• Title/Summary/Keyword: Low-Dose Radiation

Search Result 937, Processing Time 0.034 seconds

Effects of low dose gamma radiation on the germination and yield components of chinese cabbage (저선량 ${\gamma}$선 조사가 배추종자의 발아와 수량에 미치는 효과)

  • Kim, Jae-Sung;Kim, Jin-Kyu;Lee, Young-Keun;Back, Myung-Wha;Gim, Jeong-Kyu
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.3
    • /
    • pp.274-278
    • /
    • 1998
  • To observe the stimulating effects of low-dose ${\gamma}-radiation$ on the Chinese cabbage, $1{\sim}5$ years old seeds were cultivated in the green house and the experimental field after irradiation of $0.5Gy{\sim}30.0Gy$ and the growth characters of them were investigated. The germination rates and the seedling heights of old seeds increased positively in the green house, but different from each other depending on their period of storage. Those of 3-, 4-, and 5-year old seeds increased remarkably at the 4.0Gy-, 1.0Gy-, and 0.5Gy-irradiation group respectively. However, in the case of 1-year and 2-year old seeds, there were not significant effects of irradiation except the increase of seedling height. There were significant increasing effects of radiation on the plant height, fresh weight, and diameter of all seeds grown in the experimental field of 4.0Gy- and 8.0Gy-irradiation group, including the corresponding effects of 1-year and 2-year old seeds in 20.0Gy- and 30.0Gy-irradiation group.

  • PDF

Intentions to Undergo Lung Cancer Screening among Korean Men

  • Cam, Nhung Bui;Lee, Yoon Young;Yoon, HyoJoong;Suh, Mina;Park, Boyoung;Jun, Jae Kwan;Kim, Yeol;Choi, Kui Son
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.15
    • /
    • pp.6293-6298
    • /
    • 2015
  • Opportunistic screening for lung cancer is commonly conducted in Korea in accordance with physician recommendations and screenee's preferences. However, studies have yet to thoroughly examine the public's understanding of the risks posed by lung cancer screening. This study was conducted to assess changes in intentions to undergo lung cancer screening in response to being informed about exposure to radiation during low-dose computed tomography (LDCT) tests and to identify factors with the greatest influence thereon among Korean men. We conducted sub-group interviews among men chosen from the 2013 Korea National Cancer Screening Survey (KNCSS), a nationwide, population-based, cross-sectional survey of men aged 40 to 74 years and women aged 30 to 74 years. From 4100 participants in the KNCSS, 414 men who underwent any cancer screening test within the last 2 years were randomly selected for inclusion in this study. Via face-to-face interviews, their intentions to undergo lung cancer screening were assessed before and after being informed about exposure to radiation during LDCT testing. Of the 414 participants, 50% were current smokers. After receiving information on the benefits of the test, 95.1% stated an intention to undergo screening; this decreased to 81.6% after they received information on the harms of the test. The average decrease in intention rate was 35.3%. Smoking status, household income, and education level were not associated with lowered intentions to undergo lung cancer screening. Participants who were older than 60 years old (OR=0.56; 95% CI= 0.33-0.96) and those with less concern for radiation exposure (OR=0.56; 95% CI=0.36-0.89) were less likely to lower their screening intentions. The results of this study suggest that there is a need to educate both non-smokers and former smokers on the harms of lung cancer screening.

Radiological Safety Assessment for KAERI Incineration Plant on the Basis of Trial Burn Results (시험소각결과에 기준한 한국원자력연구소 소각시설의 방사학적 안전성 평가)

  • Yang, Hee-Chul;Kim, Bong-Hwan;Kim, Chang-Hee;Park, Won-Man;Jeong, Myung-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.2
    • /
    • pp.109-114
    • /
    • 1998
  • Radiological safety for the conventional operation of Demonstration-Scale Incineration Plant (DSIP) was assessed on the basis of the results of trial burns using the simulated and real radioactive wastes. Radiation dose assessments for routine releases on an annual basis as well a several severe accidental releases on a short-term basis (2h) revealed that there would be no significant environmental impact when low-level waste Is incinerated in DSIP. For semivolatile radioactive cesium species, expected emission concentrations slightly exceeded 10% of maximum permissible concentration. Removal characteristics of the bag filter for condensed-phase cesium species was investigated by the trial burns of simulated waste with inactive cesium tracer. In the off-gas before passing through bag filter, distributions of condensed cesium species in the transition size ranging between the diffusional and inertial region are less than 5%. The overall collection efficiency of the bag filter for cesium species was higher than 99.9%, showing enough decontamination capability as a primary filter for the low-temperature dry off-gas system in radwaste incineration plant.

