• Title/Summary/Keyword: M-Test

Search Result 14,519, Processing Time 0.047 seconds

Development and Characterization of Vertical Type Probe Card for High Density Probing Test (고밀도 프로빙 테스트를 위한 수직형 프로브카드의 제작 및 특성분석)

  • Min, Chul-Hong;Kim, Tae-Seon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.9
    • /
    • pp.825-831
    • /
    • 2006
  • As an increase of chip complexity and level of chip integration, chip input/output (I/O) pad pitches are also drastically reduced. With arrival of high complexity SoC (System on Chip) and SiP (System in Package) products, conventional horizontal type probe card showed its limitation on probing density for wafer level test. To enhance probing density, we proposed new vertical type probe card that has the $70{\mu}m$ probe needle with tungsten wire in $80{\mu}m$ micro-drilled hole in ceramic board. To minimize alignment error, micro-drilling conditions are optimized and epoxy-hardening conditions are also optimized to minimize planarity changes. To apply wafer level test for target devices (T5365 256M SDRAM), designed probe card was characterized by probe needle tension for test, contact resistance measurement, leakage current measurement and the planarity test. Compare to conventional probe card with minimum pitch of $50{\sim}125{\mu}m\;and\;2\;{\Omega}$ of average contact resistance, designed probe card showed only $22{\mu}$ of minimum pitch and $1.5{\Omega}$ of average contact resistance. And also, with the nature of vertical probing style, it showed comparably small contact scratch and it can be applied to bumping type chip test.

The Evaluation of Usefulness of Two Times Elution a Day of $^{99m}Tc$ Using $^{99}Mo$-$^{99m}Tc$ Generator ($^{99m}Tc$ 발생기의 24시간 내 2회 용출의 유용성 평가)

  • Kim, Jeong-Ho;Seo, Han-Kyung;Jeong, Yeong-Hwan;Kim, Yeong-Su;Kim, Byung-Cheol;Gwon, Yong-Ju;Lee, Jeong-Ok;Park, Yeong-Sun;Kim, Dong-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.83-86
    • /
    • 2010
  • Purpose: The Molybdenum which is the raw material of $^{99}Mo$-$^{99m}Tc$ generator (generator) is produced from the nuclear reactor. However, output has dwindled as the two nuclear reactors supplying the bulk of radioactive material-one in Chalk River, Ontario and the other in Petten, the Netherlands-have been closed for repairs or maintenance. This resulted in the enhancement of its price. Therefore we have tried to seek the new method which could run generator to increase activity of $^{99m}Tc$ in this study. Materials and Methods: The $^{99m}Tc$ activity obtained from 5 times elution for 5 days from Monday to Friday using two generators was compared with 10 times elution. Appearance test, pH test, LAL test, sterility test, chemical impurity(Al) test, radio chemical purity test, ratio of $^{99}Mo$/$^{99m}Tc$ activity test have been done to check the stability of $^{99m}Tc$ eluting from generator respectively. Results: The $^{99m}Tc$ activity obtained from 5 times elution for 5 days was 168.2 GBq (4545 mCi) and 10 times was 230.5 GBq (6230 mCi). All quality control tests were within normal limit. Conclusion: We got to know that 2 times elution a day obtained more $^{99m}Tc$ activity than one time elution in this study.

  • PDF

A quantitative test method for assessing solder joint reliability of FCBGA packages (FCBGA의 솔더조인트 신뢰성 보증을 위한 정량적인 시험법)

  • Go, Byeong-Gak;Park, Bu-Hui;Kim, Gang-Dong;Jang, Jung-Sun
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2005.05a
    • /
    • pp.933-937
    • /
    • 2005
  • FCBGA가 마더보드에 실장된 후 솔더 조인트에 균열이 생기면 단선이 발생한다. 솔더 조인트의 신뢰성을 평가하기 위한 방법 중 전단강도시험(shear test)은 약한 솔더 조인트를 판별하기 어려워 양품 로트와 불량 로트를 구별할 수 없으며, 인장강도시험(pull test)은 솔더 볼의 위치별 산포가 크고, peel test는 품질을 정량적으로 나타낼 수 없는 등의 문제가 있다. 새로운 시험 방법은 Area Pull Test(이하 APT)라 명명했으며 peel test와 pull test를 합한 개념으로서, 시험 샘플을 만드는 과정은 peel test와 동일하다. 솔더 조인트의 인장강도 측정은 지그를 만들어서 FCBGA 전체를 당겨서 측정하였다. 샘플은 Ni도금 두께를 3, 5, 8 ${\mu}m$로 제작하여 불량(3${\mu}m$), 양품으로 구분하였고, 양품 또한 품질 수준을 두가지(5,8${\mu}m$)로 나누었다. 그 결과 peel test 기준에 의거한 불량, 양품을 정량적인 수치(인장강도)로 판별할 수 있었으며, 솔더 조인트의 파괴모드별 인장강도를 구분 할 수 있었다.

