• Title/Summary/Keyword: Lower anterior teeth

Search Result 204, Processing Time 0.027 seconds

Full mouth rehabilitation of the patient with worn dentition using full-contour monolithic zirconia prostheses at an increased vertical dimension of occlusion: a case report (치아 마모 환자에서 수직고경 증가를 동반하여 단일구조 지르코니아 보철물로 완전구강회복을 시행한 증례)

  • Oh, Kyung-Chul;Chung, Moon-Kyu;Kim, Jee-Hwan;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.198-203
    • /
    • 2012
  • Excessive occlusal wear results in unacceptable damage to the occluding surfaces, and can cause pulpal injury, occlusal disharmony, impaired function, and aesthetic deformity. Patients with severely worn dentition need to be classified as several categories relative to the vertical dimension of occlusion (VDO) and the interocclusal distance for the prosthetic space. When treating patients classified as those who have excessive wear without loss of occlusal vertical dimension but with limited space, we could consider treating them at an increased vertical dimension of occlusion. Treatments at an increased vertical dimension of occlusion may provide stability, given that the amount of its increase was minimal, and a perfected occlusion was achieved after enough stabilization period. A 50-year-old male visited the department of Prosthodontics in Yonsei University Dental Hospital with the chief complaint of worn teeth on lower anterior area. Reconstruction at an increased vertical dimension of occlusion was planned. After the compatibility of the new vertical dimension of occlusion had been confirmed under interim fixed restorations, definitive fixed restorations composed of full-contour monolithic zirconia prostheses were placed. This case presents that a satisfactory clinical result was achieved by restoring the worn dentition at an increased vertical dimension of occlusion with an improvement in esthetics and function.

DISTRIBUTION OF MUTANS STREPTOCOCCI IN DENTAL PLAQUE OF CHILDREN (소아의 치면세균막에 존재하는 mutans streptococci의 분포)

  • Kook, Joong-Ki;Park, Jong-Whi;Yoo, So-Young;Kim, Hwa-Sook;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.439-447
    • /
    • 2004
  • The aim of this study is to survey the frequency of mutans streptococci species and biotypes isolated from dental plaque in Korean children and the relationship between species and biotypes of mutans streptococci and dft index. Dental plaques were collected from the anterior and molar teeth of upper and lower jaws in the subjects, aged below 12 years old. A dental examination was performed for dft (decayed, filled, total) with the WHO caries diagnostic criteria. The mutans streptococci from the sample were cultured selectively on mitis salivarius-bacitracine (MSB) agar plate. For biotyping of mutans streptococci, biochemical test was performed. From the culture, bacterial genomic DNA was prepared for using of PCR template for the identification of mutans streptococci at the species-level. Forty strains of mutans streptococci were isolated from dental plagues of 40 patients. The biotype I (45%) and biotype IV (32.5%) were most frequently detected. The prevalence of S. mutans and S. sobrinus was 69% and 31%, respectively. There was no positive relationship between species and biotypes of mutans streptococci and dft index. Our results revealed that biotype I and S. mutans were frequently detected in Korean children and support that dental caries incidents by many causative factors not only bacterial factor.

  • PDF

A STUDY ON THE EFFECT OF DENTIN BONDING AGENTS APPLIED OVER ENAMEL ABOUT THE BOND STRENGTH OF COMPOSITE RESIN (접착강화제가 치아경조직과의 접착강도 변화에 미치는 영향에 관한 연구)

