• 제목/요약/키워드: Low-dye

검색결과 515건 처리시간 0.024초

유연성 평발에 적용한 로우다이 테이핑에 의한 균형 수행력의 변화 (The Changes of Balance Performance by Low-dye Taping Application on Flexible Flatfoot)

  • 엄주리;문동철;김종순
    • 대한물리의학회지
    • /
    • 제9권4호
    • /
    • pp.355-361
    • /
    • 2014
  • PURPOSE: The purpose of this study was to determine the immediate effect of low-dye taping on balance performance in subjects with flexible flatfoot. METHODS: Fifteen asymptomatic volunteers who had flexible flatfoot (age, $21.7{\pm}1.81$years; height, $164.80{\pm}7.57cm$; weight, $56.47{\pm}10.48kg$) were participated for this study. Navicular drop test was used to evaluate pronation of foot in three different conditions; non-weight bearing position without low-dye taping, weight bearing position without low-dye taping, weight bearing position with low-dye taping. And balance performance (anterio/ posterior, medial/lateral, and overall) was evaluated using the Biodex Balance System in three different conditions; one-leg standing without low-dye taping, one-leg standing with low-dye taping, and one-leg standing with low-dye taping in one week later. Repeated-measures analysis of variance (ANOVA) was used to assess navicular height and balance performance across the three testing conditions. RESULTS: Significant and clinically meaningful improvement in navicular height was found after application of the low-dye taping. However, there was no statistically significant change in balance performance. CONCLUSION: The results of this study provide evidence to suggest that low-dye taping does not affect balance performance.

편평발에서 Low-dye 테이핑이 한발 서기 동안 근활성도 변화에 미치는 영향 (The Effect of Low-dye Taping on Muscle Activity during Single-leg Standing in People with Flatfoot)

  • 박민철
    • 대한물리의학회지
    • /
    • 제8권4호
    • /
    • pp.533-538
    • /
    • 2013
  • PURPOSE: This study was performed to investigate the effect of Low-dye Taping on muscle activity during single-leg standing in subjects with flexible flatfoot. METHODS: Thirteen able-body volunteers who had flexible flatfoot were recruited for this study. Subjects were measured navicular drop test to evaluate pronation of foot and muscle activity during single-leg standing before and after taping. The muscle activity was recorded using surface EMG from the tibialis anterior and the peroneus longus during single-leg standing on stable and unstable surface. RESULTS: The results show that the navicular drop height and the tibialis anterior muscle activity were significantly decreased after Low-dye taping. CONCLUSION: The results suggest that Low-dye taping could be useful in managing overuse of the tibialis anterior by reducing their level of activation during single-leg standing.

A Study on Optimal Dye-coating Conditions to Reduce Dye-adsorption Time with Improved DSSC Efficiency

  • 서영호;최은창;홍병유
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.481.1-481.1
    • /
    • 2014
  • Dye-sensitized solar cell (DSSC) has been extensively investigated as the next generation energy source. Despite attractive features of simple fabrication process and its economical efficiency, there are some problems such as low efficiency and low long-term stability. Many groups have attempted the proposed way to improve the cell efficiency and long-term stability such as low recombination rate between $TiO_2$ surface and electrolyte, the development of new dye molecules capable of light adsorption as broadly as possible, the fabrication of a solid-state DSSC by replacing the liquid electrolyte, and protective coating on glass. In this work, we confirmed new dye-coating conditions to maximize the dye adsorption between the dye and $TiO_2$ nanoparticle surface. The experiment results coating conditions with the coating temperature of $70^{\circ}C$, the dye concentration of 10 mM and the coating time of 3 min. Conditions have two times, three times cycle the experiment in progress efficiency rises.

  • PDF

Low-dye 테이핑과 발 내재근육 강화 운동을 적용한 편평발을 가진 20대 성인의 하지 근육활성도 비교 연구 (A comparative study of lower extremity muscle activity in adults in their 20s with flat foot that applied low-dye taping and foot intrinsic muscle strengthening exercise)

  • 유경태
    • 산업융합연구
    • /
    • 제19권5호
    • /
    • pp.103-110
    • /
    • 2021
  • 본 연구의 목적은 편평발을 가진 자를 대상으로 Low-dye 테이핑과 발 내재근육 강화 운동이 한 발 서기 동안 앞정강근, 장딴지근, 긴종아리근의 근육활성도에 미치는 영향을 알아보고자 실시하였다. 대상자는 편평발을 가진 20대 성인 16명이며, Low-dye 테이핑(LTG; n=8) 및 발 내재근육 강화 운동(FSG; n=8) 그룹으로 나누었다. 각 그룹은 해당되는 중재를 주 2회 6주간 실시하였다. 앞정강근, 긴종아리근 및 안쪽 장딴지근의 근육 활성도를 측정하였다. 중재 전·후 근육활성도의 변화를 비교하기 위하여 반복된 이원 배치 분산분석을 실시하였다. 근육활성도 측정 결과, LTG에서는 모든 근육에서 실험 전·후 사이에 유의하게 감소하였다(p<.05). FSG에서는 실험 전·후 사이에 앞정강근에서만 유의하게 감소하였다(p<.05). 따라서, Low-dye 테이핑과 발 내재근 육강화 운동은 편평발 환자에게 효율적인 하지 근육 활동에 도움이 될 것이다.

