• 제목/요약/키워드: Luminance measurement

검색결과 121건 처리시간 0.024초

영상의학 검사 판독용 모니터 정도관리 Guiding Instrument 제작과 유용성 고찰 (A Study on Production and Its Usefulness of AAPM TG18 Guiding Instrument for Diagnostic Monitor QC)

  • 손기경;성동욱;정재호;강희두;류경남
    • 대한디지털의료영상학회논문지
    • /
    • 제10권1호
    • /
    • pp.21-28
    • /
    • 2008
  • Diagnostic display monitor QA according to AAPM TG18 is usually performed by PACS administrator, product manager and reading doctor, and for acceptance testing and periodic quality control evaluation, a combination of visual and quantitative tests can be used, as outlined in sections 5 and 6 of 'assessment of display performance for medical imaging systems'. Although many display tests can be performed visually, a more objective and quantitative evaluation of display performance requires special test tools. The required instruments vary in their complexity and cost, depending on the context of the evaluation(research, acceptance testing, or quality control) and how thorough the evaluation needs to be. Objective and reliable assessment of many display characteristics can be performed with relatively inexpensive equipment, So, we made 'AAPM TG18 guiding instrument' to ues variable purpose of the evaluation of 'geometrical distortions(quantitative"', 'veiling glare(visual)' and 'sensor calibration'. The spatial measurements for the quantitative evaluation of geometric distortions, and the measurement of the veling-glare ring response function which provides information regarding the spatial extent of the luminance spread, can be performed using the TG18 guiding instrument can be used to sensor calibration to standardize the basic rate of 0% luminance when periodic calibration.

  • PDF

회절 광학 소자 기반 적응형 전조등 시스템 연구 (A Study on Adaptive Front-Lighting System based on Diffractive Optical Element)

  • 신성욱;박승호;유경선;노명재
    • 산업과 과학
    • /
    • 제2권4호
    • /
    • pp.28-35
    • /
    • 2023
  • 본 논문에서는 적응형 전조등 시스템 규정 중 일반도로 모드, 고속도로 모드, 젖은도로 모드를 만족하는 배광의 형성을 위한 회절 광학 소자를 설계하였으며, 이를 GDSII 스트림 형식의 파일로 도출하였다. 회절 광학 요소를 통해 형성된 배광의 유효성 및 백색광 구현 여부 확인을 위하여 각각 Field Tracing, Ray Tracing 기반의 시뮬레이션을 진행하여 변환빔 측정점에 대한 위치 요구사항 및 광도 요구사항의 만족을 확인하였다. 본 연구를 기반으로 적응형 전조등을 구현하는 경우, 광도의 대비 재현 및 단순한 구조의 적응형 전조등 시스템 구현이 가능할 것으로 예상된다.

V-Q lissajous 도형을 이용한 전계발광 소자의 메모리 특성 측정 (Memory Characteristic Measurement of Electroluminescent Device using V-Q Lissajous' Figure)

  • 정득영;임민수;윤성현;신유섭;권순석;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1783-1785
    • /
    • 1999
  • In this paper, we apply V-Q Lissajoucs' figure for observation of a V-Q (Voltage-Charge) hysteresis loop at interface between phosphor and insulation layer in P-ELDz which are a simple structure and the back lighting of LCDs (Liquid Crystal Display). In V-Q Lissajous' figure, we measured a change of hysteresis loop according to the thickness of Insulation and phosphor layer. From experiment result, we will be obtained a optimum thickness of insulation with comparing the correlation of a V-L (Voltage-Luminance) and V-Q hysteresis loop.

  • PDF

야경의 주관적 이미지에 관한 현지평가와 슬라이드평가의 비교분석 (A Comparative Analysis of Field and Slide Survey on Subjective Image of the Nightscape)

  • 안현태;문기훈;김정태
    • KIEAE Journal
    • /
    • 제7권2호
    • /
    • pp.31-37
    • /
    • 2007
  • Despite of many supportive research to the usefulness of slide evaluation on environment of outdoor lighting, study method of using slides have provoked many discussions of its manifestation of reality of field conditions. This study aims to compare the results of slide survey with that of field survey. Distant view and short range view of nightscape of Seoul were selected. Field measurement of luminance and chromaticity were conducted and questionnaire survey were conducted. Frequency analysis, T-test, factor analysis were conducted. Results shows that distant view and short range view of field survey have better visual atmosphere than slide survey. In addition, slide survey on distant view shows lowest values. Difference between field survey and slide survey on distant view is much bigger than the results of short range view.

