• Title/Summary/Keyword: M-ICP

Search Result 530, Processing Time 0.026 seconds

Gold Recovery Using Inherently Conducting Polymer Coated Textiles

  • Tsekouras, George;Ralph, Stephen F.;Price, William E.;Wallace, Gordon G.
    • Fibers and Polymers
    • /
    • v.5 no.1
    • /
    • pp.1-5
    • /
    • 2004
  • The ability of inherently conducting polymer (ICP) coated textiles to recover gold metal from aqueous solutions containing $[AuCl_4]^-$ was investigated. Nylon-lycra, nylon, acrylic, polyester and cotton were coated with a layer of polypyrrole (PPy) doped with 1,5-naphthalenedisulfonic acid (NDSA), 2-anthraquinonesulfonic acid (AQSA) or p-toluenesulfonic acid (pTS). Textiles coated with polyaniline (PAn) doped with chloride were also used. The highest gold capacity was displayed by PPy/NDSA/nylon-lycra, which exhibited a capacity of 115 mgAu/g coated textile, or 9700 mgAu/g polymer. Varying the underlying textile substrate or the ICP coating had a major effect on the gold capacity of the composites. Several ICP coated textiles recovered more than 90 % of the gold initially present in solutions containing 10 ppm $[AuCl_4]^-$ and 0.1 M HCl in less than 1 min. Both PPy/NDSA/nylon-lycra and PAn/Cl/nylon-lycra recovered approximately 60 % of the gold and none of the iron present in a solution containing 1 ppm $[AuCl_4]^-$, 1000 ppm $Fe^{3+}$ and 0.1 M HCl. The spontaneous and sustained recovery of gold metal from aqueous solutions containing $[AuCl_4]^-$ using ICP coated textiles has good prospects as a potential future technology.

Determination of Ni, Cr, Mo in Low Alloy Steel Reference Materials by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry (동위원소희석 유도결합플라스마질량분석법에 의한 저 합금강 표준시료중의 Ni, Cr, Mo의 분석)

  • Suh, Jungkee;Woo, Jinchoon;Min, Hyungsik;Yim, Myeongcheul
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.82-89
    • /
    • 2003
  • Isotope dilution mass spectrometry (IDMS) was applied to the determination of Ni, Cr, Mo in low alloy steel reference materials. The Mo isotope ratio measurement was performed by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP/MS) using ammonia as a reaction cell gas. In the case of Ni and Cr measurement, all data were obtained at medium resolution mode (m/${\Delta}m=3000$) of double focusing sector field high resolution inductively coupled plasma mass spectrometry (HR-ICP/MS). For the method validation of the technique was assessed using the certified reference materials such as NIST SRM 361, NIST SRM 362, NIST SRM 363, NIST SRM 364, NIST SRM 36b. This method was applied to the determination of Ni, Cr and Mo in low alloy steel sample (CCQM-P25) provided by NMIJ for international comparison study.

Determination of Heavy Metals Concentrations in Urban Air using ICP Method : in the Area of Chung-Ang University (ICP법에 의한 도시대기중 중금속 농도 측정: 중앙대학교를 중심으로)

  • 손동헌;신혜숙;정성윤;정원태
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.222-229
    • /
    • 1993
  • Total suspended particles in the atmosphere were collected on the quartz fiber filters using an ANdersen Hi-volume air sampler from March 1989 to October 1989 and from June 1990 to February 1991, at Chung-Ang University in Seoul. A total amount of eight heavy metals (Cr, Zn, Cd, Pb, Fe, V, Ti, Mn) in total suspended particles were determined by ICP spectrophotometer. The annual arithmetic mean concentration of total suspended particle was 162.3$\mug/m^3$ and eight metals(Cr, Zn, Cd, Pb, Fe, V, Ti, Mn) were 11.6, 609.2, 3.5, 337.1, 2739.5, 15.1, 89.4 and 100.5ng/$m^3$, respectively. The concentration of total suspended particle was highest in the spring(343.7$\mug/m^3$) and lowest in the summer(91.8$\mug/m^3$). These heavy metals were distinguished into two groups in terms of their particle size distribution. The contents of first-group heavy metals (Fe, Ti, Mn) were increased in accordance with the growth of the particle size. The contents of the second-group ones such as Pb, Cd, V, and Zn, on the contrary, came to increase according as the particle size reduced. Statistical analysis indicated that there was a correlation between total suspended particle and Fe in coarse particles, and between total Suspended Particle and Zn, Pb in fine particle.

