• Title/Summary/Keyword: Lower heating value

Search Result 237, Processing Time 0.027 seconds

A Study of Monitoring and Operation for PEM Water Electrolysis and PEM Fuel Cell Through the Convergence of IoT in Smart Energy Campus Microgrid (스마트에너지캠퍼스 마이크로그리드에서 사물인터넷 융합 PEM 전기분해와 PEM 연료전지 모니터링 및 운영 연구)

  • Chang, Hui Il;Thapa, Prakash
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.6
    • /
    • pp.13-21
    • /
    • 2016
  • In this paper we are trying to explain the effect of temperature on polymer membrane exchange water electrolysis (PEMWE) and polymer membrane exchange fuel cell (PEMFC) simultaneously. A comprehensive studying approach is proposed and applied to a 50Watt PEM fuel cell system in the laboratory. The monitoring process is carried out through wireless LoRa node and gateway network concept. In this experiment, temperature sensor measure the temperature level of electrolyzer, fuel cell stack and $H_2$ storage tank and transmitted the measured value of data to the management control unit (MCU) through the individual node and gateway of each PEMWE and PEMFC. In MCU we can monitor the temperature and its effect on the performance of the fuel cell system and control it to keep the lower heating value to increase the efficiency of the fuel cell system. And we also proposed a mathematical model and operation algorithm for PEMWE and PEMFC. In this model, PEMWE gives higher efficiency at lower heating level where as PEMFC gives higher efficiency at higher heating value. In order to increase the performance of the fuel cell system, we are going to monitor, communicate and control the temperature and pressure of PEMWE and PEMFC by installing these systems in a building of university which is located in the southern part of Korea.

Comparison of Recovery Levels of Shigella sonnei ATCC 29930 Treated at Different NaCl Concentrations after Sublethal Heating (Shigella sonnei ATCC 29930의 아치사 가열 후 소금 농도에 따른 회복 정도 비교)

  • Jung, Hye-Jin;Park, Sung-Hee;Song, Eun-Seop;Park, Sung-Soo;Kim, Keun-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.5
    • /
    • pp.720-723
    • /
    • 2006
  • The viability of Shigella sonnei, a significant cause of gastroenteritis in Korea, on TSA plates was determined after sublethal heating treatments and NaCl treatments. In addition, recovery levels of sublethally injured cells on TSA plates containing different concentrations of NaCl (TSAS) were investigated. The viability decreased significantly with increasing degree of sublethal heating treatments, but increases in NaCI treatment concentration from 0 to 6% had little effect on the viability. After being sublethally treated at $55^{\circ}C$ for 30 min, bacterial populations were reduced by 7.58, 7.83 and 7.93 log CFU/mL on 2, 4, and 6% TSAS, respectively. After being sublethally treated at $60^{\circ}C$ for 30 min, bacterial populations were reduced by 6.71, 6.73, and 6.73 log CFU/mL on 2, 4 and 6% TSAS, respectively. Decimal reduction times (D-values) decreased with increasing NaCl treatment concentrations after sublethal heating at 55 or $60^{\circ}C$. These data imply that the S. sonnei cells sublethally injured by insufficient heating processes had a lower recovery rate with increasing NaCl concentrations in the recovery media.

In-situ Structure Modification of W powder Skeleton and related Cu Infiltration Kinetics in W-Cu (W-Cu 계에서 W 분말골격의 in-situ 구조 변화와 Cu의 용침 kinetics)

  • 이재성
    • Journal of Powder Materials
    • /
    • v.6 no.1
    • /
    • pp.36-41
    • /
    • 1999
  • The present work has attempted to investigate the dependence of Cu infiltration kinetics on in-situ structure modification of W powder skeleton in W-Cu system. In-situ structure modification of W skeleton by addition of 0.3wt%Ni-P eutectic alloy was designed to proceed during heat-up of the W compact for Cu infiltration process. It was found that the Ni-P added W skeleton underwent remarkable stucture change only during heating-up. its structure was composed of large necks of W particles above 0.5 in the ratio of neck to particle size and smooth pore channels. The infiltration experiment showed that the infiltration kinetics for the W-Ni-P followed well the linear relationship of h vs. $t^{1/2}$ the rate constant K of which was in good agreement with the theoretical value. On the other hand, in case of the pure W skeleton a lower K value by 20% than the theoretical one was obatined. Such discrepancy is discussed in terms of skeleton structure induced infiltration mechanics.

