• Title/Summary/Keyword: Low mode volume

Search Result 87, Processing Time 0.032 seconds

Dielectric and Piezoelectric of Ceramic-Polymer Composite with Ceramic Particle Size (세라믹 분말 크기가 압전 세라믹-폴리머 복합체의 유전 및 압전 특성에 미치는 영향)

  • 이형규;김호기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1989.06a
    • /
    • pp.63-65
    • /
    • 1989
  • Piezoelectric BaTiO$_3$-polymer composite were investigated for dielectric and piezoelectric properties with the barium titanate active particle size. Under the condition of the same density and ceramic volume ratio of composite, the dielectric and piezoelectric constant of composite are increasing as the ceramic particle size in composite are increasing. The surface layer model was quoted to explain these phenomena in our system and experimentally confirmed. The connectivity parameter of modified cube model of composite was calculated from the dielectric constant variation as their particle size. The connectivity parameter X and Y were 77.8% and 98.9% respectively. It means that the barium titanate particle distribution in composite nearly approach to the parallel mode. It was experimentally confirmed that the surface layer has low dielectric and nonferroelectric properties. Dielectric constant and thickness of surface layer were calculated from the equivalent circuit of composite.

  • PDF

Implementation of Waveguide Manifold Multiplexer for Ku-band Satellite Transponder (Ku-대역 위성중계기용 도파관 Manifold 멀티플렉서 설계)

  • 정근욱;이재현
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.6
    • /
    • pp.787-798
    • /
    • 1995
  • We implement the E-plane T-juncition manifold mutiplexer having low insertion loss for output multiplexer of Ku-band satellite transponder. Manifold multiplexer implemented here is composed of 2 channel filters, T-junctions, half-wave waveguide connecting channel filters and manifold, and manifold itself.[1-4] Considering the mass and volume of the satellite transponder, the channel filters are designed to dual-mode.[5-13] And Elliptic filter function is used, which has good characteristics of suppressing the interference between 2 channels. Since the performance of manifold multiplexer depends on the manifold waveguide transmission line length, it's necessary proper analysis. In this paper, we do optimization process of T-junction and other elements by using CAD and implement the manifold multiplexer. An experiment shows that characteristic response of multiplexer matches wel its modeling result.

  • PDF

A Study on the Development of SFF System based on 3DP Process (3차원 프린팅(3DP) 공정을 기반으로 한 임의형상제작(SFF) 시스템 개발에 관한 연구)

  • Lee Won-Hee;Kim Jung-Su;Lee Min-Cheol;Kim Dong-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.7 s.184
    • /
    • pp.168-176
    • /
    • 2006
  • Nowadays, Three dimensional printing (3DP) technique that is one of solid freeform fabrication (SFF) technology has been notable issue, and has been applied by various fields. The SFF system can fabricate three dimensional objects of solid freeform with high speed and low cost using ink jet printing technology. In this research, a SFF system to analyze 3DP process technology is developed. We applied sliding mode control with sliding perturbation observer (SMCSPO) algorithm and minimized position error to the developed SFF system. We analyzed and optimized process variables such as jetted volume, layer thickness, powder bed and so on experimentally. Also. the dimensional error of a developed SFF system is evaluated. Finally, the feasibility of application to bio manufacturing is presented through successful fabrication of teeth and cranium model.

Experimental Investigation of a Regression rate On Hybrid Rocket Engine

  • Park, J. W.;S. Krishnan;Lee, C. W.;M. W. Yoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.524-527
    • /
    • 2004
  • Hybrid rocket had many advantage with compared to solid and liquid rockets. However, the engines have not yet been used in practical rocket systems, due mainly to the disadvantage of hybrid combustion, such as low fuel regression rate. In this study, lab-scale hybrid motor was designed and manufactured. And the methods of regression rate improvement were considered. Test firings with thrusts up to 300 N were conducted with GOX and transparent PMMA. Thrust was calculated with the pressure of the combustion chamber and the regression rate was measured in with variation of oxidizer flow rate. The regression rates showed a strong dependency on GOX mass flux. The frequency analysis technique of the bulk-mode oscillation of motor was applied to a hybrid rocket motor and was based on the principle that this frequency was inversely proportional to the square root of the chamber volume. Several problems and solutions of operating hybrid rocket were presented.

