• Title/Summary/Keyword: Lumbar Projection

Search Result 14, Processing Time 0.025 seconds

The Image Resolution Compare to Having Lead Plate or Not Lumbar Lateral Projection

  • Kim, Hyun-Soo;Min, Jung-Whan;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.145-151
    • /
    • 2011
  • The purpose of this study is to know some changes of resolution and image if we remove scattered ray using lead plate when doing lumbar lateral projection. Using 3 DR system(2 FD types, 1 CCD type) equipments and 2 film system equipments, we gain the image whether the phantom of abdomen equivalent sticking resolution chart has lead plate or not, whether we do collimation or not. Also, we use ion chamber, measure radiation exposure rate and change to entrance surface dose from it. we gain that images in the greatest condition of taking in clinic. 5 people in this group decoded resolution with our eyes, measured thickness of images and compared them from each equiments. Resolution has difference to size of collimation in DR FD type. Also there is no difference the original image with the new image which we abbreviated mAs. In DR CCD type, resolution didn't have difference whether lead plate is or not and whether we do collimation or not. In film type, existing or nonexisting of lead plate didn't influence on resolution. Lead plate makes the quality of image higher due to reducing scattered ray, it doesn't influence on resolution.

  • PDF

A Study of the Back Shape of the Children in Elementary and Middle Schools Using the Phase-shifting Scanning Grating Projection moire (위상천이 주사격자 영사식 모아레 간섭계를 이용한 초.중학생의 배부체형고찰)

  • 유한길;민병일;박동석
    • The Journal of Korean Medicine
    • /
    • v.21 no.4
    • /
    • pp.148-158
    • /
    • 2000
  • Objective : The purpose of this study was to investigate the back shape of school children using the phase-shifting scanning grating projection moire interferometer, which was developed by the Korea Advanced Institute of Science and Technology and is useful in evaluating three dimensional back shape. Methods : In this study the subjects consisted of 1,358 pupils [711 boys(52.36%), 647 girls(47.64%)] attending elementary and middle schools in Seoul. Their ages ranged from nine to fifteen and the average age was 12.2. With the phase-shifting scanning grating projection moire interferometer, the posterior view of the body were taken to see if there are correlations of moire fringe number, width difference between left and right, and correlation between differences in moire fringe number and width on both sides in the scapular, lumbar and gluteal regions. Results : The results were as follows : I. More frequent findings of fringe were observed on the right in all regions : in the scapular region, 309 boys(43.4%) and 156 girls(24.2%) had more fringe numbers on the right side; in the lumbar region, 68 boys(9.5%) and 11 girls(1.7%); and in the gluteal region, 160 boys(22.4%) and 63 girls(9.8%). Such tendency was striking especially in the scapular and lumbar regions, and in boys rather than in girls. In the scapula, 661 subjects(48.7%) with one moire fringe on either side need further attention and 110 subjects(8.I %) with two or more are required to do follow-up radiography for scoliosis. 2. In an analysis of width difference in the trunk, the left side is wider in all regions except for the gluteal region in boys : in the scapular region 21 boys(3.0%) and 103 girls(15.9%); in the lumbar region, 87 boys(12.2%) and 250 girls(38.6%); and in the gluteal region 197 girls(30.4%) had a wider left side and 45 boys(6.3%) showed a wider right side. 3. In correlation analysis of the number of moire fringe and width difference in each region, the side where more moire fringes were observed was significantly wider in the lumbar and gluteal regions, but not in the scapular region.(p<0.01) Conclusions : From these results, it is concluded that the back shape of elementary and middle school students in Seoul shows that the right side had more moire fringes; the left side was wider; and especially in the lumbar and gluteal regions the side where more moire fringes were observed was wider.

