The Clinical Utility of Rectal Gas Distension F-18 FDG PET/CT (공기주입 직장 확장 F-18 FDG PET/CT의 임상적 유용성)

  • Kim, Jin-Suk;Lim, Seok-Tae;Jeong, Young-Jin;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.565-571
    • /
    • 2009
  • Purpose: The aim of this study was to evaluate the clinical value of rectal gas distension F-18 FDG PET/CT imaging for the differentiation of the rectal focal uptake lesions. Materials and Methods: Twenty four patients (M:F=11:13, Age $62.8{\pm}12.4$ years) underwent rectal gas distension F-18 FDG PET/CT, prospectively: initial image at 50-60 min after the intravenous injection of F-18 FDG and rectal distension image after the infusion of air through the anus. Focally increased uptake lesions on initial images but disappeared on rectal distension images defined a physiological uptake. For the differential evaluation of persistent focal uptake lesions on rectal distension images, colonoscopy and histopathologic examination were performed. Results: Among the 24 patients, 27 lesions of focal rectal uptake were detected on initial images of F-18 FDG PET/CT. Of these, 7 lesions were able to judge with physiological uptake because the focal increased uptake disappeared from rectal distension image. Remaining 3 lesions were non-rectal lesions (2 lesions: rectovesical space, 1 lesion: uterine myoma). Among 17 lesions which was showed persistent increased uptake in rectal distension image, 15 lesions were confirmed as the malignant tumor (SUVmax=$15.9{\pm}6.8$) and 2 lesions were confirmed as the benign lesions including adenoma and inflammatory disease. Conclusion: The rectal distension F-18 FDG PET/CT imaging could be an important noninvasive method for the differentiation of malignant and benign focal rectal uptake lesions including physiologic uptake.

Modelling of Fault Deformation Induced by Fluid Injection using Hydro-Mechanical Coupled 3D Particle Flow Code: DECOVALEX-2019 Task B (수리역학적연계 3차원 입자유동코드를 사용한 유체주입에 의한 단층변형 모델링: DECOVALEX-2019 Task B)

  • Yoon, Jeoung Seok;Zhou, Jian
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.320-334
    • /
    • 2020
  • This study presents an application of hydro-mechanical coupled Particle Flow Code 3D (PFC3D) to simulation of fluid injection induced fault slip experiment conducted in Mont Terri Switzerland as a part of a task in an international research project DECOVALEX-2019. We also aimed as identifying the current limitations of the modelling method and issues for further development. A fluid flow algorithm was developed and implemented in a 3D pore-pipe network model in a 3D bonded particle assembly using PFC3D v5, and was applied to Mont Terri Step 2 minor fault activation experiment. The simulated results showed that the injected fluid migrates through the permeable fault zone and induces fault deformation, demonstrating a full hydro-mechanical coupled behavior. The simulated results were, however, partially matching with the field measurement. The simulated pressure build-up at the monitoring location showed linear and progressive increase, whereas the field measurement showed an abrupt increase associated with the fault slip We conclude that such difference between the modelling and the field test is due to the structure of the fault in the model which was represented as a combination of damage zone and core fractures. The modelled fault is likely larger in size than the real fault in Mont Terri site. Therefore, the modelled fault allows several path ways of fluid flow from the injection location to the pressure monitoring location, leading to smooth pressure build-up at the monitoring location while the injection pressure increases, and an early start of pressure decay even before the injection pressure reaches the maximum. We also conclude that the clay filling in the real fault could have acted as a fluid barrier which may have resulted in formation of fluid over-pressurization locally in the fault. Unlike the pressure result, the simulated fault deformations were matching with the field measurements. A better way of modelling a heterogeneous clay-filled fault structure with a narrow zone should be studied further to improve the applicability of the modelling method to fluid injection induced fault activation.

