• Title/Summary/Keyword: Low temperature treatment

Search Result 1,965, Processing Time 0.027 seconds

Slip-resistant bolted connections under freeze-thaw cycles and low temperature

  • A. Fuente-Garcia;M.A. Serrano-Lopez;C. Lopez-Colina;F., Lopez-Gayarre
    • Steel and Composite Structures
    • /
    • v.48 no.3
    • /
    • pp.251-262
    • /
    • 2023
  • There are many examples of steel structures subjected to severe environmental conditions with bolted connections directly exposed to extreme climatic agents such as freeze-thaw cycles or low temperatures. Some examples are: steel bridges, mining transfer towers, wind towers... These service conditions neither are included in Eurocode 3 or EN1090-2, nor there are references in other international standards. In this experimental research, 46 specimens of non-slip joints with HV M20 bolts and four different types of contact surfaces have been studied. Half of the specimens were subjected to fourteen twelve-hours freeze-thaw cycles, with periodic immersion in water and temperature oscillation. Subsequently, half of the connections were subjected to a slip test under monotonic load at temperature of -20 ± 0.5 ℃ and the other half at room temperature. The results were compared with others equal joints not subjected to freeze-thaw cycles and kept at room temperature for the same time. This finally resulted in 4 sets of joints by combining the freeze-thaw degradation or not with the low-temperature conditions or not in the slip testing. Therefore, a total of 16 different conditions were studied by also considering 4 different contact surfaces between the joined plates in each set. The results obtained show influence of environmental conditions on the slip resistant capacity of these joints.

Effects of Low Temperature Retrogression on RRA Treatment of 7075 AI Alloy (7075 Al합금의 RRA처리에서 저온 퇴화처리의 효과)

  • Kim, Chang-Joo;Lee, Jung-Moo
    • Korean Journal of Materials Research
    • /
    • v.4 no.1
    • /
    • pp.24-30
    • /
    • 1994
  • Effect of low temperature retrogression on RRA treatment were investigated in the thermomechanically treated 7075 Al alloy. The complete dissolution of GP zones did not occur during retrogression at $170^{\circ}C$ in T6 material. llrop in strength during initial stage of retrogression was due to the partial dissolution of GP zones. And the strength increased with the formation of $\mu '$ and decreased again with the growth of $\mu '$ and/or formation of $\mu '$ When RRA treatment was applied at the minimum or the secondary peak (maximum) in the hardness curve of retrogression treatment, SCC property was improved markedly without reduction of the strength in comparision with that of T6 materials. And the rhanges in the matrix were not sensitive with time during retrogression at low temperature of $170^{\circ}C$ that the strength and SCC properties were similar at both points in the hardness curve of retrogression treatment.

  • PDF

Influence of low temperature degradation on the bond strength and flexural Strength of veneered Zirconia(3Y-TZP) (저온열화가 도재전장 지르코니아의 결합강도와 굴곡강도에 미치는 영향)

  • Lee, Jung-Hwan;Ahn, Jae-Seok
    • Journal of Technologic Dentistry
    • /
    • v.33 no.3
    • /
    • pp.193-202
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the effect of pre-treatment of core and hydrothermal treatment on the bond strength and flexural strength of ceramic veneered zirconia. Methods: 3Y-TZP specimens(KaVo Zr, $25mm{\times}3mm{\times}1mm$)were prepared by five pre-treatment methods and divided into seven groups including control two groups, subsequently the specimens veneered with the E-MAX ceram according to manufacturer's information(total specimen thickness 1.5mm). Two groups from ceramic-zirconia specimens(n=105, n=15 per group)were assigned into two experimental fatigue conditions, namely storage in an autoclave at $134^{\circ}C$ for 5h, thermo-cycling(3,000cycles, between 5 and $55^{\circ}C$, dwell time 45s, transfer time 2s). A flexural strength test was performed in a universal testing machine(crosshead speed: 0.5mm/min). Data were statistically analyzed using one-way ANOVA and Tukey's test(${\alpha}$=0.05). Results: The ceramic-zirconia bond strength value for liner application group(LLW, $27.3{\pm}3.8$) were significantly lower than those of the pre-treatment groups($30.72{\pm}5.3$). The ceramic-zirconia bond strength and zirconia flexural strength was not affected by thermo-cycling(p>0.05), whereas it was affected by storage in an autoclave at $134^{\circ}C$ for 5h(p<0.05). Conclusion: The results indicated that the ceramic-zirconia bond strength and zirconia flexural strength was affected by low temperature degradation.