  • Choi, Woong-Dae;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.1-16
    • /
    • 1995
  • The purpose of this study was to investigate the effect of dentin bonding agents on the bond strength of composite resin restorations in case of applying the dentin bonding agents to acid etched enamel surfaces. Freshly extracted 364 bovine anterior teeth were selected as a adherents. 320 enamel specimens were divided into two groups(unetched group (1) and etched group (2) for testing the shear bond strength, 40 specimens were used for the hardness testing, and 4 specimens of rest were to observe the resin-tag formation into etched enamel surfaces. All surfaces of enamel specimens were polished with 320~1500 SiC paper under continuous running water. In Group (1), 100 enamel specimens were polished and unetched. 220 polished enamel specimens in Group (2) were etched with 37 % phosphoric acid solution for 60 seconds, washed with water for 20 seconds, and dried with a light air pressure for 60 seconds. Three kinds of dentin bonding agents(Gluma, Prisma, Scotchbond 2) were evaluated the effect on the bond strength to conditioned enamel surfaces. Shear bond strengths were measured on the three cases such as a coating of primer only, a coating of sealer only, and a sequential coating of primer and sealer to acid etched enamel surfaces were compared with the bond strengths measured by the coating of enamel bonding agent followed by the bonding of composite resin (Photo clearfil bright, Kuraray, Japan) to unetched and acid etched enamel surfaces. In addition, the hardness tested on the adhesive fractured surface between composite resin enamel as a mean of evaluation of a factor whether the mechanical bond strengths were affected and the penetration of dentin bonding agents into etched enamel surfaces was also observed. Bond strengths were measured using the method of shear bond strength by a universal testing machine (Instron-4467, USA), statistical test were applied to the results using a one way analysis variance(ANOVA), and hardness was measured by the Vicker's Hardness Tester(MHT-i, Matsuzawa, Japan) and the penetration of the resins were observed by the SEM (Hitachi, S-2300, Japan). The following conclusions were drawn; 1. Enamel bonding agent showed to affect the improvement of bond strength of composite resin to enamel surface both unetched and etched. 2. Dentin bonding agents could be resulted in increase of bond strength to unetched enamel surface, but there were no statistical significances. 3. Bond strengths to etched enamel surface were significantly decreased with a coating of dentin primer only. 4. Coating of sealer only and coating of primer and sealer noticed the similar bond strengths of composite resin to etched enamel using the enamel bonding agents. 5. The applying method proved to be more effective than the kinds of dentin bonding agents on the bond strength of composite resin to etched enamel than the kind of dentin. 6. Vicker's hardness numbers of dentin bonding agents were lower than that of composite resin, but the degree of penetration of dentin bonding agents into etched enamel surfaces was excellent.

  • PDF

Retrospective studies of dental implant placement at each intraoral site and situation (임플란트 식립 유형에 따른 후향적 연구)

  • Hong, Ji-Youn;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Chae, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.805-824
    • /
    • 2007
  • Purpose: Developments in micro/macrostructures of implants and surgical techniques brought out stable outcomes of implant dentistry. The aim of this study was to evaluate the distributions of implant patients, the types of implanted sites, and the success or survival rates of various implant systems and to analyze the implant placement done at each specificintraoral site and situation. Materials and Methods: The data of dental implantations collected between 1992 and 2006 at the Department of Periodontology in 00000 University Hospital were analyzed. Results: 1. Largest part of the patients were at the age of 40s and 50s in bothgender who lost their teeth mostly by periodontaldiseases and caries at the posterior intraoral sites as major ones. Bone densities of type II(mandible) and III(maxilla) were likely to be seen with quantity of type B. Lengths of the implants between 10 and 15 mm and wide platform took the largest part. 2. Survival rates of $Implantium^{(R)}(98.8%)$, $Xive^{(R)}(100%)$ and ITI $TE^{(R)}(100%)$ were high when $Frialit-2^{(R)}$ showed 82%(poor bone density area) or 87.2%(combined with additional therapy). $IMZ^{(R)}$ had lowest cumulative survival(67.5%) and success rate(49.4%) amongst all. 3. Replacement with 2 wide or 3 regular platforms showed no significant differences in survival rate and marginal bone loss atmandibular posterior area. In single restoration of mandibular second molar, 5-year success rate of machined surface $Br{\aa}nemark^{(R)}(70.37%)$ was lower than that of rough surface $ITI^{(R)}$ SLA(100%). 4. Replacement of single tooth in anterior area showed high survival rate of 94.5%. 5. The success rates of $Br{\aa}nemark$ Ti-Unite and ITI SLA at posterior maxilla with poor bone density both showed stable outcomes. 6. 10-year cumulative survival rate of implants with maxillary sinus augmentation by lateral window approach appeared to be 96.60%. Low survival rate(75%) was shown when there were more than two complications combined. Height of grafted bone remained stable above the implant apex. Conclusions : Rough surfaced implants showed stable outcomes in most of the situation including poor bone density and additional therapy combined.