Boulangerite from the Janggun Mine, Republic of Korea; Contributions to the Knowledge of Ore-Forming Minerals in the Janggun Lead-Zinc-Silver Ores (2) (한국·장군광산산 보울란저라이트에 대하여; 장군 연·아연·은 구성광물의 지식에 대한 기여 (2))

  • Lee, Hyun Koo;Imai, Naoya
    • Economic and Environmental Geology
    • /
    • v.26 no.2
    • /
    • pp.129-134
    • /
    • 1993
  • At the Janggun mine, boulangerite usually occurs as needles or irregularly-shaped grains, up to $500{{\mu}m}$ in longer dimensions, closely associated with galena, minerals of a tetrahedrite-freibergite series and bournonite in the peripheries of South A and B orebodies and the zone of manganoan carbonates surrounding them. In some places, especially at the top of South B orebody, it occures as "feather ore" consisting of its fine needles or "hairs" in small drusy cavities together with fine-grained euhedral galena, pyrite, manganoan carbonates, quartz, etc. In reflected light, it is bluish grey in colour exhibiting moderate bireflectance and is strongly anisotropic without any internal reflections. Reflectance in air is $R_{max}=43.2$, $R_{min}=35.7$ percent at wavelength of 580 nm, and VHN: $146-173\;kg/mm^2$ at a 50 g-load. The chemical composition on the average from 23 complete spot analyses by electron microprobe is, Pb 56.1, Sb 25.1, S 18.5, Total 99.6 (all in weight percent); the corresponding chemical formula calculated on the basis of S=11 is; $Pb_{5.16}Sb_{3.93}S_{11.0}$ which fulfils approximately the ideal formula $Pb_5Sb_4S_{11}$. The strongest reflections on the X-ray diffraction pattern are; $3.73\;{\AA}\;(10)$, $3.22\;{\AA}\;(5)$, $3.03\;{\AA}\;(4)$ and $2.82\;{\AA}\;(5)$ and the pattern is in harmonic with space group $C^5_{2h}-P2_1/a$. From the textural evidence of the microscopic observations, the mineral is considered to have been formed at the latest stage of hydrothermal lead-zinc-silver mineralization.

  • PDF

Studies on the Physico-Chemical Characteristics of Different Casing Materials Affecting Mycelial Growth and Yield of Cultivated Mushroom, Agaricus bisporus (Lange) Sing. (양송이의 균사생장(菌絲生長) 및 자실체(子寶體) 수량(收量)에 미치는 복토재료(覆土材料)의 이화학적(理化學的) 성질(性質)에 관(關)한 연구(硏究))