HDTV용 CRT 프로젝션 광학엔진의 MTF 측정 연구MTF (measurement for optical engine of CRT rear projection HDTV)

  • Song, Jong-Sup;Lee, Ji-Young;Lee, Yun-Woo;Lee, Hoi-Youn;Lee, In-Won;Jo, Jae-Heung;Kim, Jin-Ho;Park, Sang-Kyung
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2002년도 하계학술발표회
    • /
    • pp.34-35
    • /
    • 2002
  • Large-screen projectors for video applications and computer monitors are convenient instruments for conference presentations as well as for TV use at home. Recently, CRT and LCD projectors have achieved higher resolutions and luminance in the projection TV The large surface of the CRT compared to the LCD allows a great number of pixels to be displayed, while simultaneously providing maximum brightness of the final picture. (omitted)

  • PDF

A Psychophysical Approach to the Evaluation of Perceived Focusing Quality of CRT Displays

  • Yoon, Kwang-Ho;Kim, Sang-Ho;Chang, Sung-Ho
    • Journal of Information Display
    • /
    • 제5권3호
    • /
    • pp.35-40
    • /
    • 2004
  • In this study, we collected data used to formulate the relationship between quantitative metrological parameters in CRT display and the perceived focus quality. Human perception of the focusing quality was evaluated in terms of user feedback scores regarding the character legibility from four highly trained inspectors. Thirteen CRT monitors from five different manufacturers were compared relatively with respect to the norm monitor. The profile of electron beam such as spot size and the shape of distribution made by electron beam, contrast, convergence of RGB beams, and luminance characteristics were measured using a precision measurement system. Linear regression analysis and artificial neural network models were used to formulate the relationship between human perception and the quantitative measurements. The accuracy of the formulated linear regression model ($R^2$=0.515) was not satisfactory but the nonlinear neural network model ($R^2$=0.716) was fairly convincing and robust even the utilized data included subjective differences.

신경망을 이용한 온도장 측정법 개선 방안 (Improvements of Temperature Field Measurement Technique using Neural Network)

  • 황태규;문지섭;장태현;도덕희
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.52-55
    • /
    • 2004
  • Thermo-chromic Liquid Crystal(TLC) particles were used as temperature sensor for thermal fluid flow. $1K\times1K$ CCD color camera and Xenon Lamp(500W) were used for the visualization of a Hele-Shaw cell. The characteristic between the reflected colors from the TLC and their corresponding temperature shows strong non-linearity. A neural network known as having strong mapping capability for non-linearity is adopted to quantify the temperature field using the image of the flow. Improvements of color-to-temperature mapping was attained by using the local color luminance (Y) and hue (H) information as the inputs for the constructed neural network.

  • PDF

Low-voltage cathodoluminescent Characteristics of ZnGa$_2$O$_4$ : Mn phosphors

  • 조성희;유재수;이종덕;이중환
    • 한국표면공학회지
    • /
    • 제30권1호
    • /
    • pp.57-62
    • /
    • 1997
  • Green-emitting $ZnGa_2O_4$ : Mn phosphors were synthesized by a thermal method and their low-voltage cathodoluminescent characteristics were examined for the field emitter display (FED) application. Low efficiency of $ZnGa_2O_4$ : Mn phosphors could be ascribed to the low penetration depth of into phosphors, which might results in charge accumulation on the phosphors screen. For increasing cathodoluminescent of $ZnGa_2O_4$ : Mn under low voltage excitation, wide band-gap oxide materials were added to the $ZnGa_2O_4$: Mn powder. It is found that the luminance can be increased by 20%. Measurement of leakage current on the phosphor screen shows that the enhancement of low-voltage cathodoluminescent by additive materials is mainly due to the consumption of surface charges on the phosphor.

  • PDF

Characterization of one Time-Sequential Stereoscopic 3D Display - Part I: Temporal Analysis -

  • Pierre, Boher;Thierry, Leroux;Collomb-Patton, Veronique
    • Journal of Information Display
    • /
    • 제11권2호
    • /
    • pp.57-62
    • /
    • 2010
  • A method of characterizing time-sequential stereoscopic 3D displays based on the measurement of the temporal behavior of the systems vs. the grey levels is proposed. An Nvidia 3D vision kit with a 3D-ready SAMSUNG 2233RZ LCD display is characterized in the paper. OPTISCOPE SA especially designed for the precise measurements of the luminance and temporal behavior of LCD displays was used. The transmittance and response time of the shutter glasses was first evaluated. Then the grey-to-grey response times of the display were measured. The 2D and 3D behaviors of the display were then compared. Finally, the temporal behavior of the complete system was modeled, and the grey-level variations on one view were deduced as a function of the synchronization and level of the other eye. The main sources of imperfection were identified and quantified, and a full computation of the system performances was done.

플라즈마 디스플레이 패널의 휘도 및 발광효율의 측정 (Measurement of Luminance and Luminous Efficiency of Plasma Display Panel)

  • 구치욱;이형구;최용섭;고광철;강형부;정규선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2218-2220
    • /
    • 1999
  • Plasma Display Panel(PDP) has mirco-cell, so it is difficult to know the physical properties of particles in PDP cell. To know this, we made a cell that is 200 times as large as a general PDP cell. Using this cell, the temperature and the density of electrons have been measured by the fast scanning probe.

  • PDF