  • PDF

A study on Requirements of the Test Flight Safety for a 350m Unmanned Airship (50m급 무인비행선 시험비행 안전성 요구사항에 관한 연구)

  • Jeong, B.G.;Shin, D.W.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.12 no.2
    • /
    • pp.1-15
    • /
    • 2004
  • In this study, we analyze technical requirements for a 50m unmanned airship order to assure safety in the test flight operation. The 50m class unmanned airship developed by Airship Group in Korea Aerospace Research Institute(KARI). The 50m class unmanned airship was developed as a scale-down model of 200m class stratosphere unmanned airship. This study reviews specifications and characteristics of 50m class unmanned airship and develops Airworthiness Requirements on the basis of current effective Aviation Act, Airworthiness standards, and relevant international documents. The developed requirements can be applied to the safety assessment of the 200m class stratosphere unmanned airship.

  • PDF

Performance Test of NYSC 1m Telescope by Photometric Observation of M35

  • Kang, Wonseok;Kim, Taewoo;Kwon, Sun-gill;Lee, Sang-Gak
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.63.3-63.3
    • /
    • 2016
  • NYSC 1m telescope is completely assembled now, and equipped with FLI PL-16803 4k CCD and Shelyak eShel spectrograph (R~10,000) on optical system of f/8. From 12th Jan 2016, optical system alignment and test observations have been performed. We present the result of M35 photometric observation for the performance test of the 1m telescope. The photometric observation was carried out for the central part of M35 with the field of view, ${\sim}15^{\prime}.8{\times}15^{\prime}.8$. Standard transformation to the UBVI system was done by the photometric data of M35 in Sung and Bessell(1999).

  • PDF

Specificity of cell-mediated immunity in guinea pigs sensitized with Mycobacterium spp using the leukocyte adherence inhibition test (Leukocyte adherence inhibition test를 이용한 Mycobacterium 속균(屬菌) 감작(感作)기니픽의 세포면역반응(細胞免疫反應)의 특이성(特異性))

  • Park, Seong-kuk;Jun, Moo-hyung;Lee, Hun-jun;Min, Won-gi;Yoon, Yong-dhuk
    • Korean Journal of Veterinary Research
    • /
    • v.29 no.3
    • /
    • pp.283-289
    • /
    • 1989
  • In order to measure in vitro cell mediated immunity in the guinea pigs sensitized with the killed bacilli of Mycobacterium bovis ($AN_5$), M avium (serotype 2), M tuberculosis and M intracellulare (serotype 8), leukocyte adherence inhibition (LAI) test was established using the antigens of purified protein derivatives (PPD) tuberculin. By using LAI test, specificity of cell-mediated immune responses of the guinea pigs inoculated with various Mycobacterium spp was investigated, and comparison between values of LAI and skin test was also made to evaluate the specificity of the newly designed test. The results obtained throughout the experiments were summarized as follows; 1. The optimal concentration of PPD antigens for LAI test was 1 to 2mg per ml of medium. 2. When the leukocytes of guinea pigs sensitized with both M bovis($AN_5$) and M avium (serotype 2) for 2 to 8 weeks were incubated with homologous or heterologous PPD antigens, mean values of LAI test were $61.2{\pm}11.2$ and $65.6{\pm}5.1%$ in homologous PPD antigens respectively, while $30.0{\pm}3.7$ and $32.8{\pm}5.7%$ in heteNlogous PPD antigens, showing the prominently high value of LAI in the homologous syst,em (p<0.01). 3. When the leukocytes of guinea pigs sensitized with both M tuberculosis and M intracellulare (serotype 8) for 2 to 8 weeks were incubated with homologous and heterologous PPD antigens, mean values of LAI test were $67.9{\pm}2.9$ and $66.9{\pm}5.0%$ in homologous PPD antigens, while $27.4{\pm}7.4$ and $24.4{\pm}7.1%$ in heterologous PPD antigens, showing the prominently high value of LAI in the homologous system (p<0.01). 4. Comparing with the specificity of LAI and skin tests on the basis of the value obtained from the homologous system, deviation of reaction was revealed to be 49.5 to 100.2 in LAI test, and -15.9 to 52.0 in skin test.

  • PDF

Glomerular Filtration Rate Test Methods and Guidelines (Glomerular Filtration Rate 검사방법 및 가이드라인)