EFFECTS OF ACID TREATMENT OF FLUORIDE APPLIED DENTIN SURFACE ON DENTIN BONDING (불소도포한 상아질면의 산처리가 상아질접착에 미치는 영향)

  • Hwang, Hea-Kyung;Ahn, Sik-Hwan;Kim, Sung-Kyo;Jo, Kwang-Hun;Park, Jin-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.602-618
    • /
    • 1996
  • The purpose of this study was to investigate the effect of acid treatment of fluoride applied dentin surface with various concentrations of phosphoric acid for various periods of time on dentin bonding. Dentin specimens prepared from freshly extracted bovine mandibular anterior teeth were divided into fluoridated and nonfluoridated groups. Specimens of nonfluoridated group were pretreated with 10% phosphoric acid for 15 seconds. Those of fluoridated groups were treated with 2% sodium fluoride or 2% stannous fluoride solution for 5 minutes and stored in $37^{\circ}C$ distilled water for 3 days, followed by phosphoric acid treatment. The concentrations of phosphoric acid were 10%, 32% or 50% and the treatment periods of time were 15, 30 or 60 seconds. All the specimens were bonded with All Bond$^{(R)}$ 2 and Bisfil$^{TM}$ composite resin. After bonded specimens were stored in $37^{\circ}C$ distilled water for 24 hours, tensile bond strengths of each specimens were measured and the pretreated dentin and the fractured dentin surfaces were examined under the scanning electron microscope. The results were as follows : The tensile bond strengths from the fluoridated groups were significantly lower than those from the nonfluoridated group when the concentrations of phosphoric acid and the treatment periods of time were equal in all the groups (p<0.05). In general, the higher the concentration of phosphoric acid and the longer the treatment period of time for acid etching on the fluoride applied dentin surface, the higher were the bond strength values. Recovery of bond strength of the dentin bonding agent was better in the NaF applied group than in the $SnF_2$ applied one. SEM findings of NaF applied and $SnF_2$ applied dentin surfaces demonstrated reaction product-covered and partially or completely obstructed dentinal tubules. SEM findings of dentin surfaces fluoridated for 5 minutes followed by etching showed wider tubular openings and more clean dentin surfaces when dentin was etched with higher concentration of phosphoric acid for longer period of time. On the SEM observations of the fractured dentin-resin interface, the etched specimens of fluoridated group showed an adhesive failure mode when the concentration of phosphoric acid and the treatment period of time were same as in the nonfluoridated group. As the concentration of phosphoric acid and the treatment period of time increase during acid etching, the cohesive failure area increased. However, excessive acid etching caused adhesive failure.

  • PDF

THE STDUY OF THE RELAPSE OF HARD AND SOFT TISSUE AFTER MAXILLARY PROTRACTION (상악골 전방견인 후 경조직과 연조직의 재발에 관한 연구)

  • Yang, Jun-Ho;Park, Soo-Byung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.27 no.3 s.62
    • /
    • pp.373-389
    • /
    • 1997
  • The purpose of this stdudy was to evaluate the effect of maxillary protraction and the relapse of hard and soft tissue after maxillary protraction. For this study 29 patients who were treated with maxillary protractor and labiolingual archwire were selected. Their mean age was 9 years 4 months and mean treatment period was 8.5 months. Lateral cephalograms were taken at pretreatment, immediately after treatment and one to three months after removal of the maxillary protractor. They were traced on skeletodental and soft tissue structures based on Burstone's analysis and analyzed by Quick-Ceph Image Digitizing System(ORTHODONTIC PROCESSING). The mean and standard deviation between pretreatment and posttreatment and between posttreatment and retention period for each cephalometric variable were calculated. Student t-test was used to determine the statistical significance of the changes in each variable. Correlation coefficients between hard tissue and soft tissue were used to determine interrelationship. The results were as follows. 1. After maxillayy protraction, the maxilla and maxillary dentition moved antero-inferiorly, the mandibld and mandibular dentition moved postero-interiorly and palatal plane rotated antero-superiorly by $0.59^{\circ}$. 2. After maxillary protraction, the soft tissue of upper lip moved antero-interiorly with the movement of hard tissue but the antero-posterior position of lower lip was stable in spite of the change of hard tissue. The thickness of upper lip was decreased and that of lower lip was increased after maxillary Protraction. 3. During the retention period, the position of jaws was relatively stable but upper and lower anterior teeth and antero-superiorly rotated palatal plane relapsed to original position. 4. During the retention period, the soft tissue of lips was stable antero-posteriorly and moved mote inferiorly than posttreatment. 5. The correlation coefficients between the postion of upper and lower incisal edge and that position of lips were high, especially in horizontal change.

