• 제목/요약/키워드: Low level AC voltage

검색결과 57건 처리시간 0.025초

The Performance of Nafion-Based IPMC Actuators Containing Polypyrrole/Alumina Composite Fillers

  • Lee, Jang-Woo;Kim, Ji-Hye;Chun, Yoon-Soo;Yoo, Young-Tai;Hong, Soon-Man
    • Macromolecular Research
    • /
    • 제17권12호
    • /
    • pp.1032-1038
    • /
    • 2009
  • A polypyrrole (PPy)/alumina composite filler prepared via in-situ polymerization of pyrrole on alumina particles was incorporated into $Nafion^{(R)}$ to improve the performance of ionic polymer-metal composite (IPMC) actuators. The IPMCs with the pristine PPy without alumina support did not show bending displacements superior to that of the bare Nafion-based IPMC, except at a high PPy content of 4 wt%. This result was attributed to the low redox efficiency of the PPy alone in the IPMC and may have also been related to the modulus of the IPMC. However, at the optimized filler contents, the cyclic displacement of the IPMCs bearing the PPy/alumina filler was 2.2 times larger than that of the bare Nafion-based IPMC under an applied AC potential of 3 Vat 1 Hz. Even under a low AC potential of 1.5 V at 1 Hz, the displacement of the PPy/alumina-based IPMCs was a viable level of performance for actuator applications and was 2.7 times higher than that of the conventional Nafion-based IPMC. The generated blocking force was also improved with the PPy/aiumina composite filler. The greatly enhanced performance and the low-voltage-operational characteristic of the IPMCs bearing the PPy/alumina filler were attributed to the synergic effects of the neighboring alumina moiety near the PPy moiety involving electrochemical redox reactions.

Grid-friendly Control Strategy with Dual Primary-Side Series-Connected Winding Transformers

  • Shang, Jing;Nian, Xiaohong;Chen, Tao;Ma, Zhenyu
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.960-969
    • /
    • 2016
  • High-power three-level voltage-source converters are widely utilized in high-performance AC drive systems. In several ultra-power instances, the harmonics on the grid side should be reduced through multiple rectifications. A combined harmonic elimination method that includes a dual primary-side series-connected winding transformer and selective harmonic elimination pulse-width modulation is proposed to eliminate low-order current harmonics on the primary and secondary sides of transformers. Through an analysis of the harmonic influence caused by dead time and DC magnetic bias, a synthetic compensation control strategy is presented to minimize the grid-side harmonics in the dual primary side series-connected winding transformer application. Both simulation and experimental results demonstrate that the proposed control strategy can significantly reduce the converter input current harmonics and eliminates the DC magnetic bias in the transformer.

누설전류 검출 및 차단을 위한 제어알고리즘 설계 (Controller design for Leakage current detection and disconnection)

  • 반기종;윤광호;박진수;남문현;김낙교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.417-420
    • /
    • 2003
  • In this paper, we have designed the ground faults detection and disconnection algorithm at normal rendition of AC 120V to 240V rating voltage. Ground faults in electrical network have the characteristics of low current, 60Hz frequency to 2kHz frequency. The load rendition are no load and 20A load. The controller have the trip level are 6mA with ground faults. Conventional controller does not have the miswiring condition. The Controller algorithm using pic16c71 microprotessor.

  • PDF

Efficient Decoupling Capacitor Optimization for Subsystem Module Package

  • Lim, HoJeong;Fuentes, Ruben
    • 마이크로전자및패키징학회지
    • /
    • 제29권1호
    • /
    • pp.1-6
    • /
    • 2022
  • The mobile device industry demands much higher levels of integration and lower costs coupled with a growing awareness of the complete system's configuration. A subsystem module package is similar to a board-level circuit that integrates a system function in a package beyond a System-in-Package (SiP) design. It is an advanced IC packaging solution to enhance the PDN and achieve a smaller form factor. Unlike a system-level design with a decoupling capacitor, a subsystem module package system needs to redefine the role of the capacitor and its configuration for PDN performance. Specifically, the design of package's form factor should include careful consideration of optimal PDN performance and the number of components, which need to define the decoupling capacitor's value and the placement strategy for a low impedance profile with associated cost benefits. This paper will focus on both the static case that addresses the voltage (IR) drop and AC analysis in the frequency domain with three specific topics. First, it will highlight the role of simulation in the subsystem module design for the PDN. Second, it will compare the performance of double-sided component placement (DSCP) motherboards with the subsystem module package and then prove the advantage of the subsystem module package. Finally, it will introduce three-terminal decoupling capacitor (decap) configurations of capacitor size, count and value for the subsystem module package to determine the optimum performance and package density based on the cost-effective model.

