• Title/Summary/Keyword: Lower Cooling

Search Result 966, Processing Time 0.026 seconds

Numerical Analysis of Simultaneous Cooling Process of Upper and Lower Side of Running Hot Steel Strip (주행하는 고온 강재의 상하부 동시 냉각 과정 수치해석)

  • Kwon, Myeon Jae;Park, Il Seouk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.1051-1056
    • /
    • 2014
  • After hot rolling, a high-temperature steel plate with a temperature higher than $800^{\circ}C$ is rapidly cooled by multiple circular water jets. In this cooling process, because the temperature of the steel plate is much higher than the boiling point of the cooling water, film-boiling heat transfer occurs and a very thin steam layer forms between the plate surface and the cooling water. The steam layer acts as a thermal resistance that prevents heat transfer between the cooling water and the steel plate. In addition to the film-boiling heat transfer, complex physical phenomena such as the free-surface flow of residual water that accumulated on the material and the material's high-speed motion also occur in the cooling process. In this study, the simultaneous cooling process of the upper and lower sides of a running hot steel strip is investigated using a three-dimensional numerical model and the cooling performances and characteristics of the upper-side cooling and lower-side cooling are compared.

A Feasibility Study on In-Vessel Core Debris Cooling through Lower Cavity Flooding

  • Yang, Soo-Hyung;Baek, Won-Pil;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.309-314
    • /
    • 1996
  • Feasibility study has been accomplished to evaluate the effectiveness of the in-vessel core debris cooling through lower cavity flooding using two dimensional finite difference scheme. The volume of cerium pool and decay power rate generated in corium pool were evaluated as important parameters to the temperature distribution on the reactor vessel lower head through previous works. In this study, the corium volume based on the System 80+ core structure and time dependent decay power rate are considered for feasibility evaluation. In addition, preliminary plans for the in-vessel core debris cooling through lower cavity flooding as severe accident management strategy, i.e. flooding timing, method and capacity, are suggested based on the result of the numerical study, international tendency related to in-vessel core debris cooling through lower cavity flooding.

  • PDF

Estimating the Air Temperature Cooling Effect of the Cheonggyechun Stream Restoration Project of Seoul, Korea

  • Park Chong-Hwa;Kwon Young-Sang
    • Journal of the Korean Institute of Landscape Architecture International Edition
    • /
    • no.2
    • /
    • pp.120-129
    • /
    • 2004
  • Urban stream restoration projects can improve water quality, wildlife habitats, urban landscape, outdoor recreation spaces, and urban microclimate. The objectives of this research were to investigate temperature cooling effect of urban streams by using satellite imagery, to evaluate environmental variables related to stream cooling effect, and to estimate the cooling effect of the Cheonggye stream restoration project of Seoul, Korea. Findings of this research can be summarized as follows. First, a method of estimating temperature distribution around urban streams by using satellite imagery was developed. Scatter plots of distance from stream edges and average temperature obtained through multiple buffering were used for the estimation. Second, urban temperature cooling effect of streams was estimated by comparing background temperature and temperature of each buffer zone. Third, environmental factors affecting stream cooling effect were also identified. Fourth, the temperature cooling effect of the restoration project was estimated based on three scenarios. An estimated cooling effect based on the average cooling effect of existing tributaries showed the most significant effect; $2.0^{\circ}C$ lower than the present level at the edge of the renovated stream. It was estimated that the temperature of the same area would be $1.4^{\circ}C$ cooler than the present level if the cooling effect of the Yangjaechun was used as the bench mark But the effect would be $1.2^{\circ}C$ lower than the present level if environmental variables related to the temperature cooling effect of urban streams were used as the bench mark.