  • Kim, Dong-Soo
    • The Korean Journal of Mycology
    • /
    • v.3 no.1
    • /
    • pp.1-19
    • /
    • 1975
  • Since the importance of casing in fruit body formation of Agaricus bisporus has been emphasized, physico-chemical characteristics of casing materials were discussed by many workers and a mixture of peat and mineral soil as proper casing material has been adopted in many of mushroom growing countries. Because of limited resources of peat in Korea, it is necessary to find practical performance and substitutional materials for casing. The effect of casing on mycelial growth and mushroom yield of A. bisporus varied with materials, its combination and practices etc. The experiments to be discussed in this paper are concerned with pH and Ca of casing material which influence A bisporus, and changes of physico-chemical characteristics with mixing ratio of casing materials and its effect on A. bisporus. The optimum range of moisture content of each material, management of watering and application of physico-chemical characteristics casing materials was also investigated and re-use of weathered spent compost for casing material was described. 1. The effect of calcium on mycelial growth of A. bisporus at various pH in Halbschalentest showed different results with calcium sources. Best results were obtained around neutrality and fresh weight of fruit bodies grown in the range of pH 7 to 8 was highest among the tested levels. 2. Available moisture, pore space, organic matter, cation exchangeable capacity and exchangeable cation was increased by an increase of mixing ratio of peat in casing materials, while an adverse effect was obtained by addition of sand. 3. Mycelial growth on clay loam was more rapid at a lower bulk density of 0.75g/cc and at 20% moisture content on a dry weight basis at the same bulk density. 4. Mixing ratio of casing materials, 60 to 80 per cent by volume of peat mixed with 20 to 40 per cent of clay loam produced the highest yield of fresh fruit bodies and sand the lowest. However, per cent of open cap was highest in peat and lowest in sand. 5. Days required for fruit body initiation was shortened in mixtures of peat and clay loam by one to three days compared with other materials and the formation of flushes was clear. 6. The effect of some physico-chemical characteristics of casing materials on the fresh weight of fruit bodies were estimated by a multiple regression equation; Y=-923.86+$8.18X_1+8.04X_2+7.90X_3+0.12X_4+2.03X_5-0.82X_6-0.54X_7$ where $X_1,X_2,X_3,X_4,X_5,X_6,X_7$ are sand, silt, clay, available moistuer, porosity, organic matter and exchangeable cation respectively. The productivity of certain casing material could be predicted from this equation. 7. Fresh weight of fruit bodies was positively correlated with porosity exchangeable cation, organic matter, available moisture, silt and clay of materials; while sand was negatively correlated. On the contrary, sand was the unique factor reducing per cent of open cap. 8. Distribution of three phases of high productive casing material was concentrated in the range of 10 to 30 per cent solids, 15 to 30 per cent liquids, and 50 to 60 per cent in air volume. 9. Fresh weight of fruit bodies from peat was not affected with heavy watering but in clay loam and sandy loam severe crop losses occurred. Fresh weight of individual fruit was increased and open caps were decreased with heavy watering but light watering resulted in adverse effects: its effect was especially great in peat. 10. Optimum range of moisture content by weight on a dry basis was different with each casing material. To maintain optimum moisture content concerned with yield of fruit bodies and open cap, sandy loam and peat mixtures required daily watering of 0.6, 0.6 to 1. 2 and 1.2 to 2.4 liters per $3.3m^2$ of bed area, respectively. 11. Maximum yield of fruit body was recorded in the range of pF 2. 0 to 2. 5 of casing materials if organic matter content was below 4.2 per cent and in pF 1. 3 to 1.8 if above 7.1%. 12. pF curve of a certain casing material could be draws from moisture content at various pF values by multiple regression equations provided texture, organic matter and calcium of the casing material are given. Optimum moisture range of the casing materials also could be estimated by the equation. 13. It was possible to improve the phyico-chemical characteristics of clay loam and sandy loam by addition of weathered spent compost although the effect was less than in the case of peat. Fresh weight of fruit bodies wsa increased by addition of weathered spent compost but its effect was not as remarkable as peat. Accordingly, further studies will be required.

  • PDF

Semantic Access Path Generation in Web Information Management (웹 정보의 관리에 있어서 의미적 접근경로의 형성에 관한 연구)

  • Lee, Wookey
    • Journal of the Korea Society of Computer and Information
    • /
    • v.8 no.2
    • /
    • pp.51-56
    • /
    • 2003
  • The structuring of Web information supports a strong user side viewpoint that a user wants his/her own needs on snooping a specific Web site. Not only the depth first algorithm or the breadth-first algorithm, but also the Web information is abstracted to a hierarchical structure. A prototype system is suggested in order to visualize and to represent a semantic significance. As a motivating example, the Web test site is suggested and analyzed with respect to several keywords. As a future research, the Web site model should be extended to the whole WWW and an accurate assessment function needs to be devised by which several suggested models should be evaluated.

