• Title/Summary/Keyword: Lower Tooth

Search Result 682, Processing Time 0.023 seconds

Difference of dental erosive potential according to the type of mixed drink (혼합주의 종류에 따른 치아의 부식능 차이 평가)

  • Kim, Young-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.739-744
    • /
    • 2020
  • This study evaluates the erosive potential and effects of mixed alcohols by analyzing the pH, titratable acidity, and fluorescence loss degree (△F). Following alcohol groups were investigated: Soju, Calamansi+soju, Yakult+soju, Cola+soju, and Energy drink+soju. The ratio of soju:beverage in the alcohol mixtures was 7:3. Ed. Notes: The sentence lacks clarity. Please review if the edit correctly portrays the meaning. If not, please revise appropriately. Measurement of the pH and titratable acidity (the amount of 1M NaoH solution required to raise to pH 5.5 (TA5.5) and 7.0 (TA7.0)) of alcohols was achieved by stirring with pH meter. The erosive effect of the alcohol mixtures on bovine tooth (△F) after 1, 2, 4, and 6 hours exposure were analyzed by quantitative light-induced fluorescence (QLF-D). All the mixed alcohols in this study showed an acidic pH, lower than 4.5. The average pH of mixed alcohols was 3.17 ± 0.50 whereas the pH of Soju was 8.6 ± 0.01. The TA5.5 and TA7.0 values of the mixed alcohols were 0.5~18 and 0.5~23.5, respectively. △F of the three tested mixed alcohol groups (except yakult+soju group) were observed to increase in a time-dependent manner. The calamansi mixed alcohol had the highest acidity potential and erosive effect among the tested groups. Taken together, the results indicate that the mixed alcohols have a strong erosive effect and potential on dental enamel.

THE EFFECTS OF DENTIN BONDING AGENT THICKNESS ON STRESS DISTRIBUTION OF COMPOSITE-TOOTH INTERFACE : FINITE ELEMENT METHOD (상아질 접착제의 두께가 치아와 복합레진 경계의 응력발생에 미치는 영향에 관한 유한요소법 연구)

  • Park, Sang-Il;Kim, Ye-Mi;Roh, Byoung-Duk
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.442-449
    • /
    • 2009
  • The aim of this study was to examine that thick dentin bonding agent application or low modulus composite restoration could reduce stresses on dentin bonding agent layer. A mandibular first premolar with abfraction lesion was modeled by finite element method. The lesion was restored by different composite resins with variable dentin bonding agent thickness ($50{\mu}m$, $100{\mu}m$, $150{\mu}m$). 170N of occlusal loading was applied buccally or lingually. Von Mises stress on dentin bonding agent layer were measured. When thickness of dentin bonding agent was increased von Mises stresses at dentin bonding agent were decreased in both composites. Lower elastic modulus composite restoration showed decreased von Mises stresses. On root dentin margin more stresses were generated than enamel margin. For occlusal stress relief at dentin boning agent layer to applicate thick dentin bonding agent or to choose low elastic modulus composite is recommended.

The Influence of Different Gypsum Materials on the Accuracy from Complete Arch Digital Impression (전악의 디지털 인상 채득 시 치과용 모형재가 디지털 모형 정확성에 미치는 영향)

  • Kim, Ki-Baek;Lee, Gyeong-Tak;Kim, Hae-Young;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.617-623
    • /
    • 2012
  • This study was performed to measure the accuracy of different gypsum materials by a white light dental scanner. A master model with the prepared lower full arch tooth was used. The type IV and scannable stone were used for 20 stone casts (10 casts each) duplicated a master model of mandible. The distance between the reference points were measured and analyzed by the Delcam $Copycad^{(R)}$ (Delcam Plc, UK) 3D graphic software. The t-student test for paired samples were used for statistical analysis. The mean differences to master model for type IV stone and scannable stone model were 0.29~0.56 mm, and 0.17~0.35 mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between the master model and type IV/scannable stone (p<0.05). Two different gypsum materials showed clinically acceptable accuracies of full arch digital impression produced by them. Besides, in both gypsum materials, the differences to the master model detected appear to provide enough accuracy for clinical application.

