Abstract
Despite of many supportive research to the usefulness of slide evaluation on environment of outdoor lighting, study method of using slides have provoked many discussions of its manifestation of reality of field conditions. This study aims to compare the results of slide survey with that of field survey. Distant view and short range view of nightscape of Seoul were selected. Field measurement of luminance and chromaticity were conducted and questionnaire survey were conducted. Frequency analysis, T-test, factor analysis were conducted. Results shows that distant view and short range view of field survey have better visual atmosphere than slide survey. In addition, slide survey on distant view shows lowest values. Difference between field survey and slide survey on distant view is much bigger than the results of short range view.