  • PDF

Diurnal Variation of Atomospheric Pollutant Concentrations Affected by Development of Windstorms along the Lee Side of Coastal Mountain Area

  • Choi, Hyo
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • v.24 no.1
    • /
    • pp.29-45
    • /
    • 1996
  • Before (March 26, 1994) or after the occurrence of a downslope windstorm (March 29), the NO, $NO_2$, and $SO_2$ at the ground level of Kangnung city were monitored with high concentrations in the afternoon, due to a large amount of gases emitted from combustion of motor vehicle and heating apparatus, especially near 1600-1800 LST and 2000-2100 LST, but at night, they had low concentrations, resulting from small consumptions of vehicle and heating fuels. When both moderate westerly synoptic-scale winds flow over Mt. Taegwallyang and easterly meso-scale sea breeze during the day, atmospheric pollutants should be trapped by two different wind systems, resulting in higher concentration at Kangnung city in the afternoon. At night, the association of westerly synoptic wind and land breeze can produce relatively strong winds and the dissipation by the winds cause these low concentrations to lower and lower, as nightime goes on. From March 27 through 28, an enforced localized windstorm could be produced along the lee side of the mountain near Kangnung, generating westerly internal gravity waves with hydraulic jump motions. Sea breeze toward inland appartantly confines to the bottom of the eastern side of the mountain, due to the interruption of eastward violent internal gravity waves. As the windstorm moves down toward the ground, an encountering point of two opposite winds approaches Kangnung, and a great amount of NO and $NO_2$ were removed by the strong surface winds. Thus, their maximum concentrations are found to be near 18 and 20 LST, 17 and 21 LST. In the nighttime, the more developed storm should produce very strong surface winds and the NO and $NO_2$ could be easily dissipated into other place. The $SO_2$ concentration had no maximum value, that is, almost constant one all day long, due to its removal by the strong surface winds. Especially, the CO concentrations were slightly lower during the strom period than both before or after the strom, but they were nearly constant without much changes during the during the daytime and nighttime.

  • PDF

Prediction Technology of Reverse Setting Block Shape with Inherent Strain Method and Re-meshing Technology (고유 변형도법과 리메슁 기술을 접목한 블록의 역세팅 형상 예측기술)

  • Hyun, Chung-Min;Choi, Han-Suk;Park, Chang-Woo;Kim, Sung-Hoon
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.425-430
    • /
    • 2017
  • In order to reduce the cost of corrections and time needed for the block assembly process, the reverse setting method is applied for a back-heated block to neutralize deck deformation. The proper reverse setting shape for a back-heated block to correct deformation improved the deck flatness, but an excessive amount of reverse setting could inversely affect the flatness of the block. A prediction method was developed for the proper reverse setting shape using a back-heated block, considering the complex geometry of blocks, thickness of the deck plate, and thermal loading conditions such as welding and back-heating. The prediction method was developed by combining the re-meshing technique and inherent strain-based deformation analysis using the finite element method. Because the flatness deviation was decreased until the lower critical point and thereafter it tended to increase again, the optimum value for which the flatness was the best case was selected by repeatedly calculating the predefined reverse setting values. Based on this analysis and the study of the back-heating deformation of large assembly blocks, including the reverse setting shape, the mechanism for selecting the optimum reverse setting value was identified. The developed method was applied to the actual blocks of a ship, and it was confirmed that the flatness of the block was improved. It is concluded that the developed prediction method can be used to predict the optimum reverse setting shape value of a ship's block, which will reduce the cost of corrections in the construction stage.

An Analytical Study on Encased Steel Composite Columns Fire Resistance According to Axial Force Ratio (화재시 축력비에 따른 매입형 합성기둥의 내화성능에 대한 해석적 연구)

  • Kim, Ye-Som;Choi, Byong-Jeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.97-107
    • /
    • 2020
  • In this study, finite element analysis was carried out through the finite element analysis program (ANSYS) to investigate the fire resistance of composite columns in fire. Transient heat transfer analysis and static structural analysis were performed according to ASTM E 119 heating curve and axial force ratio 0.7, 0.6, 0.5 by applying stress-strain curves according to temperature, and loading heating experiments were carried out under the same conditions. In addition, the nominal compressive strength of the composite column according to the heating time according to the standard(Eurocode 4) was calculated and expressed as the axial force ratio and compared with the analytical and experimental values. Through the analysis, As a result of finite element analysis, the fire resistance time was 180 minutes and similar value to the experimental value was obtained, whereas the fire resistance time 150 minutes and 60 minutes were derived from the axial force ratios 0.6 and 0.7. In addition, it was confirmed that the fire resistance time according to the axial force ratio calculated according to the reference equation (Eurocode 4) was lower than the actual experimental value. However, it was confirmed that the standard(Eurocode 4) was higher than the experimental value at the axial force ratio of 0.7. Accordingly, it is possible to confirm the fire resistance characteristics(time-axial force ratio relationship) of the SRC column at high axial force, and to use the experimental and anaylsis data of the SRC column as the data for verification based on Eurocode.