  • PDF

A Study on the Bed Climate and the Physiological Responses in Sleep. - On Ondol Environment - (수면시 침상기후와 인체생리반응에 관한 연구 -온돌환경을 중심으로-)

  • Kim Myung Ju;Choi Jeong Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.2 s.38
    • /
    • pp.77-87
    • /
    • 1991
  • The purpose of this study were to investigate the bed climate and the physiological responses in sleep on the traditional Korean floor heating system called Ondol. Ondol has been the most widely used heating system in Korea, yet there has been a no systematic studies examined its environmental effects on human body. Experimental room was constructed to match the typical thermal environment of Ondol. (floor surface temperature; $32\~33^{\circ}C$, air temperature; $22.5{\pm}1.0^{\circ}C$, relative humidity; $64.0{\pm}4.0\%$RH, air velocity; 0.25 m/sec.) Three different combinations of bedclothes were chosen for the experiment based on the study results showing that they were the most widely used types in Korea. Type 1 was the combination of a cotton-padded mattress with a cotton-padded Korean style blanket. Type 2 was a cotton-padded mattress with a cotton-guilted Korean style blanket. Type 3 was a cotton-padded matless with a polyacryl blanket. Thermal resistance of each of these combina-tions in the bedclothes was measured using thermal manikin. Two adult female was chosen for the seven hour sleeping experiment which was known to be the average sleeping hours of Korean adult female. The bed climate was measured with the temperature under the mattress, the surface temper-ature of the mattress, and the air temperature and the relative humidity of the space between the mattress and blanket. The skin temperature, rectal temperature of the subjects and the bed climate were measured eight times, one hour before the experiment and every hour during the experiment. The weight loss and the subjective sensation were measured for the each subjects before and after the experiment. The procedure was repeated twice with two subjects and three types of bedclothes, yielding twelve combinations of results. The results were as follows; 1. With the surface temperature of $32\~33^{\circ}C$ of Ondol, air temperature was $22.5{\pm}1.0^{\circ}C$ with $64.0{\pm}4.0\%$ RH. The bed climates were $39.2{\pm}40.8^{\circ}C$ under the mattress, $35.3\~36.2^{\circ}C$ on the mattress, and $26.9\~32.0^{\circ}C$ with $56.0\~71.3\%$ RH between the mattress and the blanket. 2. Mean skim temperature during sleep was 34.2"C with local skin temperature of $34.0\~35.5^{\circ}C$. The skin temperatures of abdomen, thigh, foot were higher than the other parts of the body. 3. The skin temperature of chest, thigh, leg and back varied significantly according to the combinations of bedclothes. With the cotton-padded blanket, the skin temperature was the highest, while with the cotton-guilted blanket showed lowest. 4. Examining the relationship between the mean skin temperature and the local skin temper-ature, the chest temperature showed the highest correlation with the former. Therefore, the chest temperature can be recommended to represent the skin temperature in measuring the bed climate. 5. The subjective bed climates were $39.0\~40.4^{\circ}C$ under the mattress, $35.2\~35.9^{\circ}C$ on the mattress, $29.8\~31.6^{\circ}C$ with $56.8\~68.4\%$ RH between the mattress and blanket. In sum, from this experiment we not only obtained the reliable value of bed climates on Ondol, but also showed that the bed climates and the physiological responses were affected differently according to the materials of bed clothes.

  • PDF

Swelling and Mechanical Property Change of Shale and Sandstone in Supercritical CO2 (초임계 CO2에 의한 셰일 및 사암의 물성변화 및 스웰링에 관한 연구)

