• Title/Summary/Keyword: Low voltage DSP

Search Result 98, Processing Time 0.046 seconds

DSP Based Series-Parallel Connected Two Full-Bridge DC-DC Converter with Interleaving Output Current Sharing

  • Sha, Deshang;Guo, Zhiqiang;Lia, Xiaozhong
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.673-679
    • /
    • 2010
  • Input-series-output-parallel (ISOP) connected DC-DC converters enable low voltage rating switches to be used in high voltage input applications. In this paper, a DSP is adopted to generate digital phase-shifted PWM signals and to fulfill the closed-loop control function for ISOP connected two full-bridge DC-DC converters. Moreover, a stable output current sharing control strategy is proposed for the system, with which equal sharing of the input voltage and the load current can be achieved without any input voltage control loops. Based on small signal analysis with the state space average method, a loop gain design with the proposed scheme is made. Compared with the conventional IVS scheme, the proposed strategy leads to simplification of the output voltage regulator design and better static and dynamic responses. The effectiveness of the proposed control strategy is verified by the simulation and experimental results of an ISOP system made up of two full-bridge DC-DC converters.

A Study on Vector Control of ac motor using Low-Voltage DSP (저전압용 DSP칩을 이용한 서보 모터의 벡터제어에 관한 연구)

  • Bang, Seoung-Hyun;Choi, Chi-Young;Hong, Sun-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.76-79
    • /
    • 2002
  • 본 논문에서는 고성능 AC 서보 모터에 대하여 제어 시스템을 구현하고, 제어기를 설계한다. 하드 웨어구성은 모터 전용 저전압 DSP칩인 TMS320LF2407 칩을 이용한다. TMS320LF2407는 최근의 저전력 구동 추세에 따라 3.3V를 구동 전압으로 이용하는 DSP 칩이다 연산 처리 속도는 40MIPS로 빠른 연산 처리능력을 가지고 있지만 주변 소자들과의 인터페이스(보통 5V로 동작)와 노이즈에 대한 대책을 고려하여야 한다. 본 논문에서는 이러한 전압 호환과 노이즈를 가능한 제거한 서보 모터 제어기를 구성하며, 또한 유효 전압 인가시간의 관점에서 바라본 개선된 공간 벡터 PWM방식을 적용함으로써 계산과정과 프로그램을 간단히 하고, 전류제어를 소프트웨어 방식으로 처리하여 복잡한 하드웨어를 간략화 시키고자 한다 이런 과정에 의하여 앞으로 요구될 수 있는 고성능 다기능을 위한 효용성을 높이고자 한다.

  • PDF

Development of a Low Cost VI-Tracer for PV System using LabVIEW and DSP (LabVIEW와 DSP를 이용한 초저가 범용 태양광 발전시스템 VI-Tracer 개발)

  • Kim, Sang-Yong;Park, Sang-Soo;Jang, Seong-Jae;Kim, Gyeong-Hun;Seo, Hyo-Ryong;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1049_1050
    • /
    • 2009
  • This paper deals with development of a low cost VI(Voltage-Currrent)-tracer for PV(Photovoltaic) system using LabVIEW and DSP(Digital Signal Processor). Although the conventional VI-tracer is a high cost equipment, it can‘t abstract the detailed parameters of solar cell. To overcome above mentioned disadvantages, in this paper, a converter type VI-tracer is developed. The DSP, which controls the buck-boost DC-DC converter, is used to implement the proposed VI-tracer algorithm. The proposed VI-tracer can abstract more detailed parameters of solar cell; A(temperature constant), Rs(series resistance), and Rsh(parallel resistance). The authors emphasize that the proposed VI-tracer can satisfy the users who need to get various parameters. A comparison between the proposed VI-tracer and the conventional VI-tracer is presented to show the effectiveness of the proposed system.

  • PDF

Commercial frequency AC discharge magnetic stimulation operating characteristics (상용교류방전 자기자극장치의 동작특성)

  • Kim, Whi-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2685-2692
    • /
    • 2009
  • We propose pulsed magnetic stimulation below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantage of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5Hz to 60Hz to control magnetic stimulation output. In this magnetic stimulation, a low voltage open loop control for high voltage discharge circuit is employed to avoid the HV sampling or switching and high voltage leakage transformer is used to convert rectified low voltage pulse to high voltage one. A ZCS(Zero Cross Switch)circuit and a DSP & FPGA are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leakage inductance. The maximum magnetic stimulation output was obtained about 33W at pulse repetition rate of 60Hz, total 40, 80, 120, $160^{\circ}$, SCR gate trigger angle $90^{\circ}$ and total output.

