• 제목/요약/키워드: Low mode volume

검색결과 87건 처리시간 0.039초

세라믹 분말 크기가 압전 세라믹-폴리머 복합체의 유전 및 압전 특성에 미치는 영향 (Dielectric and Piezoelectric of Ceramic-Polymer Composite with Ceramic Particle Size)

  • 이형규;김호기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1989년도 춘계학술대회 논문집
    • /
    • pp.63-65
    • /
    • 1989
  • Piezoelectric BaTiO$_3$-polymer composite were investigated for dielectric and piezoelectric properties with the barium titanate active particle size. Under the condition of the same density and ceramic volume ratio of composite, the dielectric and piezoelectric constant of composite are increasing as the ceramic particle size in composite are increasing. The surface layer model was quoted to explain these phenomena in our system and experimentally confirmed. The connectivity parameter of modified cube model of composite was calculated from the dielectric constant variation as their particle size. The connectivity parameter X and Y were 77.8% and 98.9% respectively. It means that the barium titanate particle distribution in composite nearly approach to the parallel mode. It was experimentally confirmed that the surface layer has low dielectric and nonferroelectric properties. Dielectric constant and thickness of surface layer were calculated from the equivalent circuit of composite.

  • PDF

Ku-대역 위성중계기용 도파관 Manifold 멀티플렉서 설계 (Implementation of Waveguide Manifold Multiplexer for Ku-band Satellite Transponder)

  • 정근욱;이재현
    • 전자공학회논문지A
    • /
    • 제32A권6호
    • /
    • pp.787-798
    • /
    • 1995
  • We implement the E-plane T-juncition manifold mutiplexer having low insertion loss for output multiplexer of Ku-band satellite transponder. Manifold multiplexer implemented here is composed of 2 channel filters, T-junctions, half-wave waveguide connecting channel filters and manifold, and manifold itself.[1-4] Considering the mass and volume of the satellite transponder, the channel filters are designed to dual-mode.[5-13] And Elliptic filter function is used, which has good characteristics of suppressing the interference between 2 channels. Since the performance of manifold multiplexer depends on the manifold waveguide transmission line length, it's necessary proper analysis. In this paper, we do optimization process of T-junction and other elements by using CAD and implement the manifold multiplexer. An experiment shows that characteristic response of multiplexer matches wel its modeling result.

  • PDF

3차원 프린팅(3DP) 공정을 기반으로 한 임의형상제작(SFF) 시스템 개발에 관한 연구 (A Study on the Development of SFF System based on 3DP Process)

  • 이원희;김정수;이민철;김동수
    • 한국정밀공학회지
    • /
    • 제23권7호
    • /
    • pp.168-176
    • /
    • 2006
  • Nowadays, Three dimensional printing (3DP) technique that is one of solid freeform fabrication (SFF) technology has been notable issue, and has been applied by various fields. The SFF system can fabricate three dimensional objects of solid freeform with high speed and low cost using ink jet printing technology. In this research, a SFF system to analyze 3DP process technology is developed. We applied sliding mode control with sliding perturbation observer (SMCSPO) algorithm and minimized position error to the developed SFF system. We analyzed and optimized process variables such as jetted volume, layer thickness, powder bed and so on experimentally. Also. the dimensional error of a developed SFF system is evaluated. Finally, the feasibility of application to bio manufacturing is presented through successful fabrication of teeth and cranium model.

Experimental Investigation of a Regression rate On Hybrid Rocket Engine

  • Park, J. W.;S. Krishnan;Lee, C. W.;M. W. Yoon
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.524-527
    • /
    • 2004
  • Hybrid rocket had many advantage with compared to solid and liquid rockets. However, the engines have not yet been used in practical rocket systems, due mainly to the disadvantage of hybrid combustion, such as low fuel regression rate. In this study, lab-scale hybrid motor was designed and manufactured. And the methods of regression rate improvement were considered. Test firings with thrusts up to 300 N were conducted with GOX and transparent PMMA. Thrust was calculated with the pressure of the combustion chamber and the regression rate was measured in with variation of oxidizer flow rate. The regression rates showed a strong dependency on GOX mass flux. The frequency analysis technique of the bulk-mode oscillation of motor was applied to a hybrid rocket motor and was based on the principle that this frequency was inversely proportional to the square root of the chamber volume. Several problems and solutions of operating hybrid rocket were presented.

