• Title/Summary/Keyword: Lower body compression wear

Search Result 9, Processing Time 0.018 seconds

Compression Wear Design for Women's Soccer Players (여자 축구선수를 위한 컴프레션 웨어 설계)

  • Park, Sanghee
    • Journal of Fashion Business
    • /
    • v.25 no.2
    • /
    • pp.127-142
    • /
    • 2021
  • This study aims to organize the prototype design method of compression wear for women professional soccer players. Despite the excellent performance of female soccer players in world competition, most functional wear has been developed mainly for men, so professional female athletes have fewer choices. Soccer is a sport requiring core and lower body muscle strength, and muscular endurance for long periods of playing or walking on the field. Female soccer players did not differ much in upper body compared to other women, but their lower body had a smaller hip circumference than waist circumference and a larger thigh circumference, requiring compilation considering the physical characteristics and movement of athletes. Female soccer players wear sports bras while playing but regular bras and compression wear during normal exercise because they sweat on under their breast, which irritates sensitive skin. For core muscles in the upper body and to support for thigh and hip muscles in the lower body, the uniform in this study was designed by reducing the body size of a professional female soccer player in her 20s and the actual measurements of commercial compilation software to 81% of the chest circumference, 95% of the waist circumference, and 78% of the hip circumference. The design experiment in this study was a simple exercise and did not produce produce results for long-term exercise and performance improvement, but can be used to design a composition pattern system for other professional female athletes.

Development of Compression Wear Tops for Men in Their Forties Based on Muscle Locations (인체 근육 위치에 기초한 40대 남성을 위한 컴프레션 웨어 상의 개발)

  • Lee, Junghwa;Jun, Jungil;Choi, Kuengmi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.39 no.2
    • /
    • pp.271-286
    • /
    • 2015
  • This study presented functional designs for development of functional compression wear for men in their forties based on body muscles as well as designed 2D patterns using 3D standard body form data of men in their forties. Patterns with an optimal stretch rate were proposed through a comfort evaluation. Different material was used for different areas such as the sports ability strengthening areas including body parts that often move for sports (such as the shoulders, abdomen and lower arm), areas that require ventilation for perspiration (such as the chest and back center, and armpits), and stable form areas (such as the chest, waist and elbows). The front and back surface areas of the developed pattern was an average 102.4% size compared to the body surface area. The results indicated that the 90% reduction pattern showed changes in pressure value according to area of movement, had the best breathability when worn, and had the best, most comfortable fit compared to the other subjects. The clothing pressure values of the pattern were around 22.1-23.4mmHg for the arm area (which has a big movement range and has many muscles) and 10.4-11.8mmHg for chest and abdomen areas related to major organs and breathing, indicating appropriate clothing pressure. A compression wear top pattern with pressure appropriate to the target age range and excellent appropriateness for the body form will be developed for men in their forties. A study method will be proposed to develop design technology for ergonomic compression wear tops with excellent fit and comfort.

Evaluation of Preference and Wearing Characteristics of Fitness Compression wear for Korean Elderly Women (한국 여성 노인을 대상으로 한 피트니스 압박웨어 선호도 및 착용 특성 평가)

  • Jeon, Eun-Jin;You, Hee-Cheon;Kim, Dong-Mi;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.21 no.3
    • /
    • pp.336-345
    • /
    • 2019
  • This study evaluated the preference and wearing characteristics of existing fitness compression wear for elderly women and identified the problems and improvements of existing fitness apparel. Preference and wearing characteristics for 6 types (A-F) of upper and lower fitness compression wear were evaluated. Photos and drawings as well as the preferred designs and details were investigated after presenting the evaluation clothing. Evaluations were made on a 5 point Likert scale for the fitness, allowance, pressure, ease of movement, fabric material, and overall satisfaction after wearing. The design preference indicated that B type (26.6%) and C type (23.4%) were preferred in the top with C, E and F type preferred to the same ratio of 19.4% in the slacks. The fitness and allowance amount of the top B type were the most appropriate (${\geq}4$), the C type was in close contact (2.86), and the F type was inadequate in the neck circumference (1.77). The feeling of pressure was high in the waist, abdomen, thighs, and knees. The area where the elderly people want to improve their strength was the legs; in addition, a pattern design was needed to strengthen leg muscles when designing fitness compression wear. However, a design with excessive adhesion due to a muscle support band was shown to be not preferred. Therefore, depending on the activity, it is necessary to develop a fitness compression wear that applies an optimum stretching ratio of fabric based on body surface area changes.