  • PDF

A STUDY OF DENTAL CROWDING AND ITS RELATIONSHIP TO MANDIBULAR INCISOR SHAPE BY MODEL ANALYSIS IN ADOLESCENTS (청소년 석고 모형 분석에 의한 하악절치 형태와 치아밀집의 상관관계에 관한 연구)

  • Surh, Jeong-Eun;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.593-604
    • /
    • 1995
  • Mandibular incisor crowding is one of the most common features of malocclusion and is interesting characteristic in view of relapse and stability after orthodontic treatment. There are many potential factors in the etiology of lower anterior crowding. The tooth size variation is one of them, but biologic significance for the faciolingual width of the teeth has been overlooked. Peck and Peck reported that persons with ideal mandibular incisor alignment were shown to have incisor with smaller mesiodistal and larger faciolingual dimensions than persons with incisor crowding. On the basis of these findings they suggested MD/FL index as a clinical guideline for the assessment for lower incisor crowding. The present study was undertaken to examine the relationship between mandibular incisor crowding and mandibular incisor dimension, and determine their correlation with arch length discrepancy. 154 dental casts of people from 11 to 17 years of age were made, and were divided into normal group with irregularity index less than of 1, and crowding group with irregularity index greater than 1.The casts were measured and analyzed statistically. The results were as follows. 1. The mean mesiodistal width for mandibular incisor was larger in crowding group, and has significant difference in central inciosr measurement. There are no significant differences in the faciolingul width and MD/FL index. 2. Irregularity index has significant correlation coefficients with mesiodistal width and MD/FL index for mandibular incisor in crowding group, but no correlation with faciolingual width. It also has correlation with maxillary and mandibular arch length discrepancy, total tooth material, mandibular intercanine width, and mandibular inter first premolar width. 3. Upper and lower arch length discrepancy have significant correlation with mesiodistal width of mandibular incisor and overbite, but have no correlation with faciolingual width. Lower arch lenth discrepancy has significant correlation with MD/FL index for mandibular incisor and upper arch length discrepancy has correlation with MD/FL index for mandibular lateral incisor. 4. Significant differences were observed between normal and crowding group for the mandibular arch length discrepancy and overbite.

  • PDF

Shade Comparative Analysis of Natural tooth Measured by Visual and Two Colorimeters(ShadeEye®,Shadepilot®) (2종 측색기와 시각을 이용한 자연치아의 색조 비교 분석)

  • An, Jin-Hee;Choi, Mee-Ra;Shim, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.81-93
    • /
    • 2013
  • The objectives were to evaluate the accuracy of shade selection by human visual system(VS) and 2 different colorimeters ($ShadeEye^{(R)}$(SE) and Shadepilot (SP)). Maxillary anterior teeth of 30 volunteers which had no caries or restorations were included in the study. Firstly, the accordance in shade selection by 3 dentists and 2 colorimeters was investigated. Secondly, the color of the teeth were measured by 1 observer's naked eye and 2 colorimeters under different illumination conditions (Sunny versus cloudy day). Additionally testing of inter-observer variability selected colors by 2 novice and 2 experienced dentists were compared. For comparing visual and 2 different colorimeters, SP(60%) showed significantly highest rate of accordance than the visual (23.3%) or SE (16.7%) and lowest mean ${\Delta}E$ ($2.62{\pm}0.74$ versus $3.83{\pm}1.38$;SE or $4.04{\pm}1.61$;VS)(p<0.001). If accuracy of shade selection were measured using VS, the mean ${\Delta}E$ value of cloudy day was higher than that of sunny day ($4.35{\pm}1.70$ versus $3.53{\pm}1.31$; p<0.001). There were no significant difference of the mean ${\Delta}E$ value between sunny and cloudy day in both SE and SP. Inter- observer repeatability was higher in 2 experienced group (73.3%) than novice group (36.7%). The mean ${\Delta}E$ of experienced group was lower than that of novice group ($3.60{\pm}1.47$ versus $4.70{\pm}1.67$; p<0.001). Colorimeters (SE or SP) is more accurate and more reproducible compared with human shade assessment. Using visual system may be limited by cloudy and inexperience of tester, then more experience and using colorimeters may be helpful of raising the accurate repeatability of shade selection.