Comparison of Dental Biofilm Reduction between Rolling Method and Modified Stillman Method (회전법과 변형스틸맨법의 치면세균막 감소 효과 비교)

  • Han, Ye-Seul;Lim, Soon-Ryun;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.660-665
    • /
    • 2012
  • The purpose of this study was to use basic data of dental hygiene curriculum by comparing the rolling method and modified stillman method. Plaque measurement method, Q-ray examination of the clinical utilization value shall review. True experimental design is randomized controlled trial to the intervention group and the control group. Measurements are plaque control record (PCR; O'Leary index) measurements and Quantitative Light induced fluorescnece Digital (QLFD) shooting as a pre-test was conducted. Intervention group is modified stillman method, control group is rolling method. Intervention after 5 weeks, PCR measurement and QLFD shooting was carried out as a post-test. Rolling method and modified stillman method plaque reduction did not differ. Intervention before and after the results of the comparison showed reduced plaque score after brushing law education. Also, Plaque reduction differences were more pronounced modified stillman method than rolling method. PCR and QLFD values of the correlation was not confirmed but SPS Score and the lower value of the ${\Delta}R$ value of the correlation. Plaque of maturity tooth that are not observed visually.

Full-mouth rehabilitation with implant-supported fixed dental prostheses for the edentulous maxilla and partially edentulous mandible: A case report (상악 완전 무치악 및 하악 부분 무치악 환자에서 임플란트 지지형 고정성 보철물을 이용한 전악 수복 증례 보고)

  • Kim, Tae-Hyung;Oh, Kyung-Chul;Moon, Hong-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.374-381
    • /
    • 2019
  • A conventional approach for the treatment of long-span edentulous areas is the use of removable dentures. However, placing implants in these areas results in superior functional outcomes by increasing the stability, support, and resistance of the prostheses and improving the masticatory efficiency. Treatment modalities utilizing implants can be further classified into either removable or fixed-type prostheses. Several factors such as the amount of alveolar bone resorption, inter-arch relationship, patient preferences, and socioeconomic status should be considered when determining the appropriate treatment approach. Monolithic zirconia has been considered a suitable material for implant-supported fixed dental prosthesis, because of the drastic improvement in its mechanical properties. It exhibits fewer incidences of fracture and chipping of the prostheses, and has greater bulk of material than metal-ceramic crowns and zirconia-veneered ceramics. Moreover, highly translucent monolithic zirconia is also available in the market, and its application is gradually increasing for anterior tooth rehabilitation. The present report describes a patient who underwent full-mouth rehabilitation with fixed dental prostheses (eight upper and three lower implant placements). All teeth, except bilateral mandibular canines and left mandibular first and second premolars, were extracted after the diagnosis of generalized chronic moderate-to-advanced periodontitis of the remaining teeth. The patient reported satisfactory esthetic and functional outcomes during the one-year follow-up visit.

Generalized Short Root Anomaly with Various Dental Anomalies : A Case Report with a 5 - Year Follow - up (치아 이상을 동반하는 전반적인 Short Root Anomaly (SRA) : 5년간의 추적 관찰)

  • Yu, Dayeol;Kim, Donghyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.122-128
    • /
    • 2021
  • Short root anomaly (SRA) is a rare dental condition with abnormally short and blunt root morphology. It mostly affects maxillary central incisors symmetrically and only has been observed in permanent teeth. A 9-year-old girl was referred from a local dental clinic for short root development in mixed dentition with no symptoms. Radiographic and intraoral examinations revealed SRA on upper and lower incisors and mandibular first molars along with other dental anomalies such as enamel hypoplasia and dens invaginatus. During long - term follow - up for 5 years, her mixed dentition has changed to permanent dentition and generalized SRA was observed in all permanent teeth. Cephalometric radiograph also revealed the calcification between the anterior and posterior clinoid processes described as a sella turcica bridge which was reported associating with dental anomalies. Early diagnosis of SRA is emphasized for successful management and prevention of root resorption and tooth loss. This report aimed to present a rare case of generalized SRA along with other dental anomalies and sella turcica bridging in a female patient through long - term follow - up.

DENTAL MANAGEMENT OF A 46-MONTH-OLD CHILD WITH PRADER-WILLI SYNDROME : A CASE REPORT (프래더-윌리 증후군을 가진 46개월 소아의 치과치료 : 증례보고)

  • Choi, Kyung Hwa;Kim, Mi Sun;Nam, Ok Hyung;Lee, Hyo-Seol;Choi, Sung Chul;Kim, Kwangchul
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.15 no.1
    • /
    • pp.29-34
    • /
    • 2019
  • Prader-Willi Syndrome (PWS) is a rare neurologic disorder with a prevalence 1/10,000-30,000. The cause of PWS is an abnormalities of chromosome 15q11.2-q13 which is an imprinting gene. Obesity and hyperphagia are characteristic features on a PWS adult. On the other hand, the birth weight, height and body mass index (BMI) of PWS infants are 15-20% lower than those of normal babies and there is a failure to thrive until 24-month-old. Most of PWS patients are treated under general anesthesia and conscious sedation. This case is a treatment of severe caries in a PWS 46 month-old child without general anesthesia and conscious sedation. He came to the Department of Pediatric Dentistry, Kyung Hee University Dental Hospital at Gangdong, Seoul, Korea with a trauma history. He had a medical history with heart surgery and needed to take antibiotics prophylaxis. The luxated left upper primary tooth were removed and caries treatment were done as an outpatient without general anesthesia, conscious sedation.