  • PDF

TASK-1 Channel Promotes Hydrogen Peroxide Induced Apoptosis

  • Yun, Ji-Hyun;Kim, Seung-Tae;Bang, Hyo-Weon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제9권1호
    • /
    • pp.63-68
    • /
    • 2005
  • Hydrogen peroxide ($H_2O_2$) causes oxidative stress and is considered as an inducer of cell death in various tissues. Two-pore domain $K^+$ ($K_{2p}$) channels may mediate $K^+$ efflux during apoptotic volume decreases (AVD) in zygotes and in mouse embryos. In the present study, we sought to elucidate linkage between $K_{2p}$ channels and cell death by $H_2O_2$. Thus $K_{2p}$ channels (TASK-1, TASK-3, TREK-1, TREK-2) were stably transfected in HEK-293 cells, and cytotoxicity assay was preformed using cell counting kit-8 (CCK-8). Cell survival rates were calculated using the cytotoxicity assay data and dose-response curve was fitted to the $H_2O_2$ concentration. Ionic currents were recorded in cell-attached mode. The bath solution was the normal Ringer solution and the pipette solution was high $K^+$ solution. In HEK-293 cells expressing TREK-1, TREK-2, TASK-3, $H_2O_2$ induced cell death did not change in comparison to non-transfected HEK-293. In HEK-293 cells expressing TASK-1, however, dose-response curve was significantly shifted to the left. It means that $H_2O_2$ induced cell death was increased. In cell attached-mode recording, application of $H_2O_2$ (300μM) increased activity of all $K_{2p}$ channels. However, a low concentration of $H_2O_2$ ($50{\mu}M$) increased only TASK-1 channel activity. These results indicate that TASK-1 might participate in $K^+$ efflux by $H_2O_2$ at low concentration, thereby inducing AVD.

BETTER UNDERSTANDING OF THE BIOLOGICAL EFFECTS OF RADIATION BY MICROSCOPIC APPROACHES

  • Kim, Eun-Hee
    • Nuclear Engineering and Technology
    • /
    • 제40권7호
    • /
    • pp.551-560
    • /
    • 2008
  • Radiation has stochastic aspects in its generation, its choice of interaction mode during traveling in media, and its impact on living bodies. In certain circumstances, like in high dose environments resulting from low-LET radiation, the variance in its impact on a target volume is negligible. On the contrary, in low dose environments, especially when they are attributed to high-LET radiation, the impact on the target carries with it a large variance. This variation is more significant for smaller target volumes. Microdosimetric techniques, which have been developed to estimate the distribution of radiation energy deposited to cellular and subcellular-sized targets, contrast with macrodosimetric techniques which count only the average value. Since cells and DNA compounds are the critical targets in human bodies, microdosimetry, or dose estimation by microscopic approach, helps one better analyze the biological effects of radiation on the human body. By utilizing microbeam systems designed for individual cell irradiation, scientists have discovered that human cells exhibit radiosensitive reactions without being hit themselves (bystander effect). During the past 10 or more years, a new therapeutic protocol using discontinuous multiple micro-slit beams has been investigated for its clinical application. It has been suggested that the beneficial bystander effect is the essence of this protocol.

Dual-Output Single-Stage Bridgeless SEPIC with Power Factor Correction

  • Shen, Chih-Lung;Yang, Shih-Hsueh
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.309-318
    • /
    • 2015
  • This study proposes a dual-output single-stage bridgeless single-ended primary-inductor converter (DOSSBS) that can completely remove the front-end full-bridge alternating current-direct current rectifier to accomplish power factor correction for universal line input. Without the need for bridge diodes, the proposed converter has the advantages of low component count and simple structure, and can thus significantly reduce power loss. DOSSBS has two uncommon output ports to provide different voltage levels to loads, instead of using two separate power factor correctors or multi-stage configurations in a single stage. Therefore, this proposed converter is cost-effective and compact. A magnetically coupled inductor is introduced in DOSSBS to replace two separate inductors to decrease volume and cost. Energy stored in the leakage inductance of the coupled inductor can be completely recycled. In each line cycle, the two active switches in DOSSBS are operated in either high-frequency pulse-width modulation pattern or low-frequency rectifying mode for switching loss reduction. A prototype for dealing with an $85-265V_{rms}$ universal line is designed, analyzed, and built. Practical measurements demonstrate the feasibility and functionality of the proposed converter.

