• Title/Summary/Keyword: Low vision correction

Search Result 31, Processing Time 0.029 seconds

Histogram Modification based on Additive Term and Gamma Correction for Image Contrast Enhancement (영상의 대비 개선을 위한 추가 항과 감마 보정에 기반한 히스토그램 변형 기법)

  • Kim, Jong-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.1117-1124
    • /
    • 2018
  • Contrast enhancement plays an important role in various computer vision systems, since their usability can be improved with visibility enhancement of the images affected by weather and lighting conditions. This paper introduces a histogram modification algorithm that reflects the properties of original images in order to eliminate the saturation effect and washed-out of image details due to the over-enhancement. Our method modifies the original histogram so that an additive term fill histogram pits and the gamma correction suppresses histogram spikes. The parameters for the additive term and gamma correction are adjusted automatically according to statistical properties of the images. Experimental results for various low contrast and hazy images demonstrate that the proposed contrast enhancement improves visibility and reduces haze components effectively, while preserving the characteristics of original images, than the conventional methods.

A Comparison of Pure-Tone Thresholds to the Pre and Post Fogging after Refractive Correction in Normal Eyes (굴절교정된 정상안에서 운무 전후에 따른 순음청력역치의 비교)

  • Cho, Soo-Jin;Joo, Seok-Hee;Lee, Koon-Ja;Choi, In-Sil;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.89-93
    • /
    • 2009
  • Purpose: To purpose of this study was the pure-tone audimetry changes to compare pre and post fogging after visual correction in normally hearing adults. Methods: The estimated that no ocular and audiolar disesases, we selected (male: 30, female: 20) in corrected visual acuity over the 1.0 eye. Pre and post fogging were measured using the pure-tone audimetry. Results: To compared fre and post fogging, fre fogging was higher than fre fogging. The take value were just about every kind of Hz but 200 Hz, respectively which were statistically significant (p<.05). Low Hz area in 250 and 500 Hz were 6.8${\pm}$8.4dBHL, 4.3${\pm}$6.6dBHL, there is not all the difference between any other area, 2000 Hz in the middle Hz area was 0.8${\pm}$4.5dBHL. Conclusions: The study presents different results of measurements in within normal limits. we thought that pure-tone thresholds to the pre and post fogging after refractive correction in normal adults and would be used basic data.

  • PDF

A Study on FPGA Design for Rotating LED Display Available Video Output (동영상 표출이 가능한 회전 LED 전광판을 위한 FPGA 설계에 관한 연구)

  • Lim, Young-Sik;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.168-175
    • /
    • 2015
  • In this paper, we propose FPGA design technique for rotating LED display device which is capable of displaying videos with the use of the afterimage effect. The proposed technique is made up of image data correction process based on inverse gamma correction and error diffusion, block interleaving process, and data serial output process. The data correction process based on inverse gamma correction and error diffusion is an image data correction step in which image data received are corrected by inverse gamma correction process to convert the data into linear brightness characteristics, and by error diffusion process to reduce the brightness reduction phenomenon in low-gray-level which is caused by inverse gamma correction. In the block interleaving process, the data of the frames entered transversely are first saved in accordance with entrance order, and then only the longitudinal image data are read. The data serial output process is applied to convert the parallel data in a rotating location into serial data and send them to LED Driver IC, in order to send data which will be displayed on high-speedy rotating LED Bar. To evaluate the accuracy of the proposed FPGA design technique, this paper used XC6SLX45-FG484, a Spartan 6 family of Xilinx, as FPGA, and ISE 14.5 as a design tool. According to the evaluation analysis, it was found that goal values were consistent with simulation values in terms of accurate operation of inverse gamma and error diffusion correction, block interleaving operation, and serialized operation of image data.

The Robust Skin Color Correction Method in Distorted Saturation by the Lighting (조명에 의한 채도 왜곡에 강건한 피부 색상 보정 방법)

  • Hwang, Dae-Dong;Lee, Keunsoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1414-1419
    • /
    • 2015
  • A method for detecting a skin region on the image is generally used to detect the color information. However, If saturation lowered, skin detection is difficult because hue information of the pixels is lost. So in this paper, we propose a method of correcting color of lower saturation of skin region images by the lighting. Color correction process of this method is saturation image acquisition and low-saturation region classification, segmentation, and the saturation of the split in the low saturation region extraction and color values, the color correction sequence. This method extracts the low saturation regions in the image and extract the color and saturation in the region and the surrounding region to produce a color similar to the original color. Therefore, the method of extracting the low saturation region should be correctly preceding. Because more accurate segmentation in the process of obtaining a low saturation regions, we use a multi-threshold method proposed Otsu in Hue values of the HSV color space, and create a binary image. Our experimental results for 170 portrait images show a possibility that the proposed method could be used efficiently preprocessing of skin color detection method, because the detection result of proposed method is 5.8% higher than not used it.

