• Title/Summary/Keyword: Low-temperature Design

Search Result 1,400, Processing Time 0.032 seconds

Climate Change and Health - A Systemic Review of Low and High Temperature Effects on Mortality (기후변화와 건강 - 저온과 고온이 사망에 미치는 영향에 관한 체계적 고찰)

  • Lim, Youn-Hee;Kim, Ho
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.6
    • /
    • pp.397-405
    • /
    • 2011
  • Objectives: The impact of climate change on the health has been of increasing concern due to a recent temperature increase and weather abnormality, and the research results of the impact varied depending on regions. We synthesized risk estimates of the overall health effects of low and high temperature taking account of the heterogeneity. Methods: A comprehensive literature search was conducted using PUBMED to identify journal articles of low and/or high temperature effects on mortality. The search was limited to the English language and epidemiological studies using time-series analysis and/or case-crossover design. Random-effect models in meta analysis were used to estimate the percent increase in mortality with $1^{\circ}C$ temperature decrease or increase with 95% confidence intervals (CI) in cold or hot days. Results: Twenty three studies were presented in two tables: 1) low temperature effects; 2) high temperature effects on mortality. The combined effects of low and high temperatures on total mortality were 2% (95% CI, 1-4%) per $1^{\circ}C$ decrease and 4% (95% CI, 2-5%) per $1^{\circ}C$ increase of temperature, respectively. Conclusions: This meta analysis found that both low and high temperatures affected mortality, and the magnitude of high temperature appeared to be stronger than that of low temperature.

DESIGN OF A LOW TEMPERATURE DIFFERENCE STIRLING ENGINE (저온도차 모형 스털링 엔진의 최대출력 설계조건)

  • Jung, P.S.;Won, M.Y.;Kim, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.420-423
    • /
    • 2003
  • A low temperature difference model Stirling engine is a small Stirling engine running with several degree of temperature difference without power output. In this study, the design parameters to give maximum power are discussed. As results, the phase angle is about 100 degree, and compression ratio is 1.5% of the ratio of heat source temperatures at maximum power condition.

  • PDF

A design study of a 4.7 T 85 mm low temperature superconductor magnet for a nuclear magnetic resonance spectrometer

  • Bae, Ryunjun;Lee, Jung Tae;Park, Jeonghwan;Choi, Kibum;Hahn, Seungyong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.24-29
    • /
    • 2022
  • One of the recent proposals with nuclear magnetic resonance (NMR) is a multi-bore NMR which consists of array of magnets which could present possibilities to quickly cope with pandemic virus by multiple inspection of virus samples. Low temperature superconductor (LTS) can be a candidate for mass production of the magnet due to its low price in fabrication as well as operation by applying the helium zero boil-off technology. However, training feature of LTS magnet still hinders the low cost operation due to multiple boil-offs during premature quenches. Thus in this paper, LTS magnet with low mechanical stress is designed targeting the "training-free" LTS magnet for mass production of magnet array for multi-bore NMR. A thorough process of an LTS magnet design is conducted, including the analyses as the followings: electromagnetics, mechanical stress, cryogenics, stability, and protection. The magnet specification was set to 4.7 T in a winding bore of 85 mm, corresponding to the MR frequency of 200 MHz. The stress level is tolerable with respect to the wire yield strength and epoxy crack where mechanical disturbance is less than the minimum quench energy.

Analysis of The Operation of a Low Temperature Differential Model Stilting Engine (저온도차 모형 스터링 엔진의 작동 해석)

  • Kim, Jung-Kuk;Shim, Kyung-Yong;Jung, Pyung-Suk
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.199-204
    • /
    • 2000
  • A low temperature differential model stirling engine is manufactured, and its operation characteristics are measured and analyzed by SIMPLE analysis model, in which heat transfer processes are simply considered. The heat transfer coefficients between working fluid and heat sources in the analysis are estimated by comparing the P-V diagrams by experiment and by analysis. This result may be very useful for further design and manufacture of model Stilting engines as well as real engines because it provides a comparatively correct predictions of the operation conditions and power output. It will be also conveniently used as an educational material for mechanical engineering students because it can be a nice example of optimal design process to decide the phase angle and compression ratio of engine design with a simple but realistic simulation.

  • PDF

Low Temperature Bonding Process of Silicon and Glass using Spin-on Glass (Spin-on Glass를 이용한 실리콘과 유리의 저온 접합 공정)

  • Lee Jae-Hak;Yoo Choong-Don
    • Journal of Welding and Joining
    • /
    • v.23 no.6
    • /
    • pp.77-86
    • /
    • 2005
  • Low temperature bonding of the silicon and glass using the Spin-on Glass (SOG) has been conducted experimentally to figure out the effects of the SOG solution composition and process variables on bond strength using the Design of Experiment method. In order to achieve the high quality bond interface without rack, sufficient reaction time of the optimal SOG solution composition is needed along with proper pressure and annealing temperature. The shear strength under the optimal SOG solution composition and process condition was higher than that of conventional anodic bonding and similar to that of wafer direct bonding.

