• Title/Summary/Keyword: Low power systems

Search Result 2,399, Processing Time 0.037 seconds

A Study on the efficiency of AM Broadcast Transmitting Antenna in assordance with a low noise Area (저잡음지역(3.5mV/m)의 AM방송송신 안테나 효율에 관한 연구)

  • 이문호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.5 no.1
    • /
    • pp.40-43
    • /
    • 1980
  • The Service area in AM Broadcast Changes according to its transmitting frequency. It is also reduced by increase of the citizen noise. As a result, the efficency of transmitting Antenna should be higer in a low noise region as long as AM Broadcast does not build up its transmitting power. The efficiency of transmitting Antenna can also function as a low resistance connection to earth. Most Vertical Antenna used in the AM standard Broadcast band in the Korea have extensive radial ground systems beneath them which serve as image plane.

  • PDF

The study for two phase SRM with self starting capability (자기동이 가능한 2상 SRM에 관한 연구)

  • Oh, Seok-Gyu
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.226-228
    • /
    • 2007
  • SRM drive systems are designed to meet operating standards such as low cost, constant torque independent of rotor position, a desired operating speed range, high efficiency, and high performance. In applications using small motors, low cost and high performance with self-starting capabilities are highly desired. This paper discusses a novel two phase SRM (TPSRM) that has high performance characteristics with self-starting capability, low manufacturing cost with a two phase inverter and simple magnetic structure, and high efficiency. The principle of operation, analysis, and simulation for design are presented. The machine design is verified using finite element analysis (FEA) software. Analysis and simulation results are given to validate the TPSRM design.

  • PDF

Evaluation of self-heating propensity and its relation with fuel properties of various coals (다양한 탄종별 자체발열 특성과 물성의 비교 분석)

  • Kim, Jungsoo;Lee, Yongwoon;Im, Hyeon Soo;Park, Hoyoung;Ryu, Changkook
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.83-85
    • /
    • 2013
  • With an increase in the use of low rank coals in power plants, various operational issues were raised in the fuel storage and supply, combustion, boiler and flue gas treatment systems. In the fuel storage and supply system, the main issue is the self-heating propensity of low rank coals leading to spontaneous combustion in yard storage, transport and pulverization. This study evaluated the reactivity of various sub-bituminous and bituminous coals with oxygen at low temperatures by analyzing the temperature increase characteristics of coals under a constant flow rate of oxygen supply. The results were quantified to a self-heating index and the relation with the fuel properties were evaluated.

  • PDF

A Study of Improving Regenerative Energy Utilization in Urban DC Railway Systems Through Sharing Substations (철도 변전소 공유를 통한 직류 도시철도 시스템 회생에너지 이용률 향상 방안 연구)

  • Jung, Seung-Min;Lee, Han-Sang;Byun, Gil-Sung;Kwon, Sae-Hyuk;Jang, Gil-Soo;Jung, Ho-Sung;Kim, Hyung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2392-2396
    • /
    • 2011
  • This paper deals with the power integration of large urban railway systems to improve regenerative energy utilization. Current regenerative energy utilization is low because there is no special plan for using this energy. If the railway system is integrated with other railway systems, the efficiency is expected to be improved. Through the case studies, to find the realistic effect of integrated operation, real system for the Seoul Metro lines, especially line 5 and 7, had been applied.

Development of a General Purpose PID Motion Controller Using a Field Programmable Gate Array

  • Kim, Sung-Su;Jung, Seul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.360-365
    • /
    • 2003
  • In this paper, we have developed a general purpose motion controller using an FPGA(Field Programmable Gate Array). The multi-PID controllers on a single chip are implemented as a system-on-chip for multi-axis motion control. We also develop a PC GUI for an efficient interface control. Comparing with the commercial motion controller LM 629 it has multi-independent PID controllers so that it has several advantages such as space effectiveness, low cost and lower power consumption. In order to test the performance of the proposed controller, robot finger is controlled. The robot finger has three fingers with 2 joints each. Finger movements show that position tracking was very effective. Another experiment of balancing an inverted pendulum on a cart has been conducted to show the generality of the proposed FPGA PID controller. The controller has well maintained the balance of the pendulum.