  • PDF

Determination of Rare Earth Elements by Inductively Coupled Plasma Mass Spectrometry with Introduction of Organic Phase Using Ultrasonic Nebulizer (초음파 분무기를 이용한 유기상의 주입에 의한 희토류 원소의 유도결합 플라스마 질량분석법적 정량)

  • Lee, Sang Hak;Son, Bum Mok
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.127-134
    • /
    • 2002
  • Analytical method to determine rare earth elements which were extracted to organic phase by inductively coupled plasma mass spectrometry(ICP-MS) was investigated. Organic phase which had extracted rare earth elements was directly aspirated into ICP-MS by ultrasonic nebulizer(USN) in order to reduce solvent load to the plasma. Then, the count rate increased when MIBK(methyl isobutyl ketone) was added to EtOH(ethanol) but decreased when 0.03 M HEH(2-ethylhexyl-2-ethylhexyl phosphonic acid, $P_{507}$, PC88A) was added to solvent which mixed MIBK with EtOH. The optimal temperatures of desolvation system were -10 $^{\circ}C$ for the condenser and 150 $^{\circ}C$ for the heating tube. The optimal nebulizer flow rate which gave maximum count rate and minimum reflect power was 0.7 L/min. The optimal pH and extraction time were 4.3 and 10 min for MIBK-0.03 M HEH system. Detection limits which were obtained through calibration curves at the range of 0.2 ${\sim}$ 20 ng/mL were 0.02 ${\sim}$ 0.05 ng/mL under the optimal experimental conditions.

A Correlational Study between Auditory Evoked Potential and Subdural Hematoma for the Diveloprnent of a Noninvasive ICP Monitoring System (비침습적 뇌내압 측정 시스템의 개발을 위한 청각유발전위와 경막혈종간의 상관관계 분석에 관한 연구)

  • ;C.S. Lessard
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.167-174
    • /
    • 1995
  • Development of a noninvasive intensive care system calls for the use of evoked potentials (EPs) as a means of diagnosing traumatic head-injured patients. The experiment entails surgically placing two subarachnoid bolts and a subdural balloon through the skull to simulate a subdural hematoma. Using various levels of intracranial pressure (ICP) and/or different sizes of balloons, auditory evoked potentials (AEPs) were recorded from a rabbit. Six positive peak latencies ($P_1 - P_6$) and five negative peak latencies ($N_l- N_5$) were extracted from an averaged AEP waveform. Multiple regression analyses were performed for determining. a relationship between the ICP and AEP peak latencies. The results indicate that a major correlation of ch, mges on AEP peak latencies is due to mechanical forces of a mass (inflated balloon simulating a hematoma) in the distortion of the brain matter rather than increased ICP itself.

  • PDF

Fabrication of a silicon pressure sensor for measuring low pressure using ICP-RIE (ICP-RIE를 이용한 저압용 실리콘 압력센서 제작)

  • Lee, Young-Tae;Takao, Hidekuni;Ishida, Makoto
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.126-131
    • /
    • 2007
  • In this paper, we fabricated piezoresistive pressure sensor with dry etching technology which used ICP-RIE (inductively coupled plasma reactive ion etching) and etching delay technology which used SOI (silicon-on-insulator). Structure of the fabricated pressure sensor shows a square diaphragm connected to a frame which was vertically fabricated by dry etching process and a single-element four-terminal gauge arranged at diaphragm edge. Sensitivity of the fabricated sensor was about 3.5 mV/V kPa at 1 kPa full-scale. Measurable resolution of the sensor was not exceeding 20 Pa. The nonlinearity of the fabricated pressure sensor was less than 0.5 %F.S.O. at 1 kPa full-scale.

