• 제목/요약/키워드: Low-frequency oscillation

검색결과 276건 처리시간 0.022초

저주파 진동 해석을 위한 UPFC의 동적 시뮬레이션 알고리즘에 관한 연구 (A Study on the UPFC Dynamic Simulation Algorithm for Low Frequency Oscillation Studies)

  • 손광명
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권10호
    • /
    • pp.502-508
    • /
    • 2000
  • This paper presents a dynamic simulation algorithm for studying the effect of United Power Flow Controller(UPFC) on the low frequency power system oscillations and transient stability studies. The proposed algorithm is a Newton-type one and uses current injection type UPFC model, which gives a fast convergence characteristics. The algorithm is applied to studying inter-area power oscillation damping enhancement of a sample two-area power system both in time domain and frequency domain. The case study results show that the proposed algorithm is very efficient and UPFC is very effective and robust against operating point change.

  • PDF

TCSC의 $H_{\infty}$ 제어에 의한 대규모 전력계통의 지역간 저주파진동 억제 PartI : 설치지점 선정 (Damping Inter-area Low Frequency Oscillations in Large Power Systems with $H_{\infty}$ Control of TCSC PARTI : TCSC Siting)

  • 김용구;심관식;송성근;김영환;남해곤
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권5호
    • /
    • pp.226-232
    • /
    • 2000
  • This paper presents application results of the augmented matrix eigen-sensitivity theories to TCSC siting problem for damping the inter-area low frequency oscillation in the large KEPCO system. First and second-order eigen-sensitivities of the inter-area low frequency oscillation in the large KEPCO system. First and second-order eigen-sensitivities of the inter-area mode are computed fro changes in susceptance of the transmission lines. The lines having high sensitivity are chosen as the initial candidates for installing TCSC. Then for each of the chosen candidates, Bodeplot of the transfer function with line susceptance as the input and the bus voltage at one side of the line as the output is computed. Using the Bode plots, the lines having any zeros near the inter-area mode are screened out since design of TCSC controller is very difficult in such a case. The $H_{\infty}$ TCSC controller installed at any finally chosen candidate is found to be effective in damping the inter-area oscillation, and the proposed TCSC siting algorithm is proved to be valid. Design of $H_{\infty}$ controller is described in Part IIof this paper.

  • PDF

발전용 가스터빈에서 발생하는 연소진동 특성 및 이상연소진동의 저감 (Characterization of Combustion Oscillation and Reduction of Abnormal Oscillation in a Power Generation Gas Turbine)

  • 서석빈;안달홍;정재화
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1682-1685
    • /
    • 2004
  • Gas Turbine combustors for power plant can be reduced NOx emissions using lean premixed combustion technology. But the combustors are likely to occur combustion oscillations which damage operation reliability and mechanical life of the gas turbines. In this paper, characterizations of oscillation in a gas turbine combustor for power plant are presented. Combustion dynamics occur $1{\sim}1.5$ psi in amplitude with low frequency less than 140Hz during normal operation. An abnormal high level dynamics, 2.0 psi amplitude occur at 125 Hz frequency. Abnormal combustion oscillation is reduced by modulation of fuel supply valve control schedule.

  • PDF

관형 연소기의 열 음향학적 특성에 관한 실험적 연구 (Characteristics of thermoacoustic oscillation in ducted flame burner)

  • 조상연;이수갑
    • 소음진동
    • /
    • 제7권6호
    • /
    • pp.985-991
    • /
    • 1997
  • Combustion instability is a common phenomenon in a ducted flame burner and is known as accompanying low frequency oscillation. This is due to the interaction between unsteady heat release rate and sound pressure field, that is, thermoacoustic feedback. In Rayleigh criterion, combustion instability is triggered when the heat addition is in phase with acoustic oscillation. A Rijke type burner with a pre-mixed flame is built for investigating the effect of Reynolds number and equivalence ratio on thermoacoustic oscillation. The results suggest that the frequency of max, oscillation is dependent on Reynolds number and equivalence ratio whereas its magnitude is not a strong function of these two parameters.

  • PDF

Measurement Accuracy of Oscillation-Based Test of Analog-to-Digital Converters

  • Mrak, Peter;Biasizzo, Anton;Novak, Franc
    • ETRI Journal
    • /
    • 제32권1호
    • /
    • pp.154-156
    • /
    • 2010
  • Oscillation-based testing of analog-to-digital converters represents a viable option for low-cost built-in self-testing in mixed-signal design. While numerous papers have addressed implementation issues, little attention has been paid to the measurement accuracy. In this letter, we highlight an inherent measurement uncertainty which has to be considered when deriving the parameters from the oscillation frequency.