Implant-supported fixed prostheses with high-performance polymer (PEKK) abutments in partial edentulous patients: A case report (부분 무치악 환자에서 고기능성 폴리머(PEKK) 지대주를 이용한 임플란트 고정성 보철물 수복 증례)

  • Ha, Seung-Ryong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.71-78
    • /
    • 2021
  • Implant treatment, which was first attempted in fully edentulous patients, is now widely used in partially edentulous, and a single tooth missing patients. Moreover, implant treatment has become an essential treatment modality in modern dentistry. The material of fabricating implant prostheses has also become more diverse than before, one of which is the use of high-performance polymers. The frequency of using high-performance polymers, which have been used in the medical field, is also increased in the dental field compared to the past. In the first case, a PEKK abutment and a PFG crown (cement-screw-retaining type) were fabricated in the lower left second premolar, and in the second case, a PEKK abutment and a monolithic zirconia crown (cement-screw-retaining type) were fabricated in the missing upper left first molar, and in the third case two PEKK abutments and a splinted PFM crowns (cement-screw-retaining type) were fabricated and connected to the upper right first and second molar implants. Through these procedures the patients obtained esthetically and functionally satisfactory results after 4 years of follow-up.

Approach to prosthetic treatment for patients with open bite due to mandibular displacement: Case report (하악변위로 인한 개방교합 환자의 보철치료: 증례보고)

  • Seo, Min-Gyung;Chi, Seung-Seok;Ko, Kyung-Ho;Park, Chan-Jin;Cho, Lee-Ra;Huh, Yoon-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.420-430
    • /
    • 2022
  • Open bite is accompanied by decrease in tooth contact and overbite, and causes collapse of occlusal plane, mastication difficulties, speech disorders, changes in appearance, and lower occlusal force than normal. Open bite caused by temporomandibular joint disorder in adults with complete occlusion must be corrected after removal or stabilization of the causative factors. Orthodontic treatment, occlusal adjustment, prosthetic treatment, and surgical treatment can be the option of occlusal correction. This report describes about estimating the cause of occlusion change in two patients who developed an open bite due to mandibular displacement in adults with complete occlusion and different treatment approaches accordingly. In one patient, satisfactory result was obtained in functional and esthetic aspects through occlusal adjustment after stabilization of the temporomandibular joint.

Impact of lattice versus solid structure of 3D-printed multiroot dental implants using Ti-6Al-4V: a preclinical pilot study

  • Lee, Jungwon;Li, Ling;Song, Hyun-Young;Son, Min-Jung;Lee, Yong-Moo;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.4
    • /
    • pp.338-350
    • /
    • 2022
  • Purpose: Various studies have investigated 3-dimensional (3D)-printed implants using Ti6Al-4V powder; however, multi-root 3D-printed implants have not been fully investigated. The purpose of this study was to explore the stability of multirooted 3D-printed implants with lattice and solid structures. The secondary outcomes were comparisons between the 2 types of 3D-printed implants in micro-computed tomographic and histological analyses. Methods: Lattice- and solid-type 3D-printed implants for the left and right mandibular third premolars in beagle dogs were fabricated. Four implants in each group were placed immediately following tooth extraction. Implant stability measurement and periapical X-rays were performed every 2 weeks for 12 weeks. Peri-implant bone volume/tissue volume (BV/TV) and bone mineral density (BMD) were measured by micro-computed tomography. Bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were measured in histomorphometric analyses. Results: All 4 lattice-type 3D-printed implants survived. Three solid-type 3D-printed implants were removed before the planned sacrifice date due to implant mobility. A slight, gradual increase in implant stability values from implant surgery to 4 weeks after surgery was observed in the lattice-type 3D-printed implants. The marginal bone change of the surviving solid-type 3D-printed implant was approximately 5 mm, whereas the value was approximately 2 mm in the lattice-type 3D-printed implants. BV/TV and BMD in the lattice type 3D-printed implants were similar to those in the surviving solid-type implant. However, BIC and BAFO were lower in the surviving solid-type 3D-printed implant than in the lattice-type 3D-printed implants. Conclusions: Within the limits of this preclinical study, 3D-printed implants of double-rooted teeth showed high primary stability. However, 3D-printed implants with interlocking structures such as lattices might provide high secondary stability and successful osseointegration.