  • Park, Min-Ho;Lee, Ha-Young;Ryu, Hwa-Jin;Yoo, Tae-Min;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.97-100
    • /
    • 2018
  • Purpose The glomerular filtration rate (GFR) test is an important indicator of glomerular filtration and has been used to test renal function and the extent of its function. The GFR test is performed by intravenous injection of radioactive medicines made of $^{51}Cr$-EDTA, and blood concentration is measured by taking blood according to the elapsed time. also, PET-CT, bone scan, transfusion and so on will affect the outcome. Therefore, we will improve the quality of the test by providing guidelines for the GFR test for more accurate testing. Materials and Methods 5 mL of physiological saline solution and 2 mL of $^{51}Cr$-EDTA solution are used to make 5 mL of the radiopharmaceutical solution to be injected into the patient. First, the syringe weight is measured before the injection, and then the radioactive medicine is injected into the patient's vein and the syringe weight is measured after the injection. Blood sampling is performed twice in total. In adults, blood is collected 3 hours / 5 hours after injection and in children 2 hours / 5 hours after injection. The blood sample is centrifuged at 3300 rpm for 5 minutes. Standard solution is prepared by filling diluent water up to the scale indicated in the 200-mL volumetric flask, discarding $500{\mu}L$, injecting $500{\mu}L$ of GFR reagent and mixing well. $500{\mu}L$ each of the standard solution is dispensed into two test tubes, and $500{\mu}L$ of each of the plasma samples collected in time is dispensed into two test tubes and measured with a Cobra Counter. Results At present, the reference range applied in this study is $119.5{\pm}30.3ml/min/1.73m2$ for males and $125.2{\pm}28.2ml/min/1.73m^2$ for females. Conclusion The GFR test is conducted using radioactive medical products. GFR testing is performed as a scheduled test, but PET-CT, dialysis and transfusion, which may affect GFR testing, may be scheduled during GFR testing. Therefore, we could get accurate GFR test results by notifying the ward and department beforehand when booking.

An Experimental Study on the Heave Characteristics of DCM Heaving Soil (DCM 부상토의 융기 특성에 대한 실험적 연구)

  • Eonsang Park;Seungdo Park
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.2
    • /
    • pp.5-12
    • /
    • 2023
  • In this study, the amount of heaving soil and the heave characteristics of the heaving soil generated at the actual site were quantitatively analyzed through DCM laboratory test construction. By reproducing a series of construction processes of the DCM method in a large-scale soil tank close to the actual site, the amount of heaving soil was predicted and the elevation characteristics such as elevation, diffusion range, diffusion angle and amount of elevation of the heaving soil were evaluated. As a result of the laboratory test construction, the actual elevation in terms of similarity within the DCM improvement section is 0~8.18m, and an average of 3.50m is observed. The actual diffusion range of the heaving soil converted to the similarity ratio is distributed from 28.0 to 38.0m on the left and right sides of the improvement section. The total amount of heaving soil calculated by the SUFFER program based on the results of the laboratory test construction is 19,901m3. Compared with the injected slurry amount of 16,992m3, the amount of heave compared to the injected amount is analyzed as 85.4%. The diffusion angle of DCM heaving soil, which analyzed the results of DCM laboratory test construction with the SUFFER program, is measured to be 30.0~38.0° at a depth of 50.0m, and is evaluated as an average of 34.0°. On the other hand, based on the DCM laboratory test construction and the analysis results using the program performed in this study, the amount of heaving soil at the DCM depths of 40.0m and 60.0m is predicted.

RESULTS OF THERMAL CREEP TEST ON HIGHLY IRRADIATED ZIRLO

  • Quecedo, M.;Lloret, M.;Conde, J.M.;Alejano, C.;Gago, J.A.;Fernandez, F.J.
    • Nuclear Engineering and Technology
    • /
    • v.41 no.2
    • /
    • pp.179-186
    • /
    • 2009
  • This paper presents a thermal creep test under internal pressure and post-test characterization performed on high burnup (68 MWd/kgU) ZIRLO. This research has been done by the CSN, ENRESA, and ENUSA in order to investigate the behavior of advanced cladding materials in contemporary PWRs at higher burnup under dry cask storage conditions. Also, to investigate the hydride reorientation, the cool-down of the samples after the test has been done in a coordinated manner with the internal pressure. The creep results obtained are consistent with the expected behavior from reference CWSR material, Zr-4. During the test, the material retained significant ductility: one specimen leaked during the test at an engineering strain of the tube section of 17%; remarkably, the crack closed due to de-pressurization. Although significant hydride reorientation occurred during the cool-down under pressure, no specimen failed during the cool-down.

Robust inference with order constraint in microarray study

  • Kang, Joonsung
    • Communications for Statistical Applications and Methods
    • /
    • v.25 no.5
    • /
    • pp.559-568
    • /
    • 2018
  • Gene classification can involve complex order-restricted inference. Examining gene expression pattern across groups with order-restriction makes standard statistical inference ineffective and thus, requires different methods. For this problem, Roy's union-intersection principle has some merit. The M-estimator adjusting for outlier arrays in a microarray study produces a robust test statistic with distribution-insensitive clustering of genes. The M-estimator in conjunction with a union-intersection principle provides a nonstandard robust procedure. By exact permutation distribution theory, a conditionally distribution-free test based on the proposed test statistic generates corresponding p-values in a small sample size setup. We apply a false discovery rate (FDR) as a multiple testing procedure to p-values in simulated data and real microarray data. FDR procedure for proposed test statistics controls the FDR at all levels of ${\alpha}$ and ${\pi}_0$ (the proportion of true null); however, the FDR procedure for test statistics based upon normal theory (ANOVA) fails to control FDR.