High Frequency Variation of Low Water Temperature due to Arctic Oscillation Around the Western and Southern Coast of Korea During Winter 2017/2018

  • Han, In-Seong;Lee, Joon-Soo;Kim, Ju-Yeon;Hong, Ji-Yeon
    • 해양환경안전학회지
    • /
    • 제25권3호
    • /
    • pp.328-333
    • /
    • 2019
  • During the winter of 2017/2018, significantly low water temperatures were detected around the western and southern coasts of Korea (WSCK). In this period, sea surface temperature (SST) in the Korea Waters was about $2^{\circ}C$ lower than mean temperature. Using the real-time observation system, we analyzed the temporal variation of SST during this period around the western and southern coasts. Low water temperature usually manifested over a period of about 10 ~ 20 days. The daily Arctic oscillation index was also similarly detectable with the variation of SST. From the cross-correlation function, we compared two periodic variations, which were SST around the WSCK and the Arctic oscillation index. The cross correlation coefficients between both variations were approximately 0.3 ~ 0.4. The time lag of the two time series was about 6 to 7 days. Therefore, significantly low water temperatures during winter in the Korean coastal areas usually became detectable 6 to 7 days after the negative peak of Arctic oscillation.

시간영역에서 파라미터 추정과 전력계통의 저주파진동 해석 (A Parameter Estimation of Time Signal and Analysis of Low Frequency Oscillation in Power Systems)

  • 심관식;남해곤;김용구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권3호
    • /
    • pp.122-132
    • /
    • 2005
  • This paper presents a novel approach based on Prony method to analysis of small signal stability in power system. Prony method is a valuable tool in identifying transfer function and estimating the modal parameter of power system oscillation from measured or computed discrete time signal. This paper define the relative residue of time signal and propose the condition to select low frequency oscillation in each generator. This paper describes the application results of proposed algorithm with respect to KEPCO systems. Simulation results show that the proposed algorithm can be used as another tools of power systems analysis.

위상동기신호를 이용한 한전계통의 저주파진동 검출과 고유치해석 (Eigenvalue Analysis and Detection of Low Frequency Oscillation using PMU Data in KEPCO System)

  • 심관식;김상태;김태균;안선주;최준호
    • 전기학회논문지
    • /
    • 제66권2호
    • /
    • pp.261-284
    • /
    • 2017
  • This paper describes the results of a low-frequency oscillation analysis using data measured in PMU installed in the KEPCO system, and the comparison with eigenvalues computed from the linear model. The dominant oscillation modes are estimated by applying various algorithms. The algorithms are: the extended Prony method; multiple time interval parameter estimation method; subspace system identification method; and spectral analysis. From the measurement data, modes of frequency 0.68[Hz] and 0.92[Hz] were estimated, and modes of frequency 0.63[Hz] and 0.80[Hz] were computed from the eigenvalue calculation. There was a difference between the mode estimated from measurement data and that from the linear model. This is possibly because of an error in the dynamic data of the KEPCO system used in eigenvalue calculation. Because wide area modes exist in the KEPCO system, these modes should be monitored continuously for the reliable operation of the system. In order to prevent total blackouts caused by wide area oscillation, moreover, contingency analysis should be performed in relation to this mode and appropriate measures should be established.

저주파 진동 감쇠를 위한 UPFG의 제어 (Control of UPFG to Reduce Low Frequency Oscillation)

  • 김태현;서장철;문승일;박종근;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.848-850
    • /
    • 1997
  • A control method of UPFC (Unified Power Flow Controller) to reduce low frequency oscillation is proposed. UPFC is modelled by voltage source, which magnitude and phase angle can be controlled. Because there needs some time to change to desired value, d-axis voltage and Q-axis voltage is modeled by 1st order delay. LQG(Linear Quadratic Gaussian) is used. It is shown that low frequency can be damped by control of UPFC effectively.

  • PDF

흡수격자를 갖는 DFB 레이저의 제작 및 특성 (Fabrication and Characteristics of DFB Laser with Absorption Grating)

  • 이형종
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1990년도 제5회 파동 및 레이저 학술발표회 5th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.73-78
    • /
    • 1990
  • 1.3${\mu}{\textrm}{m}$ DFB with absorption grating of 1.55${\mu}{\textrm}{m}$ InGaAsP layer was fabricated. This new type of DFB laser shows self-plusation for DC operation. At low level of injection the relation between the pulsation frequency and the injection current shows similar behavior with the relaxation oscillation of ordinary laser and at high level of injection the pulsation frequency decreases compared to the relaxation oscillation. Period doubling, period 3 and 4 were observed for AC modulation. In case of period doubling the waveform shows only one pulse within a period without any accompanying subsidiary pulses and the oscillation frequency was quite stable. The pulse widths as short as 58.5 ps was achieved with AC modulation. We propose the time division multiplexing application of this kind of DFB laser.

  • PDF