• Title/Summary/Keyword: Low-energy operation plan

Search Result 21, Processing Time 0.03 seconds

Construction Equipment Fleet Optimization for Saving Fuel Consumption (에너지 절감을 위한 건설장비 조합 최적화 방법 연구)

  • Yi, Chang-Yong;Lee, Hong-Chul;Lee, Dong-Eun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.198-199
    • /
    • 2015
  • Construction equipment is a major energy consumption source in construction projects. If 10% reduction of the diesel fuel usage is achieved in the construction industry, it may reduce 5% of the total energy usage. Energy saving operation is a major issue in equipment-intensive operations (e.g., earthmoving or paving operations). Identifying optimal equipment fleet is important measure to achieve low-energy consumption in those operations. This study presents a system which finds an optimal equipment fleet by computing the low-energy performance of earthmoving operations. It establishes construction operation model and compares numerous combinations using alternative equipment allocation plans. It implements sensitivity analysis that facilitates searching the lowest energy consumption equipment fleet by enumerating all cases.

  • PDF

A study on application plan of driver assistance system for railway energy efficiency (철도에너지 효율화를 위한 운전자 지원시스템 적용방안 연구)

  • Kim, Young-Kyu;Park, Se-Young;Ko, Young-Ho;Nam, Hui-Bok;Han, Moon-Sub
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.171-176
    • /
    • 2010
  • Railway has recently played an important role in preventing global warming caused by green house gases and furthering a low carbon green growth, The various railway research centers have conducted facilitated studies on saving energy. In particular, urban railway has emerged as the best means of public transportation in terms of punctuality, safety and environmentally friendliness. There are various ways to save energy in terms of operation of urban railway system, and they can be generally divided into hardware aspects that pertain to structure of vehicles and development of control system and software aspects that pertain to effective operation of trains based on operation patterns and diagram control. In this paper, we investigated drive assistance system for railway energy efficiency. The railway operation patterns and train diagram management programs were researched.

  • PDF

A Study on the Lighting Plan Characteristics of Office Buildings (오피스 건물의 실내 조명 유형 및 계획특성에 관한 연구)

  • Yi, Yon-Soo;Ha, Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.1
    • /
    • pp.47-54
    • /
    • 2013
  • For the office work environmental design, the importance of the design management is increased to improve operation efficiency as well as the aesthetic environmental implementation of the function today. Lighting is a required element ineffective operation environment. It has become more important for the aesthetic, economic, and practical reasons, to consider the luminous environment and the lighting of visual tasks separately. When the brightness is insufficient, productivity deteriorates, and the layout of the lighting located by mistake causes the fatigue of eyes. Productivity rises to office in a large number of studies so as satisfaction is low in general in the dark office, and to be bright. Therefore the purpose of this research is to suggest the right direction of lighting design of office building area. 11newly renovated office buildings are selected for this luminous environment research. We could conclusions as following through this research. First, it was planned brighter than the recommended lighting level in the most space. It shows that the accurate lighting design criteria is needed in order to achieve proper lighting environment. Second, the application of the LED lighting fixtures is continuously increased in the recent office lighting environment. It is explained that it is applied for reasons of the electrical energy reduction and the maintenance efficiency with the long life time. Third, the consideration of the lighting plan for the difference of working types is not enough. with various communication configuration through an independent plan, and the effective lighting plan that appropriateness preparation design and energy saving area vailable must be applied. Fourth, the lighting environment of the lobby needs a specialized lighting plan as are presentative space of the building.

A Study on Peak Power Reduction using Regenerative Energy in Railway Systems through DC Subsystem Interconnection

  • Jung, Seungmin;Lee, Hansang;Kim, Kisuk;Jung, Hosung;Kim, Hyungchul;Jang, Gilsoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1070-1077
    • /
    • 2013
  • Owing to the consistent increase in energy efficiency issues, studies for improving regenerative energy utilization have been receiving attention in the Urban DC railway systems, where currently, the utilization of regenerative energy is low due to the lack of a specific plan for using this energy. The regenerative energy in railway systems has a low efficiency problem which results in the increase of the catenary voltage and a possibility to create problems to the electrical devices connected to the system. This paper deals with the power integration of large urban railway subsystems to improve regenerative energy utilization where the railway subsystems are integrated with other railway subsystems to improve the energy efficiency. Through the case studies, to find the realistic effect of integrated operation, the Seoul Metro subsystems, namely Line 5 and Line 7, has been applied. Also, evaluation for the electricity cost saving has been performed by using KEPCO electricity cost table.

A Study of Improving Regenerative Energy Utilization in Urban DC Railway Systems Through Sharing Substations (철도 변전소 공유를 통한 직류 도시철도 시스템 회생에너지 이용률 향상 방안 연구)

  • Jung, Seung-Min;Lee, Han-Sang;Byun, Gil-Sung;Kwon, Sae-Hyuk;Jang, Gil-Soo;Jung, Ho-Sung;Kim, Hyung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2392-2396
    • /
    • 2011
  • This paper deals with the power integration of large urban railway systems to improve regenerative energy utilization. Current regenerative energy utilization is low because there is no special plan for using this energy. If the railway system is integrated with other railway systems, the efficiency is expected to be improved. Through the case studies, to find the realistic effect of integrated operation, real system for the Seoul Metro lines, especially line 5 and 7, had been applied.

