• 제목/요약/키워드: Low power systems

검색결과 2,393건 처리시간 0.034초

극 수에 따른 저압직류 배전계통의 순시전압강하 분석 (Analysis on Voltage Sag in Low Voltage DC Distribution System according to the Number of Poles)

  • 노철호;김두웅;권기현;오윤식;한준;김철환
    • 조명전기설비학회논문지
    • /
    • 제29권11호
    • /
    • pp.66-73
    • /
    • 2015
  • AC-based power systems, having the advantages that voltage transformation and long distance transmission are easy, have been constructed since the last 19th century. However, DC-based power system is paid attention these days because of the development of power electronic devices as well as the increase of digital loads and distributed generation. For instance, the transmission systems using High Voltage DC (HVDC) are commercially operated in the world and the researches on distribution system using Low Voltage DC (LVDC) are gradually increased. This paper analyzes voltage sag, resulted from faults, in LVDC distribution system according to the number of poles. Modeling and simulation with various conditions are conducted by using ElectroMagnetic Transients Program (EMTP). Moreover, some countermeasures to reduce voltage sag in LVDC distribution system are suggested briefly.

A low cost miniature PZT amplifier for wireless active structural health monitoring

  • Olmi, Claudio;Song, Gangbing;Shieh, Leang-San;Mo, Yi-Lung
    • Smart Structures and Systems
    • /
    • 제7권5호
    • /
    • pp.365-378
    • /
    • 2011
  • Piezo-based active structural health monitoring (SHM) requires amplifiers specifically designed for capacitive loads. Moreover, with the increase in number of applications of wireless SHM systems, energy efficiency and cost reduction for this type of amplifiers is becoming a requirement. General lab grade amplifiers are big and costly, and not built for outdoor environments. Although some piezoceramic power amplifiers are available in the market, none of them are specifically targeting the wireless constraints and low power requirements. In this paper, a piezoceramic transducer amplifier for wireless active SHM systems has been designed. Power requirements are met by two digital On/Off switches that set the amplifier in a standby state when not in use. It provides a stable ${\pm}180$ Volts output with a bandwidth of 7k Hz using a single 12 V battery. Additionally, both voltage and current outputs are provided for feedback control, impedance check, or actuator damage verification. Vibration control tests of an aluminum beam were conducted in the University of Houston lab, while wireless active SHM tests of a wind turbine blade were performed in the Harbin Institute of Technology wind tunnel. The results showed that the developed amplifier provided equivalent results to commercial solutions in suppressing structural vibrations, and that it allows researchers to perform active wireless SHM on moving objects with no power wires from the grid.

센서 기반 사용자 상태 인식 알고리즘을 이용한 저전력 서비스에 관한 연구 (Study on the Low Power Service with User State Recognition Algorithm Using Sensors)

  • 이도경;홍원기;차경애
    • 대한임베디드공학회논문지
    • /
    • 제10권2호
    • /
    • pp.91-99
    • /
    • 2015
  • The electric power consumed by the embedded devices has become a critical issue because the reduction of power consumption is an important factor to prolong the battery-operated devices' lifetime. Many researches and techniques to reduce the power consumption have been proposed and developed but any power method cannot guarantee optimal power consumption of an embedded device - it would be faced with numerous situation - in all ways. Specifically, power researches for embedded devices deployed in the industry field have hardly been done. In this paper, low power service is proposed to minimize power reduction with the several usage status of embedded devices in the industry field. The usage status is basically classified according to the distance between the device and the user which is obtained by the ultrasonic and PIR sensor. The performance evaluation shows that the proposed scheme can reduce the power consumption by up to 45.3% compared to the device with no power reduction scheme. It also shows that the power consumption of the proposed scheme is 5.2% ~ 16.8% lower than that of the timeout scheme.

저전력 내장형 시스템을 위한 부하의 전력 소모 에뮬레이션 시스템과 응용 (A Load Emulator for Low-power Embedded Systems and Its Application)

  • 김관호;장래혁
    • 전자공학회논문지SC
    • /
    • 제42권6호
    • /
    • pp.37-48
    • /
    • 2005
  • 내장형 시스템의 DC-DC 변환기나 배터리의 효율은 시스템을 구성하는 디바이스들의 종류 및 다양한 동작 패턴에 따른 전류의 시간적인 변화에 영향을 받는다. 이러한 특성은 DC-DC 변환기나 배터리의 효율을 분석하기 위해서는 다양한 부하를 가지는 실제 시스템을 구현, 응용프로그램을 수행하고, 배터리와 DC-DC 변환기를 포함한 전원 공급 회로를 연결하여 실제로 전력 소모를 측정할 것을 요구하지만, 이와 같이 실제 시스템을 구현한다는 것은 엄청난 개발 시간과 비용을 요구한다. 본 논문에서는 부하들의 전력 소모를 측정에 의해 얻어 저장하고 전원 공급 회로로부터 실제 시스템의 부하처럼 전력을 소모하도록 에뮬레이션 해줄 수 있는 시스템을 구현하였다. 구현한 부하 에뮬레이터(load emulator)는 측정한 전력 소모 프로파일의 양을 줄이기 위해 패턴 인식 후 압축하는 알고리즘을 사용하며, 저속 대용량 능동부하(active load)와 고속 소용량 능동부하들로 이루어진 비대칭(heterogeneous) 구조로 구현함으로써 전력 소모의 양이 많고 전력 소모가 신속하게 변하는 디지털 시스템의 부하를 에뮬레이션 할 수 있게 해준다. 구현한 부하 에뮬레이터의 성능을 평가하기 위해 하드디스크의 전력 소모를 측정 및 재생하여 비교하며, 부하 에뮬레이터의 응용으로써 부하의 전력 소모 패턴에 따른 DC-DC 변환기의 효율을 검토해 보았다.

