• 제목/요약/키워드: Lung, CT

검색결과 857건 처리시간 0.039초

Analysis on Early Detection of Lung Cancer by PET/CT Scan

  • Wang, Huo-Qiang;Zhao, Long;Zhao, Juan;Wang, Qiang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권6호
    • /
    • pp.2215-2217
    • /
    • 2015
  • Background: This systemic analysis was conducted to to evaluate the application value of positron emission tomography/computed tomography (PET/CT) in early diagnosis of lung cancer. Methods: Clinical studies evaluating the application value of PET/CT for patients underwent PET/CT imaging. The histological diagnosis served as the standard of truth. Results: Four clinical studies which including 1330 patients with pulmonary spaceoccupying lesions were considered eligible for inclusion. Systemic analysis suggested that, in all 1330 patients, pooled sensitivity was 98.7% (1313.2/1330) and specificity was 58.2%(276.85/476). Conclusion: This systemic analysis suggests that integrated PET/CT imaging provides high sensitivity, and reasonably high specificity, and could be applied for early diagnosis of lung cancer.

99mTc-3PRGD2 SPECT/CT Imaging for Diagnosing Lymph Node Metastasis of Primary Malignant Lung Tumors

  • Liming Xiao;Shupeng Yu;Weina Xu;Yishan Sun;Jun Xin
    • Korean Journal of Radiology
    • /
    • 제24권11호
    • /
    • pp.1142-1150
    • /
    • 2023
  • Objective: To evaluate 99mtechnetium-three polyethylene glycol spacers-arginine-glycine-aspartic acid (99mTc-3PRGD2) single-photon emission computed tomography (SPECT)/computed tomography (CT) imaging for diagnosing lymph node metastasis of primary malignant lung neoplasms. Materials and Methods: We prospectively enrolled 26 patients with primary malignant lung tumors who underwent 99mTc-3PRGD2 SPECT/CT and 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/CT imaging. Both imaging methods were analyzed in qualitative (visual dichotomous and 5-point grades for lymph nodes and lung tumors, respectively) and semiquantitative (maximum tissue-to-background radioactive count) manners for the lymph nodes and lung tumors. The performance of the differentiation of lymph nodes with and without metastasis was determined at the per-lymph node station and per-patient levels using histopathological results as the reference standard. Results: Total 42 stations had metastatic lymph nodes and 136 stations had benign lymph nodes. The differences between metastatic and benign lymph nodes in the visual qualitative and semiquantitative analyses of 99mTc-3PRGD2 SPECT/CT and 18F-FDG PET/CT were statistically significant (all P < 0.001). The area under the receiver operating characteristic curve (AUC) in the semi-quantitative analysis of 99mTc-3PRGD2 SPECT/CT was 0.908 (95% confidence interval [CI], 0.851-0.966), and the sensitivity, specificity, positive predictive value, and negative predictive value were 0.86 (36/42), 0.88 (120/136), 0.69 (36/52), and 0.95 (120/126), respectively. Among the 26 patients (including two patients each with two lung tumors), 15 had pathologically confirmed lymph node metastasis. The difference between primary lung lesions in patients with and without lymph node metastasis was statistically significant only in the semi-quantitative analysis of 99mTc-3PRGD2 SPECT/CT (P = 0.007), with an AUC of 0.807 (95% CI, 0.641-0.974). Conclusion: 99mTc-3PRGD2 SPECT/CT imaging may notably perform in the direct diagnosis of lymph node metastasis of primary malignant lung tumors and indirectly predict the presence of lymph node metastasis through uptake in the primary lesions.