Development of a Sizing System of Women's Fitness Wear for the Senior Population in South Korea (한국 노인 여성을 위한 피트니스 압박웨어 치수 개발)

  • Jeon, Eun-Jin;Lee, Won-sup;Park, Jang-Woon;You, Hee-Cheon
    • Fashion & Textile Research Journal
    • /
    • v.20 no.4
    • /
    • pp.464-473
    • /
    • 2018
  • The objective of this study is to develop a sizing system of fitness clothing that can properly accommodate various body sizes of Korean senior women. The sizing system of upper and lower fitness clothing was developed in the present study by selection of key variables, identification of size category candidates, and determination of an optimal sizing system. First, key anthropometric dimensions (stature and bust circumference for upper clothing and stature; waist circumference for lower clothing) were identified by factor analysis on the direct body measurements (n = 272) and 3D whole-body scan data (n = 271) of Korean senior women in Size Korea. Second, sizing system candidates based on the key dimensions of upper and lower clothing were explored using a grid method and an optimization method. Lastly, among the sizing system candidates, optimal sizing systems of upper and lower clothing were selected in terms of accommodation rate. Five size categories (short/small, short/medium, tall/small, tall/medium, and tall/large) were selected as the optimal sizing systems of upper and lower clothing with 89% and 78% of accommodation rate, respectively, for the Korean senior women. The anthropometric characteristics of the representative humans of the optimal size categories would be of use in the design of fitness compressive wear for the better fit and effectiveness of exercise and health of Korean senior women.

Reliability Verification of the Clothing Pressure Meter Utilizing the Arduino Board (아두이노 활용 의복압 측정기 제작 및 신뢰도 검증)

  • Kim, Nam Yim;Park, Gin Ah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.5
    • /
    • pp.723-740
    • /
    • 2022
  • This study aimed to develop an Arduino-based garment pressure device (APD) on the basis of using Single-Tact sensor by suggesting the reliable clothing pressure range and coefficient of selected sensors through the APD calibration process. Once the APD was validated, the pressure of the experimental men's lower body compression wears was measured using the APD and was compared to the pressure measured using the existing air-pack type pressure meter. The subjects were one mannequin and eight men in their 20's, and the trial compression wears were calf sleeves and pants. Clothing pressures were measured in hip, mid-thigh, calf, and ankle. In terms of the 99% confidence level, the experimental clothing pressure measured at the designated measuring points using the APD was considered identical to the one measured using an existing clothing pressure meter. Therefore, on the basis of the experiment results, this study demonstrated that the APD is as reliable as the existing clothing pressure meter within the pressure ranges of 0.54-16.79 kPa and 0.18-25.47 kPa as provided by the SingleTact sensor supplier's data on the basis of using an external ADC (Analog to Digital Converter) module.

Analysis of Body Surface Area by Fitness Motion Using 3D Scan Data of Korean Elderly Female (한국 여성 노인 3D 스캔 데이터를 활용한 피트니스 동작별 체표면적 분석)

  • Jeon, Eun-Jin;Jung, Ha-young;Kim, Hee-Eun;You, Hee-Cheon
    • Fashion & Textile Research Journal
    • /
    • v.22 no.5
    • /
    • pp.650-659
    • /
    • 2020
  • The present study provides reference data required for the design of clothing for the elderly by analyzing the body surface area during fitness motion based on 3D scan data of Korean elderly women. This study was conducted with the procedures of (1) survey of motions and main muscles for fitness, (2) acquisition of 3D scan data, and (3) analysis of rate of change for body surface area during fitness motion. Acquisition of 3D body scan data was obtained from seven elderly females (age: 64-77). We selected 66 anatomical landmarks (40 upper body and 22 lower body) by referring to previous studies. Body surface was segmented by connecting the landmarks marked on the 3D scan data acquired. Analysis of body surface area was conducted in terms of the change rate of surface area in 9 postures of elbow 0°, 90° and 180° for flexion, shoulder 90°, 180° for flexion, shoulder 0°, 180° for abduction, hip 90° for flexion, and knee 90° for flexion compared to the those in the standing posture. The amount of changes in body surface area were 12%-62% in the upper body, 15%-77% in the arm, and 10%-51% in the lower body. A future study on the rate of change of body surface length is needed; in addition, a study on how to apply the results of body surface area and body surface length analysis to clothing pattern design is also necessary.