  • PDF

Patient Specific Quality Assurance of IMRT: Quantitative Approach Using Film Dosimetry and Optimization (강도변조방사선치료의 환자별 정도관리: 필름 선량계 및 최적화법을 이용한 정량적 접근)

  • Shin Kyung Hwan;Park Sung-Yong;Park Dong Hyun;Shin Dongho;Park Dahl;Kim Tae Hyun;Pyo Hongryull;Kim Joo-Young;Kim Dae Yong;Cho Kwan Ho;Huh Sun Nyung;Kim Il Han;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.176-185
    • /
    • 2005
  • Purpose: Film dosimetry as a part of patient specific intensity modulated radiation therapy quality assurance (IMRT QA) was peformed to develop a new optimization method of film isocenter offset and to then suggest new quantitative criteria for film dosimetry. Materials and Methods: Film dosimetry was peformed on 14 IMRT patients with head and neck cancers. An optimization method for obtaining the local minimum was developed to adjust for the error in the film isocenter offset, which is the largest part of the systemic errors. Results: The adjust value of the film isocenter offset under optimization was 1 mm in 12 patients, while only two patients showed 2 mm translation. The means of absolute average dose difference before and after optimization were 2.36 and $1.56\%$, respectively, and the mean ratios over a $5\%$ tolerance were 9.67 and $2.88\%$. After optimization, the differences in the dose decreased dramatically. A low dose range cutoff (L-Cutoff) has been suggested for clinical application. New quantitative criteria of a ratio of over a $5\%$, but less than $10\%$ tolerance, and for an absolute average dose difference less than $3\%$ have been suggested for the verification of film dosimetry. Conclusion: The new optimization method was effective in adjusting for the film dosimetry error, and the newly quantitative criteria suggested in this research are believed to be sufficiently accurate and clinically useful.

Excellent Local Tumor Response after Fractionated Stereotactic Radiation Therapy for Locally Recurrent Nasopharynx Cancer (국소 재발 비인강암에 대한 정위적 방사선 분할 치료의 적용)

  • Lim Do Hoon;Chio Dong Rak;Kim Moon Kyung;Kim Dae Yong;Huh Seung Jae;Baek Chung-Hwan;Chu Kwang Chol;Yoon Sung Soo;Park Keunchil;Ahn Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.19-26
    • /
    • 1997
  • Purpose : This study is to report experience with Fractionated Stereotactic Radiation Therapy (FSRT) for locally recurrent nasopharynx cancer after curative conventional radiation therapy. Materials and Methods : Three Patients with locally recurrent and symptomatic nasopharynx cancer were given FSRT as reirradiation method between the Period of September of 1995 and August of 1996 For two Patients, application of FSRT is their third radiation therapy directed to the nasopharynx. Two patients were given low dose chemotherapy as radiation sensitizer concurrently with FSRT Authors used 3-dimensional coordinate system by individually made, relocatable Gill-Thomas-Cosman (GTC) stereotactic frame and multiple non-coplanar arc therapy dose Planning was done using Xknife-3. Total of 45 Gy/18 fractions or 50 Gy/20 fractions were given. Results : Authors observed satisfactory symptomatic improvement and remarkable objective tumor size decrease by follow-up MR images taken 1 month Post-FSRT in ali three patients, while no neurologic side effect attributable to reirradiation was noticed. Two died at 7 and 9 months with loco-regional and distant seeding outside FSRT field, while one patient is living for 4 month. Conclusion Authors experienced satisfactory therapeutic effectiveness and safety of FSRT as reirradiatlon method for locally recurrent nasopharynx cancer Development of more effective systemic chemotherapeutic regimen is desired for distant metastasis

  • PDF

A Study for Effects of Image Quality due to Scatter Ray produced by Increasing of Tube Voltage (관전압 증가에 기인한 산란선 발생의 화질 영향 연구)

  • Park, Ji-Koon;Jun, Je-Hoon;Yang, Sung-Woo;Kim, Kyo-Tae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.663-669
    • /
    • 2017
  • In diagnostic medical imaging, it is essential to reduce the scattered radiation for the high medical image quality and low patient dose. Therefore, in this study, the influence of the scattered radiation on medical images was analyzed as the tube voltage increases. For this purpose, ANSI chest phantom was used to measure the scattering ratio, and the scattering effect on the image quality was investigated by RMS evaluation, RSD and NPS analysis. It was found that the scattering ratio with increasing x-ray tube voltage gradually increased to 48.8% at 73 kV tube voltage and to 80.1% at 93 kV tube voltage. As a result of RMS analysis for evaluating the image quality, RMS value according to increase of tube voltage was increased, resulting in low image quality. Also, the NPS value at 2.5 lp/mm spatial frequency was increased by 20% when the tube voltage was increased by 93 kV compared to the tube voltage of 73 kV. From this study, it can be seen that the scattering radiation have a significant effect on the image quality according to the increase of x-ray tube voltage. The results of this study can be used as basic data for the improvement of medical imaging quality.

