• 제목/요약/키워드: Low cost inverter

검색결과 241건 처리시간 0.025초

Design and Implementation of a Low Cost Grid-Connected 5 kVA Photovoltaic System with Load Compensation Capability

  • Mejdar, Reza Seifi;Salimi, Mahdi;Zakipour, Adel
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2306-2314
    • /
    • 2016
  • Design and implementation of a low cost grid-connected 5kVA solar photovoltaic (PV) system is proposed in this paper. Since the inverter is a major component of the PV system, the B4 inverter used in this paper reduces the total cost of the PV system. In order to eliminate the massive transformer, the PV system is connected to the grid through IGBT switches. In addition to injection of active power into the grid, the B4 inverter can compensate reactive power and reduce harmonics of the nonlinear loads. A TMS320F28335 DSP processor is used for effective control of the B4 inverter. Various features of this processor enable the implementation of the necessary control algorithms. As a first step, the PV system is simulated and evaluated in Matlab/Simulink. In the second step, hardware circuits are designed and implemented based on the simulation results. The operation of the PV system has been evaluated under balanced, unbalanced, linear and nonlinear loads which proves its accuracy and efficiency.

고 효율, 저 잡음 특성을 가지는 양방향 태양광 인버터 (Bi-directional Photovoltaic Inverter with High Efficiency and Low Noise)

  • 이성호;권정민;권봉환
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.539-545
    • /
    • 2012
  • Due to merits cost and efficiency, the transformer-less type photovoltaic (PV) inverters have been popularized in the solar market. However, the leakage current flowing through a parasitic capacitor between PV array and ground can cause adverse effect in the transformer-less PV system. In this paper, a bi-directional PV inverter with high efficiency and low noise is proposed for the PV system with an energy storage device. The proposed inverter is a transformer-less type and performs the bi-directional power control between dc sources and grid with high efficiency. In addition, the proposed inverter can suppress the leakage current and obtain low noise characteristic. Finally, 3-kW prototype was implemented to confirm validity of the proposed inverter.

PERFORMANCE EVALUATIONS OF ADVANCED GENERATION IGBTS AND MCT IN SINGLE-ENDED RESONANT INVERTER

  • Ishimaru, N.;Fujita, A.;Hirota, I.;Yamashita, H.;Omori, H.;Nakamizo, Tetsuo;Shirakawa, S.;Nakaoka, Mutsuo.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.851-854
    • /
    • 1998
  • In recent years, a cost-effective voltage-source type single-ended resonant-load inverter using MOS gate power switching devices and its related resonant inverter topologies have been commonly used for induction-heated cooking appliances because of relatively-lowered switching losses, simple circuit topology, low cost, compactness and low harmonic current in utility AC side. This paper present some comparative performance evaluations of IGBTs as sample devices in each generation and MOS controlled Thyristor(MCT) incorporated into the voltage-source type single-ended load resonant inverter for induction-heating rice cookers used for consumer power electronic applications, in which the output power can be regulated on the basis of Frequency Modulation Scheme.

  • PDF

3상 SRM 구동용 4-스위치 인버터 PWM 제어 알고리즘 (Control Algorithm for 4-Switch Inverter of 3-Phase SRM)

  • 윤용호;이병국;원충연
    • 전기학회논문지P
    • /
    • 제58권3호
    • /
    • pp.303-309
    • /
    • 2009
  • Switched Reluctance Motor(SRM) has become popular for industrial application, particularly for low medium drives due to the advantages of SRM over the other ac motors: SRM can be manufactured with low cost because it has a simple structure. But, asymmetric bridge converter that generally is used for driving requires two discrete switching devices and freewheeling diodes per phase, and cause the SRM drives to be complicated and to increase the cost of overall system. Therefore, this paper suggests a new type of 4-switch converter for SRM. 4-switch converter topology is studied to provide a possibility for the realization of low cost 3-phase SRM drive system. For effective utilization of the developed system, a new current control algorithm is designed and implemented to produce the desired dynamic performance. With the developed power conversion circuit and control scheme, it is expected that the proposed system can be widely used in commercial applications with reduced system cost.

사각 고주파 주입을 통한 저가형 인버터의 센서리스 운전 (Sensorless Operation of Low-cost Inverters through Square-wave High Frequency Voltage Injection)

  • 황상진;이동명
    • 전기전자학회논문지
    • /
    • 제26권1호
    • /
    • pp.95-103
    • /
    • 2022
  • 본 논문에서는 저가격 인버터에서의 사각파 주입에 의한 센서리스 기법의 제어 성능을 보인다. 저가격 인버터는 소위 말하는 B4 인버터이다. 이 인버터는 저가격화를 위하여 스위칭 소자를 4개를 사용한 형태이다. 고주파 주입을 통한 센서리스 기법을 B4 인버터에 적용하였으며, 주입 고주파의 주파수는 1kH이다. 본 논문에서는 Matlab/ Simulink를 이용한 B4 인버터를 이용한 영구자석 전동기의 센서리스 시스템 모델을 설명한다. 한편, 본 연구에서는 회전자의 위치 추정을 위한 고주파 전류 성분 검출에 노치 필터를 사용하였으며, 추정된 속도의 리플 저감을 위하여 이차 저역 통과 필터를 사용하였다. 노치 필터에 의해 추출된 전류 파형에 고주파 전압을 곱하여 영구 자석 동기 전동기의 회전자 각도를 추정한다. Simulink 시뮬레이션의 통해 제안하는 기법의 타당성을 보인다.