The Factors Influencing the Asthenopia of Myopia with Phoria (사위를 가진 근시안의 안정피로에 영향을 미치는 요인)

  • Kim, Jung-Hee;Kim, Chang-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.419-428
    • /
    • 2005
  • The aim of this study was to provide data for the relief of asthenopia during binocular vision by determining the characteristics of ocular function in adults. A total of 260 subjects were between the age of 19-35years. We measured individually the refractive error correction, pupillary distance, optical center distance, phoria, convergence, accommodation and the AC/A as well as the asthenopia during binocular vision using a questionnaire. After analysis of factors affecting asthenopia, we also examined the reductive effect of asthenopia in subjects who had asthenopia using prism. To determine the factors affecting asthenopia during binocular vision, statistic analyses were carried out the multivariate Logistic regression model. The results of this study were as follow. The asthenopia during binocular vision was found 26.9% of subjects. Multivariate logistic regression model was used to determine factors affecting binocular vision of myopia. When the accommodation and convergence were low compared to being high, when subjects had esophoria or there was more exophoria, and when AC/A was lower than the standard, the rate of asthenopia was higher. Therefore the accommodation, convergence and AC/A could be predictive factors for asthenopia. We used prism for subjects who had asthenopia during binocular vision, the results showed that the symptom of asthenopia was eased up to 74.3%.

  • PDF

A Clinical Study of Ocular Dimention and Visual Acuity Before and After Cataract Surgery Over Ninety Years Old (90세 이상 초고령 환자들의 백내장 수술전.후 안수치와 시력에 관한 임상연구)

  • Lee, Jung-Mi;Kim, In-Suk;Shin, Jin-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.275-280
    • /
    • 2010
  • Propose: Due to the rapid growth of medical technologies and the increasing population of older people, we investigated clinical status of ocular dimensions and visual acuity for pre and post cataract surgeries of people over age 90. Methods: From March 2007 to February 2009, we investigated eighty-two eyes of forty-eight patients who had undergone cataract surgeries at an ophthalmic clinic (Ansung, Kyungi-do), investigated maximum corrected vision, axial length, anterior chamber depth and accompanied ocular diseases before and after the surgeries based on the collected data. Results: As patients aged, axial length unchanged but anterior chamber depth decreased over all due to the increase of intraocular lens thickness, and men tended to have a higher degree than women. Seventy-one (86.6%) of eighty-two eyes showed improved corrected vision than before surgeries and forty-three (52.4%) eyes could see more than visual acuity of 0.5. Conclusions: Patients with the systemic disease and accompanied ocular disease showed low vision less than 0.5 after cataract surgery compared to same healthy age peoples. But the others improved correction visual acuity more than 0.5, so the cataract surgery was surely necessary for people over 90 years old and also the presence of ocular disease could have a great influence on correction visual acuity.

Comparison of Dynamic Stereoacuity According to Dominant Eye and Degree of Dominant Eye (우세안의 방향과 강도에 따른 동적 입체시 비교)

  • Shim, Moon-Sik;Shim, Hyun-Suk;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.227-233
    • /
    • 2016
  • Purpose: On this study, we compared the relationship of dynamic stereoacuity according to the dominant eye, degree of dominant eye, and dominant agreement eye and hand. Methods: For 130 adults (male 70, female 60), mean age of $21.06{\pm}2.21years$ old, dominant eye, degree of dominant eye were measured by objective examination by using the diameter $3.8cm{\times}3.8cm$ thin ring, the dynamic stereoacuity were measured by three-rods test (iNT, Korea). Results: Dynamic stereoacuity according to the dominant eye was center dominant eye without dominance was $14.97{\pm}13.80sec$ of arc, right eye $22.10{\pm}20.01sec$ of arc, left eye $22.31{\pm}20.39sec$ of arc. Dynamic stereoacuity was better when there was no dominance, but the correlation of the dominant eye with dynamic stereoacuity was very low. When Dynamic stereoacuity was separated by in the Center, Mild, Strong, dynamic stereoacuity was $14.97{\pm}13.80sec$ of arc, $20.76{\pm}15.73sec$ of arc and $24.45{\pm}25.60sec$ of arc respectively. The dynamic stereoacuity results were worse when dominance was stonger. However dynamic stereoacuity was better than Center when the degree of dominant eye was rather strong in the dominant left eye. Dynamic stereoacuity according to the dominant eye and hand showed that right eye and hand was $22.63{\pm}20.54sec$ of arc, left eye and hand was $17.36{\pm}10.13sec$ of arc, right eye and left hand was $14.79{\pm}7.05sec$ of arc, left eye and right hand was $22.97{\pm}21.42sec$ of arc so dynamic stereoacuity was comparatively good when the dominant hand was left. Conculsions: Correlation between the dynamic stereoacuity according to the dominant eye, degree of dominant eye was low, however when degree of dominant eye was Center 14.97 sec of arc, Strong 24.45 sec of arc, the dynamic stereoacuity tended to worse when degree of dominant eye was strong. As a result, dominant eye, degree of dominant eye would have to be considered in a more comfortable binocular balance between prescribed for the wearer in binocular vision correction in binocular function such stereoacuity, sports vision training, presbyopia correction and mono vision.