Development of Neutron, Gamma ray, X-ray Radiation Measurement and Integrated Control System (중성자, 감마선, 엑스선 방사선 측정 및 통합 제어 시스템 개발)

  • Ko, Tae-Young;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.408-411
    • /
    • 2017
  • In this paper, we propose an integrated control system that measures neutrons, gamma ray, and x-ray. The proposed system is able to monitor and control the data measured and analyzed on the remote or network, and can monitor and control the status of each part of the system remotely without remote control. The proposed system consists of a gamma ray/x-ray sensor part, a neutron sensor part, a main control embedded system part, a dedicated display device and GUI part, and a remote UI part. The gamma ray/x-ray sensor part measures gamma ray and x-ray of low level by using NaI(Tl) scintillation detector. The neutron sensor part measures neutrons using Proportional Counter Detector(low-level neutron) and Ion Chamber Type Detector(high-level neutron). The main control embedded system part detects radiation, samples it in seconds, and converts it into radiation dose for accumulated pulse and current values. The dedicated display device and the GUI part output the radiation measurement result and the converted radiation amount and radiation amount measurement value and provide the user with the control condition setting and the calibration function for the detection part. The remote UI unit collects and stores the measured values and transmits them to the remote monitoring system. In order to evaluate the performance of the proposed system, the measurement uncertainty of the neutron detector was measured to less than ${\pm}8.2%$ and the gamma ray and x-ray detector had the uncertainty of less than 7.5%. It was confirmed that the normal operation was not less than ${\pm}15$ percent of the international standard.

TID and SEL Testing on PWM-IC Controller of DC/DC Power Buck Converter (DC/DC 강압컨버터의 PWM-IC 제어기의 TID 및 SEL 실험)

  • Lho, Young Hwan;Hwang, Eui Sung;Jeong, Jae-Seong;Han, Changwoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.1
    • /
    • pp.79-84
    • /
    • 2013
  • DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The DC/DC converter is composed of a PWM-IC (pulse width modulation-integrated circuit) controller, a MOSFET (metal-oxide semiconductor field effect transistor), inductor, capacitor, etc. It is shown that the variation of threshold voltage and the offset voltage in the electrical characteristics of PWM-IC increase by radiation effects in TID (Total Ionizing Dose) testing at the low energy ${\gamma}$ rays using $^{60}Co$, and 4 heavy ions applied for SEL (Single Event Latch-up) make the PWM pulse unstable. Also, the output waveform for the given input in the DC/DC converter is observed by the simulation program with integrated circuit emphasis (SPICE). TID testing on PWM-IC is accomplished up to the total dose of 30 krad, and the cross section($cm^2$) versus LET($MeV/mg/cm^2$) in the PWM operation is studied at SEL testing after implementation of the controller board.

Fast Neutron Dosimetry in Criticality Accidents (핵임계사고시(核臨界事故時)에 있어서 속중성자선량(速中性子線量)의 해석(解析))

  • Ro, Seung-Gy;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.1 no.1
    • /
    • pp.1-9
    • /
    • 1976
  • A suggestion has been made for neutron dosimetric techniques using activation and threshold detectors in criticality accidents. Neutron dosimetrical parameters, namely, the fission spectrum-averaged cross-sections of some threshold reactions and fluence-to-dose conversion factors have been calculated by the use of an electronic computer. It appears that detectors having comparatively high threshold energy give more fine information on spectral deformation in criticality accidents, while detectors with low threshold energy are of usefulness for measuring fast neutron fluence regardless of fissioning types. Unexpectedly it is found that the fission spectrum-averaged cross sections of the $^{32}S(n,\;p)^{32}P$ reaction is not sensitive to analytical forms of fission neutron spectrum: the modified Cran-berg and Maxwellian forms. In addition, the fluence-to-dose conversion factors seem to be insensitive to both spectral functions and fissioning types.

  • PDF

Radiation Effect on Airway Obstruction from Lung Cancer (폐암으로 유발된 무기폐에 대한 방사선 치료의 효과)

  • Shin, Sei-One;Kim, Sung-Kyu;Kim, Myung-Se
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.2
    • /
    • pp.121-125
    • /
    • 1989
  • Total 21 patients with airway obstruction from lung cancer treated with radiotherapy at Department of Therapeuctic Radiology, Yeungnam University College of Medicine, between April 1986 and December 1988 are retrospectively analysed by means of roentgenologic findings. Obtained results are as follows. 1. 15 out of 21 patients(71%) showed complete or partial response. 2. Patients with small cell lung cancer showed 100% response in spite of low dose(30GY/10 fractions). 3. Patients with non-small cell lung cancer treated with 50GY or over showed better response than below 45GY or below. 4. There is no relationship between the response and site of airway obstruction. These data suggested that high dose irradiation is more effective in the management of airway obstruction from lung cancer and meticulous radiotherapy planning with appropriate protection of normal lung and critical organs should be investigated in order to maximize radiation effect and minimize side effect, complication or sequelae.

  • PDF