  • PDF

Evaluation on Organ Dose and Image Quality of Lumbar Spine Radiography Using Glass Dosimeter (유리선량계를 이용한 요추검사의 장기선량 및 영상의 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • The purpose of this study was to provide resources for medical exposure reduction through evaluation of organ dose and image resolution for lumbar spine around according to the size of the collimator in DR system. The size of the collimator were varied from $8^{\prime\prime}{\times}17^{\prime\prime}$ to $14^{\prime\prime}{\times}17^{\prime\prime}$ by 1" in AP and lateral projection for the lumbar spine radiography with RANDO phantom. The organ dose measured for liver, stomach, pancreas, kidney and gonad by the glass dosimeter. The image resolution was analyzed using the Image J program. The organ dose of around lumbar spine were reduced as the size of the collimator is decreased in AP projection. There were no significant changes decreasing rate whenever the size of the collimator were reduced 1" in the gonad. The organ dose showed higher on liver and kidney near the surface in lateral projection. There were decreasing rate of less than 5% in liver and kidney, but decreasing rate was 24.34% in the gonad whenever the size of the collimator were reduced 1". Organ dose difference for internal and external of collimator measured $549.8{\mu}Gy$ in the liver and $264.6{\mu}Gy$ in the stomach. There were no significant changes organ dose difference that measured $1,135.1{\mu}Gy$ in the gonad. Image Quality made no difference because SNR and PSNR were over than 30 dB when the collimator size is less than $9^{\prime\prime}{\times}17^{\prime\prime}$ on AP projection and $10^{\prime\prime}{\times}17^{\prime\prime}$ on lateral projection. Therefore, we are considered that the recommendations criterion for control of collimator were suggested in order to reduce unnecessary X-ray exposure and to obtain good image quality because lumbar spine radiography contains a lot of peripheral organs rather than other area radiography.

Distribution of Neurons in the Lateral Reticular Nucleus Projecting to Cervical, Thoracic, and Lumbar Segments , of the Spinal Cord in the Rat

  • Lee, Hyun Sook
    • Animal cells and systems
    • /
    • v.4 no.4
    • /
    • pp.353-359
    • /
    • 2000
  • Location of the neurons in the lateral reticular nucleus projecting to dorsal horn of the cervical, thoracic, or lumbar spinal cord was investigated in the rat using the technique of retrograde transport of horseradish peroxidase. The projection was bilateral with ipsilateral predominance. Neurons projecting to the cervical spinal cord were located near the medial, dorsal, and lateral perimeter of the magnocellular division of the lateral reticular nucleus, whereas cells projecting to the thoracic and lumbar spinal cord were localized in the medial and dorsal boundaries of the magnocellular division. The labeled neurons were distinctly multipolar in shape and measured approximately 10-15 $\mu m$ in their greatest transverse diameter. A few neurons were also observed in the subtrigeminal nucleus, whereas few cells were in the parbocellular division. These observations provide an anatomical substrate for the functional implication of the lateral reticular nucleus in the regulation of spinal nociceptive transmission and vascular hemodynamics via the descending pathway into the spinal cord.

  • PDF

Osteochondroma of the 3rd Lumbar Spine Causing Spinal Compression - A Case Report - (척수 압박을 동반한 제 3 요추의 골연골종 - 1례 보고 -)

  • Kim, Hyung-Seok;Hong, Ki-Do;Ha, Sung-Sik;Lee, Sun-Woo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.3 no.1
    • /
    • pp.26-31
    • /
    • 1997
  • One of the most common benign tumors of bone is the osteochondroma which is a cartilage-capped bony projection on the surface of a bone. It may occur in any bone that has been performed from cartilage, but the most common locations are the long bone at the metaphyseal region of the most active growth cartilage, that is, the lower end of femur, the upper end of the tibia, and the upper end of the humerus. Other bones often involved are the ilium, scapula, fibula, and phalanges of hands and feet. But, the vertebral column is very rare location for osteochondroma. Only one case of osteochondroma involving the lumbar spine has been previously reported in Korea. We report an unusual case of osteochondroma arising from the left lamina and inferior articular process of the 3rd lumbar spine causing spinal cord compression.