Ordering of Alloy 690 Steam Generator Tubings in a Nuclear Power Plant (원자력발전소 증기발생기 Alloy 690 전열관 재료의 규칙화 반응)

  • Seong Sik Hwang;Min Jae Choi;Sung Woo Kim
    • Corrosion Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.214-219
    • /
    • 2023
  • Considering the case in the United States where most nuclear power plants with an initial design life of 40 years continue to operate until 60 or 80 years after undergoing material soundness evaluation, it is time to plan a more robust long-term operation strategy for nuclear power plants in Korea. There are some reports that SRO/LRO might be formed when Alloy 690 is heat treated for 10,000 hours to 100,000 hours at 360 to 450 ℃. The possibility of LRO formation in Alloy 690 steam generator tubings of Kori nuclear power plant unit 1 (Kori-1) was investigated using existing research papers. The mechanism in which SRO/LRO occurred was also surveyed. Alloy 690 was found to be more likely to cause ordering than Alloy 600 in terms of alloy composition. The ordering could be evaluated through changes in material properties. However, it is difficult to evaluate it from a microstructural point of view. The likelihood of LRO in Alloy 690 of the Kori-1 plant operated at 320 ℃ for 19 years seemed to be low in terms of time and exposure temperature.

Radiological Safety Assessment of Transporting Radioactive Wastes to the Gyeongju Disposal Facility in Korea

  • Jeong, Jongtae;Baik, Min Hoon;Kang, Mun Ja;Ahn, Hong-Joo;Hwang, Doo-Seong;Hong, Dae Seok;Jeong, Yong-Hwan;Kim, Kyungsu
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1368-1375
    • /
    • 2016
  • A radiological safety assessment study was performed for the transportation of low level radioactive wastes which are temporarily stored in Korea Atomic Energy Research Institute (KAERI), Daejeon, Korea. We considered two kinds of wastes: (1) operation wastes generated from the routine operation of facilities; and (2) decommissioning wastes generated from the decommissioning of a research reactor in KAERI. The important part of the radiological safety assessment is related to the exposure dose assessment for the incidentfree (normal) transportation of wastes, i.e., the radiation exposure of transport personnel, radiation workers for loading and unloading of radioactive waste drums, and the general public. The effective doses were estimated based on the detailed information on the transportation plan and on the radiological characteristics of waste packages. We also estimated radiological risks and the effective doses for the general public resulting from accidents such as an impact and a fire caused by the impact during the transportation. According to the results, the effective doses for transport personnel, radiation workers, and the general public are far below the regulatory limits. Therefore, we can secure safety from the viewpoint of radiological safety for all situations during the transportation of radioactive wastes which have been stored temporarily in KAERI.

Solar radiation forecasting using boosting decision tree and recurrent neural networks

  • Hyojeoung, Kim;Sujin, Park;Sahm, Kim
    • Communications for Statistical Applications and Methods
    • /
    • v.29 no.6
    • /
    • pp.709-719
    • /
    • 2022
  • Recently, as the importance of environmental protection has emerged, interest in new and renewable energy is also increasing worldwide. In particular, the solar energy sector accounts for the highest production rate among new and renewable energy in Korea due to its infinite resources, easy installation and maintenance, and eco-friendly characteristics such as low noise emission levels and less pollutants during power generation. However, although climate prediction is essential since solar power is affected by weather and climate change, solar radiation, which is closely related to solar power, is not currently forecasted by the Korea Meteorological Administration. Solar radiation prediction can be the basis for establishing a reasonable new and renewable energy operation plan, and it is very important because it can be used not only in solar power but also in other fields such as power consumption prediction. Therefore, this study was conducted for the purpose of improving the accuracy of solar radiation. Solar radiation was predicted by a total of three weather variables, temperature, humidity, and cloudiness, and solar radiation outside the atmosphere, and the results were compared using various models. The CatBoost model was best obtained by fitting and comparing the Boosting series (XGB, CatBoost) and RNN series (Simple RNN, LSTM, GRU) models. In addition, the results were further improved through Time series cross-validation.

Security Improvement Plan for Nationwide Key Energy Facilities (국가주요에너지시설 보안향상방안)

  • Chung, Taehwang
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.2
    • /
    • pp.263-267
    • /
    • 2015
  • This study shows the result of the security assessment of the nationwide key energy facilities and suggests the ways of improving the security level. According to the study, most of the energy facilities are adequately equipped with physical security factors such as security personnel, security systems, fences, and guard posts, but lack of awareness is pervasive among those concerned, so the security operation is inefficient. In other words, inefficient deployment of security personnel, lack of the fundamental knowledge of the security systems, excessive dependence on surveillance cameras' functions such as Pan/Tilt/Zoom, misplaced cameras, low efficiency of monitoring, and irrelevant security plans. To solve these problems, above all, the authority concerned need to develop professional training programs to secure certified security mangers, and need to standardize security process to ensure consistency and to harness the standardization as a source of self assessment to improve security level.

Efficient Operation and Management Scheme of Micro Data Centers for Realization of Edge Computing (에지 컴퓨팅의 실현을 위한 마이크로 데이터센터의 효율적인 운영 및 관리 기법)

  • Choi, JungYul
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.11
    • /
    • pp.30-39
    • /
    • 2020
  • As 5G mobile communication services are provided, efforts are being made to provide various services to users with ultra-low latency. This raises interest in edge computing, which can provide high performance computing services near users instead of cloud computing at the network core. This paper presents an efficient operation and management scheme of a micro data center, which is an essential equipment for realizing edge computing. First, we present the functional structure and deployment plan of edge computing. Next, we present the requirements for the micro data centers for edge computing and the operation and management scheme accordingly. Finally, in order to efficiently manage resources in the micro data centers, we present resource management items to be collected and monitored, and propose a performance indicator to measure the energy efficiency.