  • PDF

A floating resistor with positive and negative resistance operating at lower supply voltages

  • Tantry, Shashidhar;Oura, Takao;Yoneyama, Teru;Asai, Hideki
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.325-328
    • /
    • 2002
  • In this paper. we propose a floating resistor with positive and negative resistance operating at lower supply voltages. The circuit uses only two transistors between the supply voltages. which enable to operate it at low supply voltages. Moreover. the circuit uses fewer number of transistors compared to the reported work. The gate terminal is used in this circuit for the current addition/subraction at the terminals of resistor. The characteristic of the proposed circuit is verified using HSPICE for the power supply +/-1.5V.

  • PDF

Study on Active Damper System Applying DC-Motor (DC Motor를 이용한 능동형 댐퍼 시스템에 대한 연구)

  • Lee, Hak-Cheol;Jeon, Jin-Young;Jeong, Young-Suk
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.121-123
    • /
    • 2008
  • The suspension systems currently in use can be classified as passive, semi-active and active. The passive suspension systems are the most commonly used due their low price and high reliability. However, this system cannot assure the desired performance form a modern suspension system. An important improvement of suspension performance is achieved by the active systems. This paper treats active damper system and applying DC-Motor. In this system, all the energy for active control is supplied from the damper, which regenerates energy. And simulations by sky-hook control.

  • PDF

Image Objects Detection Method for the Embedded System (임베디드 시스템을 위한 영상객체의 검출방법)

  • Kim, Yun-Il;Rho, Seung-Ryong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.4
    • /
    • pp.420-425
    • /
    • 2009
  • In this paper, image detection and recognition algorithms are studied with respect to embedded carrier system. There are many suggested techniques to detect and recognize objects. But they have the propensity to need much calculation for high hit rate. Advanced and modified method needs to study for embedded systems that low power consumption and real time response are requested. The proposed methods were implemented using Intel(R) Open Source Computer Vision Library provided by Intel Corporation. And they run and tested on embedded system using a ARM920T processor by cross-compiling. They showed 1.6sec response time and 95% hit rate and supported the automated moving carrier system smoothly.

A Study on the Seismic Performance of MR Fluid Dampers in Base-Isolated Structures (기초격리된 구조물에서 자기유동성 유체감쇠기의 면진성능에 관한 연구)

  • 이종세;도학용
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.371-378
    • /
    • 2002
  • The design concepts using vibration reduction techniques, or structural control, have been proposed recently to protect infrastructure against earthquakes. The magnetorheological(MR) fluid damper is one of the most promising new devices for structural vibration reduction because of its mechanical simplicity, high dynamic range, low power requirement, large force capacity and robustness. In this study, the seismic performance of MR devices are compared with that of NZ systems as an attempt to provide some data for improving seismic design techniques applied to structures. For nonlinear time domain analysis of a base isolation system, a six-story building model is considered as a numerical example. The ground acceleration data of El Centre 1940, Mexico City 1985 and Kobe 1995 earthquakes are used as seismic excitations. The results show that MR damper systems for outperform NZ systems in wide-ranging seismic excitations with respect to intensity and period characteristics.

  • PDF

Experimental Study for Effective Flow and Force Area of Discharge Valve System in a Linear Compressor (리니어 압축기 토출밸브계의 유효 유동면적 및 힘면적에 관한 실험적 연구)

  • Lee Byung-Chan;Lee Hyuk;Ahn Tae-Kil
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.7 s.184
    • /
    • pp.122-129
    • /
    • 2006
  • The linear compressor has lately attracted considerable attention because of its low power consumption and excellent efficiency. For an efficient design, it is necessary to develop an analytical model of the linear compressor. The effective flow and force areas are important parameters to describe the behavior of the linear compressor, which are used to determine the mass flow rates through the valving systems and the forces on the valves, respectively. It is not easy to estimate these parameters because shapes of the valve systems of the linear compressor are so different from those of tile conventional valve systems. In this paper, we suggest method to measure experimentally the effective discharge flow and force areas of the linear compressor and analyze valve characteristic to apply the experimental results to their theoretical model.