  • PDF

A Study on the Optimization of Exposure condition at Lumbar projection Using Blind Test (블라인드 테스트를 통한 요추 검사 시 조사 조건의 최적화 연구)

  • Park, Jikoon;Kim, Kyotae;Yoon, Inchan;Choi, Ilhong;Jung, Hyungjin;Kang, Sangsik;Noh, Sicheul;Jung, Bongjae
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.389-395
    • /
    • 2013
  • This study intended to investigate the optimum conditions for lumbar test that has the highest level of irradiation conditions among general test sites. To to this, the most widely used irradiation conditions in terms of statistics were set as standards; test groups applied with DMF were selected; tests groups suitable for clinical trials were selected by using suggested patient dose. Blind tests were conducted by 10 specialists and radiologists. The results suggested that under the optimum conditions, the radiation dose reduction of 2.09 mGy, 4.42 mGy and 3.65 mGy can be achieved in forward-backward test, lateral test and 4-direction test, respectively. There is a need of further studies on the optimization of irradiation conditions in accordance with the conditions of patients.

The Measurement of Helper's Exposure Dose of nearby Radiographic Table in X-ray Examination (X선 촬영시 테이블 주변 촬영도움자의 피폭선량 측정)

  • Eun, Sung-Jong;Kim, Sung-Gil;Min, Byung-Woon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.415-420
    • /
    • 2011
  • The purpose of this study is to know the exposure dose nearby table on the general radiography(skull AP, chest PA, abdomen AP, lumbar lateral, hip joint, knee joint) and to find the reducing it. We measured beside the 45cm and 75cm table center, and 70cm, 80cm, 130cm, 150cm height from the bottom. That were measured highly from the radiography of lumbar lateral, abdomen AP and hip joint as followed $66.21{\mu}Sv$, $34.22{\mu}Sv$, and $32.35{\mu}Sv$ at the 80cm height beside 45cm from the center of table. Measured doses were reduced in order of chest PA, abdomen, hipjoint, skull, knee joint projection. It appears exposure dose of nearby radiographic table was extremely low amount compared with limit of dose(1mSv). If it protected by Pb apron, exposure dose of assisting person will not be exceed a limit of dose. Conclusively, Wearing apron is very important to avoid radiation from the general radiography.

The Study on Relation of Low back pain and Bone Mineral Density (요통(腰痛)과 골밀도(骨密度)와의 상관성(相關性)에 관한 연구)

  • Park, sang dong;Kim, Kyung Ho;Jang, Jun-Hyouk;Kim, Jeong Seok
    • Journal of Acupuncture Research
    • /
    • v.18 no.2
    • /
    • pp.91-100
    • /
    • 2001
  • Objective : The purpose of this study is to investigate the role of the osteoporosis in low back pain(LBP). Methods : We use method of projection with Quantitative computed tomography(QCT) to estimate Bone mineral density(BMD) of lumbar spine more precisely. From January 1999 to August 2000 we studied lumbar BMD of 46 women with LBP and 53 women with non-LBP, musculoskeletal symptoms who visited Dong-Guk University Bundang Hospital by QCT. Results : 1. Lumbar BMDs in women with LBP and women with non-LBP, musculoskeletal symptom were lower than in normal women and BMDs in women with LBP was higher than in women with non-LBP, musculoskeletal symptom but the significant difference was not revealed between two group in statistics(p<0.05).. 2. Radiological study shows that the number of degenerative spondylosis was 19, compression fracture was 11, non-radiological study was 10, normal was 5 in women with LBP. 3. Radiological study shows that the number of degenerative change was 7, compression fracture was zero, non-radiological study was 33, normal was 5 in women with non-LBP, musculoskeletal symptom. Conclusion : BMDs in women with LBP was higher than in women with non-LBP, musculoskeletat symptom but the significant difference was not revealed between two group in statistics(p<0.05).