Low-Dye 테이핑 적용이 아치회복운동을 시행한 편평족의 장딴지근력에 미치는 효과 (Effect of Gastrocnemius Strength to be Applicated Low-Dye Taping in Flatfoot with Arch-Recovery Exercise)

  • 박재규;김광록;김건우;김민지;노수빈;성누가;김진아
    • 한국임상보건과학회지
    • /
    • 제4권3호
    • /
    • pp.634-643
    • /
    • 2016
  • Purpose. The purpose of this study was to progress the effect of gastrocnemius strength when groups are applicated on low-dye taping group and without taping group of flatfoot with arch-recovery exercise. Methods. Subjects were measured navicular drop test to confirm of 16 university student in J city, low-dye taping group and without taping group were applicated both with arch-recovery exercise, three times per a week for four weeks. The power track were measured four weeks, total 3 times. Comparative analysis of the control group and experimental group were investigated of gastrocnemius strength. Results. The results, we found that after of arch-recovery exercise were significantly increased than before of arch-recovery exercise in each foot. And application of low-dye taping(experimental group) in flatfoot with arch-recovery exercise were significantly increased than control group. Conclusions. In conclusion, the arch-recovery exercise application were effective to low-dye taping significantly increase the gastrocnemius strength of flatfoot.

테이핑 방법에 따른 유연성 평발의 족저압 및 보행 특성 변화 (Changes in Plantar Pressure and Gait Characteristics in Adults with Asymptomatic Flexible Pes Planus by Different Taping)

  • 김종순
    • PNF and Movement
    • /
    • 제20권2호
    • /
    • pp.167-177
    • /
    • 2022
  • Purpose: Pes planus is a common foot deformity that involves the loss of the medial longitudinal arch. The medial longitudinal arch deformity is usually asymptomatic; however, it can lead to an increased risk of pain and injury. Low-Dye taping is designed to treat plantar heel pain and pes planus. However, low-Dye taping is relatively complex, and a considerable amount of time is required to apply the tape correctly. The purpose of this study was to compare the acute effect of two different types of taping (low-Dye taping and modified Mulligan taping) on arch reformation, plantar pressure, and gait characteristics in participants with asymptomatic flexible pes planus. Methods: Twenty subjects (9 males and 11 females; mean age = 21.95 years) with asymptomatic flexible pes planus voluntarily participated in this study. Arch reformation was evaluated using navicular height measurements. Changes in plantar pressure distribution were measured using BioRecue equipment. Gait parameters were measured using spatiotemporal data collected during consecutive gait cycles using a G-WALK device. One-way analysis of variance was used to compare the three different conditions (i.e., bare foot, low-Dye taping, and modified Mulligan taping) for each variable. Results: Navicular height was significantly increased in subjects who underwent the two types of taping compared to those who experienced the bare foot condition. The plantar pressure was significantly shifted to the posterolateral area after modified Mulligan taping compared with the bare foot condition. There were no significant differences in the gait parameters. Conclusion: The findings of this study indicate that modified Mulligan taping has a similar effect to low-Dye taping, and modified Mulligan taping is a simpler method than low-Dye taping.

Effect of Polymer Shielding on Elution of G3PDH Bound to Dye-ligand Adsorbent

  • Ling Tau Chuan;Lyddiatt Andrew
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제11권1호
    • /
    • pp.84-87
    • /
    • 2006
  • Batch binding experiments were performed to assess the recovery performance of glyceraldehyde 3-phosphate dehydrogenase (G3PDH) bound to the unshielded and polymer (polyvinyl pyrrolidone. PVP)-shielded dye-ligand (Cibacron Blue 3GA) adsorbent. The adoption of a polymer-shielded, dye-ligand technique facilitated the elution efficiency of bound G3PDH. It was demonstrated that the recovery of G3PDH using polymer-shielded dye-ligand adsorption yielded higher elution efficiency, at 60.5% and a specific activity of 42.3 IU/mg, after a low ionic strength elution (0.15 M NaCl). The unshielded dye-ligand yielded lower elution efficiency. at 6.5% and a specific activity of 10.2 IU/mg.