An in vitro study of a few crystal growth solutions on the bracket shear bond strength (수종의 실험 결정형성용액에 의한 브라켓 전단결합강도의 비교)

  • Jeon, Yun-Ok;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.613-625
    • /
    • 1999
  • The purpose of this study was to compare the bracket shear bond strengths of the crystal growth solutions with those of the $37\%$ phosphric acid etch technique. The 4 crystal growth solutions were made experimentally in the lab, that is, (1) $30\%$ polyacrylic acid solution containing 0.3 M sulfuric acid (ES 1), (2) $30\%$ polyacrylic acid solution containing 0.6M sulfuric acid (ES 2), (3) $30\%$ polyacrylic acid solution containing 0.3 M sulfuric acid and 0.6 M lithium sulfate(ES 3), and (4) $30\%$ polyacrlic acid solution containing 0.3 M sulfuric acid and $5\%$ phosphoric acid(ES4). The $37\%$ phosphoric acid solution used as a control. Bovine lower incisor tooth enamel was treated by the above solutions for 60 sec, washed out for 20 sec with slow water stream, and bonded lower anterior edgewise bracket with the light curing orthodontic composite resin adhesives. The teeth bonded brackets were stored in the distilled water at room temperature for 24 h, and followed to test the bracket shear bond strength. The acid etch technque showed 177.6 kg/$cm^2$ of mean shear bond strength which was the highest among the enamel treatment solutions. ES 1 shown 58.4 kg/$cm^2$ of mean shear bond strength and that of ES 4 showed 66.5 kg/$cm^2$. There was no significant difference between the two(p>0.05). ES2 showed 110.6kg/$cm^2$ of mean shear bond strength which was $62.3\%$ of that of acid etch technique. ES 3 showed 131.1 kg/$cm^2$ of mean shear bond strength which was the highest among experimental crystal growth solutions and which was $74\%$ of that of acid etch technique. The shear bond strengths of the crystal growth solutions were significantly lower that that of acid etch technique(p<0.05). The results sugest that although bracket shear bond strength of $30\%$ polyacrylic acid solution containing 0.3M sulfuric acid and 0.6 M lithium sulfate were showed the highest, it is low for the clinical application of this solution.

  • PDF

BOND STRENGTH OF BONDED AMALGAM USING DENIAL ADHESIVES (치과용 접착제를 사용한 접착 아말감의 결합 강도)

  • Kam, Dong-Hoon;Lee, Sang-Dae;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.284-295
    • /
    • 1999
  • The purpose of this study was to measure and analyze the bond strength of bonded amalgam using dental adhesives and to compare this with light-curing composite resin. Sections 8mm in diameter were punched out from the labial surface of bovine anterior teeth. These were embedded in clear acrylic resin blocks with labial surface facing out. 55 specimens were made for enamel and dentin each. After dividing these into 5 groups, group 1: Superbond C&B, group 2: Panavia 21, group 3: All-Bond 2, group 4: Fuji I Glass Ionomer Luting Cement, group 5: Scotchbond Multi-Purpose(Restorative Z-100), molds with holes of 6.3mm in diameter and 1.5mm in depth were placed over the specimens. The exposed tooth surfaces were treated with adhesives and the molds were filled with amalgam. In group 5, the mold was filled with composite resin and light-cured for 40 seconds. The author measured all specimens for bond strength 24 hours after amalgam filing and analyzed fracture surfaces. The following results were obtained: 1. Among the dentin groups, groups 1, 2 and 4 showed significantly lower bond strength compared with group 5(P<0.05). 2. Among the enamel groups, group 4 showed significantly lower bond strength compared with group 5(P<0.05). 3. In group 2, 2D showed significantly lower bond strength compared with group 2E(P<0.05). Other adhesives showed no such differences in bond strength between dentin and enamel(P>0.05). 4. Cohesive failure was observed in groups 1E and 5D, while mixed failure was seen in groups 1 and 5. Only adhesive failures were noted in groups 2, 3, 4.

  • PDF