  • PDF

TASK-1 Channel Promotes Hydrogen Peroxide Induced Apoptosis

  • Yun, Ji-Hyun;Kim, Seung-Tae;Bang, Hyo-Weon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.9 no.1
    • /
    • pp.63-68
    • /
    • 2005
  • Hydrogen peroxide ($H_2O_2$) causes oxidative stress and is considered as an inducer of cell death in various tissues. Two-pore domain $K^+$ ($K_{2p}$) channels may mediate $K^+$ efflux during apoptotic volume decreases (AVD) in zygotes and in mouse embryos. In the present study, we sought to elucidate linkage between $K_{2p}$ channels and cell death by $H_2O_2$. Thus $K_{2p}$ channels (TASK-1, TASK-3, TREK-1, TREK-2) were stably transfected in HEK-293 cells, and cytotoxicity assay was preformed using cell counting kit-8 (CCK-8). Cell survival rates were calculated using the cytotoxicity assay data and dose-response curve was fitted to the $H_2O_2$ concentration. Ionic currents were recorded in cell-attached mode. The bath solution was the normal Ringer solution and the pipette solution was high $K^+$ solution. In HEK-293 cells expressing TREK-1, TREK-2, TASK-3, $H_2O_2$ induced cell death did not change in comparison to non-transfected HEK-293. In HEK-293 cells expressing TASK-1, however, dose-response curve was significantly shifted to the left. It means that $H_2O_2$ induced cell death was increased. In cell attached-mode recording, application of $H_2O_2$ (300μM) increased activity of all $K_{2p}$ channels. However, a low concentration of $H_2O_2$ ($50{\mu}M$) increased only TASK-1 channel activity. These results indicate that TASK-1 might participate in $K^+$ efflux by $H_2O_2$ at low concentration, thereby inducing AVD.

BETTER UNDERSTANDING OF THE BIOLOGICAL EFFECTS OF RADIATION BY MICROSCOPIC APPROACHES

  • Kim, Eun-Hee
    • Nuclear Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.551-560
    • /
    • 2008
  • Radiation has stochastic aspects in its generation, its choice of interaction mode during traveling in media, and its impact on living bodies. In certain circumstances, like in high dose environments resulting from low-LET radiation, the variance in its impact on a target volume is negligible. On the contrary, in low dose environments, especially when they are attributed to high-LET radiation, the impact on the target carries with it a large variance. This variation is more significant for smaller target volumes. Microdosimetric techniques, which have been developed to estimate the distribution of radiation energy deposited to cellular and subcellular-sized targets, contrast with macrodosimetric techniques which count only the average value. Since cells and DNA compounds are the critical targets in human bodies, microdosimetry, or dose estimation by microscopic approach, helps one better analyze the biological effects of radiation on the human body. By utilizing microbeam systems designed for individual cell irradiation, scientists have discovered that human cells exhibit radiosensitive reactions without being hit themselves (bystander effect). During the past 10 or more years, a new therapeutic protocol using discontinuous multiple micro-slit beams has been investigated for its clinical application. It has been suggested that the beneficial bystander effect is the essence of this protocol.

Dual-Output Single-Stage Bridgeless SEPIC with Power Factor Correction

  • Shen, Chih-Lung;Yang, Shih-Hsueh
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.309-318
    • /
    • 2015
  • This study proposes a dual-output single-stage bridgeless single-ended primary-inductor converter (DOSSBS) that can completely remove the front-end full-bridge alternating current-direct current rectifier to accomplish power factor correction for universal line input. Without the need for bridge diodes, the proposed converter has the advantages of low component count and simple structure, and can thus significantly reduce power loss. DOSSBS has two uncommon output ports to provide different voltage levels to loads, instead of using two separate power factor correctors or multi-stage configurations in a single stage. Therefore, this proposed converter is cost-effective and compact. A magnetically coupled inductor is introduced in DOSSBS to replace two separate inductors to decrease volume and cost. Energy stored in the leakage inductance of the coupled inductor can be completely recycled. In each line cycle, the two active switches in DOSSBS are operated in either high-frequency pulse-width modulation pattern or low-frequency rectifying mode for switching loss reduction. A prototype for dealing with an $85-265V_{rms}$ universal line is designed, analyzed, and built. Practical measurements demonstrate the feasibility and functionality of the proposed converter.