Radiography and Computed Tomography in Four Dogs with Lung Lobe Torsion (흉부 방사선 촬영과 컴퓨터단층촬영을 이용한 폐염전의 진단 4례)

  • Lee, Ki-Ja;Choi, Sung-Jin;Kim, Young-Hwan;Jeong, In-Seong;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • 제30권5호
    • /
    • pp.390-393
    • /
    • 2013
  • This case study describes the imaging features of radiography and computed tomography (CT) in four small breed dogs with lung lobe torsion. The medical records, thoracic radiographs and CT images of four dogs with confirmed lung lobe torsion were retrospectively reviewed. Pleural effusion and increased lobar opacity/density were seen on all CT and thoracic radiography in all four dogs. CT revealed narrowed/collapsed bronchus in all four dogs, while this was only appreciated on one thoracic radiography. The vesicular emphysema pattern was seen on four CT but only on three radiographic examinations. The specific findings of lung lobe torsion were vesicular emphysema and a narrowed/collapsed bronchus. These findings were more easily recognized on CT than with thoracic radiographs.

Posterior Lung Herniation in Pulmonary Agenesis and Aplasia: Chest Radiograph and Cross-Sectional Imaging Correlation

  • Ji Young Kim;Woo Sun Kim;Kyung Soo Lee;Bo-Kyung Je;Ji Eun Park;Young Jin Ryu;Young Hun Choi;Jung-Eun Cheon
    • Korean Journal of Radiology
    • /
    • 제22권10호
    • /
    • pp.1690-1696
    • /
    • 2021
  • Objective: To describe the anatomic locations and imaging features of posterior lung herniation in unilateral pulmonary agenesis and aplasia, focusing on radiograph-CT/MRI correlation. Materials and Methods: A total of 10 patients (seven with pulmonary agenesis and three with pulmonary aplasia, male: female = 1:9, mean age 7.3 years, age range from 1 month to 20 years) were included. Chest radiographs (n = 9), CT (n = 9), and MRI (n = 1) were reviewed to assess the type of lung underdevelopment, presence of anterior and posterior lung herniation, bronchus origin, supplying artery, and draining vein of the herniated lung. Results: Pulmonary agenesis/aplasia more commonly affected the left lung (n = 7) than the right lung (n = 3). Anterior lung herniation was observed in nine of the 10 patients. Posterior lung herniation was observed in seven patients with left pulmonary agenesis/aplasia. Two patients showed posterior lung herniation crossing the midline but not beyond the aorta, and five patients showed the posteriorly herniated right lower lobe crossing the midline to extend into the left hemithorax farther beyond the descending thoracic aorta through the space between the esophagus and the aorta. This anatomical configuration resulted in a characteristic radiographic finding of a radiolucent area with a convex lateral border and a vertical medial border in the left lower lung zone, revealing a tongue-like projection on CT and MRI. Conclusion: Posterior lung herniation occurs in unilateral left lung agenesis/aplasia. Approximately 70% of the cases of posterior lung herniation reveal a unique radiolucent tongue-like projection in the left lower lung zone on imaging studies, which is caused by the extension of the posteriorly herniated right lung farther beyond the descending aorta.

Differential Absorption Analysis of Nonmagnetic Material in the Phantom using Dual CT

  • Kim, Ki-Youl;Lee, Hae-Kag;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.286-292
    • /
    • 2016
  • This study evaluates the change of computer tomography (CT) number in the case of the metal artifact reduction (MAR) algorithm, using the phantom. The images were obtained from dual CT using a gammex 467 tissue characterization phantom, which is similar to human tissues. The test method was performed by dividing pre and post MAR algorithm and measured CT values of nonmagnetic materials within the phantom. In addition, the changes of CT values for each material were compared and analyzed after measuring CT values up to 140 keV, using the spectral HU curve followed by CT scan. As a result, in the cases of N rod (trabecular bone) and E rod (trabecular bone), the CT numbers decreased as keV increasing but were constant above 90 keV. In the cases of I rod (dense bone) and K rod (dense bone), the CT numbers also decreased as keV increased but were uniform above 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of J rod (liver), D rod (liver), L rod (muscle), and F rod (muscle). For A rod (adipose), G rod (adipose), B rod (breast) and O rod (breast), the CT numbers increased as keV increased but were constant after 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of C rod (lung (exhale)), P rod (lung (exhale)), M rod (lung (inhale)) and H rod (lung (exhale)). Conclusively, because dual CT exhibits no changes in image quality and is able to analyze nonmagnetic materials by measuring the CT values of various materials, it will be used in the future as a useful tool for the diagnosis of lesions.