Dry Etching Characteristics of BLT Thin Film (BLT 박막의 건식 식각 특성에 관한 연구)

  • Kim, Dong-Pyo;Kim, Chang-Il
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.309-311
    • /
    • 2003
  • The effects of etch parameters on dry etching of BLT thin films were investigated with ICP etch system in $Cl_2$/Ar and $BCl_2/Cl_2$/Ar gas. The etch rate and etch selectivity of BLT films were examined as a function of gas concentration, ICP power, bias power, and pressure. The maximum etch rates of 191.1 nm/min was obtained at the mixed etch condition of $BCl_3(20%)/Cl_2$/Ar, 700 W ICP RF power, 12 mTorr pressure and 400 W substrate RF power. As ICP power and rf power increased, the etch rate of BLT increased. As pressure increased, the etch rate of BLT decreased. The changes of radicals in both $Cl_2$/Ar and $BCl_3/Cl_2$/Ar plasma were measured with using optical emission spectroscopy (OES).

  • PDF

Ultra-sensitive Determination of Salinomycin in Serum Using ICP-MS with Nanoparticles

  • Cho, H.K.;Lim, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.11
    • /
    • pp.3195-3198
    • /
    • 2014
  • An ultra-sensitive detection method for small molecules such as antibiotics was developed using ICP-MS with magnetic and $TiO_2$ nanoparticles. Since most of the antibiotics are too small to employ a sandwich-type extraction through an immunoreaction, a non-specific platform was employed, in which the target was extracted by magnetic separation, followed by tagging with $TiO_2$ nanoparticles of 11.2 nm for ICP-MS measurement. The detection limit for salinomycin obtained from spiked serum samples was $0.4ag\;mL^{-1}$ (${\pm}10.3%$), which was about $1.5{\times}10^6$ times lower than that of LC-MS/MS and about $1.2{\times}10^{11}$ times better than that of ELISA. Such an excellent sensitivity enabled us to study the toxicity of antibiotics exposed to human beings by determining them in serum.

전북대학교 소재공정용 200 kW ICP(RF) 플라즈마 발생 장치 구축

  • Lee, Mi-Yeon;Kim, Jeong-Su;Choe, Chae-Hong;Kim, Min-Ho;Seo, Jun-Ho;Hong, Bong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.538-538
    • /
    • 2012
  • 전북대학교 고온 플라즈마 응용 연구 센터는 교육과학기술부 기초연구사업 중 고가연구장비 구축사업의 일환으로 고부가가치 재료 연구 및 시험생산이 가능한 소재공정용 200kW ICP(RF) 플라즈마 발생장치를 구축하고 있다. 200 kW급 ICP (RF)형 플라즈마 발생장치는 수~수십 um 크기의 금속, 세라믹 등 고융점 원료분말 등을 수~수십 um 크기의 금속, 세라믹 등 고융점 원료 분말을 순간적으로 용해, 기화 및 분해시키고 이들 기화 또는 분해된 증기를 급랭시키는 과정에서 대량으로 초미분($<1{\mu}m$)을 합성하는 RF 플라즈마 분말 합성 시스템으로 시간당 1 kg 이상의 나노 분말의 제조가 가능하도록 설계 제작된 생산 지원용 대형 ICP(RF) 플라즈마 장치이다.

  • PDF

Applications of ICP-MS to the Determination of Trace Np and Pu in Environmental Samples with Extraction Chromatography

  • Ji, Yanqin;Li, Jinying;Luo, Shanggeng
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.182-190
    • /
    • 2004
  • An unique extraction chromatographic column (TOA: Tri-n-octylamine on Teflon powder) with a two-stage sample loading was prepared to separate Np and Pu from the environmental matrix. Np and Pu were efficiently retained in 4 M $HNO_3$ medium on the column and easily eluted with 0.02 M oxalic acid in 0.16 M HNO$_3$at $95^{\circ}C$. The separated solutions were free from most of the matrix elements and were aspirated into the ICP-MS directly. The decontamination factor for 238U is more than 104. The instrumental detection limit for 237Np was 0.46 pg mL-l ($1.2{\times}10_{-5}$Bq mL-l), and for 239Pu was 0.48 pg mL-l ($1.1{\times}10_{-3}$ Bq mL-l). The feasibility for the determination of both elements was proved by analysing IAEA-135 reference samples, the measured values agreed with the recommended reference value.

  • PDF