불평형 전압 운전시의 역률보상용 커패시터 특성 연구 (A Study on the Characteristics for Power Capacitor under the Voltage Unbalance Operation)

  • 김일중;김종겸
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.36-40
    • /
    • 2008
  • Most of the low-voltage feeder are designed with approximately balanced and connected at the three phase four wire systems. However, Most of the power distribution systems' load which is composed of single or three phase are unbalanced by generating load unbalance. Unbalanced current will draw a highly unbalanced voltage. The power factor of an induction motor at rated operation is between 25 and 90%, depending on the size and speed of the motor. However, many induction motors operate below the nominal rating, resulting in poor power factor. This condition needs power factor improvement. Addition of power capacitor at the motor terminal may draw to stress due to voltage unbalance. This paper presents operation characteristics on steady states of a three-phase induction motor under unbalanced voltages with power capacitor. The existence of voltage unbalance have an effect on stress of power capacitor.

Unity Power Factor Control of Sensorless Switched Reluctance Motor

  • Jeyakumar, A. Ebenezer;Shanmuganandan, K.J.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1147-1152
    • /
    • 2004
  • Switched Reluctance Motors have an inexpensive, intrinsic simplicity and low cost that makes them well suited to home appliance and office applications. However the motor suffering with necessity of shaft position sensor, lead to non-linearity of operations. Further, the involvement of static converters deteriorates the operational power factor. Implementation of a sensorless algorithm, can remove the need of position sensors. Also, the drive includes a compact power factor control in the input stage by implementing Zero Current Switching Quasi-Resonant Boost Technology. This paper presented, aims at optimized low line current distortion, high power factor, low cost and a shaft position sensorless Switched Reluctance Motor drive.

  • PDF

Design and Performance Analysis of Coreless Axial-Flux Permanent-Magnet Generator for Small Wind Turbines

  • Chung, Dae-Won;You, Yong-Min
    • Journal of Magnetics
    • /
    • 제19권3호
    • /
    • pp.273-281
    • /
    • 2014
  • This paper presents an innovative design for a low-speed, direct-drive, axial-flux permanent-magnet (AFPM) generator with a coreless stator and rotor that is intended for application to small wind turbine power generation systems. The performance of the generator is evaluated and optimized by means of comprehensive 3D electromagnetic finite element analysis. The main focus of this study is to improve the power output and efficiency of wind power generation by investigating the electromagnetic and structural features of a coreless AFPM generator. The design is validated by comparing the performance achieved with a prototype. The results of our comparison demonstrate that the proposed generator has a number of advantages such as a simpler structure, higher efficiency over a wide range of operating speeds, higher energy yield, lighter weight and better power utilization than conventional machines. It would be possible to manufacture low-cost, axial-flux permanent-magnet generators by further developing the proposed design.

Tritium( $^3$H) Activity Measurement by the Liquid Scintillation Counting Method

  • Hwang, Sun-Tae;Oh, Pil-Jae;Lee, Min-Kie;Kim, Wi-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제10권E호
    • /
    • pp.299-302
    • /
    • 1994
  • At a nuclear power plant, environmental radioactivity monitoring is routine work for the radiation safety management For the environmental monitoring of tritium($^3$H) activity in water sampled liquid scintillation counting( LSC) method is applied to measure low- energy beta activity from tritium in the samples. The $^3$H activity is measured using the BECKMAN 5801 system at the KRISS( Korea Research Institute of Standards and Science) for evaluating the lower limits of detection( LLD) of $^3$H measurement and the measuring capability of low-level $^3$H activity at four nuclear Power Plant sites. The LSC systems used for low-level $^3$H activity measurements at the nuclear Power Plants are confirmed to satisfy throughout an intercomparison study under the experimental arrangements by the KRISS.

  • PDF

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev Oleg;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.89-92
    • /
    • 2001
  • Silent gas discharge method has been widely applied for ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low-cost power supply for such systems is a task of great impotency. This paper introduces high-frequency inverter type mode power supply designed for ozone generation tube and ultraviolet generation excimer lamp and considerations on this inverter and pulse density modulation control strategy applied in it.

  • PDF

Load Flow Calculation and Short Circuit Faults Transients in Dispersed Generation Systems

  • Hosseini, Seyed Hossein;Shahnia, Farhad;Tizghadam, Saeed
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.800-804
    • /
    • 2005
  • Load flow and short circuit fault transients of a power distribution system with wind turbines as dispersed generation units is presented. Usage of renewable energies such as wind is already a small part of total installed power system in medium and low voltage networks. In this paper, a radial power distribution system with wind turbines is simulated using DIgSILENT PowerFactory software for their influence on load flow and short circuit fault transients. Short fault occurring in dispersed generation systems causes some problems for the system and costumers such as fault level increase or the problems of sudden fluctuations in the current, voltage, power and torque of the double fed induction machine utilized in the wind turbines which have been studied and investigated.

  • PDF