Predictive Current Control of a Grid-Connected Inverter with Grid Voltage Observer (계통전압 관측기를 이용한 계통연계형 인버터의 예측전류제어)

  • Lee, Kui-Jun;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.159-166
    • /
    • 2010
  • For a grid-connected inverter in distributed generation systems, the current control is essential, and recently, the predictive current control based on a high performance digital signal processors (DSP) to satisfy a fast dynamic response has been widely investigated. However, the performance of predictive current control is degraded by the time delay due to digital implementation, the parameter and measured value errors and the interference of noise, and also theses make system even unstable. Therefore, this paper proposes the predictive current control using grid voltage observer for grid-connected inverter applications. To determine the relevant voltage observer gain, the low-order harmonics of grid voltage are considered, and the effect of filter parameter errors is analyzed. The proposed method has a fast current response capability, the robustness to noise and simple implementation due to voltage sensorless control and the robust current control performance to low-order grid harmonics. The feasibility of the proposed method is verified by simulation and experimental results.

The Improvement Techniques of Characteristics using DSP Chip in Switching Power Converter System (DSP칩을 이용한 스위칭 전력변환 시스템의 특성 개선 기법)

  • Kang Min-Su;Kim Sang-Ug;Im Dong-Gi;Kang Ho-Hyun;Jeon Hee-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.670-672
    • /
    • 2004
  • In this paper, single phase boost converter with low current harmonic components and high power factor are proposed. A single-phase half-bridge rectifier based on a neutral point switch clamped scheme is proposed to draw a nearly unity power factor and regulate the DC link voltage. Three power switches are employed in the proposed rectifier. This rectifier is controlled to generate a bipolar or unipolar PWM voltage waveform on the AC side. The proposed converter is implemented by a digital signal processor.

  • PDF

A Inertia Load Test using a Low Frequency Synchronous PWM Technique of high efficiency for Electric car. (전동차용 고효율 저주파 동기 PWM을 이용한 관성부하 시험)

  • 이광주;정만규;고영철;장성영;방이석
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.233-240
    • /
    • 1998
  • This paper presents a high efficiency low switching PWM technique for the propulsion system of Electric car. In order to achieve the continuous voltage control to six-step and a low harmonics with low switching frequency under 500㎐, the synchronous technique is combined with a space vector overmodulation and implemented by using DSP. Improved performance and a validation of proposed method is shown by the experimental results using a 1.65MVA IGBT VVVF inverter and inertia load equivalent to 160 tons electric cars.

  • PDF

Development of Power Supply for Millimeter-wave Tracking Radars (밀리미터파 추적 레이더용 전원공급기 개발)

  • Lee, Dongju;Choi, Jinkyu;Joo, Ji-Han;Kwon, Jun-Beom;Byun, Young-Jin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.4
    • /
    • pp.123-127
    • /
    • 2021
  • Millimeter-wave tracking radars should be operated in various environmental restrictions, thus they demand more computing power and smaller size compared to conventional tracking radars. This paper presents the design and implementation of the compact power supply for millimeter-wave tracking radar applications. To meet requirements of low voltage/high current and voltage accuracy for FPGA/DSP digital circuits, Point of Load (POL) converters are used in order to enhance power density and system efficiency. LDO (Low Dropout) is applied for the output voltage under the light load condition, then the single-input-multi-output power supply with max power of 375 W and 8 outputs is developed. The proposed power supply achieves output voltage accuracy of ±2 % and noise level of <50 mVpp % under full load conditions.

An Induction Motor Control System with Direct Torque and Flux Control (직접 토크 및 자속제어에 의한 유도전동기 제어시스템)

  • Kim, Min-Huei;Kim, Nam-Hun;Kim, Min-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.79-84
    • /
    • 2000
  • This paper presents an implementation of digital position control system for an induction motor vector drives by a direct torque control(DTC) using the 16bit DSP TMS320 F240. The DSP controller enable enhanced real time algorithm and cost-effective design of intelligent controller for motors which can be yield enhanced operation, fewer system components, lower system cost, increased efficiency and high performance. The system presented are stator flux and torque observer using current model that inputs are current sensing of motor terminal and rotor angle for a low speed operating area, two hysteresis controller, optimal switching look-up table, and IGBT voltage source inverter by fully integrated control software. The developed control system are shown a good motion control response characteristic results and high performance features using 2.2Kw general purposed induction motor.

  • PDF

Real-Time Digital Control of PWM Inverter Empolyed DSP (DSP에 의한 PWM 인버터의 Real-Time Digital 제어)

  • Park, Ga-Woo;Min, Wan-Ki;Choi, Jae-Ho;Choi, Sung-Ryool
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.724-727
    • /
    • 1993
  • This paper is presented real-time digital control techniques of the PWM inverter for UPS. This proposed system is based on instantaneous digital control scheme which is empolyed double dead beat control and prediction method. Especially, to supply the load current from the inverter without the computation delay, the predictive methods are used to generate the load current signal. From the simulation and experimental results, it is shown that presented scheme has good performance such as very low THD of the output voltage, and good dynamic response under the nonlinear load. The experimental implementation of the system is estabilished by using the TMS320C25 DSP.

  • PDF