  • PDF

A study on an improvement of indoor cooling tower efficiency (지하역사 실내형 냉각탑 성능개선 연구)

  • Bae, Sung-Joon;Hwang, Sun-Ho;Shin, Chang-Hun;Pyo, Soo-Chul
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1726-1735
    • /
    • 2008
  • Seoulmetro has operated the air cooling equipment for 57 stations to improve services focused on our customers who use Seoulmetro during the summer season and has established every year. However, a new set of problems has arisen with the cooling tower to support a heat exchange of cooling water. The most important matter is loss of efficiency in the cooling tower. The leading cause of this problem is that we use an indoor type. As the cooling tower room is located in the underground of the city because of the residents near the station. Therefore It is difficult to establish the cooling tower on the ground. But it is unsuitable for the location requirements of the underground type because it has a limited space to set up the air cooling equipment, for example, the cooling tower and a ventilating opening. As a result of such an unfavorable condition, the cooling tower doesn't work efficiently and the warmth of cooling water because of insufficiency of a heat exchange and a refrigerator's technical obstacle such as a high-temperature and a high-pressure has arisen. To prevent this situation, the operator tend to reduce refrigerant. Accordingly, the efficiency of the air conditioning is getting lower and lower. Study wishes to analyze the matter to improve indoor cooling tower efficiency and recommend a best practice for a person who manage the establishment.

  • PDF

Development of Cooling Garment for Extremely Hot Environment Using a Peltier Device and its Comfort Properties (고온환경 작업을 위한 펠티어 소자 냉각복 개발 및 쾌적성 평가)

  • Jung, Ye-Lee;Chae, Young-Jin;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • This paper reports on a prototype cooling garment applying a cooling module. The cooling module was composed of a Peltier device, a cold sink, a heat sink and two fans. A constant box was used to evaluate the cooling effect of the module. Two cooling modules were attached on each side of the garment. The wear trial was conducted using 10 male subjects in an environmental chamber maintained at $30{\pm}0.5^{\circ}C$, $50{\pm}5%$RH. Subjective sensations of thermal, humidity, and comfort were surveyed. Statistical package SPSS12.0 was used for the t-test and the Wilcoxon signed-rank test. The results showed that most effective cooling module decreased the temperature of the constant temperature box by $-4.9^{\circ}C$. The micro-temperature of the cooling garment with a Peltier device was lower than the control garment during the exercise. In particular, the chest skin temperature was $1.5^{\circ}C$ lower with the cooling garment than the control. The maximum temperature difference was $-2.57^{\circ}C$ on the sides of the $1^{st}$ layer. Subjective thermal sensation from wear trials of the Peltier device attached garment was lower than the control garment. Subjects felt more comfortable with the cooling garment in almost all the periods.

The study on heat transfer enhancement using indirect cooling system in the channel with heat source (간접냉각방식을 이용한 열원이 부착된 채널내의 열전달 촉진에 관한 연구)

  • 김광추;박만흥;윤준규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.321-331
    • /
    • 1999
  • A numerical study is carried out for increasing heat removal using indirect cooling system. Computation is performed for nine cases as variation of flow condition in the lower channel. As the result of this study, water is more effective than air at the same pressure loss in spite of the lower inlet velocity. In channel configuration, the vertical channel is more effective than horizontal channel because of the buoyancy effect. Under the condition that heat generation is the same, counter flow effectively decreases the temperature difference among blocks. Parallel flow is more effective than counter flow when average temperature of all blocks is considered. In the case of installing obstacles in the lower channel, it is desirable to install obstacles in the bottom of lower channel. Heat transfer rate increases as the height of obstacles increases.

  • PDF

An Experimental Study on the Low-Temperature Behavior of Stratified Fluids in the Square Cavity (저온에서 정방형 공간내 성층화된 유체의 열적거동에 관한 실험적 연구)

  • 강한용;이동석;김병철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.381-387
    • /
    • 2000
  • An experimental study on the stratified fluids was carried out to investigate the flow characteristics, heat transfer through the interface of fluids, and the applications of thermal behaviors in the square cavity. The same volume of water and silicon oil was filled in it. The experiments were performed with the variations of initial temperatures and cooling surface temperatures. And the effect of vertical or horizontal cooling surface positions in the square cavity was investigated. When the cooling surface temperatures were $-4^{\circ}C$ , the supercooling phenomena were observed for both cases of cooling surface positions in the full region regardless of the initial temperature of fluid. In the square cavity with horizontal cooling surfaces, the lower the initial temperatures were, the longer the supercooling durations were, and with vertical cooling surface the lower the initial temperatures were, the shorter the supercooling durations were.

