCED BY W, LR AND LM TESTS UNDER A STUDENT'S t REGRESSION MODEL

  • Kibria, B.M.-Golam
    • Journal of the Korean Statistical Society
    • /
    • 제33권4호
    • /
    • pp.411-433
    • /
    • 2004
  • The shrinkage preliminary test ridge regression estimators (SPTRRE) based on Wald (W), Likelihood Ratio (LR) and Lagrangian Multiplier (LM) tests for estimating the regression parameters of the multiple linear regression model with multivariate Student's t error distribution are considered in this paper. The quadratic biases and risks of the proposed estimators are compared under both null and alternative hypotheses. It is observed that there is conflict among the three estimators with respect to their risks because of certain inequalities that exist among the test statistics. In the neighborhood of the restriction, the SPTRRE based on LM test has the smallest risk followed by the estimators based on LR and W tests. However, the SPTRRE based on W test performs the best followed by the LR and LM based estimators when the parameters move away from the subspace of the restrictions. Some tables for the maximum and minimum guaranteed efficiency of the proposed estimators have been given, which allow us to determine the optimum level of significance corresponding to the optimum estimator among proposed estimators. It is evident that in the choice of the smallest significance level to yield the best estimator the SPTRRE based on Wald test dominates the other two estimators.

디지털 임피던스 보정과 이퀄라이저를 가진 1.88mW/Gb/s 5Gb/s 송신단 (A 1.88-mW/Gb/s 5-Gb/s Transmitter with Digital Impedance Calibration and Equalizer)

  • 김호성;백승욱;장영찬
    • 한국정보통신학회논문지
    • /
    • 제20권1호
    • /
    • pp.110-116
    • /
    • 2016
  • 본 논문에서는 디지털 임피던스 보정 회로와 이퀄라이저 회로를 가진 1.2V 5Gb/s SLVS 차동 송신단을 제안한다. 제안하는 송신단은 4-위상 출력 클록을 갖는 위상 고정 루프, 4-to-1 직렬변환기, 레귤레이터, 출력 드라이버, 그리고 신호보존성을 향상하기 위한 이퀄라이저 회로를 포함한다. 또한, built-in self-test를 위해 pseudo random bit sequence 발생기를 함께 구현한다. 제안하는 SLVS 송신단은 80mV에서 500mV의 차동 출력 전압범위를 지원한다. SLVS 송신단은 1.2V의 공급전압을 가지는 65nm CMOS공정을 이용하여 구현한다. 측정된 5Gb/s SLVS 송신단의 peak-to-peak 시간 지터는 46.67ps이며, 전력소모는 1.88mW/Gb/s이다.

평활관군의 R-134a 흐름비등에 관한 연구 (R-134a Flow Boiling on a Plain Tube Bundle)

  • 김종원;김정오;김내현
    • 설비공학논문집
    • /
    • 제13권1호
    • /
    • pp.9-17
    • /
    • 2001
  • In this study, flow boiling experiments were performed using R-134a on a plain tube bundle. Tests were conducted for the following range of variables; quality from 0.1 to 0.9, mass flux from $8\;kg/m^2s$ to $26\;kg/m^2s$ and heat flux from $10\;kW/m^2s$ to $40\;kW/m^2s$. The heat transfer coefficients were strongly dependent on the heat flux. However, they were almost independent on the mass flux or quality. The data are compared with the modified Chen model, which satisfactorily () predicted the data. Original Chen model, however, did not adequately predict the effect of quality. The reason may be attributed to the flow pattern of the present test, where the bubbly flow prevailed for the entire test range. The heat transfer coefficients of the tube bundle were 6~40% higher than those of the single tube pool boiling.

  • PDF

내열강 용접부의 크리프 평가 신기술 개발에 관한 연구 (A Study of New Technique Development for Creep Evaluation of Heat Resistant Steel Weldment(I))

  • 유효선;백승세;권일현;이송인
    • Journal of Welding and Joining
    • /
    • 제20권6호
    • /
    • pp.30-30
    • /
    • 2002
  • It has been reported that the creep characteristics on weldment which is composed of weld metal(W.M), fusion line(F.L), heat-affected zone(HAZ), and base meta(B.M) could be unpredictably changed in severe service conditions such as high temperature and high pressure. However, the studies done on creep damage in power plant components have been mostly conducted on B.M and not the creep properties of the localized microstructures in weldment have been thoroughly investigated yet. In this paper, it is investigated the creep characteristics for three microstructures like coarse-grain HAZ(CGHAZ), W.M, and B.M in X20CrMoV121 steel weldment by the small punch-creep-(SP-Creep) test using miniaturized specimen(l0×10×0.5mm). The W.M microstructure possesses the higher creep resistance and shows lower creep strain rate than the B.M and CGHAZ. In the lower creep load the highest creep strain rate is exhibited in CGHAZ, whereas in the higher creep load the B.M represents the high creep strain rate. The power law correlation for all microstructures exists between creep rate and creep load at 600℃. The values of creep load index (n) based on creep strain rate for B.M, CGHAZ, and W.M are 7.54, 4.23, and 5.06, respectively and CGHAZ which shows coarse grains owing to high welding heat has the lowest creep loade index. In all creep loads, the creep life for W.M shows the highest value.

내열강 용접부의 크리프 평가 신기술 개발에 관한 연구(I) (A Study on New Technique Development for Creep Evaluation of Heat Resistant Steel Weldment (I))

  • 유효선;백승세;권일현;이송인
    • Journal of Welding and Joining
    • /
    • 제20권6호
    • /
    • pp.754-761
    • /
    • 2002
  • It has been reported that the creep characteristics on weldment which is composed of weld metal(W.M), fusion line(F.L), heat-affected zone(HAZ), and base meta(B.M) could be unpredictably changed in severe service conditions such as high temperature and high pressure. However, the studies done on creep damage in power plant components have been mostly conducted on B.M and not the creep properties of the localized microstructures in weldment have been thoroughly investigated yet. In this paper, it is investigated the creep characteristics for three microstructures like coarse-grain HAZ(CGHAZ), W.M, and B.M in X20CrMoV121 steel weldment by the small punch-creep-(SP-Creep) test using miniaturized specimen($10{\times}10{\times}0.5mm$). The W.M microstructure possesses the higher creep resistance and shows lower creep strain rate than the B.M and CGHAZ. In the lower creep load the highest creep strain rate is exhibited in CGHAZ, whereas in the higher creep load the B.M represents the high creep strain rate. The power law correlation for all microstructures exists between creep rate and creep load at $600^{\circ}C$. The values of creep load index (n) based on creep strain rate for B.M, CGHAZ, and W.M are 7.54, 4.23, and 5.06, respectively and CGHAZ which shows coarse grains owing to high welding heat has the lowest creep loade index. In all creep loads, the creep life for W.M shows the highest value.