• 제목/요약/키워드: Low dose CT

검색결과 204건 처리시간 0.026초

Comprehensive Updates in the Role of Imaging for Multiple Myeloma Management Based on Recent International Guidelines

  • Koeun Lee;Kyung Won Kim;Yousun Ko;Ho Young Park;Eun Jin Chae;Jeong Hyun Lee;Jin-Sook Ryu;Hye Won Chung
    • Korean Journal of Radiology
    • /
    • 제22권9호
    • /
    • pp.1497-1513
    • /
    • 2021
  • The diagnostic and treatment methods of multiple myeloma (MM) have been rapidly evolving owing to advances in imaging techniques and new therapeutic agents. Imaging has begun to play an important role in the management of MM, and international guidelines are frequently updated. Since the publication of 2015 International Myeloma Working Group (IMWG) criteria for the diagnosis of MM, whole-body magnetic resonance imaging (MRI) or low-dose whole-body computed tomography (CT) and 18F-fluorodeoxyglucose positron emission tomography/CT have entered the mainstream as diagnostic and treatment response assessment tools. The 2019 IMWG guidelines also provide imaging recommendations for various clinical settings. Accordingly, radiologists have become a key component of MM management. In this review, we provide an overview of updates in the MM field with an emphasis on imaging modalities.

반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험 (Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols)

  • 하성민;정성희;장혁재;박은아;심학준
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.28-35
    • /
    • 2015
  • 본 논문에서는 반복적 구성 기법과 관전류 노출자동조절 기법이 영상의 화질과 방사선량에 미치는 영향을 관상동맥 전산화단층촬영 혈관조영 영상(coronary computed tomography angiography, CCTA)을 대상으로 팬텀 실험에 기반하여 평가하고자 한다. 이를 위하여 미국 의학물리학회(American Association of Physics in Medicine) 표준의 성능 평가 팬텀을 320 다중검출열 CT로써 촬영하였다. 80 kVp, 100 kVp, 120 kVp의 관전압에 있어서, 관전류 노출자동조절 기법은 저선량 목표 표준편차(SD=44)와 고선량(목표 표준편차=33)의 두 가지 설정으로써 촬영하였다. 재구성 변수로서는 필터보정 역투영(FBP)와 반복적 재구성 방법을 설정하여, 전부 12개의 재구성 영상을 획득하였다(12=3 (80, 100, 120 kVp)${\times}2$ (저선량(목표SD=44), 고선량(목표SD=33))${\times}2$ (필터보정역투영, 반복적 재구성). 영상의 화질은 잡음의 세기(표준편차), 변조전달함수, 대조대잡음비(CNR)에 의하여 평가하였으며, 관전압과 관전류 노출자동조절 기법에서의 목표 선량과 대소 및 재구성 기법의 선택이 화질과 방사선량에 미치는 영향을 관찰하였다. 반복적 재구성 기법은 필터보정역투영 기법보다 영상 잡음을 대폭 감소시켰으며 이는 저선량의 경우 더욱 뚜렷하였다. 즉, 잡음의 세기는 관전류 노출자동조절의 설정이 고선량 (목표SD=33)과 저선량(목표SD=44)인 경우, 각각 평균 38%와 평균 46% 감소하였다. 반복적 재구성 기법에 의하여, 변조전달 함수에 의한 공간적 해상도의 평가에 있어서 미약한 감소를 보였으나, 이로써 잡음 저감과 대조대잡음비(CNR)에 있어서의 현저한 개선을 상쇄할 정도의 영향에는 미치지 못 하였다. 결과적으로, 관상동맥 전산화단층촬영 혈관조영 영상의 획득에서 있어서, 반복적 재구성 기법과 관전류 노출자동조정 기법을 동시에 사용하는 것은 영상의 화질을 개선하면서 공간적 해상도의 저하 등 그 부작용은 최소화함으로써, 합리적으로 획득 가능한 한 최소한의 선량 (ALARA)의 원칙에 충실한 실제 임상적 효과를 의미한다고 기대할 수 있다.