Frequently Asked Questions in the Interpretation of Preoperative and Postoperative Chest CT Scans Related to Lung Cancer Imaging

  • Lee, Kyung-Soo
    • 대한핵의학회:학술대회논문집
    • /
    • 대한핵의학회 2002년도 춘계학술대회 및 총회
    • /
    • pp.25-27
    • /
    • 2002
  • With the advent of multidetector-row CT, lung cancer imaging is much more promising than before. However, the effectiveness of multidetector-row CT in making an initial diagnosis, staging, and evaluating post-treatment changes of lung cancer still remains to be proved. Fast imaging along with volumetric data set and attendant multi-planar imaging provide much more details on the anatomic changes and pathology associated with lung cancer. However, with images showing anatomic and pathologic changes only, radiologists confront with several questions the answers of which may help evaluate lung cancer more thoroughly. The frequent questions that I have in dally practice of chest CT interpretation are as follows.

  • PDF

Recurrence and Metastasis of Lung Cancer Demonstrate Decreased Diffusion on Diffusion-Weighted Magnetic Resonance Imaging

  • Usuda, Katsuo;Sagawa, Motoyasu;Motomo, Nozomu;Ueno, Masakatsu;Tanaka, Makoto;Machida, Yuichiro;Maeda, Sumiko;Matoba, Munetaka;Tonami, Hisao;Ueda, Yoshimichi;Sakuma, Tsutomu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권16호
    • /
    • pp.6843-6848
    • /
    • 2014
  • Background: Diffusion-weighted magnetic resonance imaging (DWI) is reported to be useful for detecting malignant lesions. The purpose of this study is to clarify characteristics of imaging, detection rate and sensitivity of DWI for recurrence or metastasis of lung cancer. Methods: A total of 36 lung cancer patients with recurrence or metastasis were enrolled in this study. While 16 patients underwent magnetic resonance imaging (MRI), computed tomography (CT) and positron emission tomography-computed tomography (PET-CT), 17 underwent MRI and CT, and 3 underwent MRI and PET-CT. Results: Each recurrence or metastasis showed decreased diffusion, which was easily recognized in DWI. The detection rate for recurrence or metastasis was 100% (36/36) in DWI, 89% (17/19) in PET-CT and 82% (27/33) in CT. Detection rate of DWI was significantly higher than that of CT (p=0.0244) but not significantly higher than that of PET-CT (p=0.22). When the optimal cutoff value of the apparent diffusion coefficient value was set as $1.70{\times}10^{-3}mm^2/sec$, the sensitivity of DWI for diagnosing recurrence or metastasis of lung cancer was 95.6%. Conclusions: DWI is useful for detection of recurrence and metastasis of lung cancer.

CT Densitometry of Normal Tissue and Mass of Lung according to Reconstruction Algorithm (재구성 연산 방식에 따른 흉부의 정상 조직과 종괴의 CT 밀도 측정)

  • Yoon, Han-Sik
    • Journal of radiological science and technology
    • /
    • 제25권2호
    • /
    • pp.39-45
    • /
    • 2002
  • Fifty patients with lung mass were studied to evaluate the effect of reconstruction algorithm on the CT number of lung mass and normal thoracic tissues. In each examination, the CT image of the lung mass was reconstructed using soft, standard, detail and bone algorithm. The results were shown as follows 1. the average maximum difference of lung mass density on the ROIs using 4 different algorithms was less than 1HU. 2. The maximum difference in the degree of lung mass enhancement was respectively $0.1{\sim}3.2HU$ (ROI $0.5\;cm^2$), $0.1{\sim}2.8HU$(ROI $3\;cm^2$) and $0.0{\sim}2.1$(ROI $6\;cm^2$). 3. The mean density of the normal thoracic tissues was highest in the bone algorithm, though there was no significant between 4 different reconstruction algorithms(p = 1.00).