  • Choi, Chae-Soon;Song, Jae-Joon
    • Tunnel and Underground Space
    • /
    • v.22 no.4
    • /
    • pp.266-275
    • /
    • 2012
  • In this study, a method is devised to implement a supercritical $CO_2$ ($scCO_2$) injection environment on a laboratory scale and to investigate the effects of $scCO_2$ on the properties of rock specimens. Specimens of shale and sandstone normally constituting the cap rock and reservoir rock, respectively, were kept in a laboratory reactor chamber with $scCO_2$ for two weeks. From this stage, a chemical reaction between rock surface and the $scCO_2$ was induced. The effect of saline water was also investigated by comparing three conditions ($scCO_2$-rock, $scCO_2-H_2O$-rock and $scCO_2$-brine(1M)-rock). Finally, we checked the changes in the properties before and after the reaction by destructive and nondestructive testing procedures. The swelling of shale was a main concern in this case. The experimental results suggested that $scCO_2$ has a greater effect on the swelling of the shale than pure water and brine. It was also observed that the largest swelling displacement of shale occurred after a reaction with the $H_2O-scCO_2$ solution. The results of a series of the destructive and nondestructive tests indicate that although each of the property changes of the rock differed depending on the reaction conditions, the $H_2O-scCO_2$ solution had the greatest effect. In this study, shale was highly sensitive to the reaction conditions. These results provide fundamental information pertaining to the stability of $CO_2$ storage sites due to physical and chemical reactions between the rocks in these sites and $scCO_2$.

Dynamic Changes of Urban Spatial Structure in Seoul: Focusing on a Relative Office Price Gradient (오피스 가격경사계수를 이용한 서울시 도시공간구조 변화 분석)

  • Ryu, Kang Min;Song, Ki Wook
    • Land and Housing Review
    • /
    • v.12 no.3
    • /
    • pp.11-26
    • /
    • 2021
  • With the increasing demand for office space, there have been questions on how office rent distribution produces a change in the urban spatial structure in Seoul. The purpose of this paper is to investigate a relative price gradient and to present a time-series model that can quantitatively explain the dynamic changes in the urban spatial structure. The analysis was dealt with office rent above 3,306 m2 for the past 10 years from 1Q 2010 to 4Q 2019 within Seoul. A modified repeat sales model was employed. The main findings are briefly summarized as follows. First, according to the estimates of the office price gradient in the three major urban centers of Seoul, the CBD remained at a certain level with little change, while those in the GBD and the YBD continued to increase. This result reveals that the urban form of Seoul has shifted from monocentric to polycentric. This shows that the spatial distribution of companies has gradually accelerated decentralized concentration implying that the business networks have become significant. Second, contrary to small and medium-sized office buildings that have undertaken no change in the gradient, large office buildings have seen an increase in the gradient. The relative price gradients in small and medium-sized buildings were inversely proportional among the CBD, the GBD, and the YBD, implying their heterogeneous submarkets by office rent movements. Presumably, those differences in the submarkets were attributed to investment attraction, industrial competition, and the credit and preference of tenants. The findings are consistent with the hierarchical system identified in the Seoul 2030 Plan as well as the literature about Seoul's urban form. This research claims that the proposed method, based on the modified repeat sales model, is useful in understanding temporal dynamic changes. Moreover, the findings can provide implications for urban growth strategies under rapidly changing market conditions.

In Vitro Development of Bovine Nuclear Transfer Embryos Reconstructed with Fetal Fibroblasts (태아 섬유아세포로 재구성된 핵치환 소 수정란의 체외발달)