임상가를 위한 특집 4 - CBCT 검사법의 정도관리 및 선량 (Radiation Doses and Quality Assurance in Cone Beam CT(CBCT))

  • 최용석;김규태;황의환
    • 대한치과의사협회지
    • /
    • 제52권3호
    • /
    • pp.153-163
    • /
    • 2014
  • 3-dimensional information for anatomic stucture plays a role as integral part in clinical aspect of dental practice. CBCT(cone beam computed tomography) has been accepted as useful diagnostic tool offering Volume data and images for evaluating teeth and jaws in lower radiation dose than conventional CT. CBCT equipment is essential for the quality assurance of it to ensure continued satisfactory performance and result of adequate images. Dental practitioner and oral and maxillofacial radiologist should have a responsibility and critical thinking to deliver this technology to patients in a responsible way, so that diaganostic value is maximised and radiation doses kept as low as resonably achievable. CBCT imaging modality should be used only after a review of the patient's health and imaging history and the completion of a thorough clinical examination. Clinical guidelines are systematically developed statements to assist practitioner and patient decisions about appropriate health care for specific clinical circumstances Dental practitioners should prescribe CBCT imaging only when they expect that the diagnostic yield will benefit patient care, enhance patient safety or improve clinical outcomes significantly. Knowledge of patient dose is essential for clinicians who are making the decision regarding the justification of the exposure. There are some limitation in the measurement of patient dose in CBCT for the approval and adaptation of conventinal methodolgy in CT. It is also important to ensure that doses are optimised and in line with any national and international guidelines. The higher radiation doses of CBCT compared with conventional radiography, mean that high standards must be maintained. The Quality Assurance(QA) programme should entail surveys and checks that are performed according to a regular timetable. QA programme should be maintained by staff to ensure adherence to the programme and to raise its importance among staff.

PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석 (A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests)

  • 윤선희;김양중;강영직;박수영;김호신;류형기
    • 핵의학기술
    • /
    • 제19권1호
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF

전산화단층촬영 검사 시 인체에 미치는 방사선피폭선량 분석연구 (Study of radiation exposure on human body using of Computed Tomography)

  • 선종률;유세종
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.193-198
    • /
    • 2015
  • This study analyzed the total number of 19,636 patients and radiation technologists, 11,433 of male and 8,203 of female by examined body parts, age, types of detectors, the using contrast enhancement and working condition of the technologists, regular staffs or rotation-duty staffs, based on the K-DOS program distributed by FDA with the DLP value of diagnostic evaluation. The result shows that the effective radiation dose was 0.7mSv~41.7mSv for each region and male patients had more radiation exposure than females. And the amount of exposure was also affected by the types and the method of detectors. Furthermore, the regular staffs took the role of helping the patient to get reduced amount of radiation exposure than rotation duty-staffs. Computed tomography (CT) use has increased dramatically over the past several decades. In this reason, to support the patients and the workers' health in the field, the hospitals should apply specialized regular working radiation technologist system and manufacturing companies of those CTs should develop low medical radiation exposure devices.

"S" modifier를 이용한 저선량 CT의 폐암 외 중요 소견에 대한 민감도 분석 (Sensitivity Analysis of Critical Findings Other than Lung Cancer in Low-Dose CT Using "S" Modifier)

  • 김현진
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.343-350
    • /
    • 2023
  • 본 연구에서는 2016년 11월부터 폐암 검진 판독 시 판독의 표준화를 위하여 사용되고 있는 Lung-RADS (Lung CT Screening Reporting and Data System)에 기반하여 폐암 이외에 부수적으로 발견되는 "S" modifier 소견들의 종류와 빈도를 분석하고자 하며 이를 통하여 저선량 CT를 통해 얻을 수 있는 폐암 외의 중요 소견들에 대해 살펴보고 저선량 CT의 폐암 외 질환에 대한 유용성을 파악하고자 하였다. 본 연구 결과 전체 1023명의 대상자에서 360건(35.19%)의 "S" modifier 소견이 나타났으며 가장 발생빈도가 높은 질환은 관상동맥 석회화와 폐기종으로 관상동맥 석회화는 145건(14.17%), 폐기종은 138건(13.49%)으로 나타나 다른 소견들에 비해 발견 비율이 매우 높음을 알 수 있다. 또한 흡연 기간과 연관성이 매우 높은 것으로 확인되었는데 관상동맥 석회화의 경우 비흡연자인 A 그룹에서는 발견 비율이 9건(5.73%), 흡연 10년 이내의 B그룹은 23건(11.44%), 흡연 20년 이내의 C 그룹은 39건(13.68%), 흡연 30년 이내의 D그룹은 43건(18.53%), 흡연 30년 이상의 E그룹은 31건(20.94%)로 나타나 흡연력이 증가할수록 관상동맥 석회화의 발생 확률이 증가함을 알 수 있다. 관상동맥 석회화와 폐기종 이외에도 폐렴 및 폐 간질의 이상소견, 종격동 질환도 흡연 기간과의 연관성 분석결과 p<0.05로 나타나 흡연 기간에 영향을 받음을 알 수 있다.