단상 유도 전동기를 위한 하프브리지 인버터 (Half Bridge Inverter for Single Phase Induction Motor Driving)

  • 이종규;김영삼;원영진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.181-183
    • /
    • 1999
  • This paper is about the design of half-bridge inverter controller with low cost and simple configuration for low power single-phase induction motor driving. The simple controller is composed of MCU and PLD. Also, to limit the overcurrent at initial driving, auxiliary function is added, and stabilizes the system. In order to verify the performance of the proposed methode, we design 500W inverter system, and in result, the response time of the proposed method compared with line voltage driving method is reduced by 200[msec].

  • PDF

태양광 마이크로 인버터를 위한 탭인덕터 부스트 및 강압형 컨버터 캐스케이드 타입 저가형 고효율 전력변환기 (Low-Cost High-Efficiency Two-Stage Cascaded Converter of Step-Down Buck and Tapped-Inductor Boost for Photovoltaic Micro-Inverters)

  • 장종호;신종현;박종후
    • 전력전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.157-163
    • /
    • 2014
  • This paper proposes a two-stage step-down buck and a tapped-inductor boost cascaded converter for high efficiency photovoltaic micro-inverter applications. The proposed inverter is a new structure to inject a rectified sinusoidal current into a low-frequency switching inverter for single-phase grid with unity power factor. To build a rectified-waveform of the output current. the converter employs both of a high efficiency step-up and a step-down converter in cascade. In step-down mode, tapped inductor(TI) boost converter stops and the buck converter operates alone. In boost mode, the TI converter operates with the halt of buck operation. The converter provides a rectified current to low frequency inverter, then the inverter converts the current into a unity power-factor sinusoidal waveform. By applying a TI, the converter can decrease the turn-on ratios of the main switch in TI boost converter even with an extreme step-up operation. The performance validation of the proposed design is confirmed by an experimental results of a 120W hardware prototype.

단일 전류센서를 갖는 저가의 단상 반브릿지 APF (Low-cost Single-Phase HAIf-bridge Active Power Filter with One Current Sensor)

  • 김길동;신정렬;이우동;박현준;김희중
    • 한국철도학회논문집
    • /
    • 제7권3호
    • /
    • pp.173-179
    • /
    • 2004
  • This paper describes a low-cost single-phase active power filter, which consists of a half-bridge PWM inverter with a simple control circuit. In order to verify the performance of proposed active power filter, many computer simulations with EMTP codes and experimental works with a hardware prototype were done. Both results confirm that the proposed active power filter shows excellent performance to eliminate the harmonics generated in the single-phase non-linear load. The active power filter has advantage of low implementation cost and compact size, using a half-bridge inverter and a simple control circuit with only one current sensor. So, it can be fabricated as a plug-in type. This paper shows the necessity and a good possibility to apply such advantage to the electric railway system.

오버샘플된 전류신호를 사용한 인버터 구동형 전동기의 베어링 고장검출 시스템 (High Precison Bearing Fault Detect System of Inverter Driven System Using Oversampled Current Signals)

  • 김남훈;김민회;최창호;이상훈;최경호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.506-508
    • /
    • 2007
  • In this paper, the induction motor bearing fault diagnosis system using current signals which are measured by over-sampling method is presented. In the case of inverter fed motor drive unlike line-driven motor drive, that make a lot of noise which can cause a wrong fault signals because of PWM(pulse width modulation) voltage. So, the current signals for fault diagnosis need very precise and high resolution information, which means this system demand additional hardware such as low pass filter, high resolution ADC system and so on to use fault diagnosis system. Therefore, the proposed over-sampling method is expected to contribute to low cost fault diagnosis system even though previous inverter fed motor drive without any additional hardware. In order to confirm the presented algorithms, various experiments for bearing faults are tested and the line current spectrum of each faulty situation using park transformation is compared with a FFT results.

  • PDF

Dielectric Barrier Discharge for Ultraviolet Light Generation and Its Efficient Driving Inverter Circuit

  • Oleg, Kudryavtsev;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권3호
    • /
    • pp.101-105
    • /
    • 2004
  • The efficient power MOSFET inverter applied for a simple and low cost power supply is proposed for driving the dielectric barrier discharge (DBD) lamp load. For decades, the DBD phenomenon has been used for ozone gas production in industry. In this research, the ultraviolet and visible light sources utilizing the DBD lamp is considered as the load for solid-state high frequency power supply. It is found that the simple voltage-source single-ended quasi-resonant ZVS inverter with only one active power switch could effectively drive this load with the output power up to 700 W. The pulse density modulation based control scheme for the single-ended quasi-resonant ZVS inverter using a low voltage and high current power MOSFET switching device is proposed to provide a linear power regulation characteristic in the wide range 0-100% of the full power as compared with the conventional control based Royer type parallel resonant inverter type power supplies.