Foreign Body Reaction after Implantation of a Device for Intervertebral Assisted Motion

  • Seo, Jun-Yeong;Ha, Kee-Yong;Kim, Young-Hoon;Ahn, Joo-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.6
    • /
    • pp.647-649
    • /
    • 2016
  • The device for intervertebral assisted motion (DIAM) is a dynamic implant that consists of a silicone bumper enveloped by a polyethylene terephthalate (PET) fiber sack. Silicone and PET were used because of their biological inertness, but repetitive motion of the spine can cause wear on the implant nonetheless. The purpose of this study is to report a case of foreign body reaction (FBR) against a DIAM. A 72-year-old female patient presented with lower back pain and both legs radiating pain. She had undergone DIAM implantation at L4-5 for spinal stenosis 5 years previously. The intervertebral disc space of L4-5, where the DIAM was inserted, had collapsed and degenerative scoliosis had developed due to left-side collapse. MRI showed L3-4 thecal sac compression and left L4-5 foraminal stenosis. The patient underwent removal of the DIAM and instrumented fusion from L3 to L5. During surgery, fluid and granulation tissue were evident around the DIAM. Histopathology showed scattered wear debris from the DIAM causing chronic inflammation due to the resulting FBR. A FBR due to wear debris of a DIAM can induce a hypersensitivity reaction and bone resorption around the implant, causing it to loosen.

Analysis of Wearing Propensities, Wearing Comfort, Mobility of Movement, and 3D Shape for Advanced Baseball Leg Guards Design (야구 다리보호대 디자인을 위한 착용실태 및 착용감, 운동기능성, 3D 형태분석)

  • Lee, Hyojeong;Eom, Ran-I;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.39 no.1
    • /
    • pp.63-76
    • /
    • 2015
  • This study conducted a survey to gauge the buying and wearing propensities of wearers of leg guards made for baseball catchers, as well as product characteristics of preferred leg guards. Data from the survey were analyzed to obtain basic data for the development of an advanced leg guard design. Degree of compression, horizontal distance, cross section view and outline 3D sketch were also analyzed from the 3D data of leg guards; in addition, mobility and kinematic analysis were conducted through a wearing test. The survey indicated that imported products dominate the current retail market because they are appreciated by customers in terms of fit, price, brand, and protection. Representative complaints of products were discomfort, pressure, and the heavy-weight of the leg guards in general attributed to overall structure and 3D shape. When the pressure was lower on the front area of knee, it feels better to wear and the average knee angular velocity during the up and down motion increased, which suggests a better design from a kinematic point of view. The knee is the primary part of the body responsible for any movement of the lower limbs; consequently, the degree of compression and support stability of the leg guards near the knee area are important factors to evaluate the performance of leg guards. The results of our study indicate significant opportunities for improvement in product design and the development of baseball leg guards along with an ergonomic design that considers the mobility of the knee, skin deformations is necessary to improve performance. The process followed in this study will be applicable to studies on other personal protective equipment for sports.

Effects of Pressurization on Finger's Blood Velocity of Tendon and Muscle Areas in Forearm of 20's male (20대 남성의 아래팔 손목 건영역과 근육영역 가압이 손가락 혈류속도에 미치는 효과)

  • Kim, Nam Yim;Hong, Kyunghi
    • Fashion & Textile Research Journal
    • /
    • v.21 no.4
    • /
    • pp.488-496
    • /
    • 2019
  • This study investigated if the proper pressure level on the wrist tendon area and muscle area of the lower arm are within the same range by examining the responses of blood flow and subjective evaluation. Subjects consisted of 18 males in their 20s, and the experimental bands were custom-made by applying size measurements of each subject. In the experiment, a total of 5 steps were selected by reducing 10 (Step 1) to 50 (Step 5)% from the original body size in the circumferential direction. Blood flow was measured with a sensor attached to the tip of the finger inside the right hand while sitting in a chair for 15 minutes. Blood velocity began to increase (0.82 kPa) when the wrist circumference around tendon area was reduced by 20% (Step 2) and reached its maximum (1.72 kPa) at Step 4. However, the preferred subjective pressure was 1.36 kPa, which was less than the maximum pressure value of 1.72 kPa for Step 4. Blood velocity began to increase when pressure on the muscle area was 1.38 kPa and reached its maximum at 2.16 kPa; however, the most preferred clothing pressure was 1.71 kPa. The results of this study showed that the appropriate pressure level was higher in the muscle area than in the wrist tendon of the lower arm and indicated that graduated compression is favorable.