영상유도 및 호흡동조 방사선치료에서의 영상장비에 의한 흡수선량 분석 (Analysis of the Imaging Dose for IGRT/Gated Treatments)

  • 신정석;한영이;주상규;신은혁;홍채선;안용찬
    • Radiation Oncology Journal
    • /
    • 제27권1호
    • /
    • pp.42-48
    • /
    • 2009
  • 목적: 영상유도방사선치료(IGRT)와 호흡동조방사선치료(4DRT)의 도입은 치료계획 및 치료부위 확인에서 환자에게 방사선 조사량을 증가시킬 가능성이 있다. 따라서 IGRT/4DRT용 영상장비와 기존 장비에서 영상선량을 측정 및 비교하였다. 대상 및 방법: IGRT 및 4DRT를 위해 새로이 도입된 4DCT (GE, Ultra Light Speed 16)와 모의치료기(Varian Acuity), 그리고 치료기(Varian IX)에 장착된 kVp (OBI)의 영상장비 및 EPID (aSi 1000)를 대상으로, RANDO 팬톰의 표면 선량을 측정하여 기존의 장비들(single slice CT (GE, Light Speed), 모의치료기(Varian, Ximatron), L-gram (Varian 2100C))과 비교하였다. 측정은 열형광선량계를 이용하여 두뇌부, 눈, 갑상선, 흉부, 복부 및 골반부의 표면에서 측정하였다. 결과: 기존 CT와 비교하여 4DCT모드에서는 흉부와 복부에서 10배 이상의 선량증가를 보였다($1.74{\pm}0.34$ vs $23.23{\pm}3.67$ cGy). Acuity에서의 선량은 모든 측정부위에서 Ximatron보다 감소하였다($0.91{\pm}0.89$ vs $6.77{\pm}3.56$ cGy). EPID는 기존 L-gram 선량의 약 50% ($1.83{\pm}0.36$ vs $3.80{\pm}1.67$ cGy)였다. OBI의 투시영상선량은 $0.97{\pm}0.34$ cGy며, CBCT 선량은 $2.3{\pm}0.67$ cGy였다. 결론: 4DCT가 선량증가의 가장 큰 원인이며, OBI와 CBCT에 의한 선량은 적으나 매번 치료에 적용 시 총 선량 증가에 대한 고려가 필요하다.

PET/CT 검사 시 IRIS (Iterative Reconstruction in Image Space) 적용에 따른 CT 피폭선량 감소와 PET SUV 비교 연구 (The Study of Reducing Radiation Exposure Dose and Comparing SUV According to Applied IRIS (Iterative Reconstruction in Image Space) for PET/CT)

  • 도용호;송호준;이형진;이홍재;김진의
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.29-34
    • /
    • 2012
  • Siemens사의 CT 선량 감소 소프트웨어인 IRIS의 적용을 통하여 CT 선량 감소 시 노이즈 감소 효과와 해상력의 보존 그리고 ACCT에 IRIS 각 kernel의 적용 시 SUV 변화를 확인하는데 목적을 두었다. Biograph mCT 40 slice 스캐너를 이용하여 AAPM CT performance phantom, Anthropomorphic chest phantom을 관전압 120 kVp로 고정하고 100-10 mAs까지 15%감소하여 스캔 후 FBP, IRIS 각 kernel을 적용하여 재구성 하여 영상의 노이즈, 해상력, 영상 평가를 시행하였다. NEMA IEC body phantom을 이용하여 55.5 MBq를 background에 주입하고 열소와 배후 방사의 비를 8:1이 되도록 모형을 제작하였다. 120 kVp, 50 mAs 조건으로 1분, 2분, 3분, 4분 스캔하여 영상을 획득한 후 ACCT에 IRIS 각 kernel을 적용하여 기존 FBP 방식을 적용한 SUV와의 평가를 시행하였다. IRIS의 적용 시 기존 FBP 방식에 비하여 45% 선량을 감소하였음에도 불구하고 해상력 저하 없는 노이즈 감소 효과가 확인 되었으며 SUV 평가 실험에서 IRIS의 I70f kernel을 제외하고는 기존 FBP 방식을 통하여 획득된 SUV와 유의한 차이가 나타나지 않았다. 본 연구를 통하여 IRIS 적용 시 기존 FBP 방식에 비하여 CT 피폭선량 감소와 해상력 저하 없는 노이즈 감소 효과를 입증하였으며 IRIS kernel의 적절한 적용을 통하여 PET/CT 검사 시 환자 피폭선량 감소는 물론 FBP 방식에 비하여 우수한 영상의 획득이 가능할 것이라 사료된다.

  • PDF