Improvement of Rate Capability and Low-temperature Performances of Graphite Negative Electrode by Surface Treatment with Copper Phthalocyanine (구리 프탈로시아닌으로 표면처리된 흑연 음극의 속도특성 및 저온성능 개선)

  • Jurng, Sunhyung;Park, Sangjin;Ryu, Ji Heon;Oh, Seung M.
    • Journal of the Korean Electrochemical Society
    • /
    • v.18 no.3
    • /
    • pp.130-135
    • /
    • 2015
  • The rate capability and low-temperature characteristics of graphite electrode are investigated after surface treatment with copper phthalocyanine (CuPc) or phthalocyanine (Pc). Uniform coating layers comprising amorphous carbon or copper are generated after the treatment. The rate performance of graphite electrodes is enhanced by the surface treatment, which is more prominent with CuPc. The resistance of the graphite electrode estimated from electrochemical impedance spectroscopy and pulse resistance measurement is the smallest for the CuPc-treated graphite. It is likely that the amorphous carbon layer formed by the decomposition of Pc facilitates $Li^+$ diffusion and the metallic copper derived from CuPc improves the electrical conductivity of the graphite electrode.

Quality improvement and aging effect of beef by low-temperature treatment of non-preferred parts of beef (비선호 부위 소고기의 저온처리에 의한 품질향상 및 소고기의 숙성효과)

  • Hyun Kyoung Kim;Soon Cheol Kim;Hyeon Jin Kim;Yeong Mi Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.753-760
    • /
    • 2023
  • In this study, quality improvement of beef was attempted according to the low temperature treatment and aging period of grade 1 compared to grade 1++ beef. The fat content and shear force of beef grade 1++ were 13.03% and 114.26N, but beef grade 1 was 3.21% and 149.67N. Meanwhile, after low-temperature treatment of grade 1 beef at -26℃ for 12 hours and low-temperature aging at 0 ℃ for 14 days, the shear force was greatly reduced to 87.85N, improving overall preference, softness, dripping gravy, flavor, and chewing texture. The essential free amino acid content was as low as 22.17mg/100g in grade 1++ beef, but the contents were high at 41.31~45.11mg/100g in three samples of grade 1, and there was no change in content according to cold treatment conditions. As a specific component of beef, Taurine was 30.94~34.41mg/100g, and the difference in content was small according to beef grade, but Anserine and Creatine were low at 19.68mg/100g and 70.01mg/100g in beef grade 1++ and high at 26.38~31.23mg/100g and 154.09~167.26mg/10g in beef grade 1. The content ratio of oleic acid (c18:1)/stearic acid (c18:0) as an monounsaturated fatty acid/saturated fatty acid ratio was low at 5.29 for grade 1++ beef, but high at 6.13~6.78 for grade 1 beef. In addition, there was no trend in the content ratio of these fatty acids according to the low-temperature treatment conditions and aging period in beef grade 1. As a result of this study, it was possible to improve the quality of beef grade 1 by low-temperature treatment at -26 ℃ for 12 hours and then aging at 0 ℃ for 14 days.

Effects of Vacuum Heat Treatment and Salt bath Heat Treatment Conditions on Mechanical Properties of High Speed tool Steel (금속도 공구강의 기계적 성질에 미치는 진공열처리와 염욕열처리 조건의 영향)

  • Kim, Je-Don;Kim, Kyung-Sik
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.26 no.1
    • /
    • pp.7-13
    • /
    • 2013
  • Vacuum heat treatment(indirect heating method) has long exposure time at high temperature and low quenching rate. Contrarily salt bath heat treatment (direct heating method) has short exposure time at high temperature and fast cooling rate. With these different features of processes, mechanical properties such as hardness, tensile strength and impact strength of products show very different results. In this study, Salt bath heat treated products showed higher tensile strength and impact strength than vacuum heat treated products but hardness was not much different. These lower mechanical properties of vacuum heat treated products are due to differences in heat process and secondary hardening with high temperature tempering process. Consequently, It indicates that salt bath heat treatment is better way than vacuum heat treatment for product to have high mechanical properties.

Processing of Low Tin Zr-1Nb-0.69Sn-0.11Fe Alloy Tubes and Effect of Final Heat Treatment on Their Mechanical and Corrosion Properties (저 Sn 함유 Zr-Nb-Sn-Fe 합금 튜브 제조 및 최종 열처리 온도에 따른 기계적/부식특성 변화)