Assessment of UV Blocking Performance for Development of Converged Technologies of Vision Correcting Spectacle Lenses (시력교정용 안경렌즈의 융복합적 기술개발을 위한 UV차단 성능 평가)

  • Kim, Heung-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.4
    • /
    • pp.93-98
    • /
    • 2018
  • This study was wanted to confirm ability for UV blocking according to its material. The lenses materials were Acryl, CR-39, NK-55, and MR-8. It was grouped: Group A consisting of anti-scratch hard coated lenses and anti-refractive multi coated lenses, Group B added UV blocking coating on the group A, and Group C consisting of only UV blocking lenses. The results measured UV transmittance, On the UV-A wavelength, Group A showed the UV transmittance of 7.726%, 0.043%, 0.007%, and 0.007% respectively. Group B showed 0.038%, 0.037%, 0.007%, and 0.007%, respectively. The UV-blocking performance of CR-39 has been greatly improved. Group C has shown the best UV blocking function; only 0.005% and 0.004% of UV transmittances.(1.60 and 1.67 index of refraction respectively). For the low power of lenses and sunglasses, the CR-39 lens is the most used. Therefore, to UV blocking from the lens, new materials or UV absorbers or UV coating technology and development of Converged Technologies are required.

Preference and Readability of Hangul Fonts in the Presbyopic Age (노안 연령에서 한글서체의 선호도와 가독성 평가)

  • Jeung, Shinhae;Son, Jeong-Sik;Hwang, Hae-Young;Kim, Seong Kun;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.149-156
    • /
    • 2013
  • Purpose: The aim of this study was to determine a suitable type and size of Hangul fonts for printed materials in the presbyopic age. Methods: Based on the most common Hangul fonts used today, three types of fonts were used Hamchrombatang, Sinmoonmyungjo and Sinmyungjo at small font sizes in the range 9-11 point (pt). Subjects were 101 volunteers aged 41 through 85 years. Near visual acuity (VA) was corrected to read VA 0.5 at 40 cm after distance correction. The subjects were asked to read words containing 88 characters in 10 pt after a question about preference. Readability was assessed by reading rate that was calculated as the number of words read correctly in one minute (words per minute, wpm). Results: The most preferred font type was Simmyungjo at small font sizes. Although preferred font sizes were different in each font type, Sinmyungjo was generally preferred at 10 pt more than other fonts. Hamchrombatang and Sinmyungjo were read significantly faster than Sinmoonmyungjo. There was a weak negative relationship between readability and age in Sinmyungjo. In comparing between the top 10% and the bottom 10% group sorted by reading rate, the top group showed lower average age and addition than the bottom group, however there were no significant differences in reading rate among the fonts. Conclusions: Although increasing age tends to be low in readability for Sinmyungjo, in the light of preferred font and readability, it is recommended to use a 10 pt Sinmyungjo font in printed materials for the presbyopic age.

A Survey of Foreign Consumers Satisfaction with Eye-wear Products in Korea According to Nationality (외국인 소비자 국적에 따른 한국 안경 제품 구매에 대한 만족도 조사)

  • Kim, Guen-Hei;An, Hyo-Jo;Jeon, Ji-Eun;Noh, Hyeran
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.397-404
    • /
    • 2015
  • Purpose: To investigate consumer satisfaction of foreigners with eye-wear products in Korea. Methods: Foreigners (n=106, United State/Canada, Japan, China, or other Asia) who have purchased the products at optical shops in Korea, were volunteered. Satisfaction factors were categorized into 6 divisions (products, price, vision correction, facilities, kindless, description). Results: The most frequently purchased products were eye-glasses (62%) and sunglasses (25%) by foreigners at Korea's optical shops. Quality satisfaction of the products was higher to Chinese and other Asians than to American, Canadian and Japanese. Price satisfaction was higher to Japanese, American, and Canadian than to Chinese and other Asians. Vision correction and facilities satisfaction were appeared relatively low from American and Canadian. Product descriptions and kindness were, in general, lower than other categories to all nationalities. Conclusions: Satisfaction about eyewear were significantly different depending on the nationality of the foreigner. Based on the various categories of the consumer satisfaction, ethnically customized marketing strategy would be possible to foreigners who stays in Korea.