Heat-Induced Denaturation of Salt Soluble Protein Extracted from Spent Layer Meat (산란 노계육에서 추출한 염용성 단백질의 열변성에 관한 연구)

  • 이성기;장호선;김희주
    • Food Science of Animal Resources
    • /
    • v.18 no.3
    • /
    • pp.209-215
    • /
    • 1998
  • Effects of protein concentration, ionic strength, pH, and temperature range on the heat-induced denaturation of salt soluble protein extracted from spent layer meat were investigated. Viscosity of salt soluble protein heated at 65$^{\circ}C$ for 30 min began to increase sharply above 7 mg/ml of breast protein concentration, and above 21 mg/ml of leg protein concentration, respectively. Both turbidity and viscosity showed the highest value in cooked protein solution with pH 6.0 and 1% NaCl. The turbidity of salt soluble protein started to increase continuously from 40$^{\circ}C$ to 80$^{\circ}C$. The viscosity increased rapidly from 45$^{\circ}C$ to 60$^{\circ}C$ in breast protein, and increased from 50$^{\circ}C$ to 55$^{\circ}C$ in leg protein, respectively, and then kept relatively constant. Breast protein had higher viscosity than leg protein during heat-induced gelation. Therefore, salt soluble protein from spent layer meat was associated with denatured protein (turbidity change) prior to gelation (viscosity change) during heating. Breast protein showed lower thermal transition temperature, and better gel formation than leg protein during heating.

  • PDF

The Energy Saving Effect and Economic Assessment of Office Building according to the Building Envelope Remodeling (사무소 건물의 외피 리모델링에 따른 에너지절감효과 및 경제성 분석)

  • Choi, Seon woo;Kim, Ji Yeon;Park, Hyo soon;Kim, Jun Tae
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.85-92
    • /
    • 2012
  • The Korean government has introduced building regulations with improved energy conservation measures, including higher insulation levels for building envelope. However, there are many existing buildings that tend to consume more energy for heating and cooling than new buildings, as they were built under the former regulations with relatively higher U-values of walls and glazing. In order to improve energy efficiency in existing buildings, green remodelling of building envelope and building services are required. For existing buildings, building services improvements have been achieved through energy service company(ESCO), but much attention has not been paid to building envelope improvements with various reasons, such as uncertainty of energy saving effect design issues and costs. The aim of this study is to evaluate the impact of building envelope improvements in a typical commercial building on its heating and cooling energy loads. The results show that the improvement of glazing with lower U-values has the highest energy saving effects, followed by wall, roof and floor, under the condition of same level of insulation improvements. However, high insulated glazing increased LCC because of higher initial investment costs.

A Study on the Heating Performance of Ground Source Heat Pump System (지중열원 열펌프 시스템의 난방성능 해석)

  • Woo Joung-Son;Kim Dae-Ki;Lee Se-Kyoun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1175-1182
    • /
    • 2004
  • Installations of vertical boreholes for the ground source heat pump system are expensive to install. One way to reduce the initial cost is to increase the specific heat extraction rate of borehole system. However, as the specific heat extraction rate increases the temperature of borehole fluid decreases with the resultant lower Coefficient Of Performance in Heating(COPH) of heat pump system. The purpose of this study is to provide the basic informations about the performance of heat pump system with the specific heat extraction rate and soil thermal properties such as thermal conductivity and temperature. It is shown that the specific heat extraction rate is the most important parameter for the ground source heat pump system. To obtain the reasonable COPH value (COPH > 3) the heat extraction rate should be about 25 W/m or less. Accurate measurements of soil thermal properties are also very important to design the system properly. The effects of borehole thermal resistances are also examined in this study.

Fuel Characteristics of Biomass Pellets Fabricated with Reed Stalk (갈대를 이용하여 제조한 바이오펠릿의 품질 특성)

  • Kim, Seong-ho;Han, Gyu-Seong
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.48 no.3
    • /
    • pp.99-106
    • /
    • 2016
  • Our aim was to identify the potential of reed stalk as a raw materials for biomass pellet production. Compared to woody biomass, reed stalk contained significant levels of ash. The holocellulose content of reed stalk was similar to that of larch, but the lignin content of reed stalk was lower than that of larch. In the elemental analysis, chlorine content of reed stalk was much higher than that of larch, and satisfied only the mixed biomass pellet B of European non-woody pellet standards(EN 14961-6). In quantitative analysis of the ash, heavy metals contents of reed stalk satisfied European non-woody pellet standards. Higher heating value of oven-dried reed stalk pellet was slightly lower than that of larch wood pellet. The durability of reed stalk pellet was lower than that of larch wood pellet. The results of this study indicate that reed stalk might be used as a raw material of mixed biomass pellet B.