  • PDF

Combination of 18F-Fluorodeoxyglucose PET/CT Radiomics and Clinical Features for Predicting Epidermal Growth Factor Receptor Mutations in Lung Adenocarcinoma

  • Shen Li;Yadi Li;Min Zhao;Pengyuan Wang;Jun Xin
    • Korean Journal of Radiology
    • /
    • 제23권9호
    • /
    • pp.921-930
    • /
    • 2022
  • Objective: To identify epidermal growth factor receptor (EGFR) mutations in lung adenocarcinoma based on 18F-fluorodeoxyglucose (FDG) PET/CT radiomics and clinical features and to distinguish EGFR exon 19 deletion (19 del) and exon 21 L858R missense (21 L858R) mutations using FDG PET/CT radiomics. Materials and Methods: We retrospectively analyzed 179 patients with lung adenocarcinoma. They were randomly assigned to training (n = 125) and testing (n = 54) cohorts in a 7:3 ratio. A total of 2632 radiomics features were extracted from the tumor region of interest from the PET (1316) and CT (1316) images. Six PET/CT radiomics features that remained after the feature selection step were used to calculate the radiomics model score (rad-score). Subsequently, a combined clinical and radiomics model was constructed based on sex, smoking history, tumor diameter, and rad-score. The performance of the combined model in identifying EGFR mutations was assessed using a receiver operating characteristic (ROC) curve. Furthermore, in a subsample of 99 patients, a PET/CT radiomics model for distinguishing 19 del and 21 L858R EGFR mutational subtypes was established, and its performance was evaluated. Results: The area under the ROC curve (AUROC) and accuracy of the combined clinical and PET/CT radiomics models were 0.882 and 81.6%, respectively, in the training cohort and 0.837 and 74.1%, respectively, in the testing cohort. The AUROC and accuracy of the radiomics model for distinguishing between 19 del and 21 L858R EGFR mutational subtypes were 0.708 and 66.7%, respectively, in the training cohort and 0.652 and 56.7%, respectively, in the testing cohort. Conclusion: The combined clinical and PET/CT radiomics model could identify the EGFR mutational status in lung adenocarcinoma with moderate accuracy. However, distinguishing between EGFR 19 del and 21 L858R mutational subtypes was more challenging using PET/CT radiomics.

Comparison of Predicted Postoperative Lung Function in Pneumonectomy Using Computed Tomography and Lung Perfusion Scans

  • Kang, Hee Joon;Lee, Seok Soo
    • Journal of Chest Surgery
    • /
    • 제54권6호
    • /
    • pp.487-493
    • /
    • 2021
  • Background: Predicting postoperative lung function after pneumonectomy is essential. We retrospectively compared postoperative lung function to predicted postoperative lung function based on computed tomography (CT) volumetry and perfusion scintigraphy in patients who underwent pneumonectomy. Methods: Predicted postoperative lung function was calculated based on perfusion scintigraphy and CT volumetry. The predicted function was compared to the postoperative lung function in terms of forced vital capacity (FVC) and forced expiratory volume in 1 second (FEV1), using 4 parameters: FVC, FVC%, FEV1, and FEV1%. Results: The correlations between postoperative function and predicted function based on CT volumetry were r=0.632 (p=0.003) for FVC% and r=0.728 (p<0.001) for FEV1%. The correlations between postoperative function and predicted postoperative function based on perfusion scintigraphy were r=0.654 (p=0.002) for FVC% and r=0.758 (p<0.001) for FEV1%. The preoperative Eastern Cooperative Oncology Group (ECOG) scores were significantly higher in the group in which the gap between postoperative FEV1 and predicted postoperative FEV1 analyzed by CT was smaller than the gap analyzed by perfusion scintigraphy (1.2±0.62 vs. 0.4±0.52, p=0.006). Conclusion: This study affirms that CT volumetry can replace perfusion scintigraphy for preoperative evaluation of patients needing pneumonectomy. In particular, it was found to be a better predictor of postoperative lung function for poor-performance patients (i.e., those with high ECOG scores).