Membrane-BNR 공정의 유동상 담체 호기조내 SND 평가 (SND in Fludized Media Aerobic Tank of Membrane-BNR Process)

  • 이정열;민경석
    • 한국물환경학회지
    • /
    • 제25권2호
    • /
    • pp.322-328
    • /
    • 2009
  • The advantage of simultaneous nitrification and denitrification (SND) is to reduce requirement of oxygen as well as tank volume. The fludized media was used in the oxic (aerobic) tank of Membrane-BNR to enhance the efficiency of SND. Nowadays, the interest of applying membrane to the wastewater treatment plant has been increased, which is proved by a lot of research published about the MBR. The Membrane-BNR, consisted of total 5 reactors might be called the compact process by using the fludized media and having short HRT of 6.5 hr. It could attain the further removal of not only the organics but also nutrients such as T-N and T-P. The mode A and B were identified with or without the step feed of influent. The mode A was classified with 3 modes according to the different DO concentration in the fludized media aerobic reactor, and the mode B with step feed was operated with the optimum DO condition. The step-feed was capable of improving TN removal efficiency under the domestic wastewater with the low ratio C/N. On the other hand, the efficiency of SND with the 1.0~1.5 mg/L DO in the oxic media tank was better than the one with below 1.0 mg/L, on which the nitrification did not happen enough, and with above 3.5 mg/L, on which the reduction of anoxic area in the tank happened. It means that the profitable nitrification should be performed prior to the denitrification step. The removal efficiency of nitrogen by SND was about 20% among of total denitrified nitrogen. And some organic carbon consumed could be reduced by the endogeneous denitrification.

연소실 형상 변화에 의한 하이브리드 로켓의 저주파수 연소불안정 (Low frequency Instability in Hybrid Rocket Post-chamber Configuration)

  • 박경수;이창진
    • 한국항공우주학회지
    • /
    • 제42권1호
    • /
    • pp.29-36
    • /
    • 2014
  • 하이브리드 로켓 연소에서는 다양한 종류의 저주파수 연소 압력진동이 나타난다. 10Hz 대역의 저주파수 압력진동은 고체연료와 연소가스의 열 관성 차이 때문에 발생하지만 그외의 저주파수 진동은 고체로켓에서 관찰되는 헬름홀츠 및 $L^*$ 모드에 의해 발생하는 것으로 연소실 부피 변화와 밀접한 관련이 있다. 따라서 유동 특성이 고체로켓과 유사한 하이브리드 로켓 연소에서 연소실 부피 변화는 저주파수 특성에 영향을 미치는 중요한 인자이다. 본 연구에서는 연소실과 후연소실의 형상 변화에 따른 연소 압력의 저주파수 특성 변화를 관찰하였다. 특히 주 연소실과 후연소실의 부피 비가 특정한 값이 되면 연소 도중에 10~30Hz 연소 압력 진동의 진폭이 갑자기 증폭되는 연소불안정 현상이 나타났다. 산화제 유량 조절 및 연료 변경에 의한 O/F 비 변화는 연소 압력의 저주파수 증폭과 무관한 것으로 밝혀졌다. 후연소실로 연소가스가 팽창할 때 발생하는 와류 흘림 현상이 저주파수 불안정 현상과 직접적인 관련 있는 것으로 판단되며 이에 관한 연구가 더 필요하다.

초저온 액화 천연 가스용 기화기 핀의 승온 특성에 관한 수치 해석 (Numerical Analysis on the Increasing Temperature Characteristics of Vaporizer Fin for Liquefied Natural Gas with Super Low Temperature)

  • 이중섭;공태우;이효덕;정효민;정한식
    • 동력기계공학회지
    • /
    • 제9권2호
    • /
    • pp.81-87
    • /
    • 2005
  • This study is numerical analysis on the increasing temperature characteristics of vaporizer fin for liquefied natural gas with super low temperature. Existing LNG vaporizers use the direct contact heat transfer mode where the extreme super low temperature LNG of $-162^{\circ}C$ flows inside of the tubes and about $20^{\circ}C$air flows on outside of the fin. Recently, the vaporizers with great enhanced performance compared to conventional type have been developed to fulfill these requirements. The vaporizing characteristic of LNG vaporizer with air as heat source has a fixed iced. These characteristic cause a low efficiency in vaporizer, total plant cost and installing space can be increased. The vaporizing characteristics of LNG via heat exchanger with air are analytically studied for an air heating type vaporizer. This study is intended to supply the design data for the domestic fabrication of the thickness and angle vaporizer fin. Governing conservation equations for mass, momentum and energy are solved by STAR-CD based on an finite volume method and SIMPLE algorithm. Calculation parameter is fin thickness, setup angle and LNG temperature. If the vaporization performance of the early stage and late stage of operating is considered, the case of ${\phi}=90^{\circ}$ was very suitable. In this paper was estimated that the heat transfer was most promoted in case of THF=2mm.

  • PDF