지하철 운행 중 발생하는 객차 내부 극저주파 자기장(ELF-MF) 세기 평가 (Evaluation of Intensity of Extremely Low Frequency Magnetic Fields (ELF-MF) Inside of Cabins as Generated During Subway Operation)

  • 이지현;강명지;박윤경;박동욱;최상준
    • 한국산업보건학회지
    • /
    • 제29권2호
    • /
    • pp.185-194
    • /
    • 2019
  • Objective: This study was conducted to investigate the intensity of the extremely low frequency magnetic fields(ELF-MF) generated inside of the cabins during subway operation. Methods: The ELF-MF intensity were investigated on 30 subway lines in Korea, including in the Greater Seoul Metropolitan Area(Seoul and Gyeonggi-do Province), Incheon, Busan, Daegu, Daejeon, and Gwangju. ELF-MF intensity was measured at 0.9 m from the floor using EMDEX II meters with a resolution of $0.01{\mu}T$. All data were collected every three seconds and analyzed with EMCALC 2013 version 3.0B software. Basic characteristics of subway operation, including alternative current(AC) or direct current(DC), voltage level, and opening year of the line were investigated. Real-time information during measurement, such as the time of departure, moving and arrival of trains, were also recorded. Results: The arithmetic mean(AM) and maximum(Max) intensity of ELF-MF were $0.62{\mu}T$ and $11.51{\mu}T$, respectively. Compared by region, the ELF-MF intensity measured inside cabin were the highest in the Seoul Metropolitan Area($AM=0.80{\mu}T$), followed by Busan($AM=0.30{\mu}T$), Daegu($AM=0.29{\mu}T$), Incheon($AM=0.14{\mu}T$), Gwangju($AM=0.04{\mu}T$) and Daejeon($AM=0.03{\mu}T$). The average ELF-MF level measured in AC trains($AM=1.36{\mu}T$) was also significantly higher than in DC trains($AM=0.28{\mu}T$). In terms of the opening year of the subway, trains opened before 1990($AM=0.85{\mu}T$) was the highest and the lowest was 2000-2009($AM=0.24{\mu}T$). Conclusions: The AC supply has the greatest influence on the generation of the ELF-MF intensity in subway cabins.

Stability and Performance Investigations of Model Predictive Controlled Active-Front-End (AFE) Rectifiers for Energy Storage Systems

  • Akter, Md. Parvez;Mekhilef, Saad;Tan, Nadia Mei Lin;Akagi, Hirofumi
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.202-215
    • /
    • 2015
  • This paper investigates the stability and performance of model predictive controlled active-front-end (AFE) rectifiers for energy storage systems, which has been increasingly applied in power distribution sectors and in renewable energy sources to ensure an uninterruptable power supply. The model predictive control (MPC) algorithm utilizes the discrete behavior of power converters to determine appropriate switching states by defining a cost function. The stability of the MPC algorithm is analyzed with the discrete z-domain response and the nonlinear simulation model. The results confirms that the control method of the active-front-end (AFE) rectifier is stable, and that is operates with an infinite gain margin and a very fast dynamic response. Moreover, the performance of the MPC controlled AFE rectifier is verified with a 3.0 kW experimental system. This shows that the MPC controlled AFE rectifier operates with a unity power factor, an acceptable THD (4.0 %) level for the input current and a very low DC voltage ripple. Finally, an efficiency comparison is performed between the MPC and the VOC-based PWM controllers for AFE rectifiers. This comparison demonstrates the effectiveness of the MPC controller.

병실 냉.난방을 위한 초퍼와 PWM 전압형 인버터를 이용한 계통 연계형 태양광 발전시스템에 관한 연구 (A Study on the Utility Interactive Photovoltaic System Using a Chopper and PWM Voltage Source Inverter for Air Conditioner a Clinic room)

  • 황락훈;나승권
    • 한국산학기술학회논문지
    • /
    • 제9권2호
    • /
    • pp.360-369
    • /
    • 2008
  • 태양전지는 일사량, 온도와 부하에 의해 크게 변동하기 때문에 가능한 한 많은 에너지를 얻기 위해서는 태양전지의 출력을 항상 최대로 제어할 필요가 있다. 태양전지의 출력은 직류이므로 교류부하에 적용하기 위해서는 전력변환장치 중 인버터가 필수적이며 단위 역률을 갖는 정현파 전류 및 전압을 부하계통에 공급해 주어야 한다. 본 논문에서는 태양광 발전시스템을 승압 쵸퍼와 단상 PWM(Pulse Width Modultion) 전압형 인버터로 구성하였고, 안정된 변조를 위해서 동기신호와 제어신호를 원칩 마이크로프로세서에 의해서 처리하였다. 전력비교에 따라 시비율을 변화시키지만 태양전지는 전형적인 수하특성을 갖고 있어, 일사량과 온도변화에 관계없이 항상 최대 출력 점을 추적하도록 승압초퍼를 제어하였다. 단상 PWM 전압형 인버터는 태양전지가 연속 발전할 수 없는 단점을 보완하기 위해 일반 상용전원과 연계함으로써 약 $10{\sim}20%$ 전력절감효과를 얻을 수 있는 에너지절약 전원복합형 전력변환장치로 구성되어 있다. 단상 PWM 전압형 인버터와 위상동기를 위해서 계통전압을 검출하여 계통전압과 인버터 출력을 동상 운전하므로 잉여전력을 계통과 연계할 수 있게 하여 고 역률과 저고조파 출력을 유지 하므로써 부하와 계통에 전력이 안정하게 공급될 수 있도록 제어하였다.