  • PDF

Cooling performance of an electronic system including electronic components mounted with heat sink (히트 싱크 부착 전자부품을 가진 통신시스템의 냉각성능 연구)

  • No, Hong-Gu;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.2
    • /
    • pp.253-266
    • /
    • 1998
  • A numerical study on the cooling performance for electronic components mounted with heat sink in an electronic system has been performed. The model of electronic system consisted with lower and upper modules in which the electronic components mounted with heat sink were arrayed. To find better configuration under a given fan power for effective cooling, the cases called 'No heat sink','Both heat sinks','Lower heat sinks', and 'Upper heat sinks' were tested. The results showed that the cooling performance in 'Upper heat sinks' was the best among four cases.

Developing Liquid Cooling Garments to Alleviate Heat Strain of Workers in Summer and Exploring Effective Cooling Temperature and Body Regions (여름철 작업자들의 고체온증 예방을 위한 액체냉각복 개발 및 효과적인 냉각온도와 인체 냉각부위 탐색)

  • Jung, Jae-Yeon;Kang, Juho;Seol, Seonhong;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.22 no.2
    • /
    • pp.250-260
    • /
    • 2020
  • The purpose of the present study was to explore the most effective body region and cooling temperature to alleviate heat strain of workers in hot environments. We developed liquid cooling hood, vest, sleeves and socks and applied the water temperatures of 10, 15, 20, and 25℃ through the liquid cooling garments in a hot and humid environment (33℃ air temperature and 70% RH air humidity). A healthy young male participated in a total of 16 experimental trials (four cooling garments × four cooling temperatures) with the following protocol: 10-min rest, 40-min exercise on a treadmill and 10-min recovery. The results showed that rectal temperature, mean skin temperature, and ratings of perceived exertion during exercise; heart rate and diastolic blood pressure during recovery; and total sweat rate were lower for the vest condition than other garment conditions(p < .05). However, there was no differences in mean skin temperature among the four cooling garments when we compared the values converted by covering area(%BSA). When we classified the results by cooling temperature, there were no consistent differences in thermoregulatory and cardiovascular responses among the four temperatures, but 25℃ water temperature was evaluated as being the most ineffective cooling temperature in terms of subjective responses. In conclusion, the results indicated that wearing cooling vest with < 20℃ cooling temperature can alleviate heat strain of workers in hot and humid environments. If the peripheral body regions are cooled with liquid cooling garments, larger cooling area with lower cooling temperature than 10℃ would be effective to reduce heat strain of workers. Further studies with a vaild number of subjects are required.

Effects of Local Cooling on Heat Strain in the Hot Environment -On the Trunk Region-

  • Hwang, Kyoung-Sook;Choi, Jeong-Wha;Lee, Kyung-Suk
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.3
    • /
    • pp.211-216
    • /
    • 2007
  • This study was to determine the effect of cooling part of the trunk without harm for the health. The results provide basic data for the development of clothing which could increase work efficiency and reduce body strain in hot environment. Eight males took part in the study. The experiment was conducted in a climate-chamber controlled with $37{\pm}1^{\circ}C,\;50{\pm}5%R.H$. The trunk was divided into six areas to be cooled: head, neck, chest, abdomen, the upper back, the lower back. According to preceding studies, permissible safety cooling limits of skin temperature, of each part of the trunk for four hours cooling were $25^{\circ}C$ on the head, $20^{\circ}C$ on the neck, $27^{\circ}C$ on the chest, $25^{\circ}C$ on the abdomen, $20^{\circ}C$ on the upper back, $20^{\circ}C$ on the lower back. So cooling temperatures of each region set up temperatures above mentioned. In conclusion, the head, the neck and the upper back cooling could reduce sweating amount, rectal temperature and heart rates and reduce the heat stress of workers exposing in the hot environment by decreased subjective sensations of heat and comfort. Thus, it was concluded that effectiveness of cooling among the trunk was best on the head and the neck.