A Developing Tendency of Liquefied Natural Gas Carriers (액화천연가스 운반선(LNGC)의 발전 추세)

  • Lee, Dong-Sup
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.3
    • /
    • pp.269-274
    • /
    • 2009
  • Recently, the construction of Liquefied Natural Gas Carriers(LNGC) is being promoted larger and larger depending on long voyage. In 1950 years, $5,000m^3$ class of LNGC had been changed to $71,500m^3$ class in 1973. and to $210,000-266,000m^3$ class in 2007. Especially, the system of main engines and cargo control, Re-liquefaction of natural gases have become possible in LNGC. This research deals with the LNG projects, world markets of energy and developing tendency of liquefied natural gas carriers.

  • PDF

A Study on the Safe Maneuvering Technology Based on the Thermal Calculation of Membrane Type LNG Carrier (멤브레인형 LNGC의 열계산에 기초한 안전운항기술에 관한 연구)

  • Jin, Chang-Fu;Kim, Kyung-Kuen;Oh, Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1192-1200
    • /
    • 2008
  • This paper is concerned with the thermal design of the $138,000m^3$ class membrane type LNGC. To predict the temperature distribution, BOG and BOR, 3-dimensional numerical calculation was carried-out for the quarter of No.3 LNG tank. These sequence analyses were performed under the standard conditions of IMO ship design condition, USCG ship design condition and the Korean flag LNGC's route condition according to the 6-voyage modes. As the results, temperature behavior, heat flux, total penetrating heat, BOG and BOR were obtained, and those were compared with the maneuvering results considering the real temperature variation of air and sea water temperature at noon time. For securing the safety of LNGC during the ballast voyage, optimum control patterns of pressure and temperature in LNG tank is suggested in this paper.

Software-In-the-Loop based Power Management System Modeling & Simulation for a Liquefied Natural Gas Carrier (SIL 기반 액화천연가스운반선 전력관리시스템의 모델링 및 시뮬레이션)

  • Lee, Kwangkook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.6
    • /
    • pp.1218-1224
    • /
    • 2017
  • With the increasing risk in building liquefied natural gas carriers (LNGC), pre-simulation of various scenarios is required for system integration and safe operation. In particular, the power management system (PMS) is an important part of the LNGC; it works in tight integration with the power control systems to achieve the desired performance and safety. To verify and improve unpredicted errors, we implemented a simulation model of power generation and consumption for testing PMS based on software-in-the-loop (SIL) method. To control and verify the PMS, numeric and physical simulation modeling was undertaken utilizing MATLAB/Simulink. In addition, the simulation model was verified with a load sharing test scenario for a sea trial. This simulation allows shipbuilders to participate in new value-added markets such as commissioning, installation, operation, and maintenance.

Experimental Study on Damping of Side-by-Side Moored Vessels (병렬계류된 선박의 감쇠력에 관한 실험연구)

  • KIM JIN-HA;HONG SA-YOUNG;KIM YOUNC-SIK;KIM DEOK-SU;KIM YOUNG-SU
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.160-165
    • /
    • 2004
  • Low-frequency damping characteristics of side-by-side moored LNG-FPSO and LNGC arc investigated through a series of free decay model tests in calm water and under wind load condition. It is shown that low frequency damping of LNGC changes dramatically, sway damping increases more than six times for 4m distance condition while it decreases by $30\%$ for 20m distance compared with a single LNGC case. Simulation using the experimental data enhances the results, which demonstrates the necessity of experimental low-frequency damping coefficients for simulation of side-by-side vessels motion behavior.

  • PDF

A Study on the Thermal Analysis of Spray Cooling for the Membrane Type LNGC During the Cool-Down Period (급냉각기간에서 멤브레인형 LNGC의 분무냉각 열해석에 관한 연구)

  • Lee, Jung-Hye;Kim, Kyung-Kue;Ro, Sung-Tack;Chung, Han-Shik;Kim, Seong-Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.1
    • /
    • pp.125-134
    • /
    • 2003
  • The present paper is concerned to the thermal analysis during the cool-down period of 138,000 m$^3$class GTT MARK-III membrane type LNG carrier servicing with LNG from the Middle East to Korea. It is the cool-down period that cools the insulation wall and the gas in LNG tank to avoid the thermal shock as the start of loading of -162$^{\circ}C$ LNG. For six hours of the standard cool-down period, the temperature of NG falls down from -4$0^{\circ}C$ to -13$0^{\circ}C$ and especially the mean temperature of the 1st barrier in the top side insulation wall falls down from -38.38$^{\circ}C$ to -122.42$^{\circ}C$ in case of IMO design condition. By the 3-D numerical calculation about the cargo tank and the cofferdam, the temperature variation in hulls and insulations is precisely predicted in this paper. And the mean temperature variation of gas is calculated as the function of the spraying rate by the heat balance model during the cool-down period.