  • Koo, D.B.;Choi, Y.H.;Park, J.S.;Kim, H.N.;Kang, Y.K.;Lee, C.S.;Han, Y.M.;Park, H.D.;Lee, K.K.
    • Korean Journal of Animal Reproduction
    • /
    • v.24 no.4
    • /
    • pp.407-417
    • /
    • 2000
  • The present study was to examine effects of various electrical stimulus treatments used for electro-fusion on the preimplantation development of bovine nuclear transfer (NT) embryos with fetal fibroblast cells. Fetal fibroblast cells were isolated from one fetus at day 45 of gestation in Holstein cow, and passaged 3 to 4 times before being transferred into enucleated oocytes. Single fibroblast cells were individually placed into the perivitelline space of enucleated oocytes by using a micromanipulator. At first, the fusion and developmental rates of reconstructed oocytes were compared between different electric stimulation conditions. When fusion of the reconstructed oocyte was induced by different electric pulse periods (15, 30 and 45 $\mu$sec) at a DC pulse of 1.8 kV/cm, 15 (45.5%, 120/264) or 30 $\mu$ sec group (43.9%, 106/241) showed a higher fusion rate than 45 $\mu$sec group (23.2%, 58/250, P<0.05). However, no difference was detected in the development rate of the fused oocytes to blastocysts between groups. Next experiment was to examine the effects of different electrical field strengths (1.5, 1.8 and 2.1 kV/cm) for 15 $\mu$sec at electrofusion on in vitro development of the NT embryos. As results, there was no difference in the fusion and developmental rates of the NT embryos between electrical strength (P>0.05). Finally, developmental competence of bovine NT embryos with somatic cells was compared with IVF-derived embryos. Of enucleated oocytes fused with fibroblast cells, 27.4% (75/274) developed to the blastocyst stage, which is similar to that (24.5%, 58/237) of IVF-derived embryos. However, mean nuclei number of NT blastocysts was smaller than that of IVF-derived blastocysts. Thus, we have established an optimal condition (1.8 kV/cm, 15 $\mu$sec) for electric fusion of bovine NT oocytes with somatic cells. The present study indicates that bovine reconstructed embryos with somatic cells normally develop to blastocyst stage in vitro, although having smaller nuclei numbers of blastocysts as compared to IVF-derived embryos.

  • PDF

Heavy concrete shielding properties for carbon therapy

  • Jin-Long Wang;Jiade J Lu;Da-Jun Ding;Wen-Hua Jiang;Ya-Dong Li;Rui Qiu;Hui Zhang;Xiao-Zhong Wang;Huo-Sheng Ruan;Yan-Bing Teng;Xiao-Guang Wu;Yun Zheng;Zi-Hao Zhao;Kai-Zhong Liao;Huan-Cheng Mai;Xiao-Dong Wang;Ke Peng;Wei Wang;Zhan Tang;Zhao-Yan Yu;Zhen Wu;Hong-Hu Song;Shuo-Yang Wei;Sen-Lin Mao;Jun Xu;Jing Tao;Min-Qiang Zhang;Xi-Qiang Xue;Ming Wang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2335-2347
    • /
    • 2023
  • As medical facilities are usually built at urban areas, special concrete aggregates and evaluation methods are needed to optimize the design of concrete walls by balancing density, thickness, material composition, cost, and other factors. Carbon treatment rooms require a high radiation shielding requirement, as the neutron yield from carbon therapy is much higher than the neutron yield of protons. In this case study, the maximum carbon energy is 430 MeV/u and the maximum current is 0.27 nA from a hybrid particle therapy system. Hospital or facility construction should consider this requirement to design a special heavy concrete. In this work, magnetite is adopted as the major aggregate. Density is determined mainly by the major aggregate content of magnetite, and a heavy concrete test block was constructed for structural tests. The compressive strength is 35.7 MPa. The density ranges from 3.65 g/cm3 to 4.14 g/cm3, and the iron mass content ranges from 53.78% to 60.38% from the 12 cored sample measurements. It was found that there is a linear relationship between density and iron content, and mixing impurities should be the major reason leading to the nonuniform element and density distribution. The effect of this nonuniformity on radiation shielding properties for a carbon treatment room is investigated by three groups of Monte Carlo simulations. Higher density dominates to reduce shielding thickness. However, a higher content of high-Z elements will weaken the shielding strength, especially at a lower dose rate threshold and vice versa. The weakened side effect of a high iron content on the shielding property is obvious at 2.5 µSv=h. Therefore, we should not blindly pursue high Z content in engineering. If the thickness is constrained to 2 m, then the density can be reduced to 3.3 g/cm3, which will save cost by reducing the magnetite composition with 50.44% iron content. If a higher density of 3.9 g/cm3 with 57.65% iron content is selected for construction, then the thickness of the wall can be reduced to 174.2 cm, which will save space for equipment installation.