SND in Fludized Media Aerobic Tank of Membrane-BNR Process (Membrane-BNR 공정의 유동상 담체 호기조내 SND 평가)

  • Lee, Jung-Yeol;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.2
    • /
    • pp.322-328
    • /
    • 2009
  • The advantage of simultaneous nitrification and denitrification (SND) is to reduce requirement of oxygen as well as tank volume. The fludized media was used in the oxic (aerobic) tank of Membrane-BNR to enhance the efficiency of SND. Nowadays, the interest of applying membrane to the wastewater treatment plant has been increased, which is proved by a lot of research published about the MBR. The Membrane-BNR, consisted of total 5 reactors might be called the compact process by using the fludized media and having short HRT of 6.5 hr. It could attain the further removal of not only the organics but also nutrients such as T-N and T-P. The mode A and B were identified with or without the step feed of influent. The mode A was classified with 3 modes according to the different DO concentration in the fludized media aerobic reactor, and the mode B with step feed was operated with the optimum DO condition. The step-feed was capable of improving TN removal efficiency under the domestic wastewater with the low ratio C/N. On the other hand, the efficiency of SND with the 1.0~1.5 mg/L DO in the oxic media tank was better than the one with below 1.0 mg/L, on which the nitrification did not happen enough, and with above 3.5 mg/L, on which the reduction of anoxic area in the tank happened. It means that the profitable nitrification should be performed prior to the denitrification step. The removal efficiency of nitrogen by SND was about 20% among of total denitrified nitrogen. And some organic carbon consumed could be reduced by the endogeneous denitrification.

Low frequency Instability in Hybrid Rocket Post-chamber Configuration (연소실 형상 변화에 의한 하이브리드 로켓의 저주파수 연소불안정)

  • Park, Kyungsu;Lee, Changjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.1
    • /
    • pp.29-36
    • /
    • 2014
  • Hybrid rocket displays many different low frequency pressure oscillations during combustion. Thermal lag between solid and gas phase is the primary mechanism to trigger low frequency pressure oscillations of around 10Hz, and Helmholtz or $L^*$ mode also produces other types of low frequency oscillations above 10 Hz which is associated with the change in combustion volume. Since the flow characteristics in hybrid rocket is very similar to those in solid rocket combustion, it is not surprising to observe similar pressure oscillation behaviors. Experimental test shows that combustion pressure suddenly turns into to a big amplitude oscillation around 10Hz then followed by returning to an original pressure level after a short period combustion. Further investigations show that this instability is independent of the change in O/F ratio at all. One of the possible candidates is the vortex shedding dynamics over the backward step in the post combustion chamber. It is required to investigate the low frequency oscillation mechanism in the future study.

Numerical Analysis on the Increasing Temperature Characteristics of Vaporizer Fin for Liquefied Natural Gas with Super Low Temperature (초저온 액화 천연 가스용 기화기 핀의 승온 특성에 관한 수치 해석)

  • Yi, C.S.;Kong, T.W.;Lee, H.D.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.9 no.2
    • /
    • pp.81-87
    • /
    • 2005
  • This study is numerical analysis on the increasing temperature characteristics of vaporizer fin for liquefied natural gas with super low temperature. Existing LNG vaporizers use the direct contact heat transfer mode where the extreme super low temperature LNG of $-162^{\circ}C$ flows inside of the tubes and about $20^{\circ}C$air flows on outside of the fin. Recently, the vaporizers with great enhanced performance compared to conventional type have been developed to fulfill these requirements. The vaporizing characteristic of LNG vaporizer with air as heat source has a fixed iced. These characteristic cause a low efficiency in vaporizer, total plant cost and installing space can be increased. The vaporizing characteristics of LNG via heat exchanger with air are analytically studied for an air heating type vaporizer. This study is intended to supply the design data for the domestic fabrication of the thickness and angle vaporizer fin. Governing conservation equations for mass, momentum and energy are solved by STAR-CD based on an finite volume method and SIMPLE algorithm. Calculation parameter is fin thickness, setup angle and LNG temperature. If the vaporization performance of the early stage and late stage of operating is considered, the case of ${\phi}=90^{\circ}$ was very suitable. In this paper was estimated that the heat transfer was most promoted in case of THF=2mm.

  • PDF