DESIGN STUDY OF AN IHX SUPPORT STRUCTURE FOR A POOL-TYPE SODIUM-COOLED FAST REACTOR

  • Park, Chang-Gyu;Kim, Jong-Bum;Lee, Jae-Han
    • Nuclear Engineering and Technology
    • /
    • v.41 no.10
    • /
    • pp.1323-1332
    • /
    • 2009
  • The IHX (Intermediate Heat eXchanger) for a pool-type SFR (Sodium-cooled Fast Reactor) system transfers heat from the primary high temperature sodium to the intermediate cold temperature sodium. The upper structure of the IHX is a coaxial structure designed to form a flow path for both the secondary high temperature and low temperature sodium. The coaxial structure of the IHX consists of a central downcomer and riser for the incoming and outgoing intermediate sodium, respectively. The IHX of a pool-type SFR is supported at the upper surface of the reactor head with an IHX support structure that connects the IHX riser cylinder to the reactor head. The reactor head is generally maintained at the low temperature regime, but the riser cylinder is exposed in the elevated temperature region. The resultant complicated temperature distribution of the co-axial structure including the IHX support structure may induce a severe thermal stress distribution. In this study, the structural feasibility of the current upper support structure concept is investigated through a preliminary stress analysis and an alternative design concept to accommodate the IHTS (Intermediate Heat Transport System) piping expansion loads and severe thermal stress is proposed. Through the structural analysis it is found that the alternative design concept is effective in reducing the thermal stress and acquiring structural integrity.

The Design and Performance Test of Mold Transformer for Outdoor Pole (50 kVA 주상용 몰드변압기의 설계 및 특성평가)

  • Cho, Han-Goo;Lee, Un-Yong;HwangBo, Kuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.132-137
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. In this paper, the temperature distribution of 50 kVA pole mold transformer for power distribution are investigated by FEM program and the temperature rise test of designed mold transformer carried out and test result is analyzed compare to simulation data. In this result, the designed mold transformer is satisfied to limit value of temperature and the other property is good such as voltage ratio, winding resistance, no-load loss, load loss, impedance voltage and percent regulation.

  • PDF

A Low-Power Design and Implementation of the Portable Device for Measuring Temperature and Humidity Based On Power Consumption Modeling (소비 전력 모델링에 입각한 휴대용 온습도 측정기의 저전력 설계 및 구현)

  • Lee, Chul-Ho;Hong, Youn-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.1027-1035
    • /
    • 2014
  • The most important design factor for portable devices is power consumption. In this paper, in the early design stage of a mobile device which measures temperature and humidity a power consumption model will be proposed and then the overall power consumption will be estimated based on this model. We will verify previously the correctness of such estimated power consumption before implementation of the real device. That is our proposed design methodology based on power consumption model. An improved design method for efficiently reducing the current consumption in the idle mode is also presented. By implementing a real prototype of the mobile device for measuring temperature and humidity, the correctness of our proposed design methodology based on power consumption modeling will be verified.

A Study on the Economical Design of Airport Low-Voltage Feeder Which is considering the Temperature Character (온도특성을 고려한 공항 저압간선의 경제적인 설계기법에 관한 연구)

  • 최홍규;조계술;송영주
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.119-126
    • /
    • 2003
  • The size of low voltage level conductor cables can be installed with a long length just like a aviation field, shall be determined for considering the ampacity of cable and the drop of voltage for the power system. Therefore, The size of the conductor cables may be larger one for considering the tolerable voltage drop comparatively, although the allowable ampacity of the conductor cables may have a margin in comparison with the rated full load current In this case, the conductor cables' allowable ampacity will be very larger than the rated full load current and the generated heat of the conductor will be relatively downed. The conductor cables' alternating current resistance corrected with the maximum allowable temperature of the conductors, has been applied on the general formula for the calculating the voltage drop in determinating the size of low voltage level conductor cables, and the resistance is larger than the resistance corrected with the actual temperature of the conductor cables. This paper was studied for the purpose of the conductor resistance corrected with the actual temperature rise of the conductor and address the economic design formula so that this studies shall minimize the errors which can be occurred in comparison with the general formula and which can be applied in design work for determining the size of low voltage level conductor cables.

Mechanical Load Performance Measurements of a Low Temperature Differential Stirling Engine with Water-Sprayed Heat Transfer according to Supply Water Flow Rates and Temperatures (스프레이 열전달을 이용한 저온도차 스털링 엔진의 고온수 공급 유량 및 온도에 따른 기계 부하성능 실험)

  • Sim, Kyuho;Jeong, Min-Seong;Lee, Yoon-Pyo;Jang, Seon-Jun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.29-36
    • /
    • 2015
  • Recently, Stirling engines are emerging as a key device for power conversion of renewable energy or waste energy. This study develops a LTDSE(Low Temperature Differential Stirling Engine) using a water spray for higher heat transfer and performs load performance tests for various flow rates and temperatures of hot water spray for variable engine loads emulated by a mechanical friction device. Internal temperature and pressure, working frequency and inlet and outlet temperature of the supply water are measured. As a result, the increases in flow rate and temperature of hot water respectively enhance the power output, efficiency and the working frequency, while the increasing engine load leads to decreases in working frequency but increases in the pressure amplitude. Eventually, it is revealed there exists a maximum shaft power of the test engine.