Thermal Analysis for the GT-96 Membrane Type LNGC during the Cool-down Period (GT-96 멤브레인형 LNGC의 급냉기간에서의 열해석)

  • Lee, Jung-Hye;Choi, Hyun-Kue;Choi, Soon-Ho;Oh, Cheol;Kim, Myoung-Hwan;Kim, Kyung-Kun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1346-1351
    • /
    • 2004
  • This study is concerned with the thermal analysis during the cool-down period of 135,000 $m^3$ class GT-96 membrane type LNG carrier under IMO design condition. The cool-down is performed to cool the insulation wall and the natural gas in cargo tank for six hours to avoid the thermal shock at the start of loading of $-163^{\circ}C$ LNG. During the cool-down period, the spraying rate for the NG cooling decreases as the temperature of NG falls clown from $-40^{\circ}C$ to $-130^{\circ}C$ and the spraying rate for the insulation wall cooling increases as the temperature gradient of the insulation wall is large. It was confirmed that there existed the largest temperature decrease at the 1 st barrier and 1st insulation, which are among the insulation wall, especially in the top side of the insulation wall. By the 3-D numerical calculation about the cargo tank and the cofferdam during the cool-down period, the temperature variation in hulls and insulations is precisely predicted.

  • PDF

Dynamic Response of Polyurethane Foam with Density and Temperature Effects (폴리우레탄 폼의 동적 응답에 미치는 밀도 및 온도의 영향)

  • Hwang, Byeong-Kwan;Kim, Jeong-Hyun;Kim, Jeong-Dae;Lee, Jae-Myung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.4
    • /
    • pp.291-297
    • /
    • 2019
  • Polyurethane foam is the most efficient, high-performance insulation material, used for liquefied natural gas carrier (LNGC) insulation. Because LNGC is exposed to sloshing impact load due to ship motion of 6 degrees of freedom, polyurethane foam should be sufficient dynamic properties. The dynamic properties of these polyurethane foam depends on temperature and density. Therefore, this study investigates the dynamic response of polyurethane foam for various temperature($25^{\circ}C$, $-70^{\circ}C$, $-163^{\circ}C$) and density($90kg/m^3$, $113kg/m^3$, $134kg/m^3$, $150kg/m^3$) under drop impact test with impact energy of 20J, 50J, and 80J. For dynamic response was evaluated in terms of peak force, peak displacement, absorb energy, and the mechanical property with minimized density effects. The results show the effect of temperature and density on the polyurethane foam material for the dynamic response.

Development of Newly Formulated High-strength Wash Primer for Membrane LNG Carrier (멤브레인형 LNG 운반선용 고강도 워시프라이머 개발)

  • Song, Eun-Ha;Lee, Sung-Kyun;Chung, Mong-Kyu;Baek, Kwang-Ki
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2007.09a
    • /
    • pp.48-56
    • /
    • 2007
  • Wash primer was applied to cargo tank of Membrane-LNG Carrier (M-LNGC) for corrosion resistance and high bond-strength with the mastic. However, a lack of bond-strength verification at high thickness wash primer coating resulted in strict coating thickness control. Therefore wash primer was controlled below DFT(Dry Film Thickness) $30{\mu}m$. In order to develop the wash primer satisfying GTT (GAZ TRANSPORTAION TECHNIGAZ) standard even at high thickness, we evaluated coating properties such as wash primer/mastic bond-strength, corrosion resistance, as well as workability for the newly formulated wash primer materials. The newly formulated wash primer had high bonding-strength to mastic even at high thickness and had proper corrosion resistance and workability suitable to yard condition.

  • PDF

The New Trend of Propulsion and BOG Handling System from LNGCs (최근 LNG선의 추진 및 BOG 처리장치의 동향)

  • Kim, M.E.;Lee, K.W.;Lee, Y.H.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.940-945
    • /
    • 2005
  • In recent years, the LNGC fleet is expanded unprecedentedly. Ship's owners and shipbuilders are focusing on technology and reliability of new propulsion system from economical, environmental and safety angles. This paper give describes the new trend of propulsion system and boil off gas handling system from LNG carriers.

  • PDF

The BOG Handling System for LNG Carrier (LNG운반선의 BOG 처리설비)

  • Kim, M.E.;Kim, Y.T.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.557-561
    • /
    • 2005
  • In recent years, the LNGC fleet is expanded unprecedentedly. Ship's owners and shipbuilders are focusing on the idea how they choose the BOG handling system in economical, environmental and safety angles. This paper introduces general information for that and gives technical matters briefly.

  • PDF