Biomechanical Effectiveness of the Low-Dye Taping on Peak Plantar Pressure During Treadmill Walking Exercise in Subjects With Flexible Flatfoot

  • Lim, One-Bin;Kim, Jeong-Ah;Kwon, Oh-Yun;Yi, Chung-Hwi
    • 한국전문물리치료학회지
    • /
    • 제22권2호
    • /
    • pp.41-51
    • /
    • 2015
  • The purposes of this study were 1) to determine the effects of low-dye taping on peak plantar pressure following treadmill walking exercise, 2) to determine whether the biomechanical effectiveness of low-dye taping in peak plantar pressure was still maintained following removal of the tape during treadmill walking, and 3) to determine the trend towards a medial-to-lateral shift in peak plantar pressure in the midfoot region before and after application of low-dye taping. Twenty subjects with flexible flatfoot were recruited using a navicular drop test. The peak plantar pressure data were recorded during five treadmill walking sessions: (1) un-taped, (2) baseline-taped, (3) after a 10-minute treadmill walking exercise, (4) after a 20-minute treadmill walking exercise, and (5) after removal of the taping. The foot was divided into six parts during the data analysis. One-way repeated measures analysis of variance was performed to investigate peak plantar pressure variations in the six foot parts in the five sessions. This study resulted in significantly increased medial forefoot peak plantar pressure compared to the un-taped condition (p=.017, post 10-minute treadmill walking exercise) and (p=.021, post 20-minute treadmill walking exercise). The peak plantar pressure in the lateral forefoot showed that there was a significant decrease after sessions of baseline-taped (p=.006) and 10-minute of treadmill walking exercise (p=.46) compared to the un-taped condition. The tape removal values were similar to the un-taped values in the five sessions. Thus, the findings of the current study may be helpful when researchers and clinicians estimate single taping effects or consider how frequently taping should be replaced for therapeutic purposes. Further studies are required to investigate the evidence in support of biomechanical effectiveness of low-dye taping in the midfoot region.

유연성 편평발 청소년에게 적용한 로우다이 테이핑 기법이 동적 균형과 제자리 멀리뛰기에 미치는 영향 (Effect of low-dye taping technique applied to flexible flatfoot adolescents on dynamic balance and long jump in place)

  • 김은자;김진주
    • 문화기술의 융합
    • /
    • 제8권1호
    • /
    • pp.321-329
    • /
    • 2022
  • 유연성 편평발 청소년에게 적용한 로우다이 테이핑 기법이 동적 균형과 제자리 멀리뛰기에 미치는 영향을 알아보았다. 연구의 대상자는 유연성 편평발 청소년 35명으로 탄력 테이프 17명과 비탄력 테이프 17명으로 로우다이 테이핑 기법을 적용하였다. 본 연구의 자료분석은 t-test 활용하여 그룹 중재 적용 전과 적용 후, 그리고 각각의 그룹간을 비교하였다. 연구 결과 동적 균형과 제자리 멀리뛰기에서 중재 적용 전과 적용 후에 유의한 결과가 나타났으며(p<.05), 각각의 그룹 간 비교에서 유의한 차이가 나타나지 않았다(p>.05). 결론적으로 유연성 편평발의 청소년에게 적용된 로우다이 테이핑 기법은 동적 균형과 제자리 멀리뛰기에 효과가 있으며, 로우다이 테이핑은 안쪽 세로활 상승의 즉각적 효과를 보기 위한 중재 방법으로 적절하다.

Cobalt ferrite nanotubes and porous nanorods for dye removal

  • Girgis, E.;Adel, D.;Tharwat, C.;Attallah, O.;Rao, K.V.
    • Advances in nano research
    • /
    • 제3권2호
    • /
    • pp.111-121
    • /
    • 2015
  • $CoFe_2O_4$ nanotubes and porous nanorods were prepared via a simple one-pot template-free hydrothermal method and were used as an adsorbent for the removal of dye contaminants from water. The properties of the synthesized nanotubes and porous nanorods were characterized by electron diffraction, transmission electron microscopy and x-ray powder diffraction. The Adsorption characteristics of the $CoFe_2O_4$ were examined using polar red dye and the factors affecting adsorption, such as, initial dye concentration, pH and contact time were evaluated. The overall trend followed an increase of the sorption capacity reaching a maximum of 95% dye removal at low pHs of 2-4. An enhancement in the removal efficiency was also noticed upon increasing the contact time between dye molecules and $CoFe_2O_4$ nanoparticles. The final results indicated that the $CoFe_2O_4$ nanotubes and porous nanorods can be considered as an efficient low cost and recyclable adsorbent for dye removal with efficiency 94% for Cobalt ferrite nanotubes and for Cobalt ferrite porous nanorods equals 95%.