  • Cho, Nam Chan;Lee, Jong Min;Hong, Sun Ig
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.1
    • /
    • pp.17-24
    • /
    • 2011
  • To investigate the relationship between heat treatment in zirconium alloy tubing process and metallurgical characteristics of Zr-1Nb-0.69Sn-0.11Fe alloy tubes, mechanical and oxidation behaviors of tubes heat treated at different temperatures after the final pilgering were investigated. The stress strain curves exhibited the saturation behaviors in all heat treatment conditions ($460{\sim}600^{\circ}C$) in this study with the onset strain of saturation increased with increase of post-pilgering annealing temperature. The strength fell off rapidly with increasing annealing temperature. The ultimate strength of the low tin Zr-1Nb-0.69Sn-0.11Fe alloy with slightly higher iron and oxygen contents in this study was found to be higher than Zr-1Nb-1Sn-0.1Fe alloy. The oxidation experiments in steam condition revealed that the corrosion resistance of low tin Zr-1Nb-0.69Sn-0.11Fe alloy was better than the Zr-1Nb-1Sn-0.1Fe alloy with a higher Sn content. The weight gain of low tin Zr-1Nb-0.69Sn-0.11Fe alloy tubes gradually increased with the increasing annealing temperature possibly due to the decreased Nb content in the matrix because of the formation of ${\beta}-Nb$ particles.

Effect of Heat Treatment on the Physical Properties of LM PET Jacquard Fabrics (저융점 폴리에스터 자카드직물의 물성에 대한 열처리 효과)

  • Lee, Sun Young;Kim, Jeong Hwa;Kim, Eui Hwa;Lee, Jung Soon;Lee, Seung Goo
    • Textile Coloration and Finishing
    • /
    • v.25 no.3
    • /
    • pp.206-214
    • /
    • 2013
  • There has been an increasing demand for high performance and energy-saving of blind. In order to develop the eco-friendly blind textiles, heat treatment process has been utilized for LM(Low Melting) polyester fabrics and the changes of the physical properties of the treated fabrics were examined according to temperature of heat treatment. Morphology, surface reflectance, contact angle, luster, thermal property and mechanical property of heat treated LM polyester fabrics were investigated. As results, morphology analysis of thermal treated fabrics confirmed that degree of fusion of LM polyester yarns improved with increase of temperature. Surface reflectance of thermal treated fabrics decreased with increase of temperature. Luster and contact angle of a water droplet on thermal treated fabrics increased slightly with increase of temperature. The mechanical properties of the fabrics by KES-FB system were found to be temperature-dependent and especially, bending and shear properties among them were highly related to temperature.

Thermal Stability of Silicon-containing Diamond-like Carbon Film (실리콘 함유 DLC 박막의 내열특성)

  • Kim, Sang-Gweon;Kim, Sung-Wan
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.2
    • /
    • pp.83-89
    • /
    • 2010
  • Diamond-like carbon (DLC) coating was studied to be a good tribological problem-solver due to its low friction characteristics and high hardness. However, generally hydrogenated DLC film has shown a weak thermal stability above $300^{\circ}C$. However, the silicon doping DLC process by DC pulse plasma enhanced chemical vapor deposition (PECVD) for the new DLC coating which has a good characterization with thermal stability at high temperature itself has been observed. And we were discussed a process for optimizing silicon content to promote a good thermal stability using various tetramethylsilane (TMS) and methane gas at high-temperature. The chemical compositions of silicon-containing DLC film was analyzed using X-ray photoelectron spectroscopy (XPS) before and after heat treatment. Raman spectrum analysis showed the changed structure on the surface after the high-temperature exposure testing. In particular, the hardness of silicon-containing DLC film showed different values before and after the annealing treatment.

Effects of the Heat-Treatment on the Nutritional Quality of Milk - I. Historical Development of the Heat-Treatment Technology in Milk - (우유의 열처리가 우유품질과 영양가에 미치는 영향 - I. 우유 열처리 기술의 발달사 -)

  • Jung, Anna;Oh, Sejong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.34 no.4
    • /
    • pp.271-278
    • /
    • 2016
  • The main purpose of milk heat-treatment is to improve milk safety for consumer by destroying foodborne pathogens. Secondly, heat-treatment of milk is to increase maintaining milk quality by inactivating spoilage microorganisms and enzymes. Pasteurization is defined by the International Dairy Federation (IDF, 1986) as a process applied with the aim of avoiding public health hazards arising from pathogens associated with milk, by heat treatment which is consistent with minimal chemical, physical and organoleptic changes in the product. Milk pasteurization were adjusted to $63{\sim}65^{\circ}C$ for 30 minutes (Low temperature long time, LTLT) or $72{\sim}75^{\circ}C$ for 15 seconds (High temperature short time, HTST) to inactivate the pathogens such as Mycobacterium bovis, the organism responsible for tuberculosis. Ultra-high temperature processing (UHT) sterilizes food by heating it above $135^{\circ}C$ ($275^{\circ}F$) - the temperature required to destroy the all microorganisms and spores in milk - for few seconds. The first LTLT system (batch pasteurization) was introduced in Germany in 1895 and in the USA in 1907. Then, HTST continuous processes were developed between 1920 and 1927. UHT milk was first developed in the 1960s and became generally available for consumption in the 1970s. At present, UHT is most commonly used in milk production.