  • PDF

Deep Learning Algorithm for Simultaneous Noise Reduction and Edge Sharpening in Low-Dose CT Images: A Pilot Study Using Lumbar Spine CT

  • Hyunjung Yeoh;Sung Hwan Hong;Chulkyun Ahn;Ja-Young Choi;Hee-Dong Chae;Hye Jin Yoo;Jong Hyo Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1850-1857
    • /
    • 2021
  • Objective: The purpose of this study was to assess whether a deep learning (DL) algorithm could enable simultaneous noise reduction and edge sharpening in low-dose lumbar spine CT. Materials and Methods: This retrospective study included 52 patients (26 male and 26 female; median age, 60.5 years) who had undergone CT-guided lumbar bone biopsy between October 2015 and April 2020. Initial 100-mAs survey images and 50-mAs intraprocedural images were reconstructed by filtered back projection. Denoising was performed using a vendor-agnostic DL model (ClariCT.AITM, ClariPI) for the 50-mAS images, and the 50-mAs, denoised 50-mAs, and 100-mAs CT images were compared. Noise, signal-to-noise ratio (SNR), and edge rise distance (ERD) for image sharpness were measured. The data were summarized as the mean ± standard deviation for these parameters. Two musculoskeletal radiologists assessed the visibility of the normal anatomical structures. Results: Noise was lower in the denoised 50-mAs images (36.38 ± 7.03 Hounsfield unit [HU]) than the 50-mAs (93.33 ± 25.36 HU) and 100-mAs (63.33 ± 16.09 HU) images (p < 0.001). The SNRs for the images in descending order were as follows: denoised 50-mAs (1.46 ± 0.54), 100-mAs (0.99 ± 0.34), and 50-mAs (0.58 ± 0.18) images (p < 0.001). The denoised 50-mAs images had better edge sharpness than the 100-mAs images at the vertebral body (ERD; 0.94 ± 0.2 mm vs. 1.05 ± 0.24 mm, p = 0.036) and the psoas (ERD; 0.42 ± 0.09 mm vs. 0.50 ± 0.12 mm, p = 0.002). The denoised 50-mAs images significantly improved the visualization of the normal anatomical structures (p < 0.001). Conclusion: DL-based reconstruction may enable simultaneous noise reduction and improvement in image quality with the preservation of edge sharpness on low-dose lumbar spine CT. Investigations on further radiation dose reduction and the clinical applicability of this technique are warranted.

Morphological study on abdominal organs of healthy cats using omnidirectional radiography and fluoroscopy (다각도 방사선촬영 및 투시법을 이용한 정상 고양이 장기의 형태학적 연구)

  • Shin, Sa-kyeng;Hirose, Tsuneo;Sato, Motoyoshi;Miyahara, Kazuro
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.4
    • /
    • pp.949-966
    • /
    • 1996
  • To establish the method for the most effective radiography and fluoroscopy, the abdominal organs of cats were investigeted using omnidirectional angles with the center of the body as the axis using an omnidirectional protective shielding X-ray system and a $360^{\circ}$ rotary restraint unit for use in small animals. The organs examined were the diaphragm, liver, stomach, colon, spleen and kidney. The results obtained in the present study were as follows: 1. Regardless of gas in the stomach present or not, it was feasible to distinguish the left and right crura in the lumbar portion of diaphragm in the oblique projection inclined over $30^{\circ}$ and under $90^{\circ}$ from the lateral projection. 2. Outlines of the exterior left lobe and the interior right lobe of the liver were observed in the oblique image inclined up to $60^{\circ}$ from the lateral image, while that of the exterior right lobe was noted in the oblique image inclined up to $60^{\circ}$ from the ventrodorsal-dorsoventral images. 3. It was necessary to have gas present in the stomach for detailed morphological observations of the stomach. It was most clearly observed in the right $30^{\circ}$ ventral-left dorsal oblique projection($120^{\circ}$ image) and the left $60^{\circ}$ dorsal-right ventral oblique projection($300^{\circ}$ image). 4. Morphology of the colon was observable in detail by the oblique projection inclined over $30^{\circ}$ from the lateral projection. 5. To observe the whole spleen it was required to have images from the ventrodorsal projection ($90^{\circ}$ image) to the right $60^{\circ}$ ventral-left dorsal oblique projection ($150^{\circ}$ image) as well as those from the dorsoventral projection ($270^{\circ}$ image) to the left-right lateral projection $0^{\circ}$ image). 6. Dorsal and ventral sides of the kidney were observable in the oblique images inclined $30^{\circ}$ from the lateral image. 7. Considering above findings collectively, it was thought that the results of present study might be useful